• Title/Summary/Keyword: 1-Axis and 3-Axis Accelerometer

Search Result 45, Processing Time 0.031 seconds

A 10-Lead Long Duration Ambulatory ECG Design -Minimizing power consumption-

  • Kim, Eung-Kyeu;Lee, Hoon-Kyeu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.1
    • /
    • pp.29-34
    • /
    • 2015
  • The ECG(Electrocardiograph) ambulatory test as called Holter is performed usually to diagnose several heart diseases causing different arrhythmias. This paper exposes the insights of the design of a 10-lead ambulatory ECG recorder. Reducing the size and minimizing the power consumption of the ECG recorder are crucial to allow long recording time without causing discomfort to the patient. This paper proposes lower hardware design and differential compression algorithm to extend the maximum 72 hours recording time in consideration of smaller and light-weighted recorder size. The performance results by newly introduced compression algorithm are shown and discussed.

Analysis of Measured Azimuth Error on Sensitivity Calibration Routine (Sensitivity Calibration 루틴 수행시 Tilt에 의한 방위각 측정 오차의 분석)

  • Woo, Kwang-Joon;Kang, Su-Min
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.1
    • /
    • pp.1-8
    • /
    • 2011
  • The accuracy of MR sensor-based electronic compass is influenced by the temperature drift and DC offset of the MR sensor and the OP-amp, the magnetic distortion of nearby magnetic materials, and the compass tilt We design the 3-axis MR sensor and accelerometers-based electronic compass which is compensated by the set/reset pulse switching method on the temperature drift and DC offset, by the execution of hard-iron calibration routine on the magnetic distortion, and by the execution of the Euler rotational equation on the compass tilt. We qualitatively analyze the measured azimuth error on the execution of sensitivity calibration routine which is the normalization process on the different sensitivity of each MR sensor and the different gain of each op-amps. This compensation and analytic result make us design the one degree accuracy electronic compass.

Time Domain of Algorithm for The Detection of Freezing of Gait(FOG) in Patients with Parkinson's Disease (파킨슨병 환자의 보행동결 검출을 위한 시간영역 알고리즘)

  • Park, S.H.;Kwon, Y.R.;Kim, J.W.;Eom, G.M.;Lee, J.H.;Lee, J.W.;Lee, S.M.;Koh, S.B.
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.4
    • /
    • pp.182-188
    • /
    • 2013
  • This study aims to develop a practical algorithm which can detect freezing of gait(FOG) in patients with Parkinson's disease(PD). Eighteen PD patients($68.8{\pm}11.1yrs.$) participated in this study, and three($68.7{\pm}4.0yrs.$) of them showed FOG. We suggested two time-domain algorithms(with 1-axis or 3-axes acceleration signals) and compared them with the frequency-domain algorithm in the literature. We measured the acceleration of left foot with a 3-axis accelerometer inserted at the insole of a shoe. In the time-domain method, the root-mean-square(RMS) acceleration was calculated in a moving window of 4s and FOG was defined as the periods during which RMS accelerations located within FOG range. The parameters in each algorithm were optimized for each subject using the simulated annealing method. The sensitivity and specificity were same, i.e., $89{\pm}8%$ for the time-domain method with 1-axis acceleration and were $91{\pm}7%$ and $90{\pm}8%$ for the time-domain method with 3-axes acceleration, respectively. Both performances were better in the time-domain methods than in the frequency-domain method although the results were statistically insignificant. The amount of calculation in the time-domain method was much smaller than in the frequency-domain method. Therefore it is expected that the suggested time domain algorithm would be advantageous in the systematic implementation of FOG detection.

Analysis of the characteristics of inertial sensors to detect position changes in a large space (넓은 공간에서 위치 변화를 감지하기위한 관성 센서의 특성 분석)

  • Hong, Jong-Kyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.770-776
    • /
    • 2021
  • Positioning systems have been actively researched and developed over the past few years and have been used in many applications. This paper presents a method to determine a location in a large space using a sensor system consisting of an accelerometer and a single-axis gyroscope. In particular, to consider usability, a sensor device was loosely worn on the waist so that the experimental data could be used in practical applications. Based on the experimental results of circular tracks with radiuses of 1m and 3m, in this paper, an algorithm using the threshold of rotation angle was proposed and applied to the experimental results. A tracking experiment was performed on the grid-pattern track model. For raw sensor data, the average deviation between the final tracking point and the target point was approximately 15.2 m, which could be reduced to approximately 4.0 m using an algorithm applying the rotation angle threshold.

Design of a Portable Activity Monitoring System (휴대용 활동 상태 모니터링 시스템의 설계)

  • Lee, Seung-Hyung;Park, Ho-Dong;Yoon, Hyung-Ro;Lee, Kyung-Joung
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.1
    • /
    • pp.32-38
    • /
    • 2002
  • This paper describes a development of a portable physical activity monitoring system using two accelerometers to quantify physical activity. The system hardware consists of two piezoresistive accelerometers, amplifiers with gain of 30, lowpass filters with cut-off frequency of 15Hz, offset control circuits, one-chip microcontroller and flash memory card. In order to evaluate the performance of the system we acquired 3 channel data at 32 sample/sec from body-fixed accelerometers in chest and right upper leg. And then the acquired data were processed by MatLab on personal computer. We tried to distinguish not only fundamental actions which are steady-state activities such as standing, sitting, and lying but also dynamic activities with walking, up a stairway, down a stairway, and running. Five subjects participated the evaluation process which compare the video data with the measured data. As a result, the activity classification rate of 90.6% on average was obtained. Overall results showed that the steady-state activities could be classified from the low component of 3-axis acceleration signal and dynamic activities could be distinguished from frequency analysis using wavelet transform and FFT. Finally, we could find that this system can be applied to acquire and analyze the static and dynamic physical activity data.

Effects of Angular Velocity Components on Head Vibration Measurements (각속도 성분들이 머리진동 측정치에 미치는 영향)

  • Park Yong Hwa;Cheung Wan Sup
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.1E
    • /
    • pp.7-15
    • /
    • 2005
  • This paper addresses issues encountered in measuring the general, 6-degree-of-freedom motion of a human head, A complete mathematical description for measuring the head motion using the six-accelerometer configured bite-bar is suggested, The description shows that the six-axis vibration cannot be completely obtained without the roll, pitch and yaw angular velocity components, A new method of estimating the three orthogonal (roll, pitch and yaw) angular velocities from the six acceleration measurements is introduced. The estimated angular velocities are shown to enable further quantitative error analysis in measuring the translational and angular accelerations at the head. To make this point clear, experimental results are also illustrated in this paper. They show that when the effects of angular velocities are neglected in the head vibration measurement the maximum percentage errors were observed to be more than $3 \%$ for the angular acceleration of the head and to be close to $5 \%$ for its translational acceleration, respectively. It means that the inclusion of all the angular velocity dependent acceleration components gives more accurate measurement of the head vibration.

Development of Attitude Heading Reference System based on MEMS for High Speed Autonomous Underwater Vehicle (고속 자율 무인잠수정 적용을 위한 MEMS 기술기반 자세 측정 장치 개발)

  • Hwang, A-Rom;Ahn, Nam-Hyun;Yoon, Seon-Il
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.6
    • /
    • pp.666-673
    • /
    • 2013
  • This paper proposes the performance evaluation test of attitude heading reference system (AHRS) suitable for small high speed autonomous underwater vehicle(AUV). Although IMU can provides the detail attitude information, it is sometime not suitable for small AUV with short operation time in view of price and the electrical power consumption. One of alternative for tactical grade IMU is the AHRS based micro-machined electro mechanical system(MEMS) which can overcome many problems that have inhibited the adoption of inertial system for small AUV such as cost and power consumption. A cost effective and small size AHRS which incorporates measurements from 3-axis MEMS gyroscopes, accelerometers, and 3-axis magnetometers has been developed to provide a complete attitude solution for AUV and the attitude calculation algorithm is derived based the coordinate transform equation and Kalman filter. The developed AHRS was validated through various performance tests as like the magnetometer calibration, operating experiments using land mobile vehicle and flight motion simulator (FMS). The test of magnetometer calibration shows the developed MEMS AHRS is robust to the external magent field change and the test with land vehicle proves the leveling error of developed MEMS AHRS is below $0.5^{\circ}/hr$. The results of FMS test shows the fact that AHRS provides the measurement with $0.5^{\circ}/hr$ error during 5 minutes operation time. These results of performance evaluation tests showed that the developed AHRS provides attitude information which error of roll and pitch are below $1^{\circ}$ and the error of yaw is below $5^{\circ}$ and satisfies the required specification. It is expected that developed AHRS can provide the precise attitude measurement under sea trial with real AUV.

The Effect of Resistance Exercise Using Elastic Band on Muscle Strength, Muscle Tone, Balance and Gait in Stroke Patients (탄성밴드를 이용한 저항운동이 뇌졸중 환자의 근력, 근긴장도, 균형 및 보행에 미치는 영향)

  • An, Soyeong;Kang, Soonhee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.1
    • /
    • pp.57-66
    • /
    • 2020
  • Purpose : This study aimed to identify whether resistance exercise using elastic bands for six weeks can improve muscle strength, muscle tone, balance, and gait in patients with stroke. Methods : In total, 35 patients with stroke were randomly divided into three groups: resistance exercise using elastic band training combined with less affected side training group, more affected side training group, and both sides training group. Muscle strength, muscle tone, balance, and gait were assessed using a hand-held dynamometer, the modified Ashworth scale, the Berg Balance scale (BBS), and wireless 3-axis accelerometer, before and after training. Results : All three groups showed a significant increase in muscle strength of the lower extremity after training, and there was a significant difference among the groups. There was no change in muscle tone in all three groups. BBS scores increased significantly in all three groups after training, but these scores were not significantly different. The gait speed increased significantly in all three groups after the training, but the difference was not significant. The cadence increased significantly in Group 2 after training; however, there was no significant difference between Groups 1 and 3. There were no significant differences between the groups before and after the training. Step length increased significantly in Groups 2 and 3 after the training, but it was not significantly different in Group 1. After training, Groups 2 and 3 were significantly greater than Group 1 in the change in step length. Conclusion : The results show that resistance exercise using elastic bands can improve strength, balance, and gait in patients with chronic stroke. Especially, more affected side training was more effective in improving muscle strength than less affected side training. More affected side and both sides training are thought to be more effective than less affected side training to improve step length.

Effect of Disturbance Modeling on IMMU-Based Orientation Estimation Accuracy (교란성분 모델링이 IMMU기반 자세추정 정확성에 미치는 영향)

  • Choi, Mi Jin;Lee, Jung Keun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.8
    • /
    • pp.783-789
    • /
    • 2017
  • In terms of 3D orientation estimation based on nine-axis IMMU(inertial and magnetic measurement unit), there are two disturbance components decreasing estimation accuracy: one is external acceleration disturbing accelerometer's signals and the other is magnetic disturbance related to magnetometer's signals. In order to minimize effects by these two disturbances, two approaches including switching approach and model-based approach have been suggested and further research comparing these two has also been conducted. Nevertheless, effect of disturbance modeling differences on orientation estimation accuracy in model-based approach has not been studied before. This paper compares the recently reported two orientation estimation algorithms that have difference in disturbance models, in order to investigate the effect of disturbance models on accuracy of IMMU-based orientation estimation under various operating conditions. This research shows that the difference in disturbance models leads to difference in process noise covariance matrix. Consequently, this affected the orientation estimation, i.e., the estimation differences between the algorithms were root mean square errors of $1.35^{\circ}$ in average and $3.63^{\circ}$ in yaw estimation.

The Wearable Sensor System to Monitor the Head & Neck Posture in Daily Life (웨어러블 센서를 이용한 일상생활중 머리-목 자세 측정 시스템)

  • Lee, Jaehyun;Chee, Youngjoon;Bae, Jieun;Kim, Haseon;Kim, Younghoon
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.112-118
    • /
    • 2016
  • The neck pain is fairly common occurance. Forward head posture and text neck are poor postures which may be related with neck pain but the evidence is not enough. We developed the wearable sensor which can assess the head & neck posture in daily life. Microprocessor, Bluetooth low energy, and 3-axis accelerometer, rechargeable battery and vibratior for reminding are used to implement the wearable sensor. Real-time algorithm to parameterize the posture for one epoch is implemented which classifies the posture in the epoch into three classed; dynamic, static_good posture, and static_poor posture. Also the algorithm makes reminding to its wearer to give them the prolonged poor posture is detected. The mean error of measurement was 1.2 degree. The correlation coefficient between neck angle and craniovertebral angle was 0.9 or higher in all cases. With the pilot study on text neck syndrome was also quatified. Average of neck angle were 74.3 degree during the listening in the classroom and 57.8 degree during the smartphoning. Using the wearable sensor suggested, the poor postures of forward head posture and neck neck can be detected in real-time which can remind the wearer according to his/her setting.