• 제목/요약/키워드: 1 g shaking table

검색결과 108건 처리시간 0.025초

포화된 모래지반의 액상화후 과잉간극수압 소산양상 (Dissipation Pattern of Excess Pore Pressure after Liquefaction in Saturated Sand Deposits)

  • 하익수;박영호;김명모
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.90-97
    • /
    • 2003
  • The purpose of this study is to understand the dissipation pattern of excess pore pressure after liquefaction which governs the post-liquefaction behavior of liquefied sand deposits. 1-g shaking table tests were carried out on 5 different kinds of sands, all of which had high liquefaction potentials. During the tests excess pore pressure at various depths, and surface settlements were measured. The measured curve of the excess pore pressure dissipation was simulated using the solidification theory, and from the analysis of the velocity of dissipation, the dissipation pattern of excess pore pressure after liquefaction was examined. The dissipation velocity of excess pore pressure after liquefaction had a linear correlation with the effective grain size ( $D_{10}$) divided by the coefficient of uniformity ( $C_{u}$), and the increase in the initial relative density of the ground played a role in shifting this correlation curve toward an increased dissipation velocity. From the correlation, an approximate method was recommended for prediction of the dissipation curve of excess pore pressure after liquefaction in saturated sand deposits.s.s.

  • PDF

사질토 지반 위에 축조된 제방의 액상화 및 최적 대책 공법 (Liquefaction of Embankments on Sandy Soils and the Optimum Countermeasure against the Liquefaction)

  • Park, Young-Ho;Kim, Sung-Ryul;Kim, Sung-Hwan;Kim, Myoung-Mo
    • 한국지반공학회논문집
    • /
    • 제16권3호
    • /
    • pp.15-21
    • /
    • 2000
  • 액상화되기 쉬운 모래지반 위에 축조된 제방의 지진시 거동을 조사하고 액상화 경감을 위한 대책공법의 효과를 비교하기 위하여 12가지 경우에 대해 진돈대 시험을 수행하였다. 본 시험에는 널말뚝, 자갈배수재, 모래다짐 말뚝과 강관말뚝 등의 대책공법이 적용되었다. 진동대 시험에 사용된 투명토조의 길이는 194cm이고 폭은 44cm 그리고 높이는 60cm이다. 기초지반은 포화된 모래이며 수중침강법을 적용하여 상대밀도 약 30%로 조성되었다. 이 포화된 느슨한 모래지만 위에 15cm 높이의 제방이 경사 1:1.5로 축조되었다. 진동대 시험시 제방과 기초지반의 거동을 측정하기 위해서 간극수압계 12개, 가속도계 4개 및 LVDT 2개가 시험모델에 설치되었다. 진동대의 크기는 2m$\times$2m이며, 진동시의 입력가속도는 0.1g에서 시작하여 최고 0.4g까지 증가시켰다. 본 모델에 적용된 공법 모두가 일반적인 진동법위에서 액상화 발생을 억제시키는데 유용한 것으로 증명이 되었으며, 그 중에서 모래다짐말뚝이 액상화로 인한 피해를 감소시키는데 가장 효과적인 것으로 나타났다. 또한 각각의 대책공법에 대한 최적 배치안의 본 연구에서 제시되었다.

  • PDF

Investigating the dynamic response of deep soil mixing and gravel drain columns in the liquefiable layer with different thickness

  • Gholi Asadzadeh Khoshemehr;Hadi Bahadori
    • Geomechanics and Engineering
    • /
    • 제34권6호
    • /
    • pp.665-681
    • /
    • 2023
  • Liquefaction is one of the most devastating geotechnical phenomena that severely damage vital structures and lifelines. Before constructing structures on problematic ground, it is necessary to improve the site and solve the geotechnical problem. Among ground improvement methods dealing with liquefaction, gravel drain (GD) columns and deep soil mixing (DSM) columns are popular. In this study, the results of a series of seismic experiments in a 1g environment on a structure located over liquefiable ground with different thicknesses reinforced with GD and DSM techniques were presented. The dynamic response of the reinforced ground system was investigated based on the parameters of subsidence rate, excess pore water pressure ratio, and maximum acceleration. The time history of the input acceleration was applied harmonically with an acceleration range of 0.2g and at frequencies of 1, 2, and 3 Hz. The results show that the thickness of the liquefiable layer and the frequency of the input motion have a significant impact on the effectiveness of the improvement method and all responses. Among the two techniques used, DSM in thick liquefied layers was much more efficient than GD in controlling the subsidence and rupture of the soil under the foundation. Maximum settlement values, settlement rate, and foundation rotation in the thicker liquefied layer at the 1-Hz input frequency were higher than at other frequencies. At low thicknesses, the dynamic behavior of the GD was closer to that of the DSM.

지진하중을 받는 대형 콘크리트 판구조의 동적거동-3층 입체구조의 진동실험결과를 중심으로 (Dymamic Behavior of Large Concrete Panel Structures Subjected Seismic Loads)

  • 서수연;박병순;백용준;이원호;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1993년도 봄 학술발표회 논문집
    • /
    • pp.148-153
    • /
    • 1993
  • The paper presents the results of shaking table test conducted on the 1/3.3 scaled large concrete panel model. The behaviors of large concrete panel structures subjected to seismic excitations are controlled by capacity of horizontal and vertical joints. To Study the seismic capacity of the large concrete panel structures, experimental researches for joints and structural assemblage are needed. Especially, since the magnitude of seismic loads are depended on the variation of time, period and accelerations, dynamic test is needed for estimating the seismic resistance of large concrete panel structures. The objective of this paper is to study the behaviors of large concrete panel structures on seismic excitations and to estimate the safety. Test results are as follows : 1) Test model was critically damaged in the first floor horizontal joint by rocking. 2) Elastic limit(0.12kg) of test model was 5times higher than that of korean seismic design code. 3) Maxium base shear of test model at the ground acceleration of 0.12g was 3.5 times higher than the result of equivalent static analysis. 4) Damping ratio of test model turned out 3.9~5.3% and the period at 0.12g was 0.065sec.

  • PDF

154 kV 및 345 kV 주변압기 부싱의 내진성능 시험 연구 (The Experimental Study on Seismic Capacity of 154 kV & 345 kV Main Transformer Bushings)

  • 황경민;함경원;김경환
    • 한국지진공학회논문집
    • /
    • 제22권2호
    • /
    • pp.87-94
    • /
    • 2018
  • In this study, seismic performance of bushings and their connection parts was analyzed by performing shaking table tests for various types of bushings widely used as auxiliary equipment of main transformers in domestic substations. As a result of the seismic tests of five types of 154 kV bushings according to the manufacturers, all the bushings secured the structural integrity even at the acceleration of 1.4 g and it was found that leakage of insulating oil didn't occur. Also, the average acceleration amplification rate at the upper part of the bushings was about 2.5 to 3.0 times higher than the lower one. On the other hand, when a representative 345 kV bushing was subjected to the seismic test, the structural integrity was secured even at 1.0 g acceleration similar to the design earthquake load level, but in this test, leakage of insulating oil occurred. However, when a stiffener restricting the connection of the bushing is installed in the same 345 kV bushing, the displacement of the bushing connection is controlled and the stiffener prevent the oil from leaking even at the acceleration of the designed seismic level.

모래 지반의 입자크기가 지반-말뚝 시스템의 동적 거동에 미치는 영향 평가 (Evaluation of Particle Size Effect on Dynamic Behavior of Soil-pile System)

  • 유민택;양의규;한진태;김명모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.188-197
    • /
    • 2010
  • This paper presents experimental results of a series of 1-g shaking table model tests performed on end-bearing single piles and pile groups to investigate the effect of particle size on the dynamic behavior of soil-pile systems. Two soil-pile models consisting of a single-pile and a $4{\times}2$-pile group were tested twice; first using Jumoonjin sand, and second using Australian Fine sand, which has a smaller particle size. In the case of single-pile models, the lateral displacement was almost within 1% of pile diameter which corresponds to the elastic range of the pile. The back-calculated p-y curves show that the subgrade reaction of the Jumoonjin-sand-model ground was larger than that of the Australian Fine-sand-model ground at the same displacement. This phenomenon means that the stress-strain behavior of Jumoonjin sand was initially stiffer than that of Australian Fine sand. This difference was also confirmed by resonant column tests and compression triaxial tests. And the single pile p-y backbone curves of the Australian fine sand were constructed and compared with those of the Jumoonjin sand. As a result, the stiffness of the p-y backbone curves of Jumunjin sand was larger than those of Australian fine sand. Therefore, using the same p-y curves regardless of particle size can lead to inaccurate results when evaluating dynamic behavior of soil-pile system. In the case of the group-pile models, the lateral displacement was much larger than the elastic range of pile movement at the same test conditions in the single-pile models. The back-calculated p-y curves in the case of group pile models were very similar in both sands because the stiffness difference between the Jumoonjin-sand-model ground and the Australian Fine-sand-model ground was not significantly large at a large strain level, where both sands showed non-linear behavior. According to a series of single pile and group pile test results, the evaluation group pile effect using the p-multiplier can lead to inaccurate results on dynamic behavior of soil-pile system.

  • PDF

액상화 지반에 근입된 말뚝의 파괴거동 분석 (Analysis of Failure Behavior of Piles Embedded in Liquefied Soil Deposits)

  • 조종석;한진태;황재익;박영호;김명모
    • 한국지반공학회논문집
    • /
    • 제22권11호
    • /
    • pp.123-131
    • /
    • 2006
  • 지진 시 액상화에 의한 지반흐름은 말뚝파괴에 가장 큰 영향을 미치는 것으로 알려져 있다. 실제로 충분히 큰 정적 안전율을 갖도록 설계된 말뚝이 지진 시 좌굴에 의해 파괴되는 사례가 빈번히 발생하였다. 본 연구에서는 1-g 진동대 실험을 통해 액상화 지반에 근입된 말뚝의 좌굴에 의한 파괴거동을 분석하였다. 실험 결과, 좌굴하중에 근접한 연직하중을 받고 있는 말뚝은 지반의 액상화 발생 시 좌굴에 의해 쉽게 파괴될 수 있으며 액상화에 의한 지반흐름이 발생할 경우, 말뚝의 횡방향 변형이 증가하면서 좌굴파괴하중이 감소함을 알 수 있었다. 또한 파괴된 말뚝을 꺼내어 관찰한 결과, 액상화가 발생한 후라도 지반에 구속압이 존재하여 Euler 좌굴현상과 다르게 말뚝 하부가 아닌 중간위치에서 말뚝파괴가 발생하였으며 지반경사가 급해질수록 지반흐름에 의한 파괴 위치가 점점 말뚝하부로 낮아짐을 볼 수 있었다.

실대형 진동대 시험을 통한 복층터널 중간 슬래브 진동 감쇠 고무받침 내진성능 평가 (Seismic performance evaluation of middle-slab vibration damping rubber bearings in multi-layer tunnel through full-scale shaking table)

  • 장동인;박인준
    • 한국터널지하공간학회 논문집
    • /
    • 제22권4호
    • /
    • pp.337-346
    • /
    • 2020
  • 도심권의 교통 집중과 정체로 인하여 지하 공간 활용성이 필요함에 따라 지하구조물에 대한 연구가 늘어나고 있다. 그 중 복층터널은 지하구조물을 대표 할 수 있다. 복층터널은 중간슬래브를 기준으로 상, 하부 차도를 구분하여 운영하고 있다. 중간슬래브는 차량의 하중 및 지진하중에 의하여 동적거동을 한다. 특히 지진의 의한 응답특성은 하중의 크기 및 작용 메커니즘이 매우 복잡하고 이론적 접근이 어려워 실험적 연구가 필요하다. 본 연구에서는 붕괴방지 내진 1등급의 복층터널 중간슬래브에 진동 감쇠 고무받침 유무에 따른 안정성 평가를 실시하는데 목적을 두고 있다. 본 진동대 실험에서는 상사율 1/4을 적용하였으며, 모형실험에서 지반과 모형의 일체거동을 묘사하기 위하여 라이닝과 진동대판을 고정시켰으며 이를 통해서 상대거동을 최소화 하였다. 실험대상은 가상복층터널 TBM 표준단면으로 정했다. 기반암에 가해지는 지반운동 수준을 0.154 g (붕괴방지 수준 내진 1등급 인공지진파)이며 이 가속도를 최대로 하는 지진파를 진동대 입력(기반암)에 작용시켜 모형에 증폭현상을 분석하고 진동 감쇠 고무받침 유무에 따른 중간슬래브의 내진 안정성에 대해 평가 분석 하였다. 그 결과, 지진 감쇠 고무받침 유무에 따라서 지진 가속도 감쇠 효과가 최대 40% 이상 있음을 알 수 있었다.

원심모형 실험을 이용한 지반-말뚝 상호작용의 정적 및 동적 거동 평가 (Comparison of Lateral Pile Behavior under Static and Dynamic Loading by Centrifuge Tests)

  • 유민택;권선용
    • 한국지반공학회논문집
    • /
    • 제34권7호
    • /
    • pp.51-58
    • /
    • 2018
  • 본 연구에서는 하중 조건에 따른 지반-말뚝 상호작용 시스템의 거동 차이를 분석하기 위해 일련의 원심모형 실험을 수행하였다. 정적 하중 조건의 경우, 말뚝 직경의 50% 수준까지 변위제어를 통해 하중을 재하하였으며, 지진 하중 조건의 경우 0.1g~0.4g 수준으로 1Hz 정현파를 가진하였다. 실험 결과로부터 얻은 정적 및 동적 p-y 곡선을 API p-y 곡선과 비교한 결과, API p-y 곡선과 정적 하중조건에서의 실험 p-y 곡선은 최대 지반반력 값이 20% 이내의 오차를 보인 반면, 동적 하중 조건에서의 실험 p-y 곡선과는 최대 지반반력 값이 5배 이상 차이가 발생하였다. 이는 등가정적 해석에서 기존 API p-y 곡선을 적용할 경우 비선형 영역에서 지반 반력을 크게 과소평가하며 보수적 설계를 야기할 수 있음을 의미한다.

유리섬유로 보강한 조적벽체의 전단내력식 설정에 관한 연구 (Proposing the Shear Force Equation of GFRP Strengthened Masonry Wall)

  • 권기혁;이수철;정원철
    • 한국방재학회 논문집
    • /
    • 제7권1호통권24호
    • /
    • pp.1-9
    • /
    • 2007
  • 본 연구는 국내에 시공된 조적조 건축물의 특징을 반영한 조적벽체의 반복가력과 모의진동대 실험을 통해 얻어진 결과를 근거로 하여 유리섬유로 보강된 보강조적벽체의 전단내력식을 제안하는 것을 목적으로 한다. 실험결과, 개구부가 없는 조적벽체의 파괴를 지배하는 모드는 Rocking이였고, 개구부가 있는 경우는 개구부 주변에 균열이 집중되었다. 비보강 조적벽체의 전단내력식은 UBC에서 제시한 식이 실험과 가장 유사한 값을 보였다. 본 연구를 통해 제안되어지는 유리섬유 보강조적벽체의 전단내력식은 다음과 같다. $$V_n=0.02A_n{\sqrt{f'_m}}+0.022b_gh_g(1+2{\alpha})^3{\sqrt{f_g}}(N/mm^2)$$.