• 제목/요약/키워드: 1 MVA

검색결과 132건 처리시간 0.024초

전압조정과 고조파 저감을 위한 배전용 STATCOM 개발 (A Development of a Distribution STATCOM for Voltage Regulation and Harminic Mitigation)

  • 추진부;전영수;윤종수;한영성;홍순욱;이학성;신희승
    • 전력전자학회논문지
    • /
    • 제4권6호
    • /
    • pp.601-607
    • /
    • 1999
  • 본 논문에서는 순간전압조정, 역률 보상, 고조파 저감에 대한 배전용 정지형 동기조상기(STATCOM : STATic COMpensator)에 대한 다양한 제어 모드를 제안하고 있다. 이러한 제어 알고리즘의 성능을 검증하기 위해 각 제어 알고리즘을 20kVA의 축소형 STATCOM에 적용하고 간단한 배전계통을 꾸며 시험하였다. 실험결과로부터 제안한 제어알고리즘이 Custom Power 시스템으로 훌륭한 성능을 보임을 확인할 수 있었다. 실재 배전계통에 적용하여 현재 1MVA STATCOM이 성공적으로 운전되고 있다.

  • PDF

새로운 ZVS 3-레벨 공진폴 인버터 (A Novel ZVS 3-Level Resonant Pole Inverter)

  • 백주원;조정구;유동욱;송두익;원충언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.360-364
    • /
    • 1995
  • A zero voltage switching (ZVS) three level resonant pole inverter is presented for high power GTO inverters. The concept of auxiliary resonant commutated pole(ARCP) for two level inverter is extended to the three level inverter. The proposed auxiliary commutation circuit consists of one resonant inductor and two bi-directional switches, which provides ZVS condition to the main devices without increasing device voltage or current stresses. The auxiliary device operates with zero current switching(ZCS) which enables use of the low cost thyristors. The proposed circuit can handle higher voltage and higher power(1-10MVA) comparing to the two level one. Operation and analysis of the proposed circuit are illustrated. Experimental results with 10 KW, 4 kHz prototype are presented to verify the principle of operation.

  • PDF

직류변환 송전방식 국내도입 타당성 검토 : 신옥천-서대구 345kV송전선로 1회선 직류변환 설계 (Feasibility Study of the application of HVDC System to Domestic Power System ' Design of the HVDC system for Sinokchun-Sedaegu 345kV Transmission line)

  • 김동준;윤재영;양광호;문영환;이동일;신구용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.186-188
    • /
    • 2004
  • This paper describes the feasibility study of HVDC system application to KEPCO power system for increasing power transfer capability or the flexibility of power delivery from one area to the other using the existing transmission line. This paper assumes the 345kV transmission line connecting between Shinokchun and Sedaegu to be converted to the DC line by replacing the AC insulator with that of DC. Then, the HVDC bipole system of 1000MVA with $\pm300kV$ is designed and the contingency studies are carried out.

  • PDF

대륙붕 2광구 서해분지 북부지역의 3D전산처리 최적화 방안시 고려점 (The Consideration for Optimum 3D Seismic Processing Procedures in Block II, Northern Part of South Yellow Sea Basin)

  • 고승원;신국선;정현영
    • 한국석유지질학회지
    • /
    • 제11권1호
    • /
    • pp.9-17
    • /
    • 2005
  • 2광구의 주요 탐사지역에는 심도 1 km 내외의 부정합면 하부에 대규모 단층이 발달되어 있다. 통상 이 부정합 인근의 탄성파 속도차는 매우 큰 편으로서 강한 다중반사파가 흔하게 발달되었고 탄성파 단면도는 왜곡되어 중합단면의 질적 저하가 예상되었다. 구조 인근의 다중반사파를 제거하고 해상력을 제고하기 위해 15가지 이상의 다양한 전산처리 기법이 적용되었다. 진폭 감소보정, 미약한 F/K 적용으로 일관성 잡음을 감쇠시켰다. 중합전 예측디콘볼루션으로 페그레그 다중반사파를 제거하였고 중합속도를 구하기 위해 매 2 km 간격으로 분석되었다. 잔여 다중반사파도 parabolic 라돈 변형절차를 거쳐 제거되었다. 중합자료를 얻기 위해 곡선파 curved ray Kirchhoff형 알고리즘이 적용되었으며, MVA (migration velocity analysis)가 이용되었다. 결과적으로 자료 취득기간의 기상변화 등 취득시의 문제점으로 지적된 불량한 잡음이 섞인 트레이스는 최초로 CDP gathers에서 제거되었다. 이후 다수의 전산처리 기법을 써서 최적의 전산처리 변수가 구해졌으며 그 결과 서해대륙붕 2광구의 구조 및 층서 해석에 적합한 탄성파 단면도 획득을 위한 인자들을 얻을 수 있었다.

  • PDF

전력선 용량증대를 위한 해저케이블 설계 (Design of Submarine Cable for Capacity Extension of Power Line)

  • 손홍철;문채주;김동섭
    • 한국전자통신학회논문지
    • /
    • 제17권1호
    • /
    • pp.77-84
    • /
    • 2022
  • 해저 전력케이블은 수면 아래로 전력을 운송하는 송전케이블이다. 최근 해저케이블은 해상의 재생에너지인 풍력, 파력 및 조류시스템 등의 전력을 육지로 전송하며, 이 케이블이 위치하는 장소에 따라 해저에 매설하거나 해저면에 놓여진다. 전력케이블은 극한 환경에서 이용되어 왔기 때문에 가혹한 조건들과 온도 및 강한 조류를 견디도록 제작되나, 해저조건은 해상케이블에 대해 수 많은 종류의 심각한 손상을 만들기에 충분한 조건을 갖는다. 이러한 원인은 전력전송을 중단시키는 케이블 손상을 가져온다. 본 논문에서는 케이블에 대한 설계기준과 시공절차와 난제 그리고 케이블 전환 접속시스템에 대하여 연구한다. 설계된 해저케이블의 규격은 154kV 기존 케이블 1회선과 신규 케이블 2회선 등 3회선으로 구성되고, 선로당 100MVA 전력용량을 갖는다. 해저케이블 매설깊이를 결정하고 기존 및 신규 케이블을 함께 배치하는 방법을 연구하였다. 지중선로에 대한 해저케이블의 전력용량 허용값을 계산하였고 그 결과 케이블 선로당 100MW 이상의 전력용량을 갖는다는 것을 확인하였다.

Fabrication and Characteristic Tests of a 1 MVA Single Phase HTS Transformer with Concentrically Arranged Windings

  • Kim, S.H.;Kim, W.S.;Choi, K.D.;Joo, H.G.;Hong, G.W.;Han, J.H.;Lee, H.G.;Park, J.H.;Song, H.S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권4호
    • /
    • pp.37-40
    • /
    • 2004
  • A 1 MV A single phase high temperature superconducting (HTS) transformer was manufactured and tested. The rated voltages of primary and secondary of the HTS transformer are 22.9 kV and 6.6 kV respectively. BSCCO-2223 HTS tape was used for HTS windings of 1 MV A HTS transformer. In order to reduce AC loss generated in the HTS winding, the type of concentric arrangement winding was adopted to a 1 MV A HTS transformer. Single HTS tape for primary windings and 4 parallel HTS tapes for secondary windings were used considering the each rated current of the HTS transformer. A core of HTS transformer was fabricated as a shell type core made of laminated silicon steel plate. And a GFRP cryostat with a room temperature bore was also manufactured. The characteristic tests of 1 MV A HTS transformer were performed such as no load test, short circuit test and several insulation tests at 65 K using sub-cooled liquid nitrogen. From the results of tests, the validity of design of HTS transformer was ascertained.

Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

  • Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.280-285
    • /
    • 2014
  • In order to evaluate the insulation deterioration in the stator windings of five gas turbine generators(137 MVA, 13.8 kV) which has been operated for more than 13 years, diagnostic test and AC dielectric breakdown test were performed at phases A, B and C. These tests included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B and C) of No. 1 generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable and bad level to the insulation condition. Overall analysis of the results suggested that the generator stator windings were indicated serious insulation deterioration and patterns of the PD in all three phases were analyzed to be internal, slot and spark discharges. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. The breakdown voltage at phases A, B and C of No. 1 generator stator windings failed at 28.0 kV, 17.9 kV, and 21.3 kV, respectively. The breakdown voltage was lower than that expected for good-quality windings (28.6 kV) in a 13.8kV class generator. In the AC dielectric breakdown and diagnostic tests, there was a strong correlation between the breakdown voltage and the voltage at which charging current increases abruptly ($P_{i1}$, $P_{i2}$).

Assessment of an Apo-1/Fas Promoter Polymorphism in Korean Schizophrenia Patients

  • Kim, Soon-Ae;Kim, Youn-Jung;Choe, Bong-Keun;Lee, Hee-Jae;Kim, Jong-Woo;Park, Jong-Deuk;Kim, Chang-Ju;Park, Seung-Joon;Jung, Jee-Chang;Chung, Joo-Ho
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제6권3호
    • /
    • pp.161-163
    • /
    • 2002
  • Apoptosis has been hypothesized to be involved in the pathogenesis in schizophrenia. A large number of genes are known to mediate the apoptotic process; Apo-1/Fas (CD95) is a well-known example of such genes. In the present study, MvaI restriction fragment length polymorphism, a polymorphic marker present within the Apo-1/Fas gene, was examined in a population consisting of 226 control subjects and 110 schizophrenia patients, all of them Korean in ethnicity. No statistically significant difference in the genotypic distribution and allelic frequencies was observed between the control and the schizophrenia patient group. To find out the precise effect of Apo-1/Fas gene polymorphisms on the susceptibility to schizophrenia, further studies are warranted to investigate possible involvement of other polymorphisms with a larger sample population.

Performance of Homologous and Heterologous Prime-Boost Immunization Regimens of Recombinant Adenovirus and Modified Vaccinia Virus Ankara Expressing an Ag85B-TB10.4 Fusion Protein against Mycobacterium tuberculosis

  • Kou, Yiming;Wan, Mingming;Shi, Wei;Liu, Jie;Zhao, Zhilei;Xu, Yongqing;Wei, Wei;Sun, Bo;Gao, Feng;Cai, Linjun;Jiang, Chunlai
    • Journal of Microbiology and Biotechnology
    • /
    • 제28권6호
    • /
    • pp.1022-1029
    • /
    • 2018
  • Tuberculosis (TB) remains a serious health issue around the word. Adenovirus (Ad)-based vaccine and modified vaccinia virus Ankara (MVA)-based vaccine have emerged as two of the most promising immunization candidates over the past few years. However, the performance of the homologous and heterologous prime-boost immunization regimens of these two viral vector-based vaccines remains unclear. In the present study, we constructed recombinant Ad and MVA expressing an Ag85B-TB10.4 fusion protein (AdH4 and MVAH4) and evaluated the impact of their different immunization regimens on the humoral and cellular immune responses. We found that the viral vector-based vaccines could generate significantly higher levels of antigen-specific antibodies, $IFN-{\gamma}$-producing splenocytes, $CD69^+CD8^+$ T cells, and $IFN-{\gamma}$ secretion when compared with bacillus Calmette-$Gu{\acute{e}}rin$ (BCG) in a mouse model. AdH4-containing immunization regimens (AdH4-AdH4, AdH4-MVAH4, and MVAH4-AdH4) induced significantly stronger antibody responses, much more $IFN-{\gamma}$-producing splenocytes and $CD69^+CD8^+$ T cells, and higher levels of $IFN-{\gamma}$ secretion when compared with the MVAH4-MVAH4 immunization regimen. The number of $IFN-{\gamma}$-producing splenocytes sensitive to $CD8^+$ T-cell restricted peptides of Ag85B (9-1p and 9-2p) and Th1-related cytokines ($IFN-{\gamma}$ and $TNF-{\alpha}$) in the AdH4-MVAH4 heterologous prime-boost regimen immunization group was significantly higher than that in the other viral vector-based vaccine- and BCG-immunized groups, respectively. These results indicate that an immunization regimen involving AdH4 may have a higher capacity to induce humoral and cellular immune responses against TB in mice than that by regimens containing BCG or MVAH4 alone, and the AdH4-MVAH4 prime-boost regimen may generate an ideal protective effect.

Design of HTS power cable with fault current limiting function

  • Kim, Dongmin;Kim, Sungkyu;Cho, Jeonwook;Kim, Seokho
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권1호
    • /
    • pp.7-11
    • /
    • 2020
  • As demand for electricity in urban areas increases, it is necessary to improve electric power stability by interconnecting neighboring substations and high temperature superconductor (HTS) power cables are considered as a promising option due to its large power capacity. However, the interconnection of substations reduces grid impedance and expected fault current is over 45 kA, which exceeds the capacity of a circuit breaker in Korean grid. To reduce the fault current below 45 kA, a HTS power cable having a fault current limiting (FCL) function is considered by as a feasible solution for the interconnection of substations. In this study, a FCL HTS power cable of 600 MVA/154 kV, transmission level class, is considered to reduce the fault current from 63 kA to less than 45 kA by generating an impedance over 1 Ωwhen the fault current is induced. For the thermal design of FCL HTS power cable, a parametric study is conducted to meet a required temperature limit and impedance by modifying the cable core from usual HTS power cables which are designed to bypass the fault current through cable former. The analysis results give a minimum cable length and an area of stainless steel former to suppress the temperature of cable below a design limit.