• Title/Summary/Keyword: 1 Life Time Test

Search Result 959, Processing Time 0.041 seconds

Accelerated Life Test Plans Based on Small Sample Property

  • Yun, Won Young
    • Journal of Korean Society for Quality Management
    • /
    • v.23 no.1
    • /
    • pp.41-49
    • /
    • 1995
  • This paper suggests optimal accelerated constant stress life tests in Exponential distribution. The relationship between the log-mean life and the loaded stress is assumed to be linear. Optimal plans considering mean square errors of maximum likelihood estimators of the log mean life and test costs are obtained. We consider accelerated life tests with two stress levels, and as data types, failure censoring( type II) and time censoring(type I) data are used. We propose the procedure to obtain the optimal plans for each case. Some examples are also included.

  • PDF

Evaluation of Characteristics and Useful Life of Rubber Spring for Railway Vehicle

  • Woo, Chang-Su;Park, Hyun-Sung;Park, Dong-Chul
    • International Journal of Railway
    • /
    • v.1 no.3
    • /
    • pp.122-127
    • /
    • 2008
  • Rubber components are widely used in many application such as vibration isolators, damping, ride quality. Rubber spring is used in primary suspension system for railway vehicle. Characteristics and useful life prediction of rubber spring was very important in design procedure to assure the safety and reliability. Non-linear properties of rubber material which are described as strain energy function are important parameter to design and evaluate of rubber spring. These are determined by physical tests which are uniaxial tension, equi-biaxial tension and pure shear test. The computer simulation was executed to predict and evaluate the load capacity and stiffness for rubber spring. In order to investigate the useful life, the acceleration test were carried out. Acceleration test results changes as the threshold are used for assessment of the useful life and time to threshold value were plotted against reciprocal of absolute temperature to give the Arrhenius plot. By using the acceleration test, several useful life prediction for rubber spring were proposed.

  • PDF

A Study on the Estimation of Shelf Life for Fuze MTSQ KM577A1 from ASRP Data (저장탄약신뢰성평가 데이터를 이용한 기계식시한신관 KM577A1 저장수명 추정 연구)

  • Lee, Dongnyok;Yoon, Keunsig
    • Journal of Applied Reliability
    • /
    • v.18 no.1
    • /
    • pp.56-65
    • /
    • 2018
  • Purpose: The purpose of this study is to estimate shelf life of fuze MTSQ (Mechanical Time & Super Quick) KM577A1 from Ammunition Stockpile Reliability Program (ASRP) data. Methods: For many years, ammunition test data had been gathered from ASRP. In this study, lot selection criteria and reliability score of functioning time for fuze are proposed. Reliability score of functioning time and failure data are used to estimate shelf life. Results: The results of this study are as follows; The failure modes of fuze MTSQ KM577A1 are dud, inverse function and mechanical time functioning failure (not operating in intended time). Dud and inverse function are major failure modes. Fuze MTSQ KM577A1's shelf life ($B_5$) is estimated 18.2 years conservatively. Conclusion: Degradation of chemical components in fuze MTSQ KM577A1 is major factor for its reliability. And shelf life ($B_5$) of fuze MTSQ KM577A1 is estimated 18.2 years conservatively.

Expansions and Applications of Item Life-time Testing (제품(製品) 수명(壽命) 시험(試驗)의 응용(應用)과 확장(擴張))

  • Lee, Chang-Ho
    • Journal of Korean Society for Quality Management
    • /
    • v.11 no.1
    • /
    • pp.10-17
    • /
    • 1983
  • This paper studies item-life test plans with the specified item mean life $T_1$ (MTBF) - Producer's risk ${\alpha}$ and item mean life $T_2$ (MTBF, $T_2$ < $T_1$) - Consumer's risk ${\beta}$ when the probability of item survival follows the Weibull distribution (known shape parameter) as a expansion of [1]. And Operating Characteristic Curves and Average Life-testing Times of item-life test plans are computed for this paper and [1]. Cost analysis procedures are same as [1]. These results are computed by using computer program written in Level II Basic for Apple II Plus Micro-computer. Both this paper and [6] reduce the life-testing time for Weibull distribution in comparision with Exponential distribution, but results of [6] were computed for different criterions from this paper.

  • PDF

The Predicton of the Shelf-life of Packaged Meals (Kim Pab) Marketed in Covenience Stores Using Simulation Study (모의실험을 통한 편의점 판매용 김밥 도시락의 유통기한 예측)

  • 곽동경;김성희
    • Journal of Food Hygiene and Safety
    • /
    • v.11 no.3
    • /
    • pp.189-196
    • /
    • 1996
  • Based on microbiological-chemical test results under simulated time-temperature conditions, total plate count, coliform, and volatile basic nitrogen were selected as effective quality indicators for estimating probable shelf-life on Kim Pab dosirak marketed in convenience stores, and shelf-life at each storage temperature was calculated from regression equation between effective quality indicator standard limit and storage time. Estimated shelf lives of Kim Pab Dosirak were 17, 3 and 2 hours respectively under 1$0^{\circ}C$, 2$0^{\circ}C$ and 3$0^{\circ}C$. Because shelf-life was especially affected by intial values, regression analysis between initial effective quality indicator values and storage hours was performed for the estimation of probable shelf-life on Kim Pab during storage at 10, 20, or 3$0^{\circ}C$.

  • PDF

Comparison of Trajectory of Quality of Life in Patients with High Risk Breast Cancer Undergoing Adjuvant Chemotherapy and Autogenous Bone Marrow Transplantation (보조적 표준 항암 화학요법에 비한 자가조혈모세포 이식 유방암 환자 삶의 질 내용 비교)

  • Lee, Eun-Ok
    • Asian Oncology Nursing
    • /
    • v.1 no.1
    • /
    • pp.5-17
    • /
    • 2001
  • It is known that aggressive treatment of chemotherapy, radiation and autogenous stem cell transplantation is effective for prevention of recurrence in the high-risk breast cancer patients. It was assumed that this procedure takes a longer time and decreases the quality of life more than the standard adjuvant chemotherapy. However, there are few studies comparing the quality of life of patients having bone marrow transplantation and adjuvant chemotherapy. Most of the studies were focused on the quality of life in one point of time, such as only during the early treatment stage, only overall quality of life rather than specific dimensions of the quality of life. The purposes of this study are 1) to identify the difference of the quality of life between two different treatment patterns, adjuvant chemotherapy and autogenous stem cell transplantation: 2) to identify the mostly affected dimension and the periods of time affected by the treatment patterns; and 3) to identify the trajectories of quality of life in each treatment pattern. This is a time series design that measures 4 different points of times. At the beginning of the study, 19 patients were placed in the chemotherapy group and 12 in the group of auto-peripheral blood stem cell transplantation. The inclusion criterion was the advanced disease stage of 3 or over with metastasis of more than 5 lymph nodes. The exclusion criteria were 1) anyone who has metastasis to other organ; 2) anyone who had psychological problems. Ferrell's Quality of Life Scale for Cancer Survivors 41 items on a 10 point scale was used. The QOL-CS includes 4 dimensions, which were labeled physical, psychological, social, and spiritual. The Cronbach‘s alpha of this scale was 0.89. Mann-Whitney U test and Friedman test were used to test each hypothesis. In comparison of the two groups, the quality of life of the bone marrow transplantation group dramatically increased at the 3rd and 6th month after transplantation, while the chemotherapy groups results stayed lower. The most affected dimension of the quality of life at the end of the treatment was the physical dimension. However, it and increased along with time, while the psychological dimension values remained low over the long-term period. Intensive nursing care is needed during the entire period of chemotherapy in all patients having chemotherapy, and is also required for right after cases of bone marrow transplantation.

  • PDF

Development of Life Test Specification for Catalytic Gas Sensor (접촉연소식 가스센서의 수명시험기준 개발)

  • Kang Jun-Ku;Park Jung-Won;Hwang Dong-Hoon;Ham Jung-Keol
    • Journal of Applied Reliability
    • /
    • v.6 no.1
    • /
    • pp.37-50
    • /
    • 2006
  • The accelerated life tests of the catalytic gas sensor were performed at three different gas concentration conditions. From the test data, the power-Weibull model was estimated and the acceleration factor between test condition 25%LEL(Lowe Explosive Limit) and use condition 5%LEL was about 3 according to this acceleration model. Using this acceleration factor, life test specification for qualifying that B10 lifetime of the catalytic gas sensor meets the goal lifetime (5 years) was designed.

  • PDF

Durability Evaluation of Platform Safety Step System (승강장 안전발판 시스템의 내구성 평가)

  • Park, Min Heung;Kwak, Hee Man;Kim, Min Ho
    • Journal of Applied Reliability
    • /
    • v.16 no.2
    • /
    • pp.125-133
    • /
    • 2016
  • Purpose: The purpose of this study is to evaluate durability of platform safety step system in railway. Method: We performed finite element analysis & durability analysis of platform safety step system with VPD (Virtual Product Development) techniques and examined the durability standard & qualification life through the rig test during no failure test time in reliability qualification test. We continued to test 1 million cycles in KRS (Korea Railway Standard) for system's robust design performance. Result: FEM analysis results are 14.9MPa & 14.7MPa of pin-joint, pivot and durability analysis result is above 1 million cycles. we calculated theoretically no failure test time 855,000 cycles and through the 1 million cycles durability rig test in KRS standard we confirmed product quality. Conclusion: This platform safety step system was designed very safe in terms of a mechanical strength & durability.

A Study on the Physical Characteristics of the Low-voltage Circuit Breaker Based on the Accelerated Degradation Test (가속 열화 시험에 따른 저압용 차단기의 물리적 특성에 관한 연구)

  • Sin dong, Kang;Jae-Ho, Kim
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.6
    • /
    • pp.1-8
    • /
    • 2022
  • This study analyzed the characteristics of insulation resistance and operating time based on an accelerated degradation test of a low-voltage circuit breaker. The experimental sample used a molded case circuit breaker (MCCB) and an earth leakage circuit breaker (ELCB). After measuring the insulation resistance of the circuit breakers, the leakage current was affected by an external rather than an internal structure. Furthermore, the insulation resistance of the circuit breakers with accelerated degradation was measured using a Megger insulation tester. In the accelerated degradation test, aging times of five, ten, 15, and 20 years were applied according to a temperature derived using the Arrhenius equation. Circuit breakers with an equivalent life of ten, 15, and 20 years had increased insulation resistance compared to those with less degradation time. In particular, the circuit breaker with an equivalent life of ten years had the highest insulation resistance. Component analysis of the circuit breaker manufactured through an accelerated degradation test confirmed that the timing of the increase in insulation resistance and the time of additive loss were the same. Finally, after analyzing the operating time of the circuit breakers with degradation, it was confirmed that the MCCB did not change, but the ELCB breaker failed.

The Study of Accelerated Life Test for Micro Display Device (마이크로 디스플레이 디바이스의 가속수명시험에 관한 연구)

  • 차상목;윤성록;조여욱
    • Journal of Applied Reliability
    • /
    • v.2 no.1
    • /
    • pp.15-22
    • /
    • 2002
  • This paper is concerned about an Accelerated Life Test for Micro Display Device which is being used in a Projection TV, in order to find a failure mode occurred in field in a short time, to identify a major factor to affect a life, and to estimate a mean life. For this purpose, we selected a temperature as a accelerated factor to perform a test and measured degradation of display device using visual inspection and chromaticity table. In the result of Accelerated Life Test, it is confirmed that failure mode is equal to the degradation of display device by vendor and the Temperature is a major factor to affect a failure. Besides, according as the display device is turned to green as degraded, it is identified that the change of the chromaticity value is one method to measure the degree of the degradation . So, we applied the optimal condition, which consider a cost and life to lower the Temperature which is a major factor acquired by the result of ALT, to PTV design

  • PDF