• Title/Summary/Keyword: 1차 에너지

Search Result 1,697, Processing Time 0.029 seconds

Energy Keys Based Scalable Indexing Schemes of Large Color Image Archives (에너지 키에 기초한 대형 칼라 영상 기록물의 계층적 인덱싱 기법)

  • 박대철;강종묵
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2001.06a
    • /
    • pp.225-228
    • /
    • 2001
  • We propose a method which has effective scalable indexing characteristics of large color image archives. Color key and energy key method which uses provides high performance of fast accessing and has almost constant query response time over DH size.

  • PDF

Study on Applicability of Asymmetry V-Cut method in Underground Mine (비대칭 V-cut의 갱내 광산에 대한 적용성 연구)

  • Kim, Jung-Gyu;Jung, Seung-Won;Kim, Jun-Ha;Kim, Jong-Gwan
    • Tunnel and Underground Space
    • /
    • v.31 no.6
    • /
    • pp.520-533
    • /
    • 2021
  • It is necessary to increase the blasting efficiency in order to minimize the economic loss caused when the excavation cross section is reduced due to the stability problem of underground mining development, and for this, a new blasting design is proposed. In this study, the blasting efficiency of the general design in the field, the suggestion designI, which added two columns to production blasting, and the suggestion design II, which added one column to create asymmetry, is compared. Advance rate and fragmentation were selected as the evaluation index of the blasting efficiency. In the case of advance rate, compared to the normal, the suggestionI improved by 6.07% and the suggestionII improved by 4.65%. In the case of fragmentation, based on P80, compared to the normal, the suggestionI reduced about 58% and the suggestionII was about 47%. Accoording to the evaluation index, the suggestion designI shows better blasting efficiency than the suggestion designII. But considering the additional work time and cost required for the suggestion designI due to the insignificant difference in the evaluation index results, the asymmetry V-cut, the suggestion designII, is judged to be a more suitable blasting design for the site.

A Property Analysis on Spatial Distribution of Sea Water Temperature Difference for Site Selection of Ocean Thermal Energy Conversion Plant (해양온도차 발전소의 입지선정을 위한 해수 온도차의 공간적 분포특성 분석)

  • 서영상;장이현;조명희
    • Journal of Energy Engineering
    • /
    • v.8 no.4
    • /
    • pp.567-575
    • /
    • 1999
  • This study found potential ability to generate electric power using difference in water temperature between sea surface water and deep water in the East Sea which includes the East Sea Proper Water with the temperature less than 1$^{\circ}C$ throughout a year without seasonal variation. To quantify the difference in water temperature between sea surface water and deep water in the East Sea. We computed the annual mean ($^{\circ}C$), the annual amplitude ($^{\circ}C$), the annual phase (degree) and the duration time which showed more than 15$^{\circ}C$ temperature difference from the water temperature data using Harmonic analysis during 1961~1997. The best place for generating electric power in the East Sea seems to be the eastward ocean areas (36$^{\circ}$ 05'N, 129$^{\circ}$ 48'E~36$^{\circ}$ 05'N, 130$^{\circ}$ 00E'E) from Pohang city. The annual mean of the difference in water temperature between sea surface water and 500 m depth was 24$^{\circ}$C at the place to generate electric power in August according to the data of 1961~1997. the maximum duration periods with more than 15$^{\circ}C$ temperature difference were 215 days (5/5-12/10) a year in the place mentioned electricity with a stable plan. In the East Sea coastal areas of the Korean peninsula, the average minimum depth to reach the East Sea Proper Water from surface water is 300 m and fluctuates between 250 m and 350 m throughout a year. Further studies could be needed for the utilization of cold water, such as the East Sea Proper Water for energy conversion.

  • PDF

A study on the relationship between the existing building load for the advance ZEB certification system (ZEB 인증제 고도화를 위한 기존 건축물 부하별 연관성 연구)

  • Lee, Hangju;Maeng, Sunyoung;Kim, Insoo;Ahn, Jong-Wook
    • Journal of Energy Engineering
    • /
    • v.27 no.3
    • /
    • pp.21-27
    • /
    • 2018
  • In accordance with the implementation of the Zero Energy Building Certification System, it for the activation and expansion of the private sector is being steadily upgraded. Also The government has set up a step-by-step mandatory roadmap until it is expanded to the private sector, starting with the public sector. We analyzed the energy requirements of existing buildings from 2016 to 2017 and the by load relationships of major factor. Of the existing buildings, 714 buildings in central and southern areas excluding residential buildings such as apartments and officetels were classified and their primary energy requirements were analyzed. As new design technologies are applied, the demand for energy from the passive side is steadily declining. In addition, there is a need to interpret various methods to improve the zero energy building certification standard in the point that the zero energy building pilot project is continuously carried out in relation to the activation of renewable energy supply.

Regional characteristics of renewable energy dissemination program in Korea (국내 신재생에너지 사업의 지역별 특성 고찰)

  • Shin, Youngeun;Yoo, Kyungjin;Cho, Haeyeon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.139.1-139.1
    • /
    • 2011
  • 정부는 국가에너지 기본계획을 통하여 2030년까지 1차 에너지에 대해 신재생에너지 비중을 11%까지 확대하겠다는 목표를 설정하였다. 이에 대한 일환으로 신재생에너지 지방보급 사업 등 지역 별로 신재생에너지에 관한 투자 및 보급이 활발하게 진행되고 있는 상황이다. 더불어, 각 지방자치단체에서도 지역에 맞는 신재생에너지 계획을 수립하여 신재생에너지를 보급하고자 노력하고 있다. 신재생에너지 사업은 지역의 경제발전과 밀접한 연관을 가지고 있기 때문에 그 중요성이 더욱 부각되고 있는 실정이다. 본 연구에서는 우리나라 각 지역별 신재생에너지 계획안을 검토하여 어떠한 에너지원에 중점을 두고 사업을 추진하고 있는지 그 현황을 파악하고자 한다. 또한 이들 지역의 신재생에너지 계획안이 해당 지역의 신재생에너지 잠재량과 같은 지역의 특성을 잘 반영하고 있는지, 해당 지역의 신재생에너지 현황은 어떠한지 에너지기술연구원과 에너지관리공단의 관련 자료를 참고하여 검토할 것이다. 이를 통해 궁극적으로 각 지역의 신재생에너지 계획이 해당 지역이 보유하고 있는 자원(자연자원, 인력자원, 경제적 재원 등)을 효율적으로 활용하고 있는지 분석하고자 한다. 본 연구의 결과는 기존의 지역별 신재생에너지 계획을 평가하는데 사용될 수 있으며, 향후 지역 및 국가단위의 에너지 계획 수립에 참고자료로 활용될 수 있을 것이다.

  • PDF

Development of GHP System Using Industrial Waste Water Source (산업폐수열원이용 GHP 시스템 개발)

  • 장기창;박준택;박성룡
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.11a
    • /
    • pp.53-58
    • /
    • 2002
  • 선진국에서는 산업체의 1차 에너지소비가 전체 에너지소비의 약 30~40%이고, 이 에너지의 약 70~80%가 공정용 열에너지로 사용되고 있다. 이러한 공정용 열의 온도범위를 파악하는 것은 매우 중요하지만 산업공정의 다양성 때문에 평가하기에는 많은 어려움이 따른다. 그러나 일반적으로 산업체 열에너지의 60% 이상은 30$0^{\circ}C$ 이하의 온도이며, 약 20~30%는 15$0^{\circ}C$ 이하이다.(중략)

  • PDF

ESCO Issue 1 - '온실가스.에너지 목표관리제' 도입에 따른 지원체계와 대응 전략

  • 에너지절약전문기업협회
    • The Magazine for Energy Service Companies
    • /
    • s.67
    • /
    • pp.34-41
    • /
    • 2010
  • 지난 9월 28일, 지식경제부 박영준 차관 주재로 '제2차 온실가스 에너지 관리위원회' 회의가 열렸다. 이번회의에서 지식경제부는 소관분야인 산업 발전분야의 '10년 온실가스 에너지 목표관리 업체로 374개를 지정 고시한다고 발표하고, 중소기업의 부담완화를 위해 대 중소상생, 자금 인력지원 등 종합적 지원체계를 마련했다. 목표관리제 시행에 따른 지원체계와 지자체의 효과적인 대응 전략을 살펴본다.

  • PDF

부로일러 초생추에 있어서 박류의 대사 에너지 측정

  • 김춘수;이남형
    • KOREAN POULTRY JOURNAL
    • /
    • v.5 no.1 s.39
    • /
    • pp.100-107
    • /
    • 1973
  • 국산대두박, 수입대두박, 호마박, 채종박, 고추씨박, 임박의 대사에너지가를 4주령의 부로일러 285수를 가지고 지시물법(Indicator method)으로 측정했는데 이때 기본사료는 관용사료를 사용했으며 시험자료의 대치수준은 풍건물 상태로 10$\%$, 20$\%$, 30$\%$였다. 이 시험결과를 요약하면 다음과 같다. 1. Chronmic oxide의 표준 커브는 430mm파장에서 Y=0.430 X였다. 2. 국산대두박의 ME가는 2.405 Kcal/gm, 수입대두박은 2.477 Kcal, 임박은 1,995 K cal, 채종박은 1,682 K cal, 호마박은 1,783 K cal, 고추씨박은 1,290 K cal였다. 3. 질소를 보정한 대사에너지가와 질소를 보정 안한 대사에너지가는 r=0.986의 상관관계를 나타냈다. 4. 시험사료의 대치수준은 대사에너지가에 유의적인 영향이 없었다. 5. 증체량은 대두박구가 호마박구, 고추씨박구에 비해 우수했으며(p<0.05)임박, 채종박구와는 유의차가 없었다. 사료효율은 대두박구, 채종박구, 임박구가 호마박구, 고추씨박구에 비해 유의적으로 좋았고 (p<0.05) 각 박류의 대사에너지가와 사료효율과는 회귀관계를 나타났다.

  • PDF

An Energy Model for IEEE 802.11b based on Transmission Rate (전송률에 기반한 IEEE 802.l1b 에너지 모델)

  • 김태현;차호정
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.10c
    • /
    • pp.124-126
    • /
    • 2004
  • 본 논문은 CAM(Constant Awake Mode), 및 PSM(Power Saving Mode)을 지원하는 IEEE 802.l1b[1] Infrastructure 환경에서 전송 프로토콜이 이동기기의 WNIC(Wireless Network Interface Card) 에너지 소비에 미치는 영향을 분석하고 단위 시간 동안 전송되는 데이터 양에 기반한 IEEE 802.l1b WNIC 에너지 모델을 제안한다. 제안하는 에너지 모델은 IEEE 802.l1b 환경에서 CAM 및 PSM 모드를 사용할때, 실제 측정한 값을 기반으로 설계되었다. 제안된 에너지 모델은 실험을 통하여 정확성을 검증하고, IEEE 802.l1b를 기반으로한 저전력 통신 관련 연구에서 시뮬레이션 시 사용 가능한 에너지 모델임을 밝힌다.

  • PDF