• Title/Summary/Keyword: 1/4 scale model

Search Result 1,200, Processing Time 0.033 seconds

The Behavior and Resistance of Connected-pile Foundations for Transmission Tower from In-situ Lateral Load Tests (송전용 철탑기초의 현장수평재하시험을 통한 연결형 말뚝기초의 거동 및 지지력특성)

  • Kyung, Doo-Hyun;Lee, Jun-Hwan;Paik, Kyu-Ho;Kim, Dae-Hong;Kim, Dae-Hak
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.2
    • /
    • pp.57-70
    • /
    • 2012
  • For soft ground, a pile foundation is typically used as a substructure of transmission tower. However, differential settlement between the foundations can cause structural damage of transmission tower. The connected-pile foundation is a type of group foundation consisting of four foundations connected with beams, and it was suggested in USA and Japan. In this study, a series of 1/8 scale model pile tests were performed to investigate the effect of load direction and stiffness of connecting beam on the responses of connected-pile foundation. As a result, the load capacities of the connected-pile foundation were larger than those of the conventional group pile foundation. For example, under the given test conditions in this paper, the resistibility against differential settlement was improved significantly for connected-pile foundation and its efficiency was maximized when the stiffness of connecting beams is about 25% of the mat foundation.

Three-Dimensional Numerical Magnetohydrodynamic Simulations of Magnetic Reconnection in the Interstellar Medium

  • TANUMA SYUNITI;YOKOYAMA TAKAAKI;KUDOH TAKAHIRO;SHIBATA KAZUNARI
    • Journal of The Korean Astronomical Society
    • /
    • v.34 no.4
    • /
    • pp.309-311
    • /
    • 2001
  • Strong thermal X-ray emission, called Galactic Ridge X-ray Emission, is observed along the Galactic plane (Koyama et al. 1986). The origin of hot ($\~$7 keV) component of GRXE is not known, while cool ($\~$0.8 keV) one is associated with supernovae (Kaneda et al. 1997, Sugizaki et al. 2001). We propose a possible mechanism to explain the origin; locally strong magnetic fields of $B_{local}\;\~30{\mu}G$ heat interstellar gas to $\~$7 keV via magnetic reconnection (Tanuma et al. 1999). There will be the small-scale (< 10 pc) strong magnetic fields, which can be observed as $(B)_{obs} \;\~3{\mu}G$ by integration of Faraday Rotation Measure, if it is localized by a volume filling factor of f $\~$ 0.1. In order to examine this model, we solved three-dimensional (3D) resistive magnetohydrodynamic (MHD) equations numerically to examine the magnetic reconnect ion triggered by a supernova shock (fig.l). We assume that the magnetic field is Bx = 30tanh(y/20pc) $\mu$G, By = Bz = 0, and the temperature is uniform, at the initial condition. We put a supernova explosion outside the current sheet. The supernova-shock, as a result, triggers the magnetic reconnect ion, and the gas is heatd to > 7 keV. The magnetic reconnect ion heats the interstellar gas to $\~$7 keV in the Galactic plane, if it occurs in the locally strong magnetic fields of $B_{local}\;\~30{\mu}G$. The heated plasma is confined by the magnetic field for $\~10^{5.5} yr$. The required interval of the magnetic reconnect ions (triggered by anything) is $\~$1 - 10 yr. The magnetic reconnect ion will explain the origin of X-rays from the Galactic ridge, furthermore the Galactic halo, and clusters of galaxies.

  • PDF

Clinical results of conservative management in patients with full-thickness rotator cuff tear: a meta-analysis

  • Karasuyama, Masaki;Gotoh, Masafumi;Tahara, Keiji;Kawakami, Junichi;Madokoro, Kazuya;Nagamatsu, Takashi;Imai, Takaki;Harada, Nobuya;Kudo, Yu;Shiba, Naoto
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.2
    • /
    • pp.86-93
    • /
    • 2020
  • Background: Several systematic reviews have reported on the conservative treatment of full-thickness rotator cuff tears; however, clinical results of this treatment still remain determined. Methods: PubMed, Cochrane Library, PEDro, and CINAHL databases were systematically searched for randomized clinical trials and observational studies. Two independent researchers reviewed a total of 2,981 articles, 28 of which met the criteria for inclusion in the study. Clinical outcome measures included Constant score, visual analog scale score for pain, range of motion, and short-form 36 questionnaires. The meta-analysis used a linear mixed model weighted with the variance of the estimate. Results: The meta-analysis showed a significant improvement after surgery. Pain score is 26.2 mm (1 month) to 26.4 mm (3 months), and 24.8 mm (12 months) (P<0.05); active abduction: 153.2° (2 months), 159.0° (6 months), 168.1° (12 months) (P<0.05); Constant score: 67.8 points (2 months) to 77.2 points (12 months) (P<0.05); short-form 36 questionnaires "vitality" section: 57.0 points (6 months) to 70.0 points (12 months) (P<0.05). Conclusions: Our data confirmed the effectiveness of conservative treatment in patients with full-thickness rotator cuff tears 12 months post-intervention. The results suggest that conservative treatment for patients with full-thickness rotator cuff tears should be the first line of treatment before considering surgery.

Minimum Temperature Mapping in Complex Terrain Considering Cold Air Drainage (냉기침강효과를 고려한 복잡지형의 최저기온 분포 추정)

  • 정유란;서형호;황규홍;황범석;윤진일
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.4 no.3
    • /
    • pp.133-140
    • /
    • 2002
  • Site-specific minimum temperature forecasts are critical in a short-term decision making procedure for preventive measures as well as a long-term strategy such as site selection in fruits industry. Nocturnal cold air pools frequently termed in mountainous areas under anticyclonic systems are very dangerous to the flowering buds in spring over Korea, but the spatial resolution to detect them exceeds the current weather forecast scale. To supplement the insufficient spatial resolution of official forecasts, we developed a GIS - assisted frost risk assesment scheme for using in mountainous areas. Daily minimum temperature data were obtained from 6 sites located in a 2.1 by 2.1 km area with complex topography near the southern edge of Sobaek mountains during radiative cooling nights in spring 2001. A digital elevation model with a 10 m spatial resolution was prepared for the entire study area and the cold air inflow was simulated for each grid cell by counting the number of surrounding cells coming into the processing cell. Primitive temperature surfaces were prepared for the corresponding dates by interpolating the Korea Meteorological Administration's automated observational data with the lapse rate correction. The cell temperature values corresponding to the 6 observation sites were extracted from the primitive temperature surface, and subtracted from the observed values to obtain the estimation error. The errors were regressed to the flow accumulation at the corresponding cells, delineating a statistically significant relationship. When we applied this relationship to the primitive temperature surfaces of frost nights during April 2002, there was a good agreement with the observations, showing a feasibility of site-specific frost warning system development in mountainous areas.

Taeyoung Submerged-type Membrane Filtration for Advanced Drinking Water Treatment (태영 침지식 막여과 고도정수처리)

  • Yeon, Kyeongho;Cho, Jaebeom;Lee, Yunkyu;Kang, Hojung;Kim, Woogu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.4
    • /
    • pp.15-27
    • /
    • 2013
  • In order to plan out the Daegu G membrane filtration water treatment plant, water quantity, water quality and process stability were evaluated using the field pilot-scale tests, during the six months of continuous operation, including low water temperature period. The field model experiments, which were carried out according to the Installation Criteria of Ministry of Environment, consisted of two series : series 1 - water quality verification, and series 2 - membrane process evaluation. The process water quality met all drinking water standards with less than 0.03 NTU. Moreover, process operation showed a stable membrane pressure with 99% of recovery ratio. This shows that the tests were properly designed in terms of the influence of water loading and temperature. In conclusion, the purpose of this study is to establish core technology for advanced drinking water treatment, through on-going accumulation of engineering and construction know-how.

A study on the enhancement and performance optimization of parallel data processing model for Big Data on Emissions of Air Pollutants Emitted from Vehicles (차량에서 배출되는 대기 오염 물질의 빅 데이터에 대한 병렬 데이터 처리 모델의 강화 및 성능 최적화에 관한 연구)

  • Kang, Seong-In;Cho, Sung-youn;Kim, Ji-Whan;Kim, Hyeon-Joung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.6
    • /
    • pp.1-6
    • /
    • 2020
  • Road movement pollutant air environment big data is a link between real-time traffic data such as vehicle type, speed, and load using AVC, VDS, WIM, and DTG, which are always traffic volume survey equipment, and road shape (uphill, downhill, turning section) data using GIS. It consists of traffic flow data. Also, unlike general data, a lot of data per unit time is generated and has various formats. In particular, since about 7.4 million cases/hour or more of large-scale real-time data collected as detailed traffic flow information are collected, stored and processed, a system that can efficiently process data is required. Therefore, in this study, an open source-based data parallel processing performance optimization study is conducted for the visualization of big data in the air environment of road transport pollution.

Analysis of the Efficiency of National SW R&D Projects Using DEA (DEA를 활용한 SW 국가연구개발사업 효율성 분석)

  • Ro, Seok-Hyun;Cho, Nam-Wook
    • The Journal of Society for e-Business Studies
    • /
    • v.26 no.2
    • /
    • pp.45-59
    • /
    • 2021
  • As software(SW) has been considered as a key driver of the fourth industrial revolution, significant R&D investment has been made by Korean government. Despite the attention and support by the government, systematic analysis on the SW R&D efficiency has not been fully addressed. In this study, the efficiency of SW national research and development projects was analyzed using Data Envelopment Analysis(DEA) techniques. Efficiency was measured from both static and dynamic perspectives based on 1,463 projects conducted by the National IT Industry Promotion Agency(NIPA) from 2008 to 2018. The static efficiency analysis identified the causes of inefficiency as scale and technology problems. As a result of dynamic efficiency analysis, we present a sector-specific response model using an efficiency-stability matrix. This study is meaningful in that efficiency analysis was conducted on the entire SW national R&D project, and static/dynamic efficiency analysis results are expected to be used as a guideline for planning SW national R&D project.

Psychometric Properties of the Korean Version of 12-Item Obsessive-Compulsive Inventory in Accordance With Obsessive-Compulsive Symptom Dimensions in Individuals With Obsessive-Compulsive Disorder (강박장애 환자에서 강박증상차원에 부합하는 12문항 강박증상목록의 심리측정적 특성)

  • Ho Seok Seo;Mina Choi;Seung Jae Lee
    • Anxiety and mood
    • /
    • v.19 no.1
    • /
    • pp.10-18
    • /
    • 2023
  • Objective : The 18-item Obsessive-Compulsive Inventory-Revised (OCI-R) is widely employed to assess symptoms of obsessive-compulsive disorder (OCD). However, this instrument's factor structure does not align with contemporary dimensional models of OCD. Therefore, the objective of this study was to examine psychometric properties of the 12-item Korean OCI (OCI-12) on four obsessive-compulsive symptom dimensions, in patients with OCD. Methods : A total of 157 patients with OCD and 51 healthy controls completed psychological measures, including the OCI-R, Dimensional Obsessive-Compulsive Scale (DOCS), and scales evaluating anxiety and depressive symptoms. Pychometric characteristics of the OCI-12 with three neutralizing and three hoarding items eliminated from the OCI-R, were analyzed. Results : All OCI-12 items registered excellent internal consistency at 0.83. Confirmatory factor analysis revealed strong association between individual items and their proposed latent factors (i.e., subscales). Convergent validity was appropriate. A high correlation was particularly observed for the DOCS score (r=0.71, p<0 .001). Moreover, the OCI-12 was as sensitive as the OCI-R for determining effects of empirically supported treatment for OCD. Conclusion : The OCI-12 is a 12-item measure that adheres to the prevailing 4-factor model of OCD dimensions. Like OCI-R, it possesses good to excellent psychometric properties, including reliability, validity, and sensitivity to treatment.

Implementation of a Simulation Tool for Monitoring Runtime Thermal Behavior (실시간 온도 감시를 위한 시뮬레이션 도구의 구현)

  • Choi, Jin-Hang;Lee, Jong-Sung;Kong, Joon-Ho;Chung, Sung-Woo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.1
    • /
    • pp.145-151
    • /
    • 2009
  • There are excessively hot units of a microprocessor in today's nano-scale process technology, which are called hotspots. Hotspots' heat dissipation is not perfectly conquered by mechanical cooling techniques such as heatsink, heat spreader, and fans; Hence, an architecture-level temperature simulation of microprocessors is evident experiment so that designers can make reliable chips in high temperature environments. However, conventional thermal simulators cannot be used in temperature evaluation of real machine, since they are too slow, or too coarse-grained to estimate overall system models. This paper proposes methodology of monitoring accurate runtime temperature with Hotspot[4], and introduces its implementation. With this tool, it is available to track runtime thermal behavior of a microprocessor at architecture-level. Therefore, Dynamic Thermal Management such as Dynamic Voltage and Frequency Scaling technique can be verified in the real system.

Managing Within-Field Spatial Yield Variation of Rice by Site-Specific Prescription of Panicle Nitrogen Fertilizer

  • Ahn Nguyen Tuan;Shin Jin Chul;Lee Byun-Woo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.4
    • /
    • pp.238-246
    • /
    • 2005
  • Rice yield and protein content have been shown to be highly variable across paddy fields. In order to characterize this spatial variability of rice within a field, two-year experiments were conducted in 2002 and 2003 in a large-scale rice field of $6,600m^2$ In year 2004, an experiment was conducted to know if variable rate treatment (VRT) of N fertilizer, that was prescribed for site-specific management at panicle initiation stage, could reduce spatial variation in yield and protein content of rice while increasing yield compared to conventional uniform N topdressing (UN, 33kg N/ha at PIS) method. VRT nitrogen prescription for each grid was calculated based on the nitrogen (N) uptake (from panicle initiation to harvest) required for target rice protein content of $6.8\%$, natural soil N supply, and recovery of top-dressed N fertilizer. The required N uptake for target rice protein content was calculated from the equations to predict rice yield and protein content from plant growth parameters at panicle initiation stage (PIS) and N uptake from PIS to harvest. This model· equations were developed from the data obtained from the previous two-year experiments. The plant growth parameters for the calculation of the required N were predicted non-destructively by canopy reflectance measurement. Soil N supply for each grid was obtained from the experiment of year 2003, and N recovery was assumed to be $60\%$ according to the previous reports. The prescribed VRT N ranged from 0 to 110kg N/ha with an average of 57kg/ha that was higher than 33 kg/ha of UN. The results showed that VRT application successfully worked not only to reduce spatial variability of rice yield and protein content but also to increase rough rice yield by 960kg/ha. The coefficient of variation (CV) for rice yield and protein content was reduced significantly to $8.1\%$ and $7.1\%$ in VRT from $14.6\%$ and $13.0\%$ in UN, respectively. And also the average protein content of milled rice in VRT showed very similar value of target protein content of $6.8\%$. In conclusion the procedure used in this paper was believed to be reliable and promising method for reducing within-field spatial variability of rice yield and protein content. However, inexpensive, reliable, and fast estimation methods of natural N supply and plant growth and nutrition status should be prepared before this method could be practically used for site-specific crop management in large-scale rice field.