DOI QR코드

DOI QR Code

The Behavior and Resistance of Connected-pile Foundations for Transmission Tower from In-situ Lateral Load Tests

송전용 철탑기초의 현장수평재하시험을 통한 연결형 말뚝기초의 거동 및 지지력특성

  • 경두현 (연세대학교 토목환경공학과) ;
  • 이준환 (연세대학교 토목환경공학과) ;
  • 백규호 (관동대학교 토목공학과) ;
  • 김대홍 (한국전력공사 전력연구원) ;
  • 김대학 (유니콘기술연구소)
  • Received : 2012.01.01
  • Accepted : 2012.02.20
  • Published : 2012.02.29

Abstract

For soft ground, a pile foundation is typically used as a substructure of transmission tower. However, differential settlement between the foundations can cause structural damage of transmission tower. The connected-pile foundation is a type of group foundation consisting of four foundations connected with beams, and it was suggested in USA and Japan. In this study, a series of 1/8 scale model pile tests were performed to investigate the effect of load direction and stiffness of connecting beam on the responses of connected-pile foundation. As a result, the load capacities of the connected-pile foundation were larger than those of the conventional group pile foundation. For example, under the given test conditions in this paper, the resistibility against differential settlement was improved significantly for connected-pile foundation and its efficiency was maximized when the stiffness of connecting beams is about 25% of the mat foundation.

연약지반에 시공되는 송전철탑의 경우 말뚝기초가 주로 사용되나, 부등침하로 인한 철탑구조물의 손상이 유발될 수 있으며, 이에 따라 미국과 일본에서는 4각의 기초를 연결보로 연결한 연결형 기초의 사용을 추천하고 있다. 본 연구에서는 송전철탑에 작용하는 하중조건과 연결보의 강성조건이 연결형 말뚝기초의 수평거동에 미치는 영향을 조사하기 위해서 1/8 규모의 축소모델을 이용한 연결형 말뚝기초의 수평재하시험을 수행하였다. 본 시험결과 연결형 기초는 말뚝기초에 비하여 지지력이 크고 부등변위등의 송전철탑의 안전성을 저해하는 요인에 저항하는 효율적인 기초 형식인 것으로 나타났으며, 특히 연결보의 상대강성에 따른 효과를 분석한 결과 연결보의 강성이 매트의 강성대비 25%에서 연결형 기초의 형식으로 사용의 효율성이 좋은 것으로 나타났다.

Keywords

References

  1. 경두현, 이준환, 백규호, 김대홍 (2011), 점토지반에 근입된 송전 철탑 연결형 기초의 거동 특성 및 지지력결정을 위한 파괴기준, 한국지반공학회 논문집. 제27권 제3호, pp.27-40.
  2. 김정부, 조성배 (1995), 765kV 철탑기초 설계 및 기초재하시험, 대한전기학회 1995년도 추계 학술대회 논문집, pp.447-449.
  3. 일본동경전력 (1988), UHV 기초설계요항(안), 5.4-5.5.
  4. BSI (1986), "British standard code of practice for foundations", BS8004, British Strandard Institution (BSI), London.
  5. Chin, F. V. (1970), "Estimation of the Ultimate load of piles not carried to failure", Proc. of 2nd southest Asian Conference on Soil Engineering, pp.81-90.
  6. Dajin Liu (2003), "Structural Analysis of Combined Footing on Piles", Practice periodical on structure design and construction, ASCE, Vol.8, No.1, pp.22-24. https://doi.org/10.1061/(ASCE)1084-0680(2003)8:1(22)
  7. Dequan Zhou, Hongli Liu (2011), "Experimental comparison study on behavior of combined composite foundation", Applied Mechanics and Materials, Vol.90-93, pp.264-270. https://doi.org/10.4028/www.scientific.net/AMM.90-93.264
  8. Fellenius, B. H. (1980), "The analysis of results from routine pile load tests", Ground Engineering, Vol.13, No.6, pp.19-36.
  9. Fleming, W. G K., Weltman, A. J., Randolph, M. F., and Elson, W. K. (1992), Piling Engineering 2nd Ed., John Wiley and Sons, New York.
  10. IEEE (2001), "IEEE Guide for Transmission Structure Foundation Design and Testing. (Overturning Moment tests)", IEEE Strandard 691-2001.
  11. ISSMFE (1985), "Axial pile loading test-part 1: static loading", Geotechnical Testing Journal, ASTM, Vol.9, No.2, pp79-89.
  12. JEC (1979), "Design Standard for Power Transmission Supports", JEC-127-1979, Standard of the Japanese Electro technical Committee.
  13. JGS (2002), "Standard for Vertical loading test of pile", JGS-1813-2002, Japanese Geotechnial Society.