• 제목/요약/키워드: 1/3 Octave analysis

검색결과 35건 처리시간 0.026초

Radar Probing of Concrete Specimens Using Frequency Domain Filtering (주파수 영역 필터링을 통한 콘크리트 시편 내부 레이더 탐사)

  • 임홍철;이윤식
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • 제6권4호
    • /
    • pp.23-29
    • /
    • 2002
  • Radar method can be effective in probing concrete structures damaged by earthquake. Data analysis is usually performed in time domain, by considering time delay of the wave due to the dielectric constant of concrete. In this study, improved data analysis has been performed using signal processing scheme of spectra analysis and filtering. Three antenna with 900MHz, 1㎓, and 1.5㎓ center frequency were used to detect a steel bar or delamination in specimens for obtaining data, Frequency spectrum was filtered in low pass, high pass, and band pass varying cutoff frequency with 1/3 octave in frequency domain. The most effective cutoff frequency for each frequency has been determined as the range for 2 octave lower to 1 octave higher and 2 octave lower to 1 octave lower. This result provided a basis in improving data analysis capability using frequency domain filtering.

A Study on the Acoustic Characteristics of the American Adults Using Phonetic System for Sasang Constitution (한국성인(韓國成人)의 사상체질음성분석기(絲狀體質音聲分析機)를 이용한 체질별(體質別) 음향특성(音響特性) 연구(硏究))

  • Shin, Mi-Ran;Kim, Dal-Rae;Yoo, Jun-Sang
    • Journal of Sasang Constitutional Medicine
    • /
    • 제19권3호
    • /
    • pp.75-88
    • /
    • 2007
  • 1. Objectives The purpose of this study was to objectively diagnose American male and female's production of two vowels /a, i/ by Sasang Constitution. 2. Methods It was analyzed the constitutional characteristics of the American adults voices with PSSC-2004. of 134 cases of vowels /a, i/ with a duration of $2.5{\sim}3$ seconds were inputted in PSSC-2004 and analyzed into 40 factors. 3. Results and Conclusions 1) APQ In the male group's production of vowel /a/, the Soyangin's APQ(l), APQ(3) and APQ(4) were significantly high compared with those of Taeumin and Soeumin. 2) Shimmer In the male group's production of vowel /a/, Soeumin's Octave1 Shimmer was significantly low compared with that of Taeumin and Soeumin. In the male group's production of vowel /i/, Soeumin's D-Shimmer was significantly low compared with that of Taeumin and Soeumin. In the female group's production of vowel /a/, the Soyangin's C-Shimmer was significantly high compared with that of Taeumin and Soeumin. 3) Octave In the male group's production of vowel /a/, the Soyangin's Octave3, Octave4, Octave5, Octave6 and Octave1 Ratio were significantly high compared with those of Taeumin and Soeumin. In the male group's production of vowels /a, i/, the Soyangin's Octave4 was significantly high compared with that of Taeumin and Soeumin. 4) Energy In the male group's production of vowel /a/, the Soyangin's Time Domain Total Sum /Time Domain Count, Freq Domain Total Sum /cnt(0), 0k-4k Total Sum, Dev., A(A#, C, E, D#, E, F#) tot E, and A(C,, D#, F#) Dev. were significantly high compared with those of Taeumin and Soeumin. In the male group's production of vowel /i/, the Soyangin's Time Domain Total Sum /Time Domain Count, Freq Domain Total Sum /cnt(0) and 0k-4k Total Sum, Dev. were significantly high compared with those of Taeumin and Soeumin. 5) Peak In the male group's production of vowels /a/ and /i/,, the Soyangin's Peak1 Ratio was significantly low compared with that of Taeumin and Soeumin. In the male group's production of vowels /a/ and /i/,, the Soyangin's Peak10 Ratio, Time Domain Peak Total/Total Energy Sum, Time Domain Peak Dev. and Total/Total Dev. Sum were significantly high compared with those of Taeumin and Soeumin. 6) It is necessary to expand the research of the acoustic analysis of American and Korean to other countries in the diagnosis of the Sasang Constitution by using the voice characteristics.

  • PDF

Field Test and Evaluation of Noise from Wind Turbine Generators at Yongdang and Hangwon in Jeju Island (제주도 용당/행원 풍력발전기 현장 소음 실증)

  • Cheong, Cheol-Ung;Jeong, Sung-Su;Cheung, Wan-Sup;Shin, Su-Hyun;Jeon, Se-Jong;Lee, Saeng-Hui
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.818-821
    • /
    • 2005
  • The sound measurement procedures of IEC 61400-11 are applied to field test and evaluation of noise emission from 1.5 MW wind turbine generator (WTG) at Yongdang and 660 kW WTG at Hangwon in Jeju Island. Apparent sound power level, wind speed dependence and third-octave band levels are evaluated for both of WTGs. 1.5 MW WTG at Yongdang is found to emit lower sound power than 660 kW one at Hangwon, which seems to be due to lower rotating speed of the rotor of WTG at Yongdang. Equivalent continuous sound pressure levels (ECSPL) of 660 kW WTG at Hangwon vary more widely with wind speed than those of 1.5 MW WTG at Yongdang. The reason for this is believed to be the fixed blade rotating speed of WTG at Yongdang. One-third octave band analysis of the measured data show that the band components around 400-500 Hz are dominant for 1.5 MW WTG at Yongdang and those around 1K Hz are dominant for 660 kW WTG at Hangwon.

  • PDF

Analysis on Factors Affecting the Acceleration of the Ballasted Track in Kyong-Bu High Speed Line

  • Kim, Man-Cheol
    • International Journal of Railway
    • /
    • 제2권4호
    • /
    • pp.152-163
    • /
    • 2009
  • In this paper, the correlation between the accelerations measured at the track components and the parameters affecting the acceleration is analyzed. To do it, the accelerations of each track component such as rails, sleepers and ballast are measured in Kyong-Bu high-speed Line. The RMS values of the measured accelerations are calculated and the pad stiffness, the longitudinal irregularity, running velocity and the corrugation, are considered as the parameters affecting the acceleration. By using the linear regression, the correlation coefficients are calculated to analyze the relationship between the acceleration characteristics and the parameters. Also, the 1/3 Octave analysis is calculated to analyze the dominant frequency band of the accelerations of the track components.

  • PDF

Field Test and Evaluation of Wind Turbine Noise according to IEC Standards (IEC 규격에 따른 풍력 터빈 소음의 현장 실증)

  • Cheong, Cheol-Ung;Jung, Sung-Su;Cheung, Wan-Sup;Shin, Soo-Hyun;Chun, Se-Jong;Lee, Sang-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 제17회 워크샵 및 추계학술대회
    • /
    • pp.579-582
    • /
    • 2005
  • The sound measurement techniques in IEC 61400-11 are applied to field test and evaluation of noise emission from 1.5 MW wind turbine generator (WTG) at Yongdang-Lee and 650 kW WTG at Hangwon-Lee in Jeju Island. Apparent sound power level, wind speed dependence and third-octave band levels are evaluated for both of WTGs. 1.5 MW WTG at Yongdang is found to emit lower sound power than 660 kW one at Hangwon, which seems to be due to lower rotating speed of the rotor of WTG at Yongdang. Equivalent continuous sound pressure level s (ECSPL) of 650 kW WTG at Hangwon vary more widely with speed than those of 1.5 MW WTG at Yongdang. The reason for this is believed to be the fixed blade-rotating speed of WTG at Yongdang. One-third octave band analysis of the measured data show that the band components around 400-500 Hz are dominant for 1.5 MW WTG at Yongdang and those around 1K Hz are dominant for 660 kW WTG at Hangwon.

  • PDF

Analysis of free field for Acoustic Anechoic Chamber based on Time Stretched Pulse (Time Stretched Pulse를 이용한 무향실 자유음장 분석)

  • Kim, Keon-Wook
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • 제49권4호
    • /
    • pp.111-119
    • /
    • 2012
  • Time Stretched Pulse (TSP) is used for transmitting and analyzing the impulse signal over the designated spatial place. However, if transfer functions of transmitter and receiver are unknown, performance investigation of free field in temporal domain is barely possible due to the overlap between the direct and indirect signal from the space. Generally, the free field or hemi-free field is evaluated by the Annex A of ISO 3745 in which utilizing the inverse square law with one-third octave band signals. In this paper, the author performs analysis of free field via applying TSP with inverse square law and the results are compared with the one-third octave band signals. According to the analysis of deviation between the corresponding signal and inverse square law model, the proposed TSP method provides the comparable performance index to the one-third octave band signal with reduced measuring time. Provided that the pre-whitening can be implementable by employing the speaker and microphone transfer function, further analyses from TSP compression are able to be performed such as multipath separation from time domain data. The anechoic chamber used in this experiment is verified conformance with ISO 3745 for free field and hemi-free field condition for limited frequency of the signal.

A Study on the Charateristics of the Korean Adult Female Sound According to Sasang Constitution Using PSSC with a Sentence (사상체질음성분석기(四象體質音聲分析機)(PSSC)를 통한 한국인 성인여성(成人女性)의 체질별(體質別) 음향특성연구(音響特性硏究) - 단문(短文)을 중심으로 -)

  • Youn, Ji-Young;Yoon, Woo-Young;Cho, Sung-Eon;Wang, Hyang-Lan;Jeon, Jong-Weon;Kim, Dal-Rae;Yoo, Jun-Sang
    • Journal of Sasang Constitutional Medicine
    • /
    • 제18권3호
    • /
    • pp.75-93
    • /
    • 2006
  • 1. Objectives and Methods Sasang Constitutional Medicine is the original Korean Medicine. The purpose of this study was to objectify the diagnosis of Sasang Constitution. 212 Women's sentences were analyzed into 228 factors like Pitch, APQ, Shimmer, Octave and Energy, etc. Women's sentences were classified into 3 categories: total group, under 54 years old group and over 55 years old group. 2. Results 1) In Total group Soyangin's Center feq.(3) was significantly high compared with Taeyangin and Taeumin groups. Taeumin's Pitch2 was significantly high compared with Soeumin and Taeyangin groups. Taeyangin's Pitch S.D. was significantly high compared with Soyangin group. Taeyangin's Octave6 was significantly high compared with Soeumin group. There were no significant differences among constitutional groups in APQ and Shimmer segment. On the point of Energy, Taeyangin's G Tot E(1), G# Tot E(1), G dev.(1), G# dev.(1), G Tot E(2), G# Tot E(2), G dev.(4) and G# dev.(4) were significantly high compared with other groups. Soyangin's A#S.D.(2) was significantly high compared with Taeyangin group. Taeyangin's A#S.D.(3) was significantly high compared with Taeumin group. Taeyangin's F S.D.(5), F# S.D.(5) and Max Average were significantly high compared with Soeumin group. Taeumin's Peak3 and Peak4 were significantly high compared with Taeyangin group. Taeumin's PeakValue1 was significantly high compared with Soeumin group. Taeyangin's PeakValue2 was significantly high compared with Soeumin group. Taeyangin's PeakValue3 and PeakValue5 were significantly high compared with Other groups. 2) In Under 54 years old group, there were no significant differences among constitutional groups in APQ, Shimmer and Octave segment. Taeumin's Center freq.(2) was significantly high compared with Taeyangin and Soyangin groups. Taeumin's Pitch(2) and Pitch(3) were significantly high compared with Taeyangin and Soeumin groups. Taeyangin's and Taeumin's Pitch S.D. were significantly high compared with Soyangin group. Taeyangin's and Soyangin's Octave2 were significantly high compared with Taeumin group. On the point of Energy, Taeyangin's and Soyangin's A# S.D.(2) were significantly high compared with Soeumin group. Taeyangin's and Soyangin's G# dev.(1), G# dev.(2) were significantly high compared with Taeumin group. Taeyangin's and Taeumin's F# S.D.(3) were significantly high compared with Soeumin group. Taeyangin's and Soyangin's Max Average were significantly high compared with Soeumin group. Taeumin's Peak3 was significantly high compared with Taeyangin and Soeumin groups. Taeyangin's and Taeumin's PeakValue2 were significantly high compared with Soeumin group. Taeyangin's and Soeumin's PeakValue3 were significantly high compared with Taeumin group. Taeyangin's and Soyangin's PeakValue5 were significantly high compared with Soeumin group. Taeyangin's and Soyangin's PeakValue9 were significantly high compared with Taeumin group 3) In Over 55 years old group, there were no significant differences among constitutional groups in Pitch, APQ, and Peak segment. Soeumin's F Shimmer(1) and F Shimmer(2) were significantly high compared with Taeyangin and Taeumin groups. Soeumin's G# Shimmer(1) and G# Shimmer(2) were significantly high compared with Soyangin group. Taeyangin's Octave5 and Octave6 were significantly high compared with Soeumin group. On the point of Energy, Soyangin's C S.D., F# S.D.(1), F# S.D.(2) and G dev.(2) were significantly high compared with other groups. Soyangin's F# S.D.(3) was significantly high compared with Taeumin and Soeumin groups. Taeyangin's and Taeumin's G# S.D.(2) and G# S.D.(3) were significantly high compared with Soyangin group 3. Conclusions From above result, there is the possibility of efficient standard guide for constitution diagnosis by analysis of voice

  • PDF

Analysis on Factors Affecting the Vibration of the Ballast Track in Kyeong-Bu High Speed Line (경부고속선 자갈궤도의 진동에 영향을 미치는 인자에 대한 분석)

  • Kim, Man-Cheol
    • Journal of the Korean Society for Railway
    • /
    • 제10권5호
    • /
    • pp.463-472
    • /
    • 2007
  • In this paper, the correlation between the vibration characteristics of the track components and the parameters affecting the vibration is analysed. To do it, the accelerations of each track component such as rails, sleepers and ballast are measured in Kyong-Bu high-speed line. The RMS values of the measured data are calculated and the pad stiffness, the longitudinal irregularity, running velocity and the corrugation, are considered as the parameters in the viewpoint of track. By using the linear regression, the correlation coefficient is calculated to analyse the relationship. Also, the 1/3 Octave analysis is calculated to analyse the dominant frequency band of tile vibrations of the track components.

Noise Evaluation of the Rumble Strips Constructed at Tall Gate of Highway (고속도로 영업소 광장의 럼블스트립 관련 소음평가)

  • Lee, Jae-Jun;Mun, Sung-Ho;An, Deok-Soon;Kwon, Soo-Ahn
    • International Journal of Highway Engineering
    • /
    • 제14권5호
    • /
    • pp.201-206
    • /
    • 2012
  • PURPOSES: This study evaluated a measuring technique for tire-pavement interaction noise that uses a noble close proximity (NCPX) method as well as for noise level measured inside of a car (e.g., Inside Noise Level) in term of rumble strips constructed at a tall gate. METHODS: According to the measurements of NCPX and inside noise level (INL), 1/3 octave band frequency analysis and overall noise level calculation were conducted in order to evaluate noise levels of NCPX and INL, depending on types of rumble strips. RESULTS: The tested sections of general concrete pavement surface and two different types of rumble strips were evaluated, using 1/3 octave band frequency analysis and overall noise level. From the analyzed results, it can be concluded that rumble strips generate a relatively huge noise levels when compared to the concrete pavement surface. CONCLUSIONS: Noting that above 3 dBA different noise levels can let drivers know that they are getting close to toll gate; therefore, they should apply their brakes. Thus, the noise levels of rumble strips are required to be reduced, based on considering the neighbors living near toll gates.