An Experimental Study on Vapor-Liquid Equilibria of HFC and HC Refrigerant Mixtures (탄화수소 및 불화탄화수소 혼합냉매의 기상-액상 평형에 관한 실험적 연구)

  • 강병복;김민수;김영일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.11
    • /
    • pp.1031-1037
    • /
    • 2000
  • Isothermal vapor-liquid equilibrium(VLE) data have been obtained for the systems of propane(R290)+1,1,1,2-tetrafluoroethane(R134a) and 1,1,1,2-tetrafluoroethane(R134a)+isobutane(R60A) in the temperature range of 253.15 to 323.15K. Experiments were performed in a circulation type apparatus by injecting vapor through liquid pool using a magnetic pump. Both systems form azeotropes in the temperature range of this study. The experimental results were estimated with the Peng-Robinson equation of state. When the temperature-dependent binary interaction parameter was used in the Peng-Robinson equation of state, the absolute average deviation of the measured bubble point pressures from the values correlated by the Peng-Robinson equation was 0.65% and 0.78% for R290+R134a and R134a+600a, respectively. Azeotropic compositions for both systems were presented.

  • PDF

Study on HFC-134a Hydrate Formation Rate : according to stirring speed and driving force (HFC-134a 하이드레이트의 형성속도에 관한 연구 : stirring speed, driving force 조건에 따라)

  • Shin, Hyung-Joon;Moon, Dong-Hyun;Seok, Ming-Wang;Lee, Gang-Woo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.554-554
    • /
    • 2009
  • 지구온난화는 범지구적 환경문제로 매우 빠른 속도로 진행되면서 그 심각성을 더해가고 있다. 특히 해수면 상승이나 대형 태풍, 홍수, 가뭄 등의 이상기후가 빈번하게 발생되며 생태계에도 심각한 타격을 주고 있다. 이러한 지구온난화를 유발하는 물질들에 대해 도쿄의정서(Annex A)에 6대 온실가스($CO_2$ (이산화탄소), 메탄($CH_4$), $N_2O$(아산화질소), PFC(불화탄소), HFC(수소화불화탄소), $SF_6$(육불화황))로 정의 하여 규제대상으로 분류하고 있다. $CO_2$를 제외한 Non-$CO_2$ 온실가스들은 배출량이 $CO_2$에 비해 매우 낮지만 GWP(지구온난화지수)가 매우 커 지구온난화에 미치는 영향이 상당하다. 최근 이산화탄소 이외에 지구온난화 문제를 일으키는 온실가스에 대한 많은 관심으로 대상가스의 처리 또는 재활용을 위한 신기술 및 신공정 개발에 박차를 가하고 있다. 온실가스 중 HFCs는 GWP가 1300으로 미량의 배출로도 심각한 기후변화를 일으킬 수 있는 물질로, 우리나라의 경우 1990년 이후 HFCs 배출량 증가율은 연 평균 4.9% ~ 13.8%이다. 국내외 온실가스 처리기술은 대부분 CO2에 대한 연구개발 및 실증화가 지배적이고, non-CO2에 대한 처리기술 개발수준은 미흡할 뿐만 아니라 본 연구 대상인 HFCs 의 경우에는 처리기술 연구개발이 전무하다. 특히 HFCs는 냉매 또는 발포제로 사용되는데 일반적으로 사용 후 특별한 처리과정 없이 대기중으로 배출된다. 본 연구에서는 non-CO2 가스인 HFC-134a 를 대상으로 혼합가스에서 분리 회수를 위해 하이드레이트 기술을 접목시켜 경제적, 친환경적인 기술개발을 목적으로 한다. kinetic 반응장치와 고압반응기 및 magnetic drive system 을 이용하여 stirring speed와 driving force에 따른 HFC-134a 하이드레이트 형성속도의 상관관계를 제시하고자 한다.

  • PDF

Phase Behavior of Poly(methylmethacrylate) (PMMA) in Varions Solvents at High Pressure (고압상태의 다양한 용매 내에서 Poly(methylmethacrylate) (PMMA)의 상거동)

  • Kim, Je-Il;Yoo, Ki-Pung;Lim, Jong-Sung
    • Clean Technology
    • /
    • v.13 no.1 s.36
    • /
    • pp.28-33
    • /
    • 2007
  • We measured cloud points of Poly(methylmethacrylate) (PMMA) in various solvents using the high-pressure variable volume view cell apparatus. The solvents used for dissolving PMMA were chlorodifluoromethane (HCFC-22), dimethylether (DME), 1,1,1-trifluoroethane (HFC-143a), 1,1-difluoroethane (HFC-152a) and 1,1,1,2-tetrafluoroethane (HFC-134a), and the effect of $CO_2$ concentration on the phase behavior of $PMMA+HCFC-22+CO_2$ system and $PMMA+DME+CO_2$ system was observed. PMMA was dissolved well in HCFC-22 from about 340 K, 5MPa and in DME from about 300 K, 28MPa. However, PMMA was not dissolved at all up to 423.15 K, 160MPa in the other fluorine compound such as HFC-l43a, HFC-152a and HFC-134a. PMMA+HCFC-22, $PMMA+HCFC-22+CO_2$ and PMMA+DME systems exhibit the lower critical solution temperature (LCST) behavior, however, $PMMA+DME+CO_2$ system exhibits the upper critical solution temperature (UCST) behavior. In the $CO_2$ mixture, the cloud point pressure of PMMA was increased dramatically proportional to the amount of $CO_2$ added, and from this result, it was known that $CO_2$ could be used as an antisolvent for fabricating PMMA nano-particles. And the cloud point of PMMA could be controlled by changing the concentration of $CO_2$.

  • PDF

Determination of trace impurities of HFC-134a by gas chromatograph with atomic emission detector (GC/AED) (GC/AED를 이용한 HFC-134a의 미량 불순물 분석)

  • Kim, Myeongja;Lim, Jeongsik;Lee, Jinbok;Lee, Jeongsoon
    • Analytical Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.240-251
    • /
    • 2017
  • 1,1,1,2-Tetrafluoroethane (HFC-134a), which is used as refrigerant in air conditioners, has been recently regulated as a greenhouse gas and is recommended for reuse by refining. It is very important to quantitatively analyze trace impurities present in the refrigerant to evaluate the criteria for reuse. In this study, trace impurities including C, H, Cl, and F, which are difficult to quantify because there are no reference materials, were quantitatively analyzed by a gas chromatograph-atomic emission detector (GC/AED); for this analysis, this was preceded by a qualitative analysis with a GC-mass selective detector (GC/MSD). In addition, the AED response was investigated using a hydrocarbon mixed reference material, which was proportional to the number of atoms in the component. Fifteen refrigerant components were detected as trace impurities in HFC-134a by qualitative analysis of trace impurities including C, H, Cl, and F in the samples. Based on the results of the qualitative analysis, quantitative analysis of trace impurities using AED showed that the highest mole fractions were for the $CHClF_2$ component ($45438.38{\mu}mol/mol$) in one sample and for the $C_2H_2ClF_3$ component ($1311.47{\mu}mol/mol$) in another sample. From this study, it has been shown that it is possible for this analytical method to be applied to the qualitative and quantitative analysis of trace compounds in refrigerants, which are difficult to quantify because of the absence of reference materials.

Measurement of Vapor Pressure of HFC-404a and Polyol ester Mixture System (HFC-404a와 Polyol ester 오일 혼합물의 증기압 측정)

  • Park, Young-Moo;Kim, Rock-Hyun
    • Journal of Energy Engineering
    • /
    • v.18 no.3
    • /
    • pp.203-211
    • /
    • 2009
  • Vapor pressure of HFC-404a and polyol ester system were measured at 56 points from 263.15 to 323.15 K and from 0 to 90 mass %polyol ester. It was found that below 273.15 K, the effect of the polyol ester on the vapor pressure was negligible up to 30 mass % polyol ester. The vapor pressure of the system significantly decreased as the mass fraction of polyol ester increased over 50 percent. Raoult's model and Flory-Huggins model were tested for data reduction. Empirical vapor pressure equations were obtained in terms of temperature and mass fraction of polyol ester.

Analysis of demonstration research on solar heat pump system for room and hot water heating in the southern part of South Korea (남부지역의 태양열이용 열펌프식 온수.난방시스템의 실증연구 분석)

  • Sun, Kyung Ho;Kim, Ki Sun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.198.1-198.1
    • /
    • 2010
  • The goal of this study is to measure and compare the performance of solar heat pump for room and hot water heating. To accomplish the goal, solar heat pump with alumium roll bond type evaporator and indoor heat exchanger(condenser) was built and fully instrumented with thermocouples and pressure transducers etc. The test results showed that the COP(coefficient of performance) of HFC-134a($CF_3CH_2F$) were higher than those of CFC-12($CF_2Cl_2$). One "stratospherically safe" new refrigerant is 1,1,1,2-tetrafluoroethane(HFC-134a), which is thermodynamically similar to CFC-12 and considered to be a potential direct replacement for CFC-12 in air-conditioning and refrigeration applications. The solar heat pump system for room heating was designed to show the best efficiency that the room temperature make $18{\sim}20^{\circ}C$ and $23{\sim}25^{\circ}C$ in the southern part of South Korea during November, December, and January.