• Title/Summary/Keyword: 01A99

Search Result 1,158, Processing Time 0.023 seconds

Positive Temperature Coefficient of Resistivity(PTCR) Behavior of Nb2O5 Added Ba0.99(Bi0.5Na0.5)0.01TiO3 Ceramics as a Function of Sintering Time (Nb2O5 첨가와 소결시간에 따른 Ba0.99(Bi0.5Na0.5)0.01TiO3 세라믹스의 PTCR 특성)

  • Oh, Young-Kwang;Choi, Seung-Hun;Yoo, Ju-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.7
    • /
    • pp.559-562
    • /
    • 2011
  • In this study, the effect of $Nb_2O_5$ and sintering time on the positive temperature of coefficient of resistivity (PTCR) behavior of lead free $Ba_{0.99}(Bi_{0.5}Na_{0.5})_{0.01}TiO_3$ (BBNT) ceramics were investigated in order to fabricate a PTC thermistor with high $T_c$ temperature more than $140^{\circ}C$. In particular, BBNT ceramic doped with 0.1mol% $Nb_2O_5$ and sintered at $1350^{\circ}C$ for 4 h has significantly increased Curie temperature ($T_c$) of about $200^{\circ}C$, showed good PTCR behavior of room-temperature resistivity ($\rho_{rt}$) of $40{\Omega}{\cdot}cm$, a high $\rho_{max}/\rho_{min}$ ratio of $43.78{\times}10^3$ and a large resistivity temperature factor (${\alpha}$) of 16.1%/$^{\circ}C$. With increasing addition of $Nb_2O_5$ content, the $\rho_{rt}$ decreased to a minimum value of $40\;{\Omega}cm$ at 0.1mol% $Nb_2O_5$ and the $\rho_{rt}$ increased for x value over 0.1 mol%.

Study on Total Carbohydrate and Dietary Fiber in Domestic Herbs and Chinese Herbs (국내산 및 중국산 십전대보탕 재료의 구조탄수화물과 식이섬유에 관한 연구)

  • Kim Ki-Chul;Kim Ji-Min;Kim Dae-Jin
    • Journal of Life Science
    • /
    • v.15 no.1 s.68
    • /
    • pp.49-54
    • /
    • 2005
  • This study was conducted to determine the total carbohydrate (CHO), nitrogen free extract (NFE), non fiberous carbohydrate (NFC) and ditery fiber (NDF, neutral detergent fiber; TDF, total dietary fiber; IDF, insoluble dietary fiber; SDF, soluble dietary fiber) of 17 kinds of domestic and Chinese herbs. The samples were dried at 60t for 24 hrs and ground to pass a 0.5mm screen. The contents of NFE was ranged from $85.73\%\;to\;57.57\%$, NDF was ranged from $85.72\%\;to\; 29.74\%$, CHO was ranged from $92.68\%\;to\;63.01\%$, TDF was ranged from $87.33\%$to 17.21, IDF was ranged from $86.37\%\;to\;14.56\%$, SDF was ranged from $6.06\%\;to\;0.97\%$ on domestic herbs in dry matter basis. NFE was ranged from $95.33\%\;to\;35.24\%$, NDF was ranged from $71.48\%\;to\;29.74\%$, CHO was ranged from $78.77\%\;to\; 35.24\%$, TDF was ranged from $86.43\%\;to\;16.22\%$, IDF was ranged from $85.98\%\;to\;13.04\%$, SDF was ranged from $4.13\%\;to\;0.45\%$ on Chinese herbs in dry matter. The several components of domestic and Chinese herbs were not significantly of TDF and IDF, but SDF was significantly by tow-tailed test. The correlationship of several herbs were r=0.99 between TDF and IDF (p<0.01), r=0.51 between TDF and SDF (p<0.01)on domestic herbs. The correlationship of 10 kinds herbs r=0.99 between TDF and IDF (p<0.01), r=0.50 between TDF and SDF (p<0.01) on Chinese herbs, respectively.

Electrical and Magnetic Properties in [La0.7(Ca1-xSrx)0.3MnO3)]0.99/(BaTiO3)0.01 Composites

  • Kim, Geun-Woo;Bian, Jin-Long;Seo, Yong-Jun;Koo, Bon-Heun
    • Korean Journal of Materials Research
    • /
    • v.21 no.4
    • /
    • pp.216-219
    • /
    • 2011
  • Perovskite manganites such as $RE_{1-x}A_xMnO_3$ (RE = rare earth, A = Ca, Sr, Ba) have been the subject of intense research in the last few years, ever since the discovery that these systems demonstrate colossal magnetoresistance (CMR). The CMR is usually explained with the double-exchange (DE) mechanism, and CMR materials have potential applications for magnetic switching, recording devices, and more. However, the intrinsic CMR effect is usually found under the conditions of a magnetic field of several Teslas and a narrow temperature range near the Curie temperature ($T_c$). This magnetic field and temperature range make practical applications impossible. Recently, another type of MR, called the low-field magnetoresistance(LFMR), has also been a research focus. This MR is typically found in polycrystalline half-metallic ferromagnets, and is associated with the spin-dependent charge transport across grain boundaries. Composites with compositions $La_{0.7}(Ca_{1-x}Sr_x)_{0.3}MnO_3)]_{0.99}/(BaTiO_3)_{0.01}$ $[(LCSMO)_{0.99}/(BTO)_{0.01}]$were prepared with different Sr doping levels x by a standard ceramic technique, and their electrical transport and magnetoresistance (MR) properties were investigated. The structure and morphology of the composites were studied by X-ray diffraction (XRD) and scanning electronic microscopy (SEM). BTO peaks could not be found in the XRD pattern because the amount of BTO in the composites was too small. As the content of x decreased, the crystal structure changed from orthorhombic to rhombohedral. This change can be explained by the fact that the crystal structure of pure LCMO is orthorhombic and the crystal structure of pure LSMO is rhombohedral. The SEM results indicate that LCSMO and BTO coexist in the composites and BTO mostly segregates at the grain boundaries of LCSMO, which are in accordance with the results of the magnetic measurements. The resistivity of all the composites was measured in the range of 90-400K at 0T, 0.5T magnetic field. The result indicates that the MR of the composites increases systematically as the Ca concentration increases, although the transition temperature $T_c$ shifts to a lower range.

Gastric Reflux on Routine Tc-99m DISIDA Hepatobiliary Scintigraphy (Tc-99m DISIDA 간담도 Scintigraphy상 우연히 발견된 위장역류의 임상적 의의)

  • Lee, Kang-Wook;Lee, Heon-Young
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.3
    • /
    • pp.313-318
    • /
    • 1995
  • Reflux of bile and digestive enzymes from the small bowel and duodenum into stomach has been observed in patients with various gastroduodenal diseases. Tc-99m iminodiacetic acid delivatives hepatobiliary scan has been used as a noninvasive method to detect duodenogastric reflux. Sometimes, gastric reflux can be observed incidentally on routine Tc-99m DISIDA hepatobiliary scintigraphy. To evaluate the clinical meaning of gastric reflux on routine Tc-99m DISIDA hepatobiliary scan, we analyzed 36 patients showed gastric reflux incidentally on the routine Tc-99m DISIDA hepatobiliary scintigraphy from December 1991 to June 1995 in Chungnam National University Hospital. The results were as follows : 1) The gastric reflux was observed in 2.3% of 1,553 cases of routine Tc-99m DISIDA Hepatobiliary scintigraphy for 43 months. 2) Nineteen percent of patients with gastric reflux had the past medical history of operations on stomach or biliary system. And that history was more prevalent in patients with reflux than those without reflux, significantly (p<0.01). 3) On fiberoptic gastroduodenoscopic examination, 87% of the patients with gastric reflux had the gastroduodenal diseases such as gastritis, gastric ulcer, duodenal ulcer, gastric cancer, duodenal cancer and ampullary diverticulosis. We thought that the gastric reflux can be observed considerably in patients without any operation history on stomach or duodenum, although the operation history is more prevalent in patients with gastric reflux than those without reflux, significantly and most of patients with gastric reflux on routine Tc-99m DISIDA scan has various gastroduodenal diseases.

  • PDF

The Identification and Physiological Properties of Lactobacillus plantarum JK-01 Isolated from Kimchi (김치로부터 분리한 Lactobacillus plantarum JK-01의 동정 및 생리적 특성)

  • Cho, Jin-Koo;Li, Guan-Hao;Cho, Sung-Jin;Yoon, Yoh-Chang;Hwang, Seong-Gu;Heo, Kang-Chil;Choe, Il-Shin
    • Food Science of Animal Resources
    • /
    • v.27 no.3
    • /
    • pp.363-370
    • /
    • 2007
  • In order to identify probiotic microorganisms, 25 isolates of Lactobacillus sp. were selected from kimchi based on their growth rates, lactic acid production and salt tolerance. The isolate JK-01 was identified as Lactobacillus plantarum by the API kit and 16S rDNA analysis (99.9% of homology), and named as L. plantarum JK-01. The maximum number of L. plantarum JK-01 was reached at 18 hr fermentation in MRS broth and the pH gradually decreased to 4.5. L. plantarum JK-01 showed high enzyme activities for xylanase, amylase, protease, and phytase on MRS agar plates containing each substrate. L. plantarum JK-01 showed high resistance to acidic pH and bile salts, and grew well even at pH 2.0 and 1.0% bile salt. In particular, L. plantarum JK-01 showed high heat stability as shown by $3.3{\times}10^3$ CFU/mL at $60^{\circ}C$. The isolate showed remarkable antimicrobial activity against E. coli in MRS broth based on its disappearance after 18 hr and clear zone formation using a paper disk assay. These results suggest that L. plantarum JK-01 may be probiotic in nature.

Sol-Gel Synthesis and Transport Properties of $La_{2/3}Sr_{1/3}Mn_{0.99}{^{57}}Fe_{0.01}O_3$Granular Thin Films

  • Shim, In-Bo;Kim, Sung-Baek;Ahn, Geun-Young;Yun, Sung-Roe;Cho, Young-Suk;Kim, Chul-Sung
    • Journal of Magnetics
    • /
    • v.6 no.1
    • /
    • pp.1-4
    • /
    • 2001
  • We have used acetic acids ethanol and distilled water as a solvent to synthesize $La_{2/3}Sr_{1/3}Mn_{0.99}{^{57}}Fe_{0.01}O_3$(LSMFO) precursor. Crack-free LSMFO granular polycrystalline thin films have been deposited on thermally oxidized silicon substrates by spin coaling. The dependence of crystallization, surface morphology, magnetic and transport properties on annealing temperature was investigated. With increasing annealing temperature, the metal-semiconductor (insulator) transition temperature and the magnetic moment decrease while the resistivity increases. The lattice constants remain almost unchanged. For LSMFO thin films, spin-dependent interfacial tunneling and/or scattering magnetoresistance were observed. Our results indicate that the annealing temperature is very important in determining the intrinsic and extrinsic magnetotransport properties.

  • PDF

Comparison of Clinical Usefulness between N-13 Ammonia PET/CT and Tc-99m Sestamibi SPET in Coronary Artery Disease (관상동맥질환에서 N-13 암모니아 PET/CT와 Tc-99m 세스타미비 SPECT의 임상 유용성 비교)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Chun, Kyung-Ah;Won, Kyu-Chang;Lee, Hyung-Woo;Park, Jeong-Sun;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Seop
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.354-361
    • /
    • 2008
  • Purpose: N-13 ammonia uptake and retention in the myocardium is related to perfusion and metabolism. There are several potential advantages of N-13 ammonia positron emission tomography (PET) to detect myocardial ischemia, such as higher spatial resolution, greater counting efficiencies, and robust attenuation correction. But there are few reports comparing Tc-99m myocardial perfusion single photon emission tomography (MPS) and N-13 ammonia PET. We thus compared adenosine stress N-13 ammonia PET/CT and Tc-99m sestamibi MPS in patients with suspected coronary artery stenosis. Materials and Methods: Seventeen patients (male 13 : $63{\pm}11$ years old) underwent adenosine stress N-13 ammonia PET/CT (Discovery ST, GE), Tc-99m sestamibi MPS (dual head gamma camera, Hawkeye, GE) and coronary angiography within 1 week. N-13 ammonia PET/CT and Tc-99m sestamibi MPS images were assessed with a 20-segment model by visual interpretation and quantitative analysis using automatic quantitative software (Myovation, GE). Results: Both sensitivities and specificities of detecting an individual coronary artery stenosis were higher for N-13 ammonia PET/CT than Tc-99m sestamibi MPS (PET/CT: 91%/89% vs MPS: 65%/82%). N-13 ammonia PET/CT showed reversibility in 52% of segments that were considered non-reversibile by Tc-99m sestamibi MPS. In the 110 myocardial segments supplied by the stenotic coronary artery, N-13 ammonia PET/CT showed higher count densities than Tc-99m MPS on rest study (p < 0.01), and the difference of count density between the stress and the rest studies was also larger on N-13 ammonia PET/CT. Conclusion: Adenosine stress N-13 ammonia PET/CT had higher diagnostic sensitivity and specificity, more reversibility of perfusion defects and greater stress/rest uptake differences than Tc-99m sestamibi MPS. Accordingly, N-13 ammonia PET/CT might offer better assessment of myocardial ischemia and viability.

A Study on the burnout of firefighters (소방대원의 소진(Burnout)에 관한 연구)

  • Lee, In-Soo;Choi, Eun-Sook
    • The Korean Journal of Emergency Medical Services
    • /
    • v.4 no.1
    • /
    • pp.47-55
    • /
    • 2000
  • The study was conducted to investigate the burnout of firefighters. The subjects were 223 firefighters in C-Do. The instruments used for this study were a survey of general characteristics(10 items), burnout(23 items). Analysis of data was done by use of mean percentage, t-test, ANOVA, stepwise multiple regression with SAS program. The results of this study are as follows; 1. Burnout according to general characteristics were showed significant difference in job-aptitude(F=6.30, P<.001), health status(F=5.92, P<.001), education(t=6.09, P<.01), working place rotation(t=2.59, P<.01), call number/week(F=3.28, P<.01), job-burden(F=4.45, P<.01), paper-job burden(F=3.87, P<.05). 2. Category score of burnout were showed the higher score in the lowed personal accomplishment(3.29). 3. Category score of burnout according to aptitude were showed difference each other. 4. Predicting factor of burnout were paper-job burden, health status, job-burden(20.99%).

  • PDF

Occurrence and Chemical Composition of Dolomite from Komdok Pb-Zn Deposit (검덕 연-아연 광상의 돌로마이트 산상과 화학조성)

  • Yoo, Bong Chul
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.34 no.2
    • /
    • pp.107-120
    • /
    • 2021
  • The Komdok Pb-Zn deposit, which is the largest Pb-Zn deposit in Korea, is located at the Hyesan-Riwon metallogenic zone in Jiao Liao Ji belt included Paleoproterozoic Macheolryeong group. The geology of this deposit consists of Paleoproterozoic metasedimentary rocks, Jurassic Mantapsan intrusive rocks and Cenozoic basalt. The Komdok deposit which is a SEDEX type deposit occurs as layer ore and vein ore in the Paleoproterozoic metasedimentary rocks. Based on mineral petrography and paragenesis, dolomites from this deposit are classified four types (1. dolomite (D0) as hostrock, 2. early dolomite (D1) associated with tremolite, actinolite, diopside, sphalerite and galena from amphibolite facies, 3. late dolomite (D2) associated with talc, calcite, quartz, sphalerite and galena from amphibolite facies, 4. dolomite (D3) associated with white mica, chlorite, sphalerite and galena from quartz vein). The structural formulars of dolomites are determined to be Ca1.00-1.20Mg0.80-0.99Fe0.00-0.01Zn0.00-0.02(CO3)2(D0), Ca1.00-1.02M0.97-0.99Fe0.00-0.01Zn0.00-0.02(CO3)2(D1), Ca0.99-1.03Mg0.93-0.98Fe0.01-0.05Mn0.00-0.01As0.00-0.01(CO3)2(D2) and Ca0.95-1.04Mg0.59-0.68Fe0.30-0.36Mn0.00-0.01 (CO3)2(D3), respectively. It means that dolomites from Komdok deposit have higher content of trace elements (FeO, MnO, HfO2, ZnO, PbO, Sb2O5 and As2O5) compared to the theoretical composition of dolomite. These trace elements (FeO, MnO, ZnO, Sb2O5 and As2O5) show increase and decrease trend according to paragenetic sequence, but HfO2 and PbO elements no show increase and decrease trend according to paragenetic sequence. Dolomites correspond to Ferroan dolomite (D0, D1 and D2), and Ferroan dolomite and ankerite (D3), respectively. Therefore, 1) dolomite (D0) as hostrock was formed by subsequent diagenesis after sedimentation of Paleoproterozoic (2012~1700 Ma) silica-bearing dolomite in the marine evaporative environment. 2) Early dolomite (D1) was formed by hydrothermal metasomatism origined metamorphism (amphibolite facies) associated with intrusion (1890~1680 Ma) of Paleoproterozoic Riwon complex. 3) Late dolomte (D2) was formed from residual fluid by a decrease of temperature and pressure. and dolomite (D3) in quartz vein was formed by intrusion (213~181 Ma) of Jurassic Mantapsan intrusive rocks.

The Evaluation of Radioimmunoassay kits for Insulin (Insulin 측정용 방사면역측정법 시약의 평가)

  • Shin, Yong Hwan;Kim, Yun Hyun;Lee, Il Kyu;Kim, Ji Young;Seok, Jae Dong;Shin, Suk Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.149-155
    • /
    • 2012
  • Purpose : Serum insulin levels are useful indicator which of reflecting the function of insulin secretion in pancreatic ${\beta}$ cell and diagnosis of diabetes, differentiating the cause of impaired glucose tolerance. Insulin measurement kits have shown some differences in many ways such as test methods as well as quality control. The purpose of this study was to evaluate the diagnostic performance of seven manufacturing companies commercial kits. Materials and Methods : The values of insulin measured by three manufacturing companies (Biosource, Siemens, TFB) with 59 samples in August 2009 were compared with those measured by four manufacturing companies (Immunotech, Izotope, BNIBT, Cisbio) with 68 samples in December 2011. We evaluated precision, recovery rate, dilution test and correlation of serum insulin measurement using seven manufacturing company kits. Statistical program SPSS 12.0 was used for the verification of results. Results : The coefficients variation of the precision on all seven different kits were showed within 5.0%. Recovery rate of Biosource, Siemens, TFB kits on three different levels showed 94.2~103.7%, 99.0~104.6%, 99.7~107.6% respectively. Immunotech, Izotope, BNIBT, Cisbio were 93.5~99.1%, 91.4~99.1%, 99.2~131.0%, 84.8~102.3% respectively. There was strong correlation between the measurement of insulin by Biosource kit and that by two commercial kits, Siemens (R2=0.96), TFB (R2=0.99). There was good correlation between the measurement of insulin by TFB kit and that by three commercial kits, Immunotech (R2=0.97), Izotope (R2=0.96), Cisbio (R2=0.97). In the dilution test performed with more than 200 ${\mu}IU/ml$ high concentration samples, samples with diabetes correctly was measured in all seven manufacturing kits. However, as measured with insulinoma samples TFB, Siemens, Izotope, Cisbio kits were correctly measured, but Biosource and Immunotech kits were measured 47.4 ${\mu}IU/ml$, 72.3 ${\mu}IU/ml$, respectively. Conclusion : Serum Insulin radioimmunoassay kits were showed excellent precision, correlation and good recovery rate. However, some kits were not measured correctly in the high concentration insulin values. when selecting a kit should be considered many factors that cost effectiveness, compatible for automation equipment, high performance kit, the environment for each laboratory such as reaction time and reporting time.

  • PDF