• 제목/요약/키워드: 힘 보조

검색결과 66건 처리시간 0.023초

편마비 다리환자를 위한 보행보조로봇의 발목 2축 힘센서 설계 (Design of Calf Link Force Sensor of Walking Assist Robot of Leg Patients)

  • 최치훈;김갑순
    • 센서학회지
    • /
    • 제26권5호
    • /
    • pp.353-359
    • /
    • 2017
  • This paper describes the design and manufacture of a ankle two-axis force sensor of a walking assist robot for hemiplegic leg patient. The walking assist robot for the hemiplegic leg patient can safely control the robot by detecting whether the foot wearing the walking assist robot is in contact with the obstacle or not. To do so, a two-axis force sensor should be attached to the robot's ankle. The sensor is used to measure the force of a patient's ankle lower part. The two-axis force sensor is composed of a Fx force sensor, a Fy force sensor and a pulley, and they detect the x and y direction forces, respectively. The two-axis force sensor was designed using by FEM(Finite Element Method), and manufactured using by strain-gages. The characteristics experiment of the two-axis force sensor was carried out respectively. The test results indicated that the interference error of the two-axis force sensor was less than 1.2%, the repeatability error and the non-linearity of the two-axis force sensor was less than 0.04% respectively. Therefore, the fabricated two-axis force sensor can be used to measure the force of ankle lower part in the walking assist robot.

그래핀 투명전극을 이용한 태양전지 제작 및 특성연구

  • 유권재;서은경;김철기;김원동;황찬용
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.81-81
    • /
    • 2010
  • 태양광 또는 자연의 힘을 이용한 에너지의 생산은 가까운 미래에 화석연료의 고갈과 이들의 소모로 인해 발행하는 이산화탄소로 인한 지구 온난화등의 문제로 인하여 그 중요성이 점증되고 있는 실정이다. 특히 태양광으로부터 전기에너지를 얻는 발전 방식은 오래전부터 연구되어 왔고 또한 상용화되어 국부적으로 보조 에너지원으로 이용되어 지고 있다. 동작 원리에 따라 이종접합에서 오는 전위차를 이용하는 방법, 동종 물질의 pn접합을 이용하여 기전력을 얻은 방법 및 연료 감응형 종류가 있다. 이 중에서 물질의 이종접합을 이용하는 방법은 아주 오래된 태양전력을 얻는 방식이나 그 동안 연구가 미비하였던 것이 사실이다. 이에 우리는 새로운 재료인 그래핀을 이용하여 산화구리와의 이종접합 태양전지의 제작및 특성을 분석 하였다. 화학기상증착법 (CVD)을 이용해 그래핀을 구리 박편 표면에 성장하였다. 적절한 온도(섭씨 약 1000도)에서 아주 적은 양의 수소 및 메탄을 흘려 주었을때 손쉽게 단일 원자층의 그래핀이 코팅된 구리박편을 얻을 수 있으며, 이 박편을 고온에서 산화 시키면 그래핀은 산화되지 않고 구리만 산화되어 손쉽게 쇼트키타입 태양전지를 얻을 수 있다. 이때 그래핀은 다른 공정 없이 투명전극의 역할을 한다. 간단한 전극을 부착하여 태양전지를 성능을 평가 하였고 그래핀 및 산화구리의 계면효과를 분석하였다. 효율면에서 III-V족 및 실리콘계의 태양전지에 비해 떨어지나 산화구리의 결정화 순도및 산화구리와 금속간의 계면개선 연구를 통해 극복가능 할 것으로 생각된다.

  • PDF

물리적 요인 분석을 통한 벽면 이동 로봇의 성능 개선 연구 (A Study on the Performance Improvement of Wall Climbing Robot using Physical Variable Analysis)

  • 이지빈;정명수;전진성;백종환;봉대근;이지현;김상훈
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2015년도 춘계학술발표대회
    • /
    • pp.1071-1074
    • /
    • 2015
  • 본 논문은 진공을 이용한 흡착방식과 바퀴형 이동방식을 이용하고 환경 탐지용 센서를 부착한 벽면 이동형 로봇의 물리적 해석을 통한 이동 성능 개선에 관한 연구로서, 대형 구조물의 안전 검사 및 위험한 시설물의 보수 작업등을 보조하기 위한 목적이 있다. 로봇의 무게에 따른 중력을 견딜 수 있는 강력한 진공흡착방식과 고성능 모터 제어에 의한 바퀴 이동방식을 혼합하고 효율적으로 평형을 유지 또는 제어하기 위하여 로봇에 미치는 다양한 힘과 모멘트를 분석하고 수식화 하였으며 기존의 수직이동 속도를 개선하기 위한 로봇의 물리적 변수를 추출하여 변수와 이동력간의 관계를 고찰하였다.

골격근 심실의 역학 (Skeletal Muscle Ventricle Mechanics)

  • 오중환
    • Journal of Chest Surgery
    • /
    • 제32권5호
    • /
    • pp.428-432
    • /
    • 1999
  • 배경: 전기적인 자극에 의하여 골격근의 피로현상이 극복됨으로써 골격근을 심장보조장치에 이용할 수 있게 되었다. 인공심장이나 심실보조기구는 에너지원의 전원장치가 크고 거추장스러운 단점이 있어 아직 해결해야될 문제이다. 반면 골격근을 이용한 심실보조장치는 에너지원으로 환자 자신의 골격근 수축력을 이용할 수 있는 장점이 있어 이의 임상응용 가능성을 제시하고자 한다. 대상 및 방법: 8예의 광배근을 이용하여 골격근 심실의 모형을 만들었다. 물이 담긴 라텍스 주머니를 골격근이 한바퀴 반 감싸도록 고안하였고 골격근의 수축압력은 연결된 관을 통하여 변환기에 기록되도록 하였다. 전극은 흉배신경 주위에 설치한 후 Itrel 7420 박동기에 연결하였다. 프로그래머로 박동기를 조절하였으며 3.0Volt, cyclic burst, 0.31초 on time, 6.0초 off time의 자극을 주었다. 라텍스 주머니 내에 액체의 양을 25cc 씩 증가시키면서 전부하의 변화에 따른 골격근 심실의 박출량과 압력 및 수축력을 측정하였다. 결과: 골격근 심실의 전부하가 0인 경우 일회박출량은 76.3ml 이고, 전부하가 점차 증가함에 따라 일회박출량이 감소하는 경향을 보였다. 전부하가 75cc 이상이 되면 일회박출량은 70ml 이하로 감소하는 양상을 볼 수 있었다. 압력을 측정한 결과도 전부하가 75cc 이하인 경우 정상의 혈압과 비슷한 107mmHg 이상의 혈압을 보이고 있으나 전부하가 100cc 이상 증가하는 경우 혈압이 100mmHg 이하로 감소하는 것을 볼 수 있었다. 또한 최대의 골격근 수축력은 50cc의 전부하에서 16.6 W/kg의 힘을 분출하였다. 결론: 골격근 심실은 전부하의 변화에 따라 정상 심장보다도 강한 박출량과 압력의 변화를 관찰할 수 있었으며 임상 응용의 가능성을 볼 수 있었다.

  • PDF

리튬이온 배터리를 적용한 실내용 전동휠체어 주행특성 분석 (Analysis of driving characteristics of electric wheelchair for indoor driving using lithium-ion battery)

  • 김영필;함헌주;홍성희;고석철
    • 한국산학기술학회논문지
    • /
    • 제21권12호
    • /
    • pp.857-866
    • /
    • 2020
  • '이동'이란 사람들이 매 순간 행동하고, 타인과 교류하며 특정 목적을 달성하는 '장소'의 확장 개념으로 이동에 불편함을 느끼는 사회적 교통약자에게 있어 이동보조수단인 휠체어는 신체적·정신적 삶의 질을 향상하는데 아주 큰 영향을 발휘한다. 이러한 휠체어는 수동식 휠체어와 전동식 휠체어로 구분되는데, 수동식 휠체어는 이용자의 팔과 손의 힘으로 앞으로 추진하게 된다. 하지만 전동식 휠체어는 배터리를 통해 모터에 전기에너지를 공급 해 주고, 모터의 회전에 의해 앞으로 추진하게 된다. 전동휠체어는 주로 실외활동을 중점으로 개발되고 있으나 최근에는 일상생활의 주 공간인 실내용 이동보조수단에 대한 개발 요구가 증가하게됨에 따라 실내용 전동휠체어 개발 또한 활발하게 이루어지고 있다. 실내용 이동보조수단의 경우 공간의 특성상 단거리를 반복 주행하므로 본 연구에서는 전동휠체어의 단거리 주행에 따른 리튬이온배터리의 주행특성을 확인하고, 연속주행의 리튬이온배터리 주행특성을 비교분석하였다. 단거리 주행의 경우 리튬이온배터리의 방전종지전압 도달 시 까지 5초 주행 1초 정지를 반복수행하였다. 리튬이온 배터리를 적용한 실내용 전동휠체어의 주행특성을 분석한 결과 실내 이동을 고려한 단거리 주행시험의 경우 연속주행보다 주행시간이 2.8% 짧아진 것을 확인하였다. 실내용 전동휠체어의 회전모터에 인가 된 전류의 경우 실내 이동을 고려한 단거리 주행이 연속주행 보다 15.4% 높게 나타난 것을 확인하였다.

선박용 로터세일 주위의 난류 유동특성에 관한 수치해석적 연구 (Numerical Analysis Study on the Turbulent Flow Characteristics around the Rotor Sail for Vessels)

  • 김정은;조대환;이창용
    • 해양환경안전학회지
    • /
    • 제28권4호
    • /
    • pp.648-656
    • /
    • 2022
  • 국제해사기구(IMO)의 온실가스(GHG) 감축 전략과 같은 환경규제를 강화함에 따라 친환경 선박 및 대체 연료 등 기술 개발이 확대되고 있다. 그의 일환으로 해운사와 조선사를 중심으로 에너지 저감과 풍력 추진 기술을 활용한 선박 추진 기술이 대두되고 있다. 풍력 추진 기술의 확보와 실증 연구를 조선 및 해운 분야에 도입함으로써 친환경 기술을 활용한 고부가가치 시장을 창출할 수 있으며, 운항선박의 연료 소비율을 줄임으로써 연비를 약 6~8 % 정도 향상시켜 GHG의 감축을 기대할 수 있다. 로터 세일(Rotor Sail, RS) 기술은 원형 실린더가 일정한 속도로 회전하여 유체를 통과할 때 실린더의 수직 방향으로 유체역학적 힘을 발생시키는 기술이다. 이를 마그누스 효과(Magnus Effect)라고 하며, 본 연구에서는 선박에 설치된 풍력보조추진 시스템인 RS 주위의 난류 유동특성에 관한 수치해석적 연구를 통하여 추진효율을 높일 수 있는 방안을 제시하고자 하였다. 그래서 RS의 공기 역학적 힘에 영향을 미치는 매개변수로써 속도비(Spin Ratio, SR)와 종횡비(Aspect Ratio, AR) 변화에 따른 양력계수(CL)와 항력계수(CD)를 도출하였고, RS 끝단 플레이트(End Plate, EP) 적용에 따른 RS 주변 유동특성을 비교하였다.

근육 강성도 힘 피드백을 이용한 하지 보조기의 무릎 신전 운동 보조 특성 분석 (Analysis on the Assist Characteristics for the Knee Extension Motion of Lower Limb Orthosis Using Muscular Stiffness Force Feedback)

  • 김경;강승록;정구영;주수종;김남균;권대규
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권3호
    • /
    • pp.217-226
    • /
    • 2010
  • The lower limb orthosis with a pneumatic rubber actuator, which is intended for the assistance and the enhancement of muscular activities of lower limbs was developed in this study. Compared to other knee extension assistive devices being developed by other researchers, our device is designed especially for the elderly people and intended only for slight assistance so that the subjects can keep their muscular strength. For the effectiveness of system, muscular activities of major muscles in lower limbs during sit-to-stand (STS) and squat motion were measured and analyzed. Subjects were performed the STS and squat motion with and without lower limb orthosis. We made comparison muscular activities between with and without lower limb orthosis. Lower limb orthosis was controlled using muscular stiffness force feedback that is controlled by muscular activities of the measured muscle from force sensor. For analysis of muscular activities, electromyography of the subjects was measured during STS and squat motion, and these were measured using MP 150(BIOPAC Systems, Inc.). Muscles of interest were rectus femoris(RF), vastus lateralis(VL), vastus medialis(VM) and vastus intermedius(VI) muscles in lower limbs of the right side. A biodex dynamometer was used to measure the maximal concentric isokinetic strength of the knee extensors of wearing and not wearing orthosis on right side. The test were performed using the concentric isokinetic mode of test with the velocity set at 60°/s for muscles around the knee joints. The experimental result showed that muscular activities in lower limbs wearing orthosis using muscular stiffness force of a vastus medialis muscle was reduced and knee extension torque of an knee joint wearing lower limb orthosis was increased. With this, we confirmed the effectiveness of the developed lower limb orthosis.

Photon Knife 시스템에 근거한 뇌정위 방사선수술에서 표적위치 확인 (Verification of Target Position in Stereotactic Radiosurgery Based on Photon Knife System)

  • 최태진;김진희;김옥배
    • 한국의학물리학회지:의학물리
    • /
    • 제14권2호
    • /
    • pp.99-107
    • /
    • 2003
  • 선형가속기(Mitsubishi, ML15MDX)를 이용한 방사선수술시스템인 Photon Knife에서 Linac-gram을 통해 선속-표적 위치를 확인하여 신뢰성 있는 시술을 유지하도록 하였다. 선속-레이저광 교정 기구를 제작하여 레이저광의 입사점과 사출점을 조사하여 빔의 위치결정에 이용하였다. 선형가속기에 부착한 보조 콜리메이터의 고정을 확인하기 위해 Isocenter에서 5 cm 떨어진 위치에 팔각형 필름지지체를 두도록 제작하고 확인용 필름(Kodak X-omat V2)을 설치하였다. 필름에 선형가속기의 지지체를 45$^{\circ}$씩 회전조사 하여 필름에 나타난 거리로 보조 콜리메이터의 이동을 확인한 결과 실험 오차내에서 이동이 없음을 확인하였다. 임상에 이용한 체위 표시기는 10 mm 쇠구슬 제도와 납인형을 두어 PKRS 시술시 환부의 체위를 쉽게 확인할 수 있도록 고안제작되었다. 앙와위 및 우측 측와위로 조사한 방사선수술에서 표적 위치기에 있는 양측 쇠구슬과 콜리메이터 조사면과의 일치를 LINAC-gram에서 확인한 결과 CT 영상의 표적좌표와 비교해서 평균 0.8$\pm$0.26 mm 의 오차범위에서 시술하였음을 보이므로 방사선조사의 정확성을 알 수 있다. 선형가속기의 Couch 에 임의의 힘을 가했을 때 위치변동은 좌우 $\pm$5 mm, Couch 축방향으로 $\pm$1 mm, 상하로 $\pm$2 mm 이동할 수 있음을 확인하였다. 이상의 결과로 Photon knife 방사선 수술 시스템은 방사선수술 전 환부의 표적과 선속의 일치를 LINAC-gram을 통해 확인할 수 있어 시술의 신뢰도를 높일 수 있을 것으로 생각된다.

  • PDF

힘/토크 센서를 이용한 수술보조로봇의 원격중심운동 직접교시 알고리즘 연구 (Study on Direct Teaching Algorithm for Remote Center Motion of Surgical Assistant Robot using Force/Torque Sensor)

  • 김민효;진상록
    • 로봇학회논문지
    • /
    • 제15권4호
    • /
    • pp.309-315
    • /
    • 2020
  • This study shows a control strategy that acquires both precision and manipulation sensitivity of remote center motion with manual traction for a surgical assistant robot. Remote center motion is an essential function of a laparoscopic surgical robot. The robot has to keep the position of the insertion port in a three-dimensional space, and general laparoscopic surgery needs 4-DoF (degree-of-freedom) motions such as pan, tilt, spin, and forward/backward. The proposed robot consists of a 6-axis collaborative robot and a 2-DoF end-effector. A 6-axis collaborative robot performs the cone-shaped trajectory with pan and tilt motion of an end-effector maintaining the position of remote center. An end-effector deals with the remaining 2-DoF movement. The most intuitive way a surgeon manipulates a robot is through direct teaching. Since the accuracy of maintaining the remote center position is important, direct teaching is implemented based on position control in this study. A force/torque sensor which is attached to between robot and end-effector estimates the surgeon's intention and generates the command of motion. The predefined remote center position and the pan and tilt angles generated from direct teaching are input as a command for position control. The command generation algorithm determines the direct teaching sensitivity. Required torque for direct teaching and accuracy of remote center motion are analyzed by experiments of panning and tilting motion.

마리오 보타의 건축이미지를 이용한 남성장신구 (Men's Jewelry using Mario Botta's Architectural Images)

  • 박승철;유기현
    • 한국콘텐츠학회논문지
    • /
    • 제9권8호
    • /
    • pp.231-236
    • /
    • 2009
  • 남성장신구는 여성장신구의 보조적 역할이나 예물 등으로 국한되어 있다. 또한 디자인 종류도 한정되어 있으며, 디자인 자체가 선진국가의 것을 참조하는 것이 대부분이다. 이러한 남성장신구 디자인 변화를 위해 그 모티브로 건축물을 선택하였다. 건축물은 남성을 대표하는 상징적 성격이 강하다. 힘이 있고 도전적이며 부와 권력을 상징 한다. 이러한 성격을 가진 건축가로는 세계적인 건축가 마리오 보타가 있다. 그의 건축은 혼란한 상황 속에서 자신의 빛깔을 잃지 않고 지역성을 바탕으로 조형적인 형태감과 공간감을 연구한 작가이다. 이에 본 연구는 마리오 보타 건축물의 형태적 이미지와 공간적 이미지를 작게 압축시켜 남성장신구로 연관 재현시킴으로써 보다 구체적이며 현대적인 감각을 표현할 수 있으리라는 의도에서 출발하여 그 가능성을 다각적으로 모색코자 하였다. 이와 같이 마리오 보타의 건축물에서 볼 수 있는 형태적 이미지와 공간적 이미지를 통해 건축물의 아름다움을 재발견하여, 조형성이 강조된 새로운 형태의 남성장신구를 제안하고자 하였다.