Spreading Beam Poastic Hinging Zone of the High-Strength R/C Beam-Column Joints Using the Vertically Anchored Intermediate Reinforcements (수직앵커형 중간철근으로 보강된 고강도 철근콘크리트 보_-기둥 접합부의 소성힌지 확산)

  • 유영찬;이원호;이리형
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.4
    • /
    • pp.169-179
    • /
    • 1995
  • The purpose of this study is to spread beam plastic hinging zone of the high-strength($f'_c=700kg/cm^2$) reinforced concrete beam-column joints away from the column face by vertically anchored intermediate reinforcements. The newly proposed intermediate reinforcements which are vertically anchored by interlinking each intermediate rebars are tested to insure the ductile behavior of R /C beam-column joins. Main variable is the shape of intermediate reinforcements. From the test results, the newly proposed intermediate rebar detail can move arid expand the beam plastic hinging zone about 1.Od from column face and can delay the strength decay of the high-strength R /C beam-column joint. Also energy dissipation capacity of specimen IV-1.OD10 which is reinforced by vertically anchored intermediate rebars about 1.0d is 1.6 times as high as the specimen CM-STAN which is designed by ACI318-89.

The Resistant Capacity of Reinforced Concrete Beam-Column Joints (철근콘크리트 보-기둥 접합부의 내력)

  • Park, Jong-Wook;Kwon, Goo-Jung;Choi, Ha-Young;Kwag, Jin-I;Lee, Jung-Yoon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.10-13
    • /
    • 2011
  • 내진설계의 기본 개념은 보를 기둥보다 약하게 설계하여 보에 소성힌지를 발생시켜 구조물 전체의 큰 변형을 방지하는 것이다. ACI 352R-02에서는 지역의 지진특성에 따라서 접합부의 상세 설계법을 구분하여 적용한다. 하지만 보와 접합부의 내력 차이가 상대적으로 작게 설계된 구조물의 경우 탄성 범위를 유지해야 하는 경우의 접합부에도 파괴가 발생할 가능성이 있다. 횡하중이 작용할 때 접합부 내부는 전단력의 지배를 받게 되고, 전단내력과 부착내력에 따라서 파괴모드가 결정된다. 본 논문에서는 양방향 반복하중이 작용하는 10개의 보-기둥 접합부를 통해서 접합부와 인접보의 전단내력 차이에 따라서 발생하는 파괴모드를 관찰하고 접합부 내의 전단내력 및 부착내력의 감소로 인해 발생하는 부재의 연성에 대해서 관찰하였다.

  • PDF

An Analytical Study for the Stair Joints Constructed with Prefabricated Form System (선시공 조립식 거푸집 공법을 이용한 계단 접합부의 접합방식에 따른 해석적 연구)

  • Lee, Eun-Jin;Jin, Byung-Chang;Chang, Kug-Kwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.301-304
    • /
    • 2008
  • The stair joints constructed with prefabricated system are general method doing structure design at hinge. If you regarded joints to come in contact with a flight of stairs and a slope of stairs as hinge, the moment performance of joints is not in the least moment, so as the bending moment of the stair case is increased, the reinforcement increase. Also the use is decreased because increasing the joint damage of the vibration & fatigue load. No less the reason constructed with pin the stair joints because the construction efficiency of field work is useable. Recently, they are considering the construction efficiency, while the semi-rigid detail for bending performance of joints is proposed, but for now they don't reflect the detail. Therefore, we proposed that reflecting the method at design semi-rigid joints. We compared the moment performance with the stair joints designed at the rigid joints, semi-rigid joints and pin joints. The nonlinear behavior of staircase core statically indeterminate structure. The result of research is that a bending stiffness modulus bring to reflect the semi-rigid performance, the performance of the semi-rigid joint is better than pin joints, and that is judged the system better seismic and vibration performance because have excellent ductility more than rigid joint.

  • PDF

Full Strength Capacity Connection Design for Medium-Low Rise Braced Steel Structure (가새 골조를 가진 중·저층 건물 접합부의 전강도 설계)

  • Shin, Jeong-Cheol;Sun, Sung-Min;Chung, Young-Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.1
    • /
    • pp.1-12
    • /
    • 2011
  • Due to the concept of "full-strength capacity connection," the pushover analysis method became an issue in designing steel connections. It is difficult to apply practically, however, because engineers are unfamiliar with such method. Moreover, there have been insufficient representative studies on them because most of the past pertinent studies were performed based on high-rise and/or virtual structures. As such, for this study, an actual(now in process) steel structure, a medium-low-rise industrial building, was selected. To perform pushover analysis, it was suggested that lateral load patterns be used in a simple and clear manner for three- and two-dimensional analysis models. A new hinge property was also suggested to prevent erroneous connection design results that can occur in the design process. The suggested load patterns showed almost the same results regardless of the model that was used, from which the obtained load patterns were different. This result implies the validity of the suggested load patterns. As for the suggested hinge property, the structural analysis yielded sound and reasonable results, which confirmed the validity of the proposed hinge property.

Inelastic Time History Analysis of an Unbraced 5-Story Steel Framed Structure for Arrangement of Semi-Rigid Connection (반강접 접합부 배치에 따른 비가새 5층 철골골조구조물의 비탄성 시간이력해석)

  • Kang, Suk-Bong;Kim, Sin-Ae
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.4
    • /
    • pp.313-324
    • /
    • 2010
  • In this study, an unbraced five-story steel-framed structure was designed in accordance with KBC2005 to understand the features of structural behavior for the arrangement of semi-rigid connections. An inelastic time history analysis of structural models was performed, wherein all the connections were idealized as fully rigid and semi-rigid. Additionally, horizontal and vertical arrangements of semi-rigid connections were used for the models. A fiber model was utilized for the moment-curvature relationship of a steel beam and a column, a three-parameter power model for the moment-rotation angle of the semi-rigid connection, and a three-parameter model for the hysteretic behavior of a steel beam, column, and connection. The base-shear force, top displacement, story drift, required ductility for the connection, maximum bending moment of the column, beam, and connection, and distribution of the plastic hinge were investigated using four earthquake excitations with peak ground acceleration for a mean return period of 2,400 years and for the maximum base-shear force in the pushover analysis of a 5% story drift. The maximum base-shear force and story drift decreased with the outer vertical distribution of the semi-rigid connection, and the required ductility for the connection decreased with the higher horizontal distribution of the semi-rigid connection. The location of the maximum story drift differed in the pushover analysis and the time history analysis, and the magnitude was overestimated in the pushover analysis. The outer vertical distribution of the semi-rigid connection was recommended for the base-shear force, story drift, and required ductility for the connection.

Pushover Analysis of an Unbraced 5-Story Steel Framed Structure for Arrangement of Semi-Rigid Connection (반강접 접합부 배치에 따른 비가새 5층 철골골조구조물의 비탄성 정적해석)

  • Kang, Suk-Bong;Kim, Sin-Ae
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.4
    • /
    • pp.325-334
    • /
    • 2010
  • In this study, an unbraced five-story steel-framed structure was designed in accordance with KBC2005 to understand the features of structural behavior for the arrangement of semi-rigid connections. A pushover analysis of the structural models was performed, wherein all the connections were idealized as fully rigid and semi-rigid. Additionally, horizontal and vertical arrangements of the semi-rigid connection were adopted for the models. A fiber model was utilized for the moment-curvature relationship of the steel beam and the column, and a three-parameter power model was adopted for the moment-rotation angle of the semi-rigid connection. The top displacement, base-shear force, required ductility for the connection, sequence of the plastic hinge, and design factors such as the overstrength factor, ductility factor, and response modification coefficient were investigated using the pushover analysis of a 2D structure subjected to the equivalent static lateral force of KBC2005. The partial arrangement of the semi-rigid connection was found to have secured higher strength and lateral stiffness than that of the A-Semi frame, and greater ductility than the A-Rigid frame. The TSD connection was found suitable for use for economy and safety in the sample structure.

Inelastic Time History Analysis of a Five-Story Steel Framed Structure Considering Rigidity of TSD Connection (TSD 접합부의 강성을 고려한 5층 철골골조구조물의 비탄성 시간이력해석)

  • Kang, Suk-Bong;Lee, Jae-Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.3
    • /
    • pp.281-291
    • /
    • 2010
  • In this study, a five-story steel frame was designed in accordance with KBC2005 to evaluate the effects of the beam-column connection on the structural behavior. The connections were designed as fully rigid and semi-rigid. The fiber model was used to describe the moment-curvature relationship of the steel beam and the column, the power model for the moment-rotation angle of the semi-rigid connection and the three-parameter model for the hysteretic behavior of the steel beam, column, and connection. The structure was idealized as separate 2-D frames and as connected 2-D frames. The peak ground accelerations of four earthquake records were modified in a time-history analysis for the levels of the mean return period and for the maximum base-shear force in a pushover analysis. The top story displacement, base-shear force, story drift, demanded ductility ratio for the semi-rigid connection, maximum bending moment of the column, beam, and connection, and distribution of the plastic hinge were examined in the time-history analysis. The frame with the semi-rigid connection yielded a lower base-shear force, less magnitude, and increasing ratio in the bending moment of the column, beam, and connection than the frame with a fully rigid connection. The TSD connection was deemed to have secured the economy and safety of the sample structure that was subjected to seismic excitation for the Korean design level.

Hysteretic Behavior and Seismic Resistant Capacity of Precast Concrete Beam-to-Column Connections (프리캐스트 콘크리트 보-기둥 접합부의 이력거동 및 내진성능)

  • Choi, Hyun-Ki;Choi, Yun-Cheul;Choi, Chang-Sik
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.61-71
    • /
    • 2010
  • Five half-scale beam-to-column connections in a precast concrete frame were tested with cyclic loading that simulated earthquake-type motions. Five half -scale interior beam-column assemblies representing a portion of a frame subjected to simulated seismic loading were tested, including one monolithic specimen and four precast specimens. Variables included the detailing used at the joint to achieve a structural continuity of the beam reinforcement, and the type of special reinforcement in the connection (whether ECC or transverse reinforcement). The specimen design followed the strong-column-weak-beam concept. The beam reinforcement was purposely designed and detailed to develop plastic hinges at the beam and to impose large inelastic shear force demands into the joint. The joint performance was evaluated on the basis of connection strength, stiffness, energy dissipation, and drift capacity. From the test results, the plastic hinges at the beam controlled the specimen failure. In general, the performance of the beam-to-column connections was satisfactory. The joint strength was 1.15 times of that expected for monolithic reinforced concrete construction. The specimen behavior was ductile due to tensile deformability by ECC and the yielding steel plate, while the strength was nearly constant up to a drift of 3.5 percent.

A study on the ductile capacity of Reinforced concrete beam-column joint subjected to cyclic load (반복하중을 받는 철근콘크리트 보-기둥 접합부 연성능력에 대한 연구)

  • Park, Jong-Wook;Woo, Jae-Hyun;Lee, Jung-Yoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.121-122
    • /
    • 2010
  • In this research, reinforced concrete beam-column joint is examined. The main purpose of the research is assessment of influence the beam longitudinal reinforcement slippage to the joint shear and ductile capacity caused by bond decrement as a result of plastic hinges in adjacent beam.