• Title/Summary/Keyword: 히스토그램 수정

Search Result 38, Processing Time 0.035 seconds

A Study on Object Detection Algorithm for Abandoned and Removed Objects for Real-time Intelligent Surveillance System (실시간 지능형 감시 시스템을 위한 방치, 제거된 객체 검출에 관한 연구)

  • Jeon, Ji-Hye;Park, Jong-Hwa;Jeong, Cheol-Jun;Kang, In-Goo;An, Tae-Ki;Park, Goo-Man
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.1C
    • /
    • pp.24-32
    • /
    • 2010
  • In this paper we proposed an object tracking system that detects the abandoned and removed objects, which is to be used in the intelligent surveillance applications. After the GMM based background subtraction and by using histogram method, the static region is identified to detect abandoned and removed objects. Since the system is implemented on DSP chip, it operates in realtime and is programmable. The input videos used in the experiment contain various indoor and outdoor scenes, and they are categorized into three different complexities; low, midium and high. By 10 times of experiment, we obtained high detection ratio at low and medium complexity sequences. On the high complexity video, successful detection ratio was relatively low because the scene contains crowdedness and repeated occlusion. In the future work, these complicated situation should be solved.

An Algorithm for Detecting Residual Quantity of Ringer's Solution for Automatic Replacement (링거 자동 교체를 위한 잔량 검출 알고리즘)

  • Kim, Chang-Wook;Woo, Sang-Hyo;Zia, Mohy Ud Din;Won, Chul-Ho;Hong, Jae-Pyo;Cho, Jin-Ho
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.13 no.1
    • /
    • pp.30-36
    • /
    • 2008
  • Recently, ere are many researches to improve the quality of e medical service such as Point of care (POC). To improve the quality of the medical service, not only good medical device but also more man power is required. Especially, the number of nurses are very few in Korea that is almost the lowest rank compared to OECD countries. If the simple repetition works of the nurse could be removed, it is possible to use the skillful nurse for other works and provide better quality services. There are many simple repetition works which the nurses have to do, such as replacing the ringer's solution. To replace the ringer's solution automatically, it is necessary to detect residual quantity of the ringer's solution. In this paper, image processing is used to detect the residual quantity of ringer's solution, and modified self quotient image (SQI) algorithm is used to strong background lights. After modified SQI algorithm, the simple histogram accumulation is done to find the residual quantity of the ringer's solution. The implemented algorithm could be use to replace the ringer's solution automatically or alarm to the nurses to replace the solution.

  • PDF

Internal Mammary Lymph Node Irradiation after Breast Conservation Surgery: Radiation Pneumonitis versus Dose-Volume Histogram Parameters (유방보존술 후 내유림프절 방사선 조사: 방사선 폐렴과 체적-선량 히스토그램 변수들)

  • Kim, Joo-Young;Lee, Ik-Jae;Keum, Ki-Chang;Kim, Yong-Bae;Shim, Su-Jung;Jeong, Kyoung-Keun;Kim, Jong-Dae;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.261-267
    • /
    • 2007
  • Purpose: To evaluate the association between radiation pneumonitis and dose-volume histogram parameters and to provide practical guidelines to prevent radiation pneumonitis following radiotherapy administered for breast cancer including internal mammary lymph nodes. Materials and Methods: Twenty patients with early breast cancer who underwent a partial mastectomy were involved in this study. The entire breast, supraclavicular lymph nodes, and internal mammary lymph nodes were irradiated with a dose of 50.4 Gy in 28 fractions. Radiation pneumonitis was assessed by both radiological pulmonary change (RPC) and by evaluation of symptomatic radiation pneumonitis. Dose-volume histogram parameters were compared between patients with grade <2 RPC and those with grade ${\geq}$2 RPC. The parameters were the mean lung dose, V10 (percent lung volume receiving equal to and more than 10 Gy), V20, V30, V40, and normal tissue complication probability (NTCP). Results: Of the 20 patients, 9 (45%) developed grade 2 RPC and 11 (55%) did not develop RPC (grade 0). Only one patient developed grade 1 symptomatic radiation pneumonitis. Univariate analysis showed that among the dose-volume histogram parameters, NTCP was significantly different between the two RPC grade groups (p<0.05). Fisher's exact test indicated that an NTCP value of 45% was appropriate as an RPC threshold level. Conclusion: This study shows that NTCP can be used as a predictor of RPC after radiotherapy of the internal mammary lymph nodes in breast cancer. Clinically, it indicates that an RPC is likely to develop when the NTCP is greater than 45%.

Color Image Enhancement Based on an Improved Image Formation Model (개선된 영상 생성 모델에 기반한 칼라 영상 향상)

  • Choi, Doo-Hyun;Jang, Ick-Hoon;Kim, Nam-Chul
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.6 s.312
    • /
    • pp.65-84
    • /
    • 2006
  • In this paper, we present an improved image formation model and propose a color image enhancement based on the model. In the presented image formation model, an input image is represented as a product of global illumination, local illumination, and reflectance. In the proposed color image enhancement, an input RGB color image is converted into an HSV color image. Under the assumption of white-light illumination, the H and S component images are remained as they are and the V component image only is enhanced based on the image formation model. The global illumination is estimated by applying a linear LPF with wide support region to the input V component image and the local illumination by applying a JND (just noticeable difference)-based nonlinear LPF with narrow support region to the processed image, where the estimated global illumination is eliminated from the input V component image. The reflectance is estimated by dividing the input V component image by the estimated global and local illuminations. After performing the gamma correction on the three estimated components, the output V component image is obtained from their product. Histogram modeling is next executed such that the final output V component image is obtained. Finally an output RGB color image is obtained from the H and S component images of the input color image and the final output V component image. Experimental results for the test image DB built with color images downloaded from NASA homepage and MPEG-7 CCD color images show that the proposed method gives output color images of very well-increased global and local contrast without halo effect and color shift.

Hepatic Vessel Segmentation using Edge Detection (Edge Detection을 이용한 간 혈관 추출)

  • Seo, Jeong-Joo;Park, Jong-Won
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.3
    • /
    • pp.51-57
    • /
    • 2012
  • Hepatic vessel tree is the key structure for hepatic disease diagnosis and liver surgery planning. Especially, it is used to evaluate the donors' and recipients' liver for the LDLT(Living Donors Liver Transplantation) and estimate the volumes of left and right hepatic lobes for securing their life in the LDLT. In this study, we propose a method to apply canny edge detection that is not affected by noise to the liver images for automatic segmentation of hepatic vessels tree in contrast abdominal MDCT image. Using histograms and average pixel values of the various liver CT images, optimized parameters of the Canny algorithm are determined. It is more time-efficient to use the common parameters than to change parameters manually according to CT images. Candidates of hepatic vessels are extracted by threshold filtering around the detected the vessel edge. Finally, using a system which detects the true-negatives and the false-positives in horizontal and vertical direction, the true-negatives are added in candidate of hepatic vessels and the false-positives are removed. As a result of the process, the various hepatic vessel trees of patients are accurately reconstructed in 3D.

Incase of Same Region Treatment by using a Tomotherapy and a Linear Accelerator Absorbed Dose Evaluation of Normal Tissues and a Tumor (토모테라피와 선형가속기를 이용한 동일 부위의 치료 시 종양 및 정상조직의 흡수선량 평가)

  • Cheon, Geum-Seong;Kim, Chang-Uk;Kim, Hoi-Nam;Heo, Gyeong-Hun;Song, Jin-Ho;Hong, Joo-Yeong;Jeong, Jae-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.97-103
    • /
    • 2010
  • Purpose: Treating same region with different modalities there is a limit to evaluate the total absorbed dose of normal tissues. The reason is that it does not support to communication each modalities yet. In this article, it evaluates absorbed dose of the patients who had been treated same region by a tomotherapy and a linear accelerator. Materials and Methods: After reconstructing anatomic structure with a anthropomorphic phantom, administrate 45 Gy to a tumor in linac plan system as well as prescribe 15 Gy in tomotherapy plan system for make an ideal treatment plan. After the plan which made by tomoplan system transfers to the oncentra plan system for reproduce plan under the same condition and realize total treatment plan with summation 45 Gy linac treatment plan. To evaluate the absorbed dose of two different modalities, do a comparative study both a simple summation dose values and integration dose values. Then compare and analyze absorbed dose of normal tissues and a tumor with the patients who had been exposured radiation by above two differents modalities. Results: The result of compared data, in case of minimum dose, there are big different dose values in spleen (12.4%). On the other hand, in case of the maximum dose, it reports big different in a small bowel (10.2%) and a cord (5.8%) in head & neck cancer patients, there presents that oral (20.3%), right lens (7.7%) in minimum dose value. About maximum dose, it represents that spinal (22.5), brain stem (12%), optic chiasm (8.9%), Rt lens (11.5%), mandible (8.1%), pituitary gland (6.2%). In case of Rt abdominal cancer patients, there represents big different minimum dose as Lt kidney (20.3%), stomach (8.1%) about pelvic cancer patients, it reports there are big different in minimum dose as a bladder (15.2%) as well as big different value in maximum dose as a small bowel (5.6%), a bladder (5.5%) in addition, making treatment plan it is able us to get. Conclusion: In case of comparing both simple summation absorbed dose and integration absorbed dose, the minimum dose are represented higher as well as the maximum dose come out lower and the average dose are revealed similar with our expected values data. It is able to evaluate tumor & normal tissue absorbed dose which could had been not realized by treatment plan system. The DVH of interesting region are prescribed lower dose than expected. From now on, it needs to develop the new modality which are able to realize exact dose distribution as well as integration absorbed dose evaluation in same treatment region with different modalities.

  • PDF

Evaluating efficiency of Vertical MLC VMAT plan for naso-pharyngeal carcinoma (비인두암 Vertical MLC VMAT plan 유용성 평가)

  • Chae, Seung Hoon;Son, Sang Jun;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.127-135
    • /
    • 2021
  • Purpose : The purpose of the study is to evaluate the efficiency of Vertical MLC VMAT plan(VMV plan) Using 273° and 350° collimator angle compare to Complemental MLC VMAT plan(CMV plan) using 20° and 340° collimator angle for nasopharyngeal carcinoma. Materials & Methods : Thirty patients treated for nasopharyngeal carcinoma with the VMAT technique were retrospectively selected. Those cases were planned by Eclipse, PO and AcurosXB Algorithm with two 6MV 360° arcs and Each arc has 273° and 350° of collimator angle. The Complemental MLC VMAT plans are based on existing treatment plans. Those plans have the same parameters of existing treatment plans but collimator angle. For dosimetric evaluation, the dose-volumetric(DV) parameters of the planning target volume (PTV) and organs at risk (OARs) were calculated for all VMAT plans. MCSv(Modulation complexity score of VMAT), MU and treatment time were also compared. In addition, Pearson's correlation analysis was performed to confirm whether there was a correlation between the difference in the MCSv and the difference in each evaluation index of the two treatment plans. Result : In the case of PTV evaluation index, the CI of PTV_67.5 was improved by 3.76% in the VMV Plan, then for OAR, the dose reduction effect of the spinal cord (-14.05%) and brain stem (-9.34%) was remarkable. In addition, the parotid glands (left parotid : -5.38%, right : -5.97%) and visual organs (left optic nerve: -4.88%, right optic nerve: -5.80%, optic chiasm : -6.12%, left lens: -6.12%, right lens: -5.26%), auditory organs (left: -11.74%, right: -12.31%) and thyroid gland (-2.02%) were also confirmed. The difference in MCSv of the two treatment plans showed a significant negative (-) correlation with the difference in CI (r=-0.55) of PTV_54 and the difference in CI (r=-0.43) of PTV_48. Spinal cord (r=0.40), brain stem (r=0.34), and both salivary glands (left: r=0.36, right: r=0.37) showed a positive (+) correlation. (For all the values, p<.05) Conclusion : Compared to the CMV plan, the VMV plan is considered to be helpful in improving the quality of the treatment plan by allowing the MLC to be modulated more efficiently

Automatic Text Extraction from News Video using Morphology and Text Shape (형태학과 문자의 모양을 이용한 뉴스 비디오에서의 자동 문자 추출)

  • Jang, In-Young;Ko, Byoung-Chul;Kim, Kil-Cheon;Byun, Hye-Ran
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.8 no.4
    • /
    • pp.479-488
    • /
    • 2002
  • In recent years the amount of digital video used has risen dramatically to keep pace with the increasing use of the Internet and consequently an automated method is needed for indexing digital video databases. Textual information, both superimposed and embedded scene texts, appearing in a digital video can be a crucial clue for helping the video indexing. In this paper, a new method is presented to extract both superimposed and embedded scene texts in a freeze-frame of news video. The algorithm is summarized in the following three steps. For the first step, a color image is converted into a gray-level image and applies contrast stretching to enhance the contrast of the input image. Then, a modified local adaptive thresholding is applied to the contrast-stretched image. The second step is divided into three processes: eliminating text-like components by applying erosion, dilation, and (OpenClose+CloseOpen)/2 morphological operations, maintaining text components using (OpenClose+CloseOpen)/2 operation with a new Geo-correction method, and subtracting two result images for eliminating false-positive components further. In the third filtering step, the characteristics of each component such as the ratio of the number of pixels in each candidate component to the number of its boundary pixels and the ratio of the minor to the major axis of each bounding box are used. Acceptable results have been obtained using the proposed method on 300 news images with a recognition rate of 93.6%. Also, my method indicates a good performance on all the various kinds of images by adjusting the size of the structuring element.