• Title/Summary/Keyword: 흡착 동역학

Search Result 43, Processing Time 0.015 seconds

Development of Optimum PAC Dose Prediction Program using $^{14}C$-radiolabled MIB and HSDM ($^{14}C$-radiolabeled MIB와 HSDM을 이용한 최적 PAC 투입량 예측프로그램의 개발)

  • Kim, Young-Il;Bae, Byung-Uk;Kim, Kyu-Hyoung;Hong, Hyun-Su;Westerhoff, Paul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.10
    • /
    • pp.1123-1128
    • /
    • 2005
  • NIB(methylisoborneol) is an earthy/musty odor compound produced as a second metabolite by cyanobacteria and actinomycetes. MIB is not removed by conventional water treatment(coagulation, sedimentation, filtration) and its presence in tap water, even at low ng/L levels, can result in consumer complaints. PAC(powdered activated carbon) can effectively remove MIB when the correct dose is applied. But, since most operators in water treatment plants apply a PAC dose and then adjust that dose depending on direct observation (odor detection) after treatment, the result is often under-dose or eve,-dose. In this study, kinetic and isotherm tests using $^{14}C$-radiolabeled MIB were performed to determine coefficients for the HSDM(homogeneous surface diffusion model), including liquid film mass transfer coefficient($K_f$) and surface diffusion coefficient ($D_s$). The HSDM gave a reasonable fit and allowed prediction with the experimental data. Base on the HSDM, the authors developed an optimum PAC dose prediction program using the Excel spreadsheet. When the developed program was applied at two water treatment plants, the PAC dose based on the experience of operators in the water treatment plant was significantly different from that recommended by the newly developed program. If operators are willing to use the optimum PAC dose prediction program, it should solve dosing problems.

Mathematical Modelling of Phenol Desorption from Spent Activated Carbon by Acetone (활성탄에 흡착된 페놀의 아세톤 탈착 모델에 대한 연구)

  • Kim, Seungdo;Oh, Young-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.12
    • /
    • pp.2115-2123
    • /
    • 2000
  • This research was designed to investigate the mathematical model and kinetics of phenol desorption from spent activated carbon. elucidating the desorption characteristics of phenol in the case of using acetone. The Freundlich isotherm constant ($k_e$) is expressed as a function of temperature: $k_e(T)=0.1exp(797.297/T)$. The Freundlich isotherm constant(n) is a weak temperature function and is rarely affected by temperature below $50^{\circ}C$. whereas it is necessary to correct the n value with respect to temperature above $100^{\circ}C$ owing to significant deviation (~5%). Based on the assumption that the surface desorption reaction of phenol is rate limiting, the desorption model was developed. Desorption reaction constant($k_d$) was determined by means of fitting the theoretical results best to experimental ones. The Arrhenius relationships for $k_d$ was expressed by: $k_d(sec^{-1})=0.0479{\cdot}exp(-3037/T)$. The model was verified by comparing the experimental ones under different reaction conditions with the theoretical results determined by the previously estimated $k_d$. Since the difference between them is with 5%, it is expected that the desorption model of this research seems to be appropriate to explain the desorption of phenol from activated carbon by acetone. According to studies of the model. regeneration time and ratio was estimated as a function of temperature under present conditions as follows: (1) regeneration time : ${\tau}_{reg}(hr)=-0.08130T_c+8.4775$. (2) regeneration ratio : ${\eta}(%)=0.2210T_c+83.745$. The regeneration time at 15, 55, and $100^{\circ}C$. respectively. was 7, 4.2, and 0.35 hours, whereas the regeneration ratio was 87. 96. and 99%. respectively. Also. studies of the model would make it possible to determine the regeneration time and ratio under other specific conditions (temperature, applied acetone volume, amount of activated carbon, and initially adsorbed phenol amount).

  • PDF

Pyrolysis Characteristics of CCL(Copper Clad Laminate) Based Paper/Phenolic Resin Composites (종이/페놀수지가 주성분인 동박적층판(Copper Clad Laminate)의 열분해 특성)

  • Song, Jae-Hun;Kim, Seung-Do;Ahn, Hyun-Cheol;Kim, Gyung-Soo;Kim, Sang-Bum;Jung, Jae-Sung;Gong, Sung-Ho;Cho, Young-Gae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.9
    • /
    • pp.1013-1019
    • /
    • 2007
  • Electronic wastes have increased tremendously. However, any reliable treatment methodologies have rarely been established. Electronic wastes have posed serious disposal problem due to their physico-chemical stability. This paper investigated the application possibility of pyrolysis for the purpose of recycling the p-CCL(phenol based Copper Clad Laminate). Thermogravimetric analysis(TGA) was used to investigate the thermal decomposition pattern of p-CCL. We elucidated the characteristics of pyrolysis by-products at operating temperatures of 280, 350 and $600^{\circ}C$. GC/MS and FT-IR were used to characterize the liquid by-products along with general characterization methods such as Ultimate Analysis, Proximate Analysis and Heating Value, whereas general characterization methods were only introduced for the solid by-products. At a heating rate of $5^{\circ}C$/min, TGA curves exhibited three decomposition stages: (1) low-temperature decomposition region$(<280^{\circ}C)$, (2) medium temperature region$(280\sim350^{\circ}C)$ and (3) high-temperature region$(>350^{\circ}C)$. The major compounds of liquid by-products at low- and medium-temperatures were accounted for by water and phenol, whereas branched phenols and furans were major compounds at high-temperatures. As the temperature increases, volatile quantities decreased but the fixed carbon increased. High heating values of solid by-products($7,400\sim7,600$ kcal/kg) would suggest that the solid by-products could be applicable as fuel. In addition, high fixed carbon but low ash content of the solid by-products offered an implication that they are capable of being upgradable for adsorbent after applying appropriate activating process.