• Title/Summary/Keyword: 흡입 유체

Search Result 212, Processing Time 0.022 seconds

Effect of a booster inducer on the suction performance of turbopumps (보조 인듀서가 터보펌프의 흡입성능에 미치는 영향)

  • Choi, Chang-Ho;Hong, Soon-Sam;Kim, Jinhan
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.552-557
    • /
    • 2004
  • Effects of a booster inducer on the suction performance of turbopumps are investigated in this paper. To see the effect of the booster inducer, suction performance tests are conducted with and without the booster inducer for three turbopumps. It is shown that the booster inducer can enhance the suction performance of turbopumps when the tip clearance of the main inducers are relatively large. Numerical analysis are also carried out to see the effects of the booster inducer on the performance of the main inducer. The booster inducer is shown to increase the static pressure at the inlet of the main inducer and prevent growing of inlet back flows which are believed to have deleterious effects on the suction performance of the inducer.

  • PDF

Development of the Sludge Treatment System in Water Bath of Painting Booth (도장부스 수조 내 슬러지 처리 시스템의 개발)

  • Lee, Chan;Cha, Sang Won;Yoo, Young Don
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.259-266
    • /
    • 2004
  • Developed is a sludge treatment system for introducing the waste water mixture with paint sludge from the water bath of paint booth and for recycling cleaned water to paint booth after sludge separation. Floated sludge is introduced from the water surface in the bath by using floating skimmer, and is conveyed by pump to the centrifugal separator where sludge and cleaned water are separated. From the operation results of the present sludge treatment systems applied in actual paint booths, paint sludge can be separated automatically and effectively from water bath with its water content of $60-70\%$, and sludge-free clean water is returned to paint booth.

  • PDF

Characteristics of Performance for Centrifugal Blower with Different Outlet Geometries (토출구의 형상에 따른 원심 송풍기의 성능특성)

  • Kim, Jae-Won;Kim, Jin-Min;Lee, Kook-Do
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.70-77
    • /
    • 2004
  • Comprehensive investigation on the outlet's geometric shapes of a centrifugal blower with higher inlet resistance than an atmospheric pressure is carried out for improvements of its performance. Most unwanted behaviors of such blower are pulsating flows because of unbalance between inflows and outflows in a scroll casing. In order to reduce this undesirable phenomenon a triump is made for both the shape of outlet duct and an accessory structure inserted in the outlet port of the blower. The modification on the shape is concerned with the contraction of cross sectional area and the attached structure is for an intentional obstruction to cause a flow resistance. The details of the modification are examined for different cases and results. The methodologies for the work are performance evaluations including noise level and velocity measurements with PIV Consequently, the performance of improved system is close to that of the system operating with atmospheric pressure at the inlet.

  • PDF

이젝터가 부착된 냉동시스템의 성능실험

  • 이원희;김윤조;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.993-1001
    • /
    • 2001
  • Experimental investigation on the performance of dual-evaporator refrigeration system with an ejector has been carried out. In this study, a hydrofluorocarbon (HFC) refrigerant R134a is chosen as a working fluid. The condenser and two-evaporators are made as concentric double pipes with counter-flow type heat exchangers. Experiments were performed by changing the inlet and outlet temperatures of secondary fluids entering condenser, high-pressure evaporator and low-pressure evaporator at test conditions keeping a constant compressor speed. When the external conditions (inlet temperatures of secondary fluid entering condenser and one evaporator) are fixed, results show that coefficient of performance (COP) increases as the inlet temperature of the other evaporator rises. It is also shown that the COP decreases as the mass flaw rate ratio of suction fluid to motive fluid increases. The COP of dual-evaporator refrigeration system with an ejector is superior to that of a single-evaporator vapor compression system by 3 to 6%.

  • PDF

Relationship between Cavitation Incipient and NPSH Characteristic for Inverter Drive Centrifugal Pumps

  • Rakibuzzaman, Md;Suh, Sang-Ho;Kim, Hyoung-Ho;Jung, Young-Hoon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.6
    • /
    • pp.76-80
    • /
    • 2015
  • The purpose of this study is to understand the cavitation phenomena in centrifugal pumps through computational fluid dynamics method. NPSH characteristic curve is measured from different flow operating conditions. Steady state, liquid-vapor homogeneous method with two equations transport turbulence model is employed to estimate the NPSH curve in centrifugal pumps. The Rayleigh-Plesset cavitation model is adapted as source term for inter-phase mass transfer in order to understand cavitation phenomena in centrifugal pumps. The cavitation incipient curve is clearly estimated at different flows operating conditions. A relationship is made between cavitation incipient and NPSH curve. Also the effects on water vapor volume fraction and pressure load distributions on the impeller blade are also described.

Study of Subsonic Diffusing S-Duct Design Optimization (아음속 확산형 S-덕트 최적 설계에 관한 연구)

  • Kim Su-whan;Kwon Jang-Hyuk
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.121-126
    • /
    • 2002
  • Aircraft propulsion systems often use diffusing S-duct to convey air flow from the wing or fuselage intake to the engine compressor, Well designed S-duct should incur minimal total pressure losses and deliver nearly uniform flow with small transverse velocity components at the engine compressor entrance. Reduced total pressure recovery lowers propulsion efficiency and nonuniform flow conditions at the engine face lower engine stall limits. In this study, S-duct which has maximum total pressure recovery and nearly uniform flow profiles at the compressure intake should be found using design optimization methods with 3-dimensional Wavier-Stokes analyses.

  • PDF

Experimental Study on Effect of the Contoured Endwall on the Three-Dimensional Flow in a Turbine Nozzle Guide Vane Cascade (끝벽의 형상이 터빈 노즐안내깃 캐스케이드내 3차원 유동에 미치는 영향에 관한 연구)

  • Yun, Won-Nam;Chung, Jin-Taek
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.514-519
    • /
    • 2003
  • The objective of this study is to document the secondary flow and the total pressure loss distribution in the contoured endwall installed linear turbine nozzle guide vane cascade passage and to propose an appropriate contraction ratio of the contoured endwall which shows the best loss reduction among the simulated cases. In this study, three different contraction ratio of contoured endwalls have been tested. This study was performed by experimental method and when the contoured endwall has the contraction ratio of 0.17 on exit height the results showed the best loss reduction.

  • PDF

Investigation of the Performance of Anti-Icing System of a Rotorcraft Engine Air Intake (회전익기 공기흡입구 주위 방빙장치 성능 해석)

  • Ahn, Gook-Bin;Jung, Ki-Young;Jung, Sung-Ki;Shin, Hun-Bum;Myong, Rho-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.4
    • /
    • pp.253-260
    • /
    • 2013
  • Ice accretions on the surface around a rotorcraft air intake can deteriorate the safety of rotorcraft due to the engine performance degradation. The computational simulation based on modern CFD methods can be considered extremely valuable in analyzing icing effects before exact but very expensive icing wind tunnel or in-flight tests are conducted. In this study the range and amount of ice on the surface of anti-icing equipment are investigated for heat-on and heat-off modes. It is demonstrated through the computational prediction and the icing wind tunnel test that the maximum mass and height of ice of heat-on mode are reduced about 80% in comparison with those of heat-off mode.

The Study of the Separation Efficiency of Wind Power Selector Using Computational Fluid Dynamics (전산유체역학을 이용한 풍력 선별기의 선별효율 연구)

  • Lee, Keon Joo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.21 no.3
    • /
    • pp.74-81
    • /
    • 2013
  • In this study, the separation efficiency of wind power selector (the direction of the air flow of the air to perform gravity separation method) of municipal solid waste which was landfilled was investigated to reduce amount of waste that is designed to increase the recycling rate of wastes for the ANSYS CFX Program's numerical methods with wind through the separator. When a suction device designed to suction 1000mL of a plastic bag, the separation efficiency was 100% and when the wind speed was 0.9 m /sec or more and when the wind speed was 1.6 m / sec or more, the efficiency of plastic bottles in a mixture of 500mL and 1500mL plastic bottle waste was 100% and the aluminum screening efficiency of 250mL aluminum can was 100 % when the wind speed was 2.3 m / sec. In the last, 5mm thick compressed aluminum can efficiency was 90 % when the wind speed was 2.4 m / sec.

A Study of Design Method of an Axial-Type Suction Fan (축류형 흡입송풍기 설계기술에 관한 연구)

  • Choi, Hyoung-Jun;Kim, Chang-Su;Cho, Chong-Hyun;Cho, Soo-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.1
    • /
    • pp.42-51
    • /
    • 2010
  • Many different types of fan have been applying to various industrial fields. Fan design methods are much different depending on the types of fan, operating conditions, and connecting parts at the inlet or exit of the fan etc. In this study, design methods for an axial-type suction fan are studied. This fan discharges the air in the relative static pressure of -285Pa to the atmosphere with the flow rate of $960m^3/min$. For three-dimensional blade design, three different design methods were applied, such as the free vortex method, the exponential method, and the cascade method. In the cascade method, the blade loading along the radial direction was obtained from the lift coefficient which was necessary to obtain the pressure rise on a fan rotor. This method is different from the free vortex and the exponential method which control the strength of the vortex. The fan performance prediction was conducted using the CFD with three different inlet ducts. The best fan performance was obtained when the fan was designed by using the cascade method. The designed fan using the exponential method showed better performance compared to a fan designed using the free vortex method. However, the fan performance was changed depending on the installed inlet ducts. So, an efficient fan can be designed with the adjustment of design variables on the basis of the flow structures within the fan as well as the fan design procedure.