Journal of the Korean Society of Marine Environment & Safety
/
v.25
no.7
/
pp.953-960
/
2019
The Miller cycle is a diesel engine that has been developed in recent years that it can reduce NOx and improve fuel consumption by reducing the compression ratio through intake valve closing (IVC) time control. The Miller cycle can be divided into the early Miller method of closing the intake valve before the bottom dead center (BDC) and the late Miller method of closing the intake valve after the BDC. At low speeds, the late Miller method is advantageous as it can increase the volumetric efficiency; while at medium and high speeds, the early Miller method is advantageous because of the high internal temperature reduction effect due to the expansion of the intake air during the piston lowering from IVC to BDC. Therefore, in consideration of the ef ects of the early and late Miller methods, it is necessary to adopt the most suitable Miller method for the operating conditions. In this study, a two-stage turbo charge system was applied to four-stroke engines and the process of enhancing the Miller effect through a reduction of the intake and exhaust valve overlap as well as the valve change adjustment mechanism were considered. As a result, the ef ects of fuel consumption and Tmax reduction were confirmed by adopting the Miller cycle with a two-stage supercharge, a reduction of valve overlap, and an increase of suction valve lift.
Proceedings of the Korean Society of Propulsion Engineers Conference
/
2008.11a
/
pp.94-97
/
2008
As the partial admission turbine has a intrinsically unsteady and three dimensional flow region, numerical calculation time of these study has been too long time. The numerical analysis for gas temperature of turbine blade surface has been performed to investigate development of temperature with various pyro start pressure. Computations have been carried out several turbine rotational speeds in the range from 0 to 16000 rpm and inlet conditions with 1423K, 7.2MPa. As a result, the more rotational speed and pyro starter pressure of turbine increased, the more turbine blade's temperature decreased. It is also found that flow field of turbine blade inlet area at pyro starter pressure of 5.75MPa and rotational speed of 12100 rpm formed surface temperature uniformly.
This study was conducted to investigate the effect of light intensity and temperature on the photosynthesis and respiration of ginseng plant. Highly significant, second degree curvilinear regressions were recognized among the photosynthesis of ginseng leaves, light intensity and temperature. And an interaction between the effects of light intensity and temperature on the photosynthesis of ginseng leaves was found to be highly significant. The increasing rate of photosynthesis with the increase of light intensity was markedly decreased with increasing temperature. The light compensation point of ginseng leaves was significantly varied with temperature, and the average point was approximately 600 lux. The light saturation point of Korean ginseng was 11,000 lux at $15^{\circ}C$ and $20^{\circ}C$ and around 9,500 lux at above $25^{\circ}C$. The decreasing rate of photosynthesis with the increase of temperature significantly increased with increasing light intensity. The optimum temperature for the photosynthesis of ginseng leaves was about 15 to $22^{\circ}C$ and markedly decreased with increasing light intensity. The highest photosynthesis occurred in ginseng leaves grown with the shade of 15% transmittance. The respiration of ginseng leaves increased with the shade of 5% and/or 30% transmittance. High temperature stimulated the respiration of ginseng leaves. Percent respiration to photosynthesis of ginseng leaves grown with the shade was increased at high temperature and decreased with increasing light Intensity. It was also increased with increasing transmittance. The maximum $CO_2$ absorption of ginseng leaves grown with the shade of 5Ps and ISVS transmittance accurred at 9 o'clock a.m., whereas that of 20% transmittance occurred at 7-9 o'clock a.m. The duration of $CO_2$ absorption was distinctively long with the shade of high transmittance. The $CO_2$ compensation point in the photosynthesis of ginseng leaves was 130 ppm.
Proceedings of the Korean Vacuum Society Conference
/
2012.08a
/
pp.101-101
/
2012
본 논문은 현재 제품화 단계로 진행 중인 터보 분자펌프(turbo-molecular pump, TMP)와 극저온 펌프(cryopump)의 고장 방지 및 예지 보수를 위한 상태 진단 시스템에 대하여 소개를 한다. 본 상태 진단 시스템은 고진공 펌프들의 다중 상태변수 즉 흡/배기부의 진공 압력, 부위별 온도, 소비 전류(혹은 전력), 그리고 부위별 진동 신호들을 실시간으로 측정하는 상태변수 수집장치, 수집된 시계열 상태변수들이 저장된 database, 그리고 저장된 상태변수를 이용한 고진공펌프의 상태진단 프로그램으로 구성되어 있다. 금번 연구에서 구축한 상태변수 체계의 특징 중 하나는 진동신호를 상태변수로 측정하여 이를 상태진단에 활용하는 점이 기존의 접근방법과 상이한 점이다. 실시간 신호 수집장치는 NI사 PXI 시스템 기반의 16채널 24-bit 동시 전압신호 측정 모듈, 8부위의 온도 측정장치(Lakeshore 218S, RS-232C 통신), 그리고 펌프의 소비전류/전력 측정장치(Hioki 3169, RS-232C), 그리고 고진공 펌프의 흡입 및 배기구의 진공도 측정장치로 구성하였다. 신호 수집용 프로그램은 NI사 Labview를 이용하여 작성하였다. 본 장치는 Nano-Fab 센터의 협조 하에 turbo-molecular 펌프와 cryopump측정 단에 각각 1대를 설치 완료하였으며 현재까지 운용 중이다. PC에 저장된 시계열 상태변수 database는 기 개발된 적응형 인자모델을 이용한 매개변수로 변환되며, 상태진단은 변환된 매개변수를 이용하여 수행할 예정이다.
Proceedings of the Korean Society for Bio-Environment Control Conference
/
1999.04a
/
pp.9-14
/
1999
1. LPG 온풍기는 용량 16$\times$$10^4$ ㎉ 건타입가스버너, 연소부 및 열교환부, 6개의 50kgLPG탱크와 자동절체기, 가스메타, 배관으로 구성하였다. LPG 온풍기의 이론연소효율은 91%, $CO_2$ 배출량은 11.74%, CO배출량은 0ppm, 과잉공기비는 1.16, 배기가스온도는 253$^{\circ}C$, 온풍온도는 8$0^{\circ}C$로서 우수한 성능으로 나타났다. 2. LPG온풍기에서 배출되는 배기가스중의 $CO_2$ 를 온실로 공급하기 위하여 $CO_2$ 공급기를 제작하여 배출가스연도에 부착하였다. $CO_2$ 공급기는 흡입형 시로코팬(1200㎥/h)과 차단문으로 이루어졌다. 1-2W형 300평 온실내의 $CO_2$ 농도를 1000ppm으로 올리기 위해서는 $CO_2$ 공급기를 약 1시간 정도 운전시켜야 할 것으로 판단되었다. 3. LPG온풍기와 경유온풍기의 경제성 비교분석에 의하면 현 시점의 경유 가격 242원, LP가스 가격 435원을 기준으로 연간소요비용은 각각 5,392,430원, 5,299,917원으로 경유온풍기가 10만원 정도 경제적이지만 탄산가스 시용비용, 탄산가스 공급으로 인한 작물의 수량증대 및 고품질 생산물을 고려한다면 LPG온풍기 사용이 더 경제적이라 사료된다.
This study investigated the interface temperatures for the sliding friction of three types of pins fabricated with thermocouple wires by the suction casting method. Optical microscopy was used to examine the surrounding material state at the bonding interface with the thermocouple wires. Friction tests were performed under dry sliding conditions against stainless steel 304 at nominal stresses of 1.42-4.25 MPa and sliding speeds of 0.5-1.25 m/s. Tribological data were collected using a custom-made pin-on-disk apparatus that measured the interface temperature and corresponding friction coefficient. Static tests were performed to demonstrate the functionality and reliability of the thermocouple wires-combined temperature sensor (TCTS). Each TCTS showed good linearity and sensitivity and very similar response times for the thermocouple and critical temperature during sliding friction.
In this study, the energy conversion equipment from the radiation energy to mechanical energy by using npentane as the operating fluid was constructed and the performance to pump the water was tested for the utilization of solar powered water pump. The equipment was designed optimally, after the theoretical analyses of the water pumping head and water quantity per cycle were done. The pentane vapour temperature in the condenser and the temperature of the outlet water from the condenser became lowered and the heat transfer rate became higher with decreasing the water inlet level to the condenser. The temperature difference between the condenser and the water tank was significant. Therefore, the distance between the water tank and condenser was recommended to be shorten and the diameter of their connecting pipe was recommended to be narrow in order to reduce the resistance of the fluid passage and improve the heat transfer rate. The amount of water pumped was 1.62.4 liters. Mass flow rate of the cooling water became lowered when the cooling water pipe was prolonged from the condenser to improve the heat transfer rate.
In this study, computational simulation was performed for thermal management of modules consisting of 10 batteries. Simplified structure and equivalent thermal resistance network was applied to maintain the thermal properties. Verification test of the mesh were in progress to ensure the reliability of 2.6 mm in the narrow gap between the battery, resulting in at least three divided mesh between the shape of the grid was required. Type of air from rear of the module, type of air from top of the module and type of air from bottom of the module were applied and effective cooling methods are discussed based on the location of fan and air intake of the modules. Maximum temperature and temperature differences of modules that directly affect the performance of the module were compared, and also behavior of the fluid was confirmed by comparing the air flow. The best maximum temperature is shown type of air from bottom of the module to $40.27^{\circ}C$ and type of air from top of the module shows smallest temperature difference $0.73^{\circ}C$.
Journal of Advanced Marine Engineering and Technology
/
v.35
no.5
/
pp.566-575
/
2011
Since LPG (Liquefied petroleum gas) fuel supply system has an advantage of low emission characteristics, many studies have been conducted. In spite of the advantage of LPG supply system, a higher vapor pressure and lower viscosity than diesel or gasoline fuel may cause unstable running of fuel pump by the deterioration in lubrication performance and chemical reaction with rubber parts than that of diesel and gasoline fuel. Therefore its physical properties can cause the deterioration of durability. In this research, we developed an external type LPG pump which has the advantage of the price competitiveness and the convenient maintenance for LPLi system. The experiments were carried out in order to assess characteristics of the external type fuel pump at different fuel composition and temperature. As a result, there aren't any differences between internal and external type pump performance. It is observed that the same level of efficiency was maintained for both pumps as flow rate was increased with higher fuel temperature and more contents of propane in the fuel. And the pressure difference in LPLi system is maintained at constant with the various fuel compositions and temperatures due to their own characteristics of fuel supply system.
Journal of the Korean Society for Aeronautical & Space Sciences
/
v.39
no.10
/
pp.966-978
/
2011
Transpiration cooling is the most effective cooling technique for the high-performance liquid rockets and air-breathing engines operating in aggressive environments with higher pressures and temperatures. When applying transpiration cooling, combustor liners and turbine blades/vanes are cooled by the coolant(air or fuel) passing through their porous walls and also the exit coolant acting as an insulating film. Practical implementation of the cooling technique has been hampered by the limitations of available porous materials. But advances in metal-joining techniques have led to the development of multi-laminate porous structures such as Lamilloy$^{(R)}$ fabricated from several diffusion-bonded, etched metal thin sheets. And also with the availability of lightweight, ceramic matrix composites(CMC), transpiration cooling now seems to be a promising technique for high-performance engine cooling. This paper reviews recent research activities of transpiration cooling and its applications to gas turbines, liquid rockets, and the engines for hypersonic vehicles.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.