• Title/Summary/Keyword: 흡수판

Search Result 194, Processing Time 0.021 seconds

A CLINICAL STUDY OF BIODEGRADABLE PLATES AND SCREWS IN ORAL AND MAXILLOFACIAL SURGERY (구강 악안면 영역의 생체 흡수성 고정판 사용에 관한 임상 연구)

  • Kim, Il-Kyu;Park, Seung-Hoon;Jang, Keum-Soo;Yang, Jung-Eun;Jang, Jae-Won;Sasikala, Balaraman
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.6
    • /
    • pp.451-458
    • /
    • 2009
  • Metallic bone plates and screws have been commonly used in oral and maxillofacial surgery for internal fixation. However, there are several disadvantages such as atrophy of cortical bone inherent to excessive rigid fixation systems, growth disturbance in growing individual, allergy reaction, interference with radiographic imaging, palpability, thermal sensitibity and the need for subsequent removal. To overcome these disadvantages and avoid additional surgery of removal of plates and screws, there have been many studies of biodegradable plates and screws. But, It also has complication such as foreign body reactions. We have undertaken a clinical and retrospective study on 140 patients in Dept. of Oral and Maxillofacial Surgery, Inha University Hospital from February 2006 to March 2009. The purpose of this study is to report the clinical cases and review of the literatures with biodegradable plates and screws. And we concluded following results. 1. 6 cases(3.4%) of the 177 operation sites(140 patients) experienced complications. 1 case(0.6%) was a failure of initial fixation, 1 case(0.6%) was a postoperative infection, 4 cases(2.3%) were inflammations or foreign body reaction. 2. Postoperative infections, inflammations and foreign body reactions were completely recovered with incision and drainage, supporative care with antibiotic coverage and removal of biodegradable plates. 3. Biodegradable plates and screws provide acceptable rigidity and stability clinically. But, long-term observation is required for the tissue reactions around the biodegradable plates and screws because of long resorption periods of the biodegradable materials.

On the Calibration of Impact Hammer Sensitivity (충격 해머의 감도보정)

  • 한상보
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.71-74
    • /
    • 1991
  • 구조물의 진동특성을 파악하기 위한 실험적 모우드 해석법에서 기진력을 제 공하는 한 방법으로 힘 측정기가 부착된 해머를 이용한 충격시험기법이 널 리 사용되고 있다. 충격해머 시험의 유용성은 기진력의 에너지가 정현파 기 진력의 경우처럼 특정 주파수대에 산재해 있는 것이 아니라 가용 주파수 영 역내에 연속적으로 분포해 있다는 점이며 이러한 충격력은 가용 주파수 범 위내에 있는 모든 고유진동형을 여가시킬 수 있다는 장점이 있다. 충격헤머 가 가지고 있는 동적특성은 구조물을 가진시키는 선형충격량의 크기를 결정 하며, 이는 다시 충격력의 크기와 가용 주파수 범위를 결정하게 된다. 일반 적으로 가진주파수 범위는 해머의 질량에 반비례하고 충격해드의 경도에 비 례하는 것으로 알려져 있다. 해머의 질량 자체가 충격력의 크기를 좌우하기 도 하므로, 가진력의 크기를 고려하여 해머의 질량이 선택되며 충격헤드는 충격시간을 조절하기 위하여 적절히 선택된다. 충격해머에 장착된 힘측정기 의 감도는 해머질량과 충격헤드의 질량 변화에 영향을 받게 되는데, 충격 시 험시 측정되는 값은 해머에 부착되어 있는 힘측정기에 가해지는 힘인 반면 구조물에 가해지는 기진력은 충격해드와 구조물사이에 발생되는 힘이다. 이 두 힘의 비는 해머 및 충격해드의 질량효과에 따라 좌우된다. 주어진 충격시 험에서 충격해머의 질량효과를 정확히 조건에 따라 감도보정을 해 주어야 한다. 충격해머의 감도보정에 대해서는 문헌[2]에 잘 나타나 있다. 본 논문에 서는 전압감도에 미치는 영향을 파악하고자 질량 효과를 고려한 수학적 모 형을 제시하고 그 모형의 타당성을 실험을 통해 검정하고자 한다.방법 을 제시하였다. 이와 아울러 제어계의 환경변화에 따른 파라메타의 변화에 적응적으로 응답이 가능해야 하는 적응 소음제어 시스템에서, 음향궤환과 함 께 필히 고려해야 하는 부가적인 전달함수의 영향을 고려한 능동 소음제어 에 대해 연구하였다. 경량화 추세에 따라 지반이나 케이싱이 경량이거나 유연하여 회전축과 동적으로 연성된 경우 회전축-베어링-지반으로 이루어진 2중구조의 회전축 계 동특성을 해석할 수 있는 프로그램을 개발하므로서 회전 기계류의 진동 전반에 걸친 문제점에 대한 그 원인과 현상을 명확히 분석하여 국내의 전기 계류의 보다 신뢰성있는 설계 및 제작자료를 확보하는데 기여할 수 있게 하 였다.존의 small molecular Gd-chelate에 비해 매우 큼을 알 수 있었다. MnPC는 간세포에 흡수된 후 담도계로 배출되는 간특이성 조영제임을 확인하였다. 장비 내에서 반복 시행한 평균값의 차이는 대체적으로 유의한 차이가 없었으나, 다른 장비에서 반복 시행한 장비간의 사이에는 유의한 차이가 있는 경우가 더 많았다. 따라서 , MRS 검사를 소뇌나 뇌교의 어떤 절환에 적용하기 전에 각 장비 마다 정상 기준치를 반드시 얻은 후에 이상여부를 판 정하는 것이 필수적이라고 생각된다.EX> 이상이 적절한 진단기준으로 생각되었다. $0.4{\;}\textrm{cm}^3$ 이상의 좌우 부피차를 보이는 모든 증례에서 육안적으로도 해마위축이 뚜렷이 나타났다. 결론 : MR영상을 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다

  • PDF

Active Noise Control in Ductilike System using Adaptive Filtering (적응필터링에 의한 덕트계의 능동소음제어)

  • 이태연;김상명;송원식;오재응
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.17-22
    • /
    • 1991
  • 최근 기계장치로부터 발생하는 소음을 감소시키는 새로운 방법으로서, 능동 적으로 소음을 제어하는 방법에 대한 연구가 활발히 진행되고 있다. 이것은 원하지 않는 소음을 그 신호의 역위상을 갖는 부가음을 이용하여 능동적으 로 감쇠시키는 방법으로서, 저주파수 대역에서 비효율적인 수동적인 방법인 소음기둥에 대한 대안으로 많은 학자들의 관심의 대상이 되어 왔다. 초기에 는 소음을 줄이기 위해 요구되는 여러가지 음향요소의 전달함수를 제어하는 데 대한 불가능성으로 인해 능동 소음제어에 대한 실질적인 발전이 지연되 어 왔으나 최근 마이크로 컴퓨터를 비롯한 전자공학의 발전으로 인해 적응 신호처리 분야가 등장하게 되었으며, 음향계의 소음을 원하는 수준까지 제어 하는 능동 소음제어의 실시간 구현이 가능하게 되었다. 그 중에서도 음이 1 차원적으로 전파한다고 볼 수 있는 길이가 긴 덕트구조물에서의 능동 소음 제어는 가장 기본적이며 현실적으로 자동차 배기계나 냉동.공조설비에 있어 서 실용적으로 적용할 수 있는 문제임 만큼 많은 연구가 이루어지고 있다. 이러한 능동 소음제어 방법을 음향계에 적용하였을 때, 부가적인 음을 발생 하는 제어용 스피커로 인해 입력마이크로폰으로의 음향궤환이 존재하고 이 에 따라 제어계가 불안정해질 수 있으며, 또한 변환기의 사용으로 인한 부가 적인 전달함수가 존재하므로 이에 대한 중요한 의미를 갖고 고려하여야 한 다. 본 연구에서는 적응 필터링 이론에 의한 소음원의 입력신호에 대한 최적 한 예측으로써 부가음을 발생시키고, 입력신호 및 제어된 출력신호간의 차인 오차를 최소화 시키도록 하는 오차적응제어법을 이용한 능동소음 제어 방법 을 제시하였다. 이와 아울러 제어계의 환경변화에 따른 파라메타의 변화에 적응적으로 응답이 가능해야 하는 적응 소음제어 시스템에서, 음향궤환과 함 께 필히 고려해야 하는 부가적인 전달함수의 영향을 고려한 능동 소음제어 에 대해 연구하였다. 경량화 추세에 따라 지반이나 케이싱이 경량이거나 유연하여 회전축과 동적으로 연성된 경우 회전축-베어링-지반으로 이루어진 2중구조의 회전축 계 동특성을 해석할 수 있는 프로그램을 개발하므로서 회전 기계류의 진동 전반에 걸친 문제점에 대한 그 원인과 현상을 명확히 분석하여 국내의 전기 계류의 보다 신뢰성있는 설계 및 제작자료를 확보하는데 기여할 수 있게 하 였다.존의 small molecular Gd-chelate에 비해 매우 큼을 알 수 있었다. MnPC는 간세포에 흡수된 후 담도계로 배출되는 간특이성 조영제임을 확인하였다. 장비 내에서 반복 시행한 평균값의 차이는 대체적으로 유의한 차이가 없었으나, 다른 장비에서 반복 시행한 장비간의 사이에는 유의한 차이가 있는 경우가 더 많았다. 따라서 , MRS 검사를 소뇌나 뇌교의 어떤 절환에 적용하기 전에 각 장비 마다 정상 기준치를 반드시 얻은 후에 이상여부를 판 정하는 것이 필수적이라고 생각된다.EX> 이상이 적절한 진단기준으로 생각되었다. $0.4{\;}\textrm{cm}^3$ 이상의 좌우 부피차를 보이는 모든 증례에서 육안적으로도 해마위축이 뚜렷이 나타났다. 결론 : MR영상을 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both inflection fie이 and the maximum relaxivity value. The results shows a fluences on both inflection field

  • PDF

The Design of Reconstruction Filter for the Order Tracking of the Rotating Machinery (회전기기 진동의 Order Tracking을 위한 재합성 필터의 설계)

  • 정승호;박영필;이상조
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.95-98
    • /
    • 1991
  • 회전 기기의 이상으로 인하여 발생하는 진동은 축 회전속도의 고주파 성분 (super-harmonic)이나 또는 분수조파 성분(sub-harmonic)으로 나타나는 경 우가 대부분이기 때문에 회전기기의 진동을 주파수 영역에서 해석함에 있어 파워 스펙트럼의 주파수 축을 Hz로 나타내기보다는 축 회전속도의 order로 써 나타내는 것이 매우 유용하다. 스펙트럼을 order로써 나타내기 위해서는 샘플링 시간을 축 회전속도와 동기(synchronization)시켜야 하는데 이 방법으 로는 회전축에 엔코더(encorder)를 부착하여 엔코더에서 발생하는 펄스 신호 를 이용하여 샘플링하는 방법과 order tracking 필터를 이용하는 방법이 있 다. 그러나 전자의 방법은 원하는 회전축마다 엔코더를 부착하여야 하며 경 우에 따라서는 엔코더를 부착하기가 어려운 경우도 있으며, 회전기기의 운전 개시나 종료시처럼 회전속도가 급격히 변화하는 경우에는 낮은 주파수에서 중첩(aliasig)에 의한 오차가 수반될 수도 있다. 후자의 방법은 order tracking 필터 이외에도 여러 부수장비가 필요하며 기준 주파수(즉 회전속 도)가 급격히 변화하는 경우 PLL(phase locked loop)에서 tracking 오차가 발생된다. 최근에 발표된 논문에서 일정한 시간간격으로 샘플링한 데이터들 로부터 신호를 재합성하여 회전축의 속도와 동기가 되도록 재 샘플링함으로 서 스펙트럼의 주파수를 회전속도의 order로써 나타내는 방법을 제시하였다. 그러나 위 논문에서는 신호의 재합성에 필요한 재합성 필터(reconstruction filter)의 설계 방법에 대하여 구체적인 언급이 없이 다만 결과만을 논하였다. 따라서 본 논문에서는 재합성 필터의 설계 방법에 대하여 구체적인 방법을 제시하고 또한 동기화 샘플링의 장점 및 고려 사항에 대하여 고찰하였다. 고려한 능동 소음제어 에 대해 연구하였다. 경량화 추세에 따라 지반이나 케이싱이 경량이거나 유연하여 회전축과 동적으로 연성된 경우 회전축-베어링-지반으로 이루어진 2중구조의 회전축 계 동특성을 해석할 수 있는 프로그램을 개발하므로서 회전 기계류의 진동 전반에 걸친 문제점에 대한 그 원인과 현상을 명확히 분석하여 국내의 전기 계류의 보다 신뢰성있는 설계 및 제작자료를 확보하는데 기여할 수 있게 하 였다.존의 small molecular Gd-chelate에 비해 매우 큼을 알 수 있었다. MnPC는 간세포에 흡수된 후 담도계로 배출되는 간특이성 조영제임을 확인하였다. 장비 내에서 반복 시행한 평균값의 차이는 대체적으로 유의한 차이가 없었으나, 다른 장비에서 반복 시행한 장비간의 사이에는 유의한 차이가 있는 경우가 더 많았다. 따라서 , MRS 검사를 소뇌나 뇌교의 어떤 절환에 적용하기 전에 각 장비 마다 정상 기준치를 반드시 얻은 후에 이상여부를 판 정하는 것이 필수적이라고 생각된다.EX> 이상이 적절한 진단기준으로 생각되었다. $0.4{\;}\textrm{cm}^3$ 이상의 좌우 부피차를 보이는 모든 증례에서 육안적으로도 해마위축이 뚜렷이 나타났다. 결론 : MR영상을 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both inflection fie이 and the maximum relaxivity value. The re

  • PDF

System Development of Cubsat SIGMA(KHUSAT-3)

  • Shin, Jehyuck;Lee, Seongwhan;Lee, Jung-Kyu;Lee, Hyojeong;Lee, Jeongho;Seo, Junwon;Shin, Youra;Jeong, Seonyeong;Cheon, Junghoon;Kim, Hanjun;Lim, Jeonghyun;Lee, Junmin;Jin, Ho;Nam, Uk-Won;Kim, Sunghwan;Lee, Regina;Kim, Hyomin;Lessard, Marc R.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.106-106
    • /
    • 2014
  • SIGMA (Scientific cubesat with Instrument for Global Magnetic field and rAdiation)는 근 지구공간에서 우주방사선량 측정과 자기장 변화 검출의 과학적 목적과 교육적 목적을 가지고 개발하고 있는 초소형 큐브위성이다. $100mm{\times}100mm{\times}340.5mm$의 크기로 약 3.6 kg의 무게를 가지며, 탑재체는 방사선에 대하여 인체와 동일한 산란 흡수 특성을 가진 Tissue Equivalent Proportional Counter (TEPC)와 자기장 측정을 위한 Magnetometer (Mag)이다. 위성체는 구조계, 자세제어계, 전력계, 명령 및 데이터처리계, 통신계로 구성되어있다. 구조계는 위성의 뼈대인 Chassis와 Mag deployer로 이루어져있고, 위성의 안정적인 자세유지를 목적으로 Attitude Control System (ACS) Board와 Torque Coil이 자세제어계로 구성된다. 전력의 생산과 공급 및 충전은 태양전지판과 Electrical Power System (EPS), 리튬 배터리로 구성된 전력계에서 이뤄지며, 명령 및 데이터처리계는 On Board Computer (OBC)와 Instrument Interface board (IIB)를 중심으로 서브시스템의 명령체계와 데이터처리를 다룬다. 통신계는 Uplink인 VHF 안테나와 Downlink인 UHF, S-band 안테나로 구성되며 지상과 명령을 송수신한다. SIGMA는 타임인터럽트 기능을 활용한 Flight Software (FSW)로 운용되며 임무에 따른 6가지 모드의 시나리오로 위성을 운용한다. 이에 SIGMA의 개발과 테스트 결과를 소개한다. 본 큐브위성 개발기술을 바탕으로 향후 천문관측용 위성에도 활용할 예정이다.

  • PDF

Radioopacity of Absorbable Plate containing Hydroxyapatite and Gold(Au); A Preliminary Report (Hydroxyapatite와 금(Au)이 혼합된 흡수성 고정판의 방사선비투과성; 예비 실험)

  • Kim, Yong Ha;Nam, Hyun Jae;Lee, Joon Ho;Kim, Kap Joong;Kim, Yeon Jung;Choi, Sik Young
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.419-422
    • /
    • 2008
  • Purpose: Absorbable bone fixation materials for operation of facial bone fracture are composed of poly- lactic acid(PLA) & poly-glycolic acid(PGA). These materials are absorbed after facial bone healing period. Therefore, these materials are harmless in human body. But because of it's radioopacity, the number and the location of the materials are not checked in follow-up X-ray examination. We studied absorbable bone fixation materials checked radiological examination. So, we made the absorbable plate composed of PLA, Hydroxyapatite (HA) and Gold(Au). Methods: Plate 1 was consisted of pure PLA. Plate 2 was consisted of PLA(50%) and HA(50%). Plate 3 - 7 were consisted of PLA(50%), and variable composition of HA & Au. The ratio of Au was as following. From the plate 3 to plate 7, the Au ratio was 1%, 5%, 10%, 17%, and 25%, respectively. Total 3 examinations were used-naked eye examination, simple X-ray examination, and Haunsfield unit of plate in CT examination. Results: Naked eye examination found out that the color of plate 1 was most white. As the Au ratio increases, the color of plate was getting close to khaki color. the radioopacity of plate 2 was similar cortical bone of face in simple X-ray. The Haunsfield unit of cortical bone of face was 1000 HU. Haunsfield unit of titanium plate was 2900 HU. Haunsfield unit of plate 1 through plate 7 were -242, 1489, 1776, 3052, 3092, 3095, and 3095, respectively. Conclusion: Radioopacity of plate 2 was similar to cortical bone of face. In CT examination, Hanusfield unit of plate 2 was similar to Hanusfield unit of cortical bone of face. Hanusfield unit of plate 4 - 7 were similar to Hanusfield unit of titanium plate. So to trace bone fixation materials after facial bone surgery, the best ratio of Au is about 1 - 5%. If this study is applied to facial bone surgery, radiologic follow up would be easy after facial bone surgery.

Lumbar Herniated Disc Resorption of 78 Patients after Korean Medicine Treatment (요추 추간판 탈출증 환자 78명의 한방치료 후 디스크 재흡수 증례 보고)

  • Jung, Bum-Hwan;Jo, Joo-Hyun;Yoon, Yong-Il;Park, Sang-won;Kim, Sung-Moon;Go, Ung;Jung, Jin-soo;Kim, Jung-Hoon;Huh, Suk-Won;Kim, Ji-Won;Kim, Moon-Hwi
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.26 no.1
    • /
    • pp.87-93
    • /
    • 2016
  • Objectives To analyze the resorption of herniated lumbar intervertebral disc on MRI in patients who were treated with Korean Medicine. Methods 78 patients with lumbar disc herniation were included, 47 males and 32 females. Patients' diagnosis was based on magnetic resonance imaging (MRI). All of the patients were only treated with Korean Medicine for 6 months treatment, and underwent MRI examination twice, pre-treatment and post-treatment. MR images were assessed by reduction in diameter of T2-weighted image between pre-treatment and post-treatment, and analyzed by differences in sex, age and disc type. Results 91.2% (71 people) of total patients had extrusion type. Korean medicine treatment reduced lumbar disc herniation diameter of all the patients from 7.11 mm to 3.67 mm on average (p<0.001). The reduction of diameter in the male group was 3.52 mm on average. The reduction of diameter in the female group was 3.32 mm on average. The reduction of diameter was 3.28 mm in the group below age 29, 3.88 mm in the 30~39 age group, 3.39 mm in the 40~49 age group, and 2.71 mm in the above 50 age group on average. Conclusions The MRI results suggest that lumbar herniated disc can resorb with Korean Medicine treatment. The likelihood of lumbar disc resorption was higher at extrusion type. but there was not a significant difference between the sexes and between ages.

Effect of Clamping Pressure on Surface Properties of Gas Diffusion Layer in PEFCs (체결압이 고분자연료전지 기체확산층의 표면성질에 미치는 영향)

  • Ahn, Eun-Jin;Park, Gu-Gon;Yoon, Young-Gi;Park, Jin-Soo;Lee, Won-Yong;Kim, Chang-Soo
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.4
    • /
    • pp.306-310
    • /
    • 2007
  • Characteristics of GDL (Gas Diffusion Layer) mainly determine the gas diffusion and water removal in a cell, thereby changing the performance and affecting durability of PEFC. To optimize the water management and understand the two phase flow in a GDL, it is important to study the behaviors of GDL micro structure under the real operating condition. In the clamped condition of cell, the GDL beneath the rib is more compressed than beneath the channel. Many researches on physical, electrochemical, mechanical behaviors of gas diffusion layer has been conducted. However, changes in surface properties under clamped condition have rarely studied. In present study, the morphology of broken connections of carbon fibers and detachment of PTFE coatings on the fibers were shown from the microscopic observations. In addition, changes in wetting properties of GDL by compression were investigated by using XPS and liquid uptake methods. The hydrophobic characteristics of GDL surface beneath the rib of the flow field plate are changed due to the deformation of micro structure.

Evaluation of the Radiopacity of Contemporary Luting Cements by Digital Radiography (디지털방사선촬영술을 이용한 합착용 시멘트의 방사선불투과성 평가)

  • An, Seo-Young;Lee, Du-Hyeong;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.377-383
    • /
    • 2013
  • This study examined the radiopacity of eight contemporary luting cements by direct digital radiography. Five disc-shaped specimens ($5mm{\times}1mm$) were prepared for each material tested (BisCem, Clearfil SA Luting, Duolink, Maxcem Elite, Multilink Speed, Panavia F 2.0, RelyX Unicem Clicker, V-link). The specimens were radiographed using a Kodak CS 7600 image plate (Carestream Health, Inc., Rochester, NY, USA) and an aluminum step wedge with a range of thicknesses (1.5 to 16.5 mm in 1.5 mm increments) and a 1 mm tooth used as a reference. A dental X-ray machine Kodak 2200 Intraoral X-ray System (Carestream Health, Inc., Rochester, NY, USA), operating at 70 kVp, 4 mA, 0.156 s and a source-to-sample distance of 30 cm, was used. According to international standards, the radiopacity of the specimens was compared with that of an aluminum step wedge using NIH ImageJ software (available at http://rsb.info.nih.gov/ij/).The data was analyzed by ANOVA and a Tukey's post hoc test. Maxcem Elite (5.66) showed the highest radiopacity of all materials, followed in order by Multilink Speed (3.87) and V-link (2.83). The radiopacity of Clearfil SA Luting (1.35), BisCem (1.33), Panavia F 2.0 (1.29) and Duolink (1.10) were between enamel (1.79) and dentin (0.19). RelyX Unicem Clicker (0.71) showed the lowest radiopacity, which was higher than that of dentin. All materials showed a radiopacity above the minimum recommended by the International Organization for Standardization and the American National Standards/American Dental Association with the exception of RelyX Unicem Clicker.

Organic Precipitate Flotation of Trace Metallic Elements with Ammonium Pyrrolidinedithiocarbamate(Ⅰ). Determination of Bismuth, Cadmium, Cobalt and Lead in Water Samples by Coprecipitation-Flotation with Cu-pyrrolidinedithiocarbamate (Ammonium Pyrrolidinedithiocarbamate에 의한 극미량 금속원소의 유기침전 부선에 관한 연구(제1보) Cu-pyrrolidinedithiocarbamate 공침부선에 의한 물시료중 비스무트, 카드뮴, 코발트 및 납의 정량)

  • Jung, Yong June;Choi, Jong Moon;Choi, Hee Seon;Kim, Young Sang
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.12
    • /
    • pp.724-732
    • /
    • 1996
  • The organic precipitate flotation using Cu(II)-pyrrolidinedithiocarbamate complex as a coprecipitant was studied for the preconcentration and determination of trace Cd, Pb, Bi and Co in several water samples. Experimental conditions such as pH of solution, amounts of Cu(II) and ammonium pyrrolidinedithiocarbamate(APDC), stirring time, the type and amount of surfactant, etc. were optimized for the effective flotation of analytes. After 3.0 mL of 1,000 ${\mu}g/mL$ Cu(II) solution was added to 1.00 L water sample, the pH of the solution was adjusted to 2.5 with HNO3 solution. Trace amounts of analytes were coprecipitated by adding 2.0% APDC solution. And the precipitates were flotated onto the surface of solution with the aid of nitrogen gas and sodium lauryl sulfate. The floats were collected from mother liquor, and filtered through the micropore glass filter by suction. The precipitates were dissolved with 4 mL conc. HNO3, and then diluted to 25.00 mL with deionized water. The analytes were determined by graphite furnace atomic absorption spectrophotometry. This flotation technique was applied to the analysis of some water samples, and the 90 to 120% of recoveries were obtained from the spiked samples, this procedure could be concluded to be simple and applicable for the trace element analysis in various kinds of water.

  • PDF