Measuring Absorbed Dose from Medical X-ray Equipment Using Optically Stimulated Luminescence Dots (광자극선량계의 저에너지 엑스선 특성비교)

  • Jung, Sook Jin;Jin, Gye Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.79-83
    • /
    • 2018
  • In this paper, we measured and analyzed the dose correction factor, absorbed dose linearity, peak voltage X-ray response, angular dependence. Exposure dose correction factor, absorbed dose linearity, and peak voltage linearity using the medical X-ray generator were all in accordance with IEC-62387-1 (2007). The reference to the dosimetry direction at 0, 30, and 60 degrees relative to baseline radiation exposure was -29% (${\pm}30^{\circ}$) and + 67% (${\pm}60^{\circ}$). The values measured at $30^{\circ}$ were -8% lower than the standard and -18% lower than the standard at $60^{\circ}$. Therefore, the effect of direction should be corrected when using OSL dot dosimeter.

An Analysis of A Circularly Polarized Conformal Microstrip Parch Antenna Using The Unsplit Anisotropic Perfectly Matched Layer(UAPML) (비분리형 비등방성 완전 정합층(UAPML)을 이용한 원형편파 등각 마이크로스트립 패치 안테나의 해석)

  • 박동희;김정기
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.6
    • /
    • pp.813-823
    • /
    • 1998
  • This paper analyzed the circularly polarized conformal microstrip patch antennal using the unsplit anisotropic perfectly matched layer(UAPML) method. Also, this paper are treated effectively the edge and corner parts on the 3 dimensional UAPML. Especially, to analyze microstrip patch antennas with the coaxial feeder line, it was applied to mixed the UAPML with Mur's first order absorbing boundary condition. Therefore this paper suggest the new the method to mix the UAPML with Mur's first order absorbing boundary condition. The results show the time responses of electromagnetics $E_z$ and $H\chi'$, input impedances of coaxial cable and radiation patterns of strip parchs on the single and the array patchs with central frequencies 1.575 GHz, 1.778 GHz and 4.8 GHz in L-band and C-band for mobile communication. The results of this paper shows that its results was compared the Mur's first order abc and mixed the second order dispersion boundary condition(SDBC) with the Mur's first order absorbing boundary condition. In accordance with, the validity of the method is confirmed.

  • PDF

The Crystallograpic and Magnetic Properties of EuFeO3 Doped with in ions (In 이온을 첨가한 $EuFeO_{3}$의 결정구조 및 자기적 성질)

  • 김정기;서정철;한은주
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.4
    • /
    • pp.335-339
    • /
    • 1994
  • The crystallograpic and magnetic properties of $Eu(Fe_{1-x}In_{x})O_{3}$ (x=0, 0.03과 0.05) have been studied by the methods of X-ray diffraction, $M\"{o}ssbauer$ spectroscopy, and magnetic hysteresis measurement at room temperature. The X-ray results show that the samples have a crystal structure of orthorhombic and unit cell volume of the crystal with the exception of the sample of x=0 increases as increasing the In concentration. In the analysis assuming two sets of six-line of $M\"{o}ssbauer$ spectra, it is found that the magnetic hyperfine field in each of sets decreases increasing x. The linewidth of the absorption lines for the samples increased as increasing x. This implies that the data involve a sum of several hyperfine patterns which have intensity being proportional to $_{n}P_{z}(x)$, the probability of an environment with z such Fe neighbors. The magnetic hysteresis curves show decrease of $M_{s}$ and increase of $H_{c}$ of the samples with increasing x.

  • PDF

Beta Dosimetry for Applying $^{166}Ho$-chitosan Complex to Cystic Brain Tumor Treatment : Monte Carlo Simulations Using a Spherical Model ($^{166}Ho$-chitosan 복합체를 이용한 낭성뇌종양 치료를 위한 베타선의 흡수선량 평가 : 구형 모델을 이용한 Monte Cairo 모사계산)

  • Kim, Eun-Hee;Rhee, Chang-Hun;Lim, Sang-Moo;Park, Kyung-Bae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.4
    • /
    • pp.433-439
    • /
    • 1997
  • $^{166}Ho$-chitosan complex, or $^{166}Ho$-CHICO, is a candidate pharmaceutical for intracavitary radiation therapy of cystic brain tumors because of the desirable nuclear characteristics of $^{166}Ho$ for therapeutic use and the suitable biological and chemical characteristics of chitosan, not to mention its ready producibility The amount of $^{166}Ho$-CHICO to be administered to obtain the goal therapeutic effect can be suggested by predicting the dose to the cyst wall for a varying pharmaceutical dose. When $^{166}Ho$-CHICO is infused into the cyst, the major part of the energy delivery by beta particles emitted from $^{166}Ho$ occurs in the cyst wall within 4mm in depth from the cyst wall surface. Also, realizing the attachment of $^{166}Ho$-CHICO to the cyst wall surface would change the predictions of dose to the cyst wall.

  • PDF

The Effects of Metal Plate loaded on TLD chip in 6 MV Photon and 6 MeV Electron Beams (6 MV 광자선과 6 MeV 전자선 하에서 TLD 기판 위에 얹힌 금속 박막의 효과)

  • Kim, Sookil;Byungnim Min
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.41-46
    • /
    • 1999
  • There is necessity for making a smaller and more sensitive detector in small field sizes. This report assesses the suitability of metal-loaded thermoluminescent dosimeters for this purpose. Measurements were performed in the 6 MV photon and 6 MeV electron beams of a medical linear accelerator with LiF thermoluminescence dosimeters (TLD-100) embedded in solid water phantom. TLD-100 chips(surface area 3.2 $\times$ 3.2 $\textrm{mm}^2$) loaded with a metal plate(Tin or gold respectively) were used to enhance dose readings to TLD-100. Surface dose was measured for field size 10 $\times$ 10 $\textrm{cm}^2$ and 100 em SSD. Measurements have been made of the enhanced signal intensity and good linearity for absorbed dose with each metal. Using a 1 mm each metal on TLD-l00 in the beam increased the surface dose to 14% and 56% respectively for 6MV photon. In the case of 6 MeV electron, gold plate enhanced the TL response to 13%, but there is no difference for tin plate. The specific dose response of TLD-100 with thin metal plate increases with electron concentration of metal film, this is most likely due to increased electron scattered from the additional material with electron density higher than TLD-100. This emphasizes the role of TL dosimeters with metal as amplified dosimeters for therapeutic high energy x-ray beams. Due to the enhanced dose reading of TLD-100 with metal plate, it could be possible to develop smaller TL dosimeter with high sensitivity.

  • PDF

High Energy Photon Dosimetry by ESR Spectroscopy in Radiotherapy (ESR Spectroscopy에 의한 치료용 고에너지 광자선의 선량측정)

  • Chu, Sung-Sil
    • Progress in Medical Physics
    • /
    • v.1 no.1
    • /
    • pp.31-42
    • /
    • 1990
  • The finding of long lived free radicals produced by ionizing radiation in organic crystals and the quantification of this effect by electron spin resonance(ESR) spactroscopy has proven excellent dosimetric applicability. The tissue equivalent alanine dosimeter also appear appropriate for radiation therapy level dosimetry. The dose measurement was performed in a Rando phantom using high energy photons as produced by high energy medical linear accelerator and cobalt-60 teletherapy unit. The absorbed dose range of the ESR/alanine dosimetry system could be extended down to 0.1 Gy. The response of the alanine dosimeters was determined for photons at different therapeutic dose levels from less than 0.1 Gy to 100 Gy and the depth dose measurements were carried out for photon energies of 1.25MeV, 6 and 10 MV with alanine dosimeters in Rando phantom. Comparisons between ESR/alanine in a Rando phantom and ion chamber in a water phantom were made performing depth dose measurements to examine the agreement of both methods under field conditions.

  • PDF

Absorption Spectra of Standard Gases for Wavelength Reference in C-band using a Supercontinuum Source Based on a Mode-locked Cr4+:YAG Laser (모드 잠금 Cr4+:YAG 레이저로부터 발생된 초 광대역 광원을 이용한 광통신 파장 영역의 표준 가스의 흡수스펙트럼)

  • Lee, Jong-Min;Jeon, Min-Yong;Ryu, Han-Young;Suh, Ho-Suhng
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.1
    • /
    • pp.54-59
    • /
    • 2008
  • We report on the measurements of absorption spectra from acetylene ($^{12}C_2H_2$) and hydrogen cyanide ($H^{13}C^{14}N$) for wavelength reference in the C-band (conventional band) region using a supercontinuum optical source generated from a mode-locked $Cr^{4+}$:YAG laser. The center wavelength of the mode-locked $Cr^{4+}$:YAG laser was 1510 nm and the pulse duration was 75 fs at 100 MHz repetition rate. The supercontinuum source achieved a flatness of ${\pm}5dB$ over a wavelength range of more than 400 nm, using a 20 m long photonic crystal fiber. The measured absorption spectra from acetylene ($^{12}C_2H_2$) and hydrogen cyanide ($H^{13}C^{14}N$) had more than 50 lines and were analyzed for wavelength standardization.

Spectroscopic Characteristics of Ruby from Gorno-Badakhshan, Tajikistan (타지키스탄 고르노바다흐샨주 지역 루비에 대한 분광학적 특성 연구)

  • Chung, Sol Lim;Park, Jong Wan
    • The Journal of the Petrological Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • Physical properties, XRF, UV-Vis, FTIR studies were carried out in order to characterize gemological features of ruby from Tajikistan. Fluorescence reaction of the Tajikistan ruby to short wave ultraviolet was moderate to very strong in red and long wave ultraviolet rays was weakly detected. UV-visible analysis strong absorption bands at 468.5, 475, 476.5 nm and broaden bands at 550 nm were observed for ruby due to $Cr^{3+}$. According to FT-IR analysis, all rubies from Tajikistan showed the similar patterns and kaolinite peaks at 3500, 3617, 3630, $3677cm^{-1}$ and boehmite broaden absorption bands at 3085 and $3320cm^{-1}$. Inclusions in Tajikistan ruby are observed solid inclusions, negative crystals, needle and silk inclusions. These distinctive characteristics mentioned above can be used to identify the locality and source of ruby stones from Tajikistan.

X-ray Absorptiometry Image Enhancement using Sparse Representation (Sparse 표현을 이용한 X 선 흡수 영상 개선)

  • Kim, Hyung-Il;Eom, Won-Yong;Ro, Yong-Man
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2012.05a
    • /
    • pp.30-33
    • /
    • 2012
  • 대사성 골 질환인 골다공증(Osteoporosis)의 조기 진단을 위해 X 선 영상에서 골 밀도를 측정하는 방법이 최근 연구되고 있다. 골 밀도는 X 선 영상에서 뼈가 분리되고, 분리된 영역에서의 픽셀에 의해 BMD가 측정되는데, 개선된 영상에서의 정밀한 뼈 추출이 주요한 요소이므로 X 선 영상의 개선은 골다공증의 조기 진단을 위해 필수적이다. 본 논문에서는 sparse 표현법을 도입하여 X 선 영상을 개선시키는 방법을 제안한다. 실험을 통해 제안한 방법의 결과가 기존의 방법인 웨이블릿 BayesShrink에 비해 개선됨을 CNR(Contrast to Noise Ratio)을 통해 확인하였다.

  • PDF

Microbiological, physicochemical, and organoleptic evaluation of fresh-cut vegetables irradiated using X-rays (엑스선 조사처리된 신선편의 채소류의 미생물학적, 이화학적, 관능적 품질 평가)

  • Moon, Byeong-Geum;Song, Beom-Seok;Park, Jong-Heum;Kim, Jae-Kyung;Park, Ha-Young;Kim, Dong-Ho;Son, Eun-Joo;Im, Don-Sun;Eun, Jong-Bang
    • Food Science and Preservation
    • /
    • v.24 no.1
    • /
    • pp.27-35
    • /
    • 2017
  • Microbiological, physicochemical, and organoleptic properties of fresh-cut vegetables (FVs), carrots, green peppers, cherry tomatoes, and paprika after X-ray irradiation were evaluated to verify food quality suitable for the immune-depressed patients. Total concentrations of aerobic bacteria in non-irradiated samples, except for cherry tomatoes, were 1.63-3.34 log CFU/g. Irradiation dose exceed 0.4 kGy was used for carrots and green peppers whereas the sterilization dose of 0.2 kGy was used for both cherry tomatoes and paprika. A dose of 0.4 kGy was tentatively determined as the minimum allowable dose for sterilization of the FVs, based on $D_{10}$-values of X-ray irradiation (0.11-0.32 kGy) for Escherichia coli, Listeria monocytogenes, and Salmonella Typhimurium inoculated on the samples. With respect to the physiological properties, only hardness was significantly decreased as the absorbed dose increased; however, there were no significant differences in hardness of the sterilized samples using X-rays at 0.4 kGy compared with those of non-irradiated samples (p<0.05). Moreover, overall acceptance scores of the sterilized FVs were higher than 5.0 points on a 7-point scale, indicating a good organoleptic quality. In a survey on preference of hospitalized patients with cancer (n=50), the average scores for the sterilized FVs, except for carrots, were higher than 4.0 points. In conclusion, it is considered that the FVs, except for carrots, sterilized using X-rays at 0.4 kGy could be served to immune-depressed patients as hygienically safe foods with acceptable organoleptic properties.