• Title/Summary/Keyword: 흡수선량 평가

Search Result 208, Processing Time 0.021 seconds

The Study on the Reduction of Patient Surface Dose Through the use of Copper Filter in a Digital Chest Radiography (디지털 흉부 촬영에서 구리필터사용에 따른 환자 표면선량 감소효과에 관한 연구)

  • Shin, Soo-In;Kim, Chong-Yeal;Kim, Sung-Chul
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.223-228
    • /
    • 2008
  • The most critical point in the medical use of radiation is to minimize the patient's entrance dose while maintaining the diagnostic function. Low-energy photons (long wave X-ray) among diagnostic X-rays are unnecessary because they are mostly absorbed and contribute the increase of patient's entrance dose. The most effective method to eliminate the low-energy photons is to use the filtering plate. The experiments were performed by observing the image quality. The skin entrance dose was 0.3 mmCu (copper) filter. A total of 80 images were prepared as two sets of 40 cuts. In the first set (of 40 cuts), 20 cuts were prepared for the non-filter set and another 20 cuts for the Cu filter of signal + noise image set. In the second set of 40 cuts, 20 cuts were prepared for the non-filter set and another 20 cuts for the Cu filter of non-signal image (noisy image) with random location of diameter 4 mm and 3 mm thickness of acryl disc for ROC signal at the chest phantom. P(S/s) and P(S/n) were calculated and the ROC curve was described in terms of sensitivity and specificity. Accuracy were evaluated after reading by five radiologists. The number of optically observable lesions was counted through ANSI chest phantom and contrast-detail phantom by recommendation of AAPM when non-filter or Cu filter was used, and the skin entrance dose was also measured for both conditions. As the result of the study, when the Cu filter was applied, favorable outcomes were observed on, the ROC Curve was located on the upper left area, sensitivity, accuracy and the number of CD phantom lesions were reasonable. Furthermore, if skin entrance dose was reduced, the use of additional filtration may be required to be considered in many other cases.

  • PDF

Development of Signal Processing Modules for Double-sided Silicon Strip Detector of Gamma Vertex Imaging for Proton Beam Dose Verification (양성자 빔 선량 분포 검증을 위한 감마 꼭지점 영상 장치의 양면 실리콘 스트립 검출기 신호처리 모듈 개발)

  • Lee, Han Rim;Park, Jong Hoon;Kim, Jae Hyeon;Jung, Won Gyun;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.2
    • /
    • pp.81-88
    • /
    • 2014
  • Recently, a new imaging method, gamma vertex imaging (GVI), was proposed for the verification of in-vivo proton dose distribution. In GVI, the vertices of prompt gammas generated by proton induced nuclear interaction were determined by tracking the Compton-recoiled electrons. The GVI system is composed of a beryllium electron converter for converting gamma to electron, two double-sided silicon strip detectors (DSSDs) for the electron tracking, and a scintillation detector for the energy determination of the electron. In the present study, the modules of a charge sensitive preamplifier (CSP) and a shaping amplifier for the analog signal processing of DSSD were developed and the performances were evaluated by comparing the energy resolutions with those of the commercial products. Based on the results, it was confirmed that the energy resolution of the developed CSP module was a little lower than that of the CR-113 (Cremat, Inc., MA), and the resolution of the shaping amplifier was similar to that of the CR-200 (Cremat, Inc., MA). The value of $V_{rms}$ representing the magnitude of noise of the developed system was estimated as 6.48 keV and it was confirmed that the trajectory of the electron can be measured by the developed system considering the minimum energy deposition ( > ~51 keV) of Compton-recoiled electron in 145-${\mu}m$-thick DSSD.

Quality Characteristics of Milk Porridge (Tarakjuk) Sterilized with Radiation Technology (방사선 조사 기술을 이용하여 제조한 멸균 우유죽(타락죽)의 품질 특성)

  • Han, In-Jun;Park, Jae-Nam;Park, Jin-Gyu;Song, Beom-Seok;Lee, Ju-Woon;Kim, Jae-Hun;Ryu, Hong-Soo;Park, Jeong-Ro;Chun, Soon-Sil
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.6
    • /
    • pp.885-891
    • /
    • 2011
  • We conducted this study to determine the optimum dose of gamma irradiation needed for the sterilization of milk porridge for patients. Milk porridge, known as Tarakjuk, was irradiated with gamma ray at doses of 0, 1, 3, 5, 7, or 10 kGy. The microbial contamination, $D_{10}$ values of isolated microbe spores, color, and viscosity were measured during storage at $35^{\circ}C$. The initial count of total aerobic bacteria was 2.60 log CFU/g in the non-irradiated milk porridge, but coliforms, spore-forming bacteria, yeast, and molds were not detected. The total counts of aerobic and spore-forming bacteria in the non-irradiated and 1 kGy irradiated milk porridge increased with storage period. These microbes were not detected in the milk porridge irradiated with 10 kGy. The $D_{10}$ values of isolated spores from milk porridge were 2.71 kGy (in milk porridge) and 2.21 kGy (in saline solution). All CIE color increased with gamma irradiation, but the sensory value of color did not significantly change. The viscosity of the milk porridge decreased with gamma irradiation and storage period, and the decrease in viscosity with storage period became smaller as the radiation doses increased. Sensory evaluation scores of the milk porridge were above normal (4.0) when irradiated with less than 5 kGy. These results indicate that gamma irradiation could be beneficial for preparing food with higher nutrient density and lower viscosity, especially for gastric tube-fed patients.

Quantitative Assessment of the Radiation Exposure during Pathologic Process in the Sentinel Iymph Node Biopsy using Radioactive Colloid (방사성 콜로이드를 이용한 감시림프절 생검 병리처리과정에서 방사선 피폭의 정량적 평가)

  • Song, Yoo-Sung;Lee, Jeong-Won;Lee, Ho-Young;Kim, Seok-Ki;Kang, Keon-Wook;Kook, Myeong-Cherl;Park, Weon-Seo;Lee, Geon-Kook;Hong, Eun-Kyung;Lee, Eun-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.309-316
    • /
    • 2007
  • Purpose: Sentinel lymph node biopsy became the standard procedure in early breast cancer surgery. Faculty members might be exposed to a trace amount of radiation. The aim of this study is to quantify the radiation exposure and verify the safety of the procedure and the facilities, especially during pathologic process. Materials and Methods: Sentinel lymph node biopsies with Tc-99m human serum albumin were performed as routine clinical work. Exposed radiation doses were measured in pathologic technologist, nuclear medicine technologist, and nuclear medicine physician using a thermoluminescence dosimeter (TLD) during one month. We also measured the residual radioactivities or absorbed dose rates, the exposure distance and time during procedure, the radiation dose of the waste and the ambient equivalent dose of the pathology laboratory. Results: Actual exposed doses were 0.21 and 0.85 (uSv/study) for the whole body and hand of pathology technologist after 47 sentinel node pathologic preparations were performed. Whole body exposed doses of nuclear medicine physician and technologist were 0.2 and 2.3 (uSv/study). According to this data and the exposure threshold of the general population (1 mSv), at least 1100 studies were allowed in pathology technologist. The calculated exposed dose rates (${\mu}$ Sv/study) from residual radioactivities data were 2.47/ 22.4 ${\mu}$ Sv (whole body/hand) for the surgeon; 0.22/ 0 ${\mu}$ Sv for operation nurse. The ambient equivalent dose of the pathology laboratory was 0.02-0.03 mR/hr. The radiation dose of the waste was less than 100 Bq/g and nearly was not detected. Conclusion: Pathologic procedure relating sentinel lymph node biopsy using radioactive colloid is safe in terms of the radiation safety.(Nucl Med Mol Imaging 2007;41(4);309-316)

Study on Shielding using CT Contrast Medium (CT 조영제를 이용한 차폐체에 대한 연구)

  • Gang, Heon-Hyo;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.693-698
    • /
    • 2018
  • Currently, shields for shielding medical radiation during medical examinations in the medical environment are lead robe and lead glass. Lead, the main component of this shielding, has limitations in lead poisoning and light weight, and high price. Iodine, which is used as contrast medium instead of lead shield, is expected to be effective as a shield because it has radiation absorbing properties. The purpose of this study was to evaluate the effectiveness of shielding by using acrylic plate filled with CT contrast agent for clinical use instead of conventional lead glass. As a result, it was found that the acrylic plate filled with the CT contrast agent showed a shielding effect of 7 times or more when the scattering ray dose was not shielded. Therefore, CT contrast agent composed of iodine is expected to be used as a shield instead of conventional lead glass.

Influence of the Monitoring Interval and Intake Pattern for the Evaluation of Intake (내부피폭 감시주기 및 섭취형태가 방사성핵종 섭취량 평가에 미치는 영향)

  • Jong-Il Lee;Tae-Young Lee;Si-Young Chang;Jai-Ki Lee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.1
    • /
    • pp.53-59
    • /
    • 2004
  • A variety of factors such as the pattern of intake (acute or chronic), monitoring interval and the characteristics of the radionuclides could have a significant influence on the estimates for the intake and internal dose. The relative differences of the assessed intakes based on the assumption of an acute intake to that of a chronic intake were evaluated by using the predicted bioassay quantity in the whole body or organs for an acute and chronic intake through the inhalation of $^{125}$ I, $^{137}$ C, $^{235}$ U with the AMAD of 1 ${\mu}{\textrm}{m}$ and 5 ${\mu}{\textrm}{m}$ for the monitoring intervals of 7, 14, 30, 60, 90, 120, 180, 360 days, respectively, The relative difference of the assessed intakes based on the intake pattern is affected by the monitoring interval, radionuclide and absorption type, but the particle size has little influence on the difference of the assessed intakes based on the intake pattern. The maximum monitoring interval, which is defined as the monitoring interval that the relative difference of the assessed intakes based on the assumption of an acute intake to that of a chronic intake is less than 10%, is 60 d for $^{125}$ I with Type F, 180 d for $^{137}$ C with Type F, 90 d for $^{235}$ U with Type M, and 360 d for $^{235}$ U with Type S. It was concluded that an intake pattern has little influence on the estimates of the assessed intake in the case where the monitoring interval is shorter than the maximum monitoring interval for each radionuclide.

  • PDF

Comparison of the Quality of Gamma Ray- or Electron Beam-irradiated Minced Pork and Pork Patties (감마선 또는 전자선 조사된 분쇄돈육과 돈육패티의 저장 중 품질특성 비교)

  • Song, Beom-Seok;Park, Jin-Gyu;Kim, Wang-Geun;Kim, Jae-Hun;Choi, Jong-Il;Yoon, Yo-Han;Byun, Myung-Woo;Kim, Cheon-Jei;Lee, Ju-Woon
    • Food Science of Animal Resources
    • /
    • v.29 no.2
    • /
    • pp.194-202
    • /
    • 2009
  • This study was conducted to determine the effects of gamma and e-beam irradiation on the quality of minced pork and pork patties. Each sample was irradiated at 5 to 20kGy, and its quality characteristics were then evaluated during storage at 30. The results of the total bacterial populations in the minced-pork and pork patty samples showed that the antimicrobial effect of gamma irradiation was superior to that of e-beam irradiation. The 2-thiobarbituric acid reactive substances (TBARS) value of all the samples significantly increased (p<0.05) as the irradiation dose and storage period increased. In addition, the gamma-irradiated (GI) samples had higher (p<0.05) TBARS values than the e-beam-irradiated (EI) samples. The volatile basic nitrogen contents of the GI samples were lower (p<0.05) than those of the EI samples. The color values, such as the $L^*$(brightness), $a^*$(redness), and $b^*$(yellowness) of the minced pork and pork patties, were increased (p<0.05) by irradiation. The hardness and sensory properties, such as the color, chewiness, taste, and overall acceptability of the pork patties, were decreased when the irradiation dose increased, and the hardness and sensory scores of the GI samples were lower than those of the EI samples.

Measurement of Electron Beam Output for the Prototype Compact Linac (콤팩트 전자 선형가속기 시작품의 출력측정에 관한 연구)

  • Kim, Sung-Woo;Kang, Sang Koo;Rhee, Dong Joo;Lim, Heuijin;Lee, Manwoo;Yi, Jungyu;Lee, Mujin;Yang, Kwangmo;Ro, Tae Ik;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.1-5
    • /
    • 2015
  • The C-band compact linear accelerator (linac) is being developed at Dongnam Institute of radiological & Medical Sciences (DIRAMS) for medical and industrial applications. This paper was focused on the output measurement of the electron beam generated from the prototype electron linac. The dose rate was measured in unit of cGy/min per unit pulse frequency according to the IAEA TRS-398 protocol. Exradin-A10 Markus type plane parallel chamber used for the measurement was calibrated in terms of dose to water at the reference depth in water. The beam quality index ($R_{50}$) was determined by the radiochromic film with a solid water phantom approximately due to low energy electrons. As a result, the determined electron beam output was $17.0cGy/(min{\cdot}Hz$. The results were used to monitor the accelerator performance during the development procedure.

Soil-to-Plant Transfer Coefficients of Mn-54, Co-6O, Zn-65 and Cs-137 for Rice, Soybean and Vegetalbles (벼, 콩 및 채소류에 대한 Mn-54, Co-60, Zn-65, Cs-137의 토양-작물체간 전이계수)

  • Choi, Yong-Ho;Kim, Kug-Chan;Lee, Chang-Woo;Lee, Kang-Suk;Lee, Jeong-Ho;Pak, Chan-Kirl;Cho, Yong-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.2
    • /
    • pp.55-65
    • /
    • 1991
  • Soil-to-plant transfer coefficients of Mn-54, Co-60, Zn-65, and Cs-137 were estimated for the edible parts of the rice, soybean, lettuce, carrot, and squash grown in different soils by radiotracer uptake experiments using pot cultures. The transfer coefficients of radionuclides were in the order of Zn-65 > Mn-54 > Cs-137 > Co-60 in most of the cases studied. The coefficients for soybean were roughly an order of magnitude higher than those for rice. Among vegetables, lettuce mostly showed the highest value and squash, the lowest. In the strongly acidic soils, transfer coefficients were much higher than in the moderately acidic soils. From the data obtained. crop-specific transfer coefficients of the four nuclides were proposed for the use in Korean food-chain radiation dose assessment.

  • PDF

Evaluation of Countermeasures Effectiveness in a Radioactively Contaminated Urban Area Using METRO-K : The Implementation of Scenarios Designed by the EMRAS II Urban Areas Working Group (METRO-K를 사용한 방사능으로 오염된 도시지역에서 대응행위효과 평가 : EMRAS II 도시오염평가분과 시나리오의 이행)

  • Hwang, Won-Tae;Jeong, Hae-Sun;Jeong, Hyo-Joon;Kim, Eun-Han;Han, Moon-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.3
    • /
    • pp.108-115
    • /
    • 2012
  • The Urban Areas Working Group within the EMRAS-2 ($\underline{E}$nvironmental $\underline{M}$odelling for $\underline{RA}$diation $\underline{S}$afety, Phase 2), which has been supported by the IAEA (International Atomic Energy Agency), has designed some types of accidental scenarios to test and improve the capabilities of models used for evaluation of radioactive contamination in urban areas. For the comparison of the results predicted from the different models, the absorbed doses in air were analyzed as a function of time following the accident with consideration of countermeasures to be taken. Two kinds of considerations were performed to find the dependency of the predicted results. One is the 'accidental season', i.e. summer and winter, in which an event of radioactive contamination takes place in a specified urban area. Likewise, the 'rainfall intensity' on the day of an event was also considered with the option of 1) no rain, 2) light rain, and 3) heavy rain. The results predicted using a domestic model of METRO-K have been submitted to the Urban Areas Working Group for the intercomparison with those of other models. In this study, as a part of these results using METRO-K, the countermeasures effectiveness in terms of dose reduction was analyzed and presented for the ground floor of a 24-story business building in a specified urban area. As a result, it was found that the countermeasures effectiveness is distinctly dependent on the rainfall intensity on the day of an event, and season when an event takes place. It is related to the different deposition amount of the radionuclides to the surfaces and different behavior on the surfaces following a deposition, and different effectiveness from countermeasures. In conclusion, a selection of appropriate countermeasures with consideration of various environmental conditions may be important to minimize and optimize the socio-economic costs as well as radiation-induced health detriments.