Electromagnetic Wave in all Base Stations (다기지국 환경에서 전자파 노출량)

  • Cho, Euy-Hyun;Park, Jeong-Kyu
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.9
    • /
    • pp.26-44
    • /
    • 2011
  • The Study was carreid out to see whether the intensity of electromagnetic waves in each floor of a building where the sharing base station has been established is harmful to a human body, and to expect the intensity of the waves in the building. The investigate was performed on both of sharing base station either with many scatterers or without any of them. To satisfy the international standard and the domestic TTA standard, rms for each of the electromagnetic wave of every floor in the building with the station was measured from 3 location of 3 heights(1.1m,1.5m, and 1.7m). Max of the measured rsm from the each of the frequencies in the nine location was confirmed to be 48.12%(the rooftop measured value) at most, compared to the human body protection standard. The value was confirmed to satisfy the human body protection standard for each frequency. And the total value of the calculated exposure indexes for each frequency was determined to be more than 7 times lower at most, which was 0.1445, compared to the 1 standard. Since P value in both of 868MHz and 2.14GHz electromagnetic waves intensity for each base station and floor was less than 0.05, it was revealed to be meaningful, and since R-Sq(adj) value showed a value more than 50%, the regression equation was determined to fully absorb the data information. However, although the P value of both of 868MHz and 2.14GHz electromagnetic waves intensities under the integrating terms of the base station data and the floor data was showed to be less than 0,05, since R-Sq(adj) value of 868MHz electromagnetic waves intensity presented a value smaller than 50%(34.15%), it was determined that the 868MHz electromagnetic waves intensity is very much influenced by an environment with a base station. Because the electromagnetic waves intensity of 2.14GHz show R-Sq(adj) value bigger then 50%(51.8%), The regression equation model of 2.14GHz electromagnetic waves intensity was confirmed to be proper. It also turned out not to be effected by the surrounding environment near a building with the base station and the intensity of electromagnetic waves for each floor of such building was expectable by the regression equation.

Ex vivo Morphometric Analysis of Coronary Stent using Micro-Computed Tomography (미세단층촬영기법을 이용한 관상동맥 스텐트의 동물 모델 분석)

  • Bae, In-Ho;Koh, Jeong-Tae;Lim, Kyung-Seob;Park, Dae-Sung;Kim, Jong-Min;Jeong, Myung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.93-98
    • /
    • 2012
  • Micro-computed tomography (microCT) is an important tool for preclinical vascular imaging, with micron-level resolution. This non-destructive means of imaging allows for rapid collection of 2D and 3D reconstructions to visualize specimens prior to destructive analysis such as pathological analysis. Objectives. The aim of this study was to suggest a method for ex vivo, postmortem examination of stented arterial segments with microCT. And ex vivo evaluation of stents such as bare metal or drug eluting stents on in-stent restenosis (ISR) in rabbit model was performed. The bare metal stent (BMS) and drug eluting stent (DES, paclitaxel) were implanted in the left or right iliac arteries alternatively in eight New Zealand white rabbits. After 4 weeks of post-implantation, the part of iliac arteries surrounding the stent were removed carefully and processed for microCT. Prior to microCT analysis, a contrast medium was loaded to lumen of stents. All samples were subjected to an X-ray source operating at 50 kV and 200 ${\mu}A$ by using a 3D isotropic resolution. The region of interest was traced and measured by CTAN analytical software. Objects being exposed to radiation had different Hounsfield unit each other with values of approximately 1.2 at stent area, 0.12 ~ 0.17 at a contrast medium and 0 ~ 0.06 at outer area of stent. Based on above, further analyses were performed. As a result, the difference of lengths and volumes between expanded stents, which may relate to injury score in pathological analysis, was not different significantly. Moreover, ISR area of BMS was 1.6 times higher than that of DES, indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. And ISR area of BMS was higher ($1.52{\pm}0.48mm^2$) than that of DES ($0.94{\pm}0.42mm^2$), indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. Though it was not statistically significant, it showed that the extent of neointema of mid-region of stents was relatively higher than that of anterior and posterior region in parts of BMS as showing cross-sectional 2-D image. suggest that microCT can be utilized as an accessorial tool for pathological analysis.

Study on the Physical Properties of the Gamma Beam-Irradiated Teflon-FEP and PET Film (Teflon-FEP 와 PET Film 의 감마선 조사에 따른 물리적 특성에 관한 연구)

  • 김성훈;김영진;이명자;전하정;이병용
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.11-21
    • /
    • 1998
  • Circular metal electrodes were vacuum-deposited with chromium on the both sides of Teflon-FEP and PET film characteristic of electret and the physical properties of the two polymers were observed during an irradiation by gamma-ray from $\^$60/Co. With the onset of irradiation of output 25.0 cGy/min the induced current increased rapidly for 2 sec, reached a maximum, and subsequently decreased. A steady-state induced current was reached about in 60 second. The dielectric constant and conductivity of Teflon-FEP were changed from 2.15 to 18.0 and from l${\times}$l0$\^$-17/ to 1.57${\times}$10$\^$-13/ $\Omega$-$\^$-1/cm$\^$-1/, respectively. For PET the dielectric constant was changed from 3 to 18.3 and the conductivity from 10$\^$-17/ to 1.65${\times}$10$\^$-13/ $\Omega$-$\^$-1/cm$\^$-1/. The increase of the radiation-induced steady state current I$\^$c/, permittivity $\varepsilon$ and conductivity $\sigma$ with output(4.0 cGy/min, 8.5 cGy/min, 15.6 cGy/min, 19.3 cGy/min) was observed. A series of independent measurements were also performed to evaluate reproducibility and revealed less than 1% deviation in a day and 3% deviation in a long term. Charge and current showed the dependence on the interval between measurements, the smaller the interval was, the bigger the difference between initial reading and next reading was. At least in 20 minutes of next reading reached an initial value. It may indicate that the polymers were exhibiting an electret state for a while. These results can be explained by the internal polarization associated with the production of electron-hole pairs by secondary electrons, the change of conductivity and the equilibrium due to recombination etc. Heating to the sample made the reading value increase in a short time, it may be interpreted that the internal polarization was released due to heating and it contributed the number of charge carriers to increase when the samples was again irradiated. The linearity and reproducibility of the samples with the applied voltage and absorbed dose and a large amount of charge measured per unit volume compared with the other chambers give the feasibility of a radiation detector and make it possible to reduce the volume of a detector.

  • PDF

Effect of Microwave Preheating and Hydrogenated Frying Fats on the Storage Stability of Yackwa (마이크로웨이브 열처리 및 경화튀김유가 약과의 저장 안정성에 미치는 영향)

  • 김창순;윤미화
    • Korean journal of food and cookery science
    • /
    • v.15 no.3
    • /
    • pp.264-271
    • /
    • 1999
  • This study was conducted to know the storage stability of Yackwa, a traditional Korean fried cookie, prepared by two different cooking methods; deep fat frying at 160$^{\circ}C$ for 8 min (DFF), and preheating Yackwa dough and then deep fat frying at 180$^{\circ}C$ for 2 min (MW/DFF). Soybean oil (SBO), hydrogenated soybean oil (HSBO) or hydrogenated palm oil (HPO) were used for frying Yackwa. Compared to Yackwa prepared by DFF, all MW/DFF Yackwa samples had low fat content and high moisture content. MW/DFF saved frying time 6 min compared with DFF. Non-hydrogenated soybean oil for frying fats was replaced with hydrogenated types of soybean oil and palm oil to improve the storage stability of Yackwa. To investigate the oxidation stability of Yackwa during the accelerated storage for 15 days at 60$^{\circ}C$, acid value, anisidine value, peroxide value and oxidation value of Yackwas were measured. Acid values of Yackwa made by MW/DFF were higher than those made by DFF through the whole storage periods, regardless of frying fats. Peroxide and anisidine values of Yackwa coated with syrup were much lower than those without syrup. MW/DFF cooking method, using hydrogenated soybean oil or hydrogenated palm oil for frying, showed lowering effects on peroxide value as well as anisidine value, resulting in improved oxidation stability of Yackwa during the storage. In sensory evaluation, the acceptability of MW/DFF Yackwa was higher than those of the commerical products. Yackwa prepared by MW/DFF cooking method using hydrogenated palm oil, showed the highest acceptability in color, taste and texture among the samples.

  • PDF

Effective Coastal Water Quality Management and Marine Environmental Impact Assessment (연안의 효율적 수질관리 방향과 해양환경영향평가)

  • Lee, Dae-In;Eom, Ki-Hyuk;Kim, Gui-Young;Hong, Sok-Jin;Lee, Won-Chan;Jang, Ju-Hyoung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.14 no.1
    • /
    • pp.29-37
    • /
    • 2008
  • This study examined principles and techniques of efficient water quality management as well as total coastal pollutant loads and the relevant examples in the advanced countries from the viewpoints of water quality improvement and pollution control in coastal areas. The problems and improvements in an estimation of the current total pollutant loads were also pointed out. In addition, discussion was made on the relationship between total pollutant loads and environmental capacity as well as particulars requiring extensive examination on access to and study on water quality model used as prediction tool for marine environment. Furthermore, this study proposed details of and improvement plans for water quality control to be reflected and absorbed into systems and policies related to coastal water quality. In coastal areas, which are subject to total coastal pollutant loads, it is necessary to calculate pollutant loads reduction and allocation, to propose them in detail in statement in relations to new pollution sources for the corresponding projects or plans in environmental impact assessment and prior environmental review system. Also, in relations to regional plans for coastal management, the local government concerned must focus more on environmental management plan to implement data on pollution sources and pollutant loads flown into sea areas under basic jurisdiction, therefore it is required to actively respond to expansion and introduction of total coastal pollutant loads system in the future. Total coastal pollutant loads system must be expanded and executed by considering characteristics of sea area and changes in the environment of land. For pollution sources in land, the competent authorities in charge of coastal environment will need to initiatively administer supervision, monitoring activities and achieve integration and operation of the related laws by preparing legal bases for management system or adjusting the related laws.

  • PDF

A Study of material analysis and its experimentation of metamorphosis and its utilities in Copper Alloy plates for contemporary metal craft (현대금속공예용 동합금판의 재료분석과 형질변환 실험 및 응용에 관한 연구)

  • Lim, Ock-Soo
    • Archives of design research
    • /
    • v.17 no.4
    • /
    • pp.241-250
    • /
    • 2004
  • In this research, the copper alloy plates C2200, C5210, C7701, C8113 were selected to make datum and to identify further usage of metal craft experimentation. For its experimentation, the general welding and TIG welding methods were researched; for 2nd experimentation, the Reticulation and Electroforming skill's differences in color and temperature were researched. With these methods 3 different kinds of works are introduced for sample studies. For this research, Dr. Lee, Dong-Woo who works in Poongsan Metal Co, supported 4 kinds of copper alloy metals. Which are Commercial bronze (Cu-Zn), Deoxidiged Copper(Cu-Sn-P), Nickel Silver (Cu-Ni-Zn), and White Bronze (Cu-Ni); they were applied partly and wholly by the method of Laminatin, Reticulation, Fusing, and Electroforming skills. In case of C2200, the brass, the A. C. TIG welding method is better under 2mm slight plate; the D.C. TIG welding is better upper 2mm plate; and 250~300$^{\circ}C$ is recommended for remain heat treatment. In case of C5210, not having Hydrogen in high temperature return period, doesn't need Oxygen in high temperature and hardening in comparative high temperature neither, it is good for welding. It contains Sn 2-9% ad P 0.03-0.4% generally; and in accordance with the growth rate of Sn contain amount, the harden temperature boundary become broad. In case of cold moment after welding, they are recommended that higher speed TIG welding, smaller melting site and less than 200$^{\circ}C$ for pre-heating temperature. In case of C7701, the 10-20% Ni, 15-30% Zn are widely used.. If it is upper 30% Zn, it become (${\alpha}+{\beta}$) system and adhesive power rate become lower, and the productivity become lower in low temperature but the productivity become higher in high temperature. Nickel Silver's resistance of electricity is well; and the heatproof and incorrodibility is good, too. Lastly, in case of C8113, good at persistence in salty and grind; high in strength of high temperature. In case of white brass, contain 10-30% Nickel and hardened in high temperature and become single phrase. For these reason, the crystallization particles easily become large, if the resistance become higher small amount of Pb, P, S separation rate become higher.

  • PDF

Influence of Soil Temperature on Growth and Nodulation Competition of Bradyrhizobium sp. Strains in the Rhizosphere of Peanut (온도(溫度)가 땅콩근류균(根瘤菌)의 근류형성(根瘤形成) 경합(競合)에 미치는 영향(影響))

  • Lee, Sand-Bok;Choi, Youn-Hee;So, Jae-Don;Kim, Moo-Key
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.26 no.3
    • /
    • pp.197-203
    • /
    • 1993
  • Greenhouse experiments were conducted to avaluate strain competition, nodulation, patterns of nodule occupancy and population changes of Bradyrhizobium sp. strain HCR-46 $str^{r}cep^{r}$ and CB756 $str^{r}rif^{r}$ in the rhizosphere of peanut(Arachis hypogaea L.) under different root temperatures. Inoculated with two strains using seed coating with peat slurry under different root temperatures, population of each strain in the rhizosphere increased with plant growth and multiplication rate of inoculum in the unit weight of root were showed the highest from 10 to 15days after sowing. The multiplication rate of inoculum in the rhizosphere was $28^{\circ}C$>$34^{\circ}C$>$22^{\circ}C$. The density of HCR-46 $str^{r}cep^{r}$ was more increased than that of CB756 $str^{r}rif^{r}$ under $22^{\circ}C$ and $28^{\circ}C$. While the density of two strains showed no difference under $34^{\circ}C$. Inoculated with HCR-46 $str^{r}cep^{r}$ and CB756 $str^{r}rif^{r}$, respectively at 22, 28 and $34^{\circ}C$, nodulation of each strain was dominated in its inoculation portion. Inoculated with the mixture of HCR-46 $str^{r}cep^{r}$ and CB756 $str^{r}rif^{r}$, occupancy rate of HCR-46 $str^{r}cep^{r}$ was dominated over that of CB756 $str^{r}rif^{r}$ at $22^{\circ}C$ and $28^{\circ}C$, but that was similar between them at $34^{\circ}C$. Dry mass, nodulation, nitrogen content per plant and nitrogenase activity showed higher at $28^{\circ}C$ than at $32^{\circ}C$ and $22^{\circ}C$, while those were higher in HCR-46 $str^{r}cep^{r}$ and mixing HCR-46 $str^{r}cep^{r}$ with CB756 $str^{r}rif^{r}$ than in CB756 $str^{r}rif^{r}$.

  • PDF

Uptake and Recovery of Urea-15N Blended with Different Rates of Composted Manure (퇴비의 혼합 시비율에 따른 Urea-15N의 이용율 및 회수율)

  • Ro, Hee-Myong;Choi, Woo-Jung;Yun, Seok-In
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.36 no.6
    • /
    • pp.376-383
    • /
    • 2003
  • To utilize composts more efficiently, combining composts with fertilizer to meet crop requirements is an appealing alternative. A pot experiment was conducted to study the effect of application rate of composted pig manure blended with fertilizer on the availability and loss of fertilizer-N. Chinese cabbage (Brassica campestris L. cv. Samjin) plants were cultivated for 30 and 60 days. 15N-Labeled urea ($5.24\;^{15}N\;atom\;%$) was added to soil at $450mg\;N\;kg^{-1}$, and unlabeled compost ($0.37\;^{15}N\;atom\;%$) was added at 0, 200, 400, and $600mg\;N\;kg^{-1}$. The amount of plant-N derived from urea was not affected by compost application at rate of $200mg\;N\;kg^{-1}$. However, compost application at 400 and $600mg\;N\;kg^{-1}$ significantly (P<0.05) increased plant assimilation of N from urea irrespective of sampling time, probably because of physicochemical changes in the soil properties allowing urea-N to be assimilated more efficiently. The amount of immobilized urea-N increased with increasing rate of compost application at both growth periods, as the results of increased microbial activities using organic C in the compost. Total recovery of urea-N (as percentage of added N) by Chinese cabbage and soil also increased with increasing rate of compost from 71.5 to 95.6% and from 67.0 to 88.2% at the 30- and 60-days of growth, respectively. These results suggest that increasing rate of compost blending increases plant uptake of fertilizer-N and enhances immobilization of fertilizer-N, which leads to decrease in loss of fertilizer-N. However, information about the fate of immobilized N during future crop cultivation is necessary to verify long-term effect of compost blending.

Effect of Peking-Duck By-Product Extracts Supplemented with Medicinal Herbs on Serum Heavy Metal Levels and Blood Parameters of Rats Exposed to Lead and Mercury (한약재를 첨가한 오리부산물 추출액이 납과 수은에 노출된 흰쥐 혈청의 중금속 및 혈액지표에 미치는 영향)

  • Park, Sung-Hye;Shin, Eon-Hwan;Park, Sung-Jin;Ran, Jong-Hyun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.4
    • /
    • pp.476-483
    • /
    • 2005
  • This experiment was planned to develop a functional supplement by food resources to prevent and lessen the deleterious effects caused by environmental pollutants such as polluted food, air, water and heavy metals. The goal of this study was to investigate the effects of peking-duck extracts supplemented with six kinds of medicinal herbs (DJ) on the intoxication of lead and mercury in rats. Sprague-Dawley rat weighing $150g\pm15g$ g, were randomly assigned to 5 groups, basal diet only (NCG), heavy metal without DJ injection (HCG), heavy metals and DJ (3 mg/mL) injection (HMLD), heavy metal and DJ (30 mg/mL) injection (HMMD), heavy metal and D] (300 mg/mL) injection (HMHD). Mecury (Hg) and lead (Pb) injected at the level of 50 ppm for 17 days. Also DJ oral feeding was continued for 31 days. The result of this study were as follows; Food intake and body weight gain in heavy metal administered groups were lower than those of control group (NCG). The activities of GOT, GPT and BUN level were significantly reduced in DJ-treated groups as compared to HCG. DJ was shown to suppress the accumulation of Hg and Pb in serum. The results suggest that DJ might have protective effect on Hg and Pb intoxication.

Studies on Solvent Extraction and Analytical Application of Metal-dithizone Complexes(I). Separation and Determination of Trace Heavy Metals in Urine (Dithizone 금속착물의 용매추출 및 분석적 응용(제1보). 뇨중 흔적량 중금속 원소의 분리 정량)

  • Jeon, Moon-Kyo;Choi, Jong-Moon;Kim, Young-Sang
    • Analytical Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.336-344
    • /
    • 1996
  • The extraction of trace cobalt, copper, nickel, cadmium, lead and zinc in urine samples of organic and alkali metal matrix into chloroform by the complex with a dithizone was studied for graphite furnace AAS determination. Various experimental conditions such as the pretreatment of urine, the pH of sample solution, and dithizone concentration in a solvent were optimized for the effective extraction, and some essential conditions were also studied for the back-extraction and digestion as well. All organic materials in 100 mL urine were destructed by the digestion with conc. $HNO_3$ 30 mL and 30% $H_2O_2$ 50 mL. Here, $H_2O_2$ was added dropwise with each 5.0 mL, serially. Analytes were extracted into 15.0 mL chloroform of 0.1% dithizone from the digested urine at pH 8.0 by shaking for 90 minutes. The pH was adjusted with a commercial buffer solution. Among analytes, cadmium, lead and zinc were back-extracted to 10.00 mL of 0.2 M $HNO_3$ from the solvent for the determination, and after the organic solvent was evaporated, others were dissolved with $HNO_3-H_2O_2$ and diluted to 10.00 mL with a deionized water. Synthetic digested urines were used to obtain optimum conditions and to plot calibration-eurves. Average recoveries of 77 to 109% for each element were obtained in sample solutions in which given amounts of analytes were added, and detection limits were Cd 0.09, Pb 0.59, Zn 0.18, Co 0.24, Cu 1.3 and Ni 1.7 ng/mL, respectively. It was concluded that this method could be applied for the determination of heavy elements in urine samples without any interferences of organic materials and major alkaline elements.