• Title/Summary/Keyword: 흡수계수

Search Result 780, Processing Time 0.033 seconds

A Study on Measurements of Optical Absorption Coefficients of Biological tissue (생체조직의 광학적 흡수계수 측정에 관한 연구)

  • 임현수;김남중
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.213-220
    • /
    • 1999
  • In this study, we measured the absorption coefficient of the tissues of mouse (brain, heart, liver, muscle and tumor) and human brain (normal and tumor) in the wavelength between 500nm~900nm. The optical coefficient is a representative of the characteristics of the materials. So, we can characterize the biological tissue with the optical coefficients. Using the spectrograph monometer and PDA(Photo Diode Array), we experimented with quick-frozen sectioned specimens. Because the optical coefficient is concerned with the conformation and biochemical component of the biological tissue, we experimented as the wavelength between 500nm~900nm on the normal and tumor samples of the animal and human. For the mouse, there are distinctive differences of the absorption coefficients between normal tissues and tumor. The absorption coefficient of the normal tissue varies 0.1~0.2cm$^{-1}$ with wavelength. But, the absorption coefficient of the brain tumor is changed round about 0.4~0.5cm$^{-1}$ as the wavelength. The absorption coefficients we measured can be a useful implement to detect diseases.

  • PDF

Analysis of collision absorption test on safety helmet (안전모 충격 흡수 성능에 관한 분석)

  • Sin, Un-Cheol
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.11a
    • /
    • pp.93-99
    • /
    • 2011
  • 안전모는 낙하, 비례물에 대한 두부를 보호하는 보호구로 낙하물의 충격을 일부 흡수하여 완화시켜주는 기능을 하고 있다. 안전모 충격 흡수 성능으로 최고전달충격력이 있으나 낮을수록 성능이 좋은 것으로 나타나지만 안전모 제조과정에서 얼마 만큼의 충격이 흡수되는지는 알 수 없었다. 이로 인하여 성능 향상을 위한 충격력의 명확한 제어 가능한 성능 향상의 기준을 잡는데 어려움이 있었다. 본 연구에서는 충격량과 연관된 반발계수로 충격흡수 성능의 정도를 찾고자 하였다. 연구 대상은 시중에서 주로 착용되고 있는 ABS 재질의 안전인증 합격품을 대상으로 선정 하였다. 연구 방법으로는 운동량과 충격량의 이론으로 안전모 충격흡수성능 시험장치를 활용하여 인두에 전달된 충격량을 활용하여 충격흡수시의 반발계수를 구하고, 충격을 흡수치 않을 때를 가정하여 추정 충격력 곡선을 유도하고 충격흡수 전의 추정 최고 전달충격력과 반발계수를 구하여 충격흡수의 성능을 나타내었다. 연구결과 국내 안전인증 H사의 안전모의 최고전달충격력은 4100 N 이였고, 충격흡수 성능은 400 N 으로 약 9 %를 흡수되는 것으로 나타났다.

  • PDF

Nonlinearity of Traveling-wave Photodetector (진행파형 광 검출기의 비선형성)

  • Moon Yon-Tae;Yun Young-Seol;Choi Young-Wan
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.50-53
    • /
    • 2004
  • 진행파형 광 검출기의 흡수영역에 입사되는 광전력은 흡수계수의 비로써 흡수되어 광전류를 생성한다. 흡수계수는 입사되는 작은 광전력에 독립적이지만, 충분히 큰 광전력에 대해서는 비선형적 함수가 된다. 본 논문에서는 입사되는 광전력의 크기에 따라 흡수계수가 비선형적으로 변화하는 식을 광포화 현상을 포함하여 모델링 하였고, 모델링 한 식을 사용하여 흡수영역에서 생성된 광전류를 계산하였다. 포화흡수로 인해 생성된 광전류가 비선형 특성이 나타남을 모의실험으로 계산하였다. 위의 결과를 입력 광전력에 독립적인 흡수계수를 이용하여 계산한 광전류와 비교하였다. 그리고 입사되는 광전력에 따라 생성된 비선형적 광전류의 특성을 투-톤 실험을 통해 고조파 성분으로 계산하였다.

  • PDF

Measurement of field-induced absorption changes in an electroabsorption waveguide using photocurrent (전계흡수형 도파로에서 광전류를 이용한 전계에 따른 흡수변화의 측정)

  • 강병권;박승한;최중길
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.3
    • /
    • pp.254-258
    • /
    • 1999
  • We propose a simple technique to obtain field-induced absorption changes of an electroabsorption waveguide by using photocurrent generated inside a waveguide. Photocurrent proportional to the absorbed power and displaying Fabry-Perot interference fringes were observed and the field-induced absorption changes were derived from the ratio of resonant and anti resonant currents in the photocurrent spectra. The field-induced absorption change of InGaAsP waveguide for 1.5V reverse bias voltage at 1.55 $\mu\textrm{m}$ was determined to be $~157\cm^{-1}$.

  • PDF

Measurement of optical coefficients of multiple scattering media by using frequency domain spectroscopy (주파수 영역 분광법을 이용한 다중산란 매질의 광학계수 측정)

  • 전계진;윤길원;김건식;전성만;박승한
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.5
    • /
    • pp.357-363
    • /
    • 1999
  • A frequency domain spectroscopic system was constructed to investigate the optical properties of multiple scattering media. The alternating current (AC) and phase lag components of backscattered light were measured by using the heterodyne detection method. Absorption and transport scattering coefficients were computed from the values based on diffusion theory. Predictions showed excellent matches in comparison with actual values of absorption and scattering. Predictable ranges of the optical coefficients were analyzed in terms of the distance between light source and detector, and modulation frequencies. A proposed compact experimental set-up using laser diodes can be utilized to estimate non-invasively the optical properties of multiple scattering media such as biological tissues.

  • PDF

Model Simulation for Assessment of Image Acquisition Errors Affecting Electron Tomography (영상 자료 획득시의 오류가 전자토모그래피 결과에 미치는 영향 고찰-모델 시뮬레이션을 중심으로)

  • Jou, Hyeong-Tae ;Lee, Su-Jeong;Kim, Youn-Joong;Suk, Bong-Chool
    • Applied Microscopy
    • /
    • v.38 no.1
    • /
    • pp.51-61
    • /
    • 2008
  • This simulation study examined the effect of data acquisition error including the data type of TEM image, and incident beam intensity of the tilt series on 3D tomograms. Simulation was performed with the 3D head phantom model of Kak and Slaney, and the slightly modified 3D head phantom model with enhanced difference in absorption coefficients. Reconstructed tomogram for the original head phantom model using 8-bit gray-scale image was distorted with extremely high level of noise, while an acceptable result was obtained for the modified model. The results for the original model using wrong formulation for the transmitted beam intensity was proved to be incorrect. The high level of noise along the z direction was found in case of the modified model. On the other hand, the wrong value of incident beam intensity in both models gave distorted results. In order to reconstruct an artifacts-free 3D structure from the projections with invisible features in electron tomography, the 16-bit projection images should be used with the correct incident beam intensity which is applied to Beer's law.

Study of Aerosol Light Absorption Measurement Operated in a Vehicle Using an Interferometer (간섭계를 이용한 차량 기반 에어로졸 광흡수 측정 연구)

  • Lee, Jeong-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1317-1324
    • /
    • 2011
  • We propose a method operated in a vehicle to measure light absorption of particles in atmosphere. The advantage of this method is that it is insensitive to light scattering and hence can be used for the direct measurement of the light absorption coefficient without suffering from light scattering. With this method atmospheric light absorption can be measured at a time constant of 10 s. Further, our method allows for the real-time measurement of light absorption near a highway. The light absorption coefficients were high near a race track, an airport and the main gate where vehicles emitted carbonaceous particles.

Selection of proper wavelenth for determination of CDOM absorption coefficient using hyperspectral images in upstream reach of Baekje weir (백제보 상류하천구간의 초분광 영상을 이용한 CDOM 흡수계수 결정을 위한 적정파장 선정)

  • Kim, Jinuk;Jang, Wonjin;Lee, Yonggwan;Park, Yongeun;Kim, Seongjoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.85-85
    • /
    • 2021
  • CDOM(Colored or Chromophoric Dissolved Organic Matter)은 바다, 호수 및 강에서 담수, 오수, 퇴적물 등으로부터 공급된 유기물질의 일종으로 가시광선에서 빛을 흡수하는 성질을 가지며, 2016년부터 환경부에서 선정한 하천, 호수 등 방류수의 수질오염 표준인 TOC(Total Organic Carbon)를 간접 추정할 수 있는 매개변수가 될 수 있다. 따라서, 본 연구에서는 백제보 상류 23 km 구간을 대상으로 2개년(2016~2017) 중 7일의 초분광영상 자료를 활용하여 내륙지역의 CDOM에 대한 적정 반사도 밴드값(Rrs)과 CDOM을 추정하는 알고리즘을 개발하고자 한다. CDOM은 흡수계수(αCDOM)를 통해 간접 추정되며, 흡수계수의 기준 파장값(λ)은 연구별로 350 nm, 375 nm, 400 nm, 412 nm 및 440 nm 등 다르게 나타난다. 초분광영상은 AsaFENIX 초분광 센서에서 관측된 380~970 nm까지 4 nm 간격, 127개 대역의 분광해상도와 2 m의 공간해상도를 가진 영상을 활용하였으며, 자료의 연속성을 위해 smoothing 기법을 활용하여 가공하였다. 추정 알고리즘은 Random forest를 활용하였으며, 70%의 trainning과 30%의 test로 구분하여 적용하였다. 산출된 CDOM은 결정계수(R2), Nash-Sutcliffe efficiency(NSE)를 이용하여 실측 CDOM과 비교하였다. 흡수계수별 CDOM의 산정 결과 αCDOM(350 nm)의 trainning, test에서 각각 R2가 0.71, 0.74, NSE가 0.25, 0.49로 가장 높았으며, 적정 반사도 밴드값은 Rrs(466), Rrs(493), Rrs(548), Rrs(641)를 사용하였을 때 trainning, test에서 각각 R2가 0.93, 0.90, NSE가 0.85, 0.69로 가장 높게 나타났다.

  • PDF

Infrared Absorption in $XAs_2S_3-(1-X)GeS_2$ Glassses in Multiphonon Region ($XAs_2S_3-(1-X)GeS_2$ 유리의 Multiphonon 영역에서의 적외선 흡수)

  • 마동성
    • Journal of the Korean Ceramic Society
    • /
    • v.22 no.3
    • /
    • pp.67-71
    • /
    • 1985
  • 2.5~40$mu extrm{m}$ 영역에서 $XAs_2S_3-(1-X)GeS_2$ 유리의 적외선 흡수에 관하여 연구했다/ Lucovsky와 그의 연구팀이 제창한 ""분자모델""에 의하면 $8-20\mu\textrm{m}$ 영역에서 위의 유리물질의 multiphonon 흡수대는 고립된 각 분자의 기본진동대의 overtone 및 combination 과 같다. 그러므로 multiphonon 흡수영역에서 AsY3 와 GeY3의 기본진동수를 모두 가지고 있는 combination 대는 관찰되지 않고 또한 혼합된 $XAs_2S_3-(1-X)GeS_2$ 유리의 흡수계수는 순수한 $As_2Y_3$$GeY_2$ 유리의 흡수계수를 더한 것으로 표현된다. 실험에서 얻은 흡수계수는 이 분자모델로부터 예상되는 값과 잘 일치한다.값과 잘 일치한다.

  • PDF

Derivation of Photon Energy Fluence and Mass Energy Absorption Coefficient for 1 Gy Absorbed Dose of Water in Brachytherapy using Ir192 Source (Ir192 선원을 이용한 근접치료에서 물 흡수선량 1 Gy에 대한 광자에너지 플루언스와 질량에너지흡수계수 유도)

  • Kim, Jong-Eon;Ahn, Il-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.61-66
    • /
    • 2022
  • The purpose of this study is to derive photon energy fluence and mass energy absorption coefficient for 1 Gy of absorbed dose of water in brachytherapy using an Ir192 source. From the radiotherapy physics written by Khan, the half-value of lead for the gamma ray beam of the Ir192 source was obtained. The linear attenuation coefficient and the mass attenuation coefficient were calculated from the obtained half-value layer of lead. By matching the calculated lead mass attenuation coefficient with the NIST mass attenuation coefficient data, the photon energy of the matching mass attenuation coefficient was determined as the effective energy. By matching the determined effective energy with the photon energy of the NIST data on the mass energy absorption coefficient of water, the mass energy absorption coefficient of water was obtained as 0.03273 cm2/g(32.73 cm2/kg). The photon energy fluence was calculated as 0.03055 J/cm2 by dividing the obtained mass energy absorption coefficient (32.73 cm2/kg) by the absorbed dose of water 1 Gy.