• Title/Summary/Keyword: 흡광광도법

Search Result 65, Processing Time 0.024 seconds

Spectrophotometric Determination of Aminoglycoside Antibiotics Based on their Oxidation by Potassium Permanganate (과망간산포타슘에 의한 산화에 바탕을 둔 아미노글리코사이드 항생제의 분광광도법적 정량)

  • El-Didamony, A. M.;Ghoneim, A. K.;Amin, A. S.;Telebany, A. M.
    • Journal of the Korean Chemical Society
    • /
    • v.50 no.4
    • /
    • pp.298-306
    • /
    • 2006
  • A rapid, simple and sensitive validated spectrophotometric methods have been described for the assay of neomycin and streptomycin either in pure form or in pharmaceutical formulations. The proposed methods were based on the oxidation of the studied drugs by a known excess of potassium permanganate in acidic medium and estimating the unreacted permanganate with amaranth dye (method A), acid orange II (method B), indigocarmine (method C), and methylene blue (method D), in the same acid medium at a suitable lmax=521, 485, 610 and 664 nm, respectively. Beers law is obeyed in the concentration range of 5-10 and 2-7 mg mL-1 for neomycin and streptomycin, respectively. The apparent molar absorptivity and sandell sensitivity values are in the range 5.47-6.20104, 2.35-2.91105 L mol-1 cm-1 and 7.57-8.59, 5.01-6.2 ng cm-2 for neomycin and streptomycin, respectively. Different variables affecting the reaction were studied and optimized. The proposed methods were applied successfully to the determination of the examined drugs either in a pure or pharmaceutical dosage forms with good accuracy and precision. No interferences were observed from excipients and the results obtained were in good agreement with those obtained using the official methods.

Analytical Studies of $H_2O_2$-Producing Oxidase Systems ($H_2O_2$-생성 산화효소계에 관한 분석 연구)

  • Younghee Hahn;Hae-Lim Cho
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.10
    • /
    • pp.874-880
    • /
    • 1993
  • Spectrophotometric enzymatic analysis and amperometric enzymatic analysis for the determinations of glucose and ethanol were studied utilizing glucose oxidase (GO) and alcohol oxidase (AO), respectively, which commonly consume $O_2$ and produce $H_2O_2$. For the determination of glucose, $H_2O_2$ were coupled to $K_4Fe(CN)_6$ via peroxidase producing $K_3Fe(CN)_6$ whose absorbance was measured at 418 nm or whose diffusion current was measured on the glassy carbon electrode at an applied potential of -55 mV vs. Ag/AgCl (sat. KCl) reference electrode. Amperometric analysis was 1000 times more sensitive as well as 10 times better in the linear concentration range than spectrophotometric analysis. For the determination of ethanol, AO only was used for the enzymatic analysis, since $K_3Fe(CN)_6$ was completely disappeared as soon as AO was added. Either rate of $H_2O_2$ produced was amperometrically measured at +0.900 V or rate of $O_2$ consumed was measured at -0.500 V vs. Ag/AgCl(sat. KCl) reference electrode.

  • PDF

Evaluation of Odors and Odorous Compounds from Liquid Animal Manure Treated with Different Methods and Their Application to Soils (액상 가축분뇨의 처리 및 토양환원에 따른 악취 및 악취물질의 평가)

  • 고한종;최홍림;김기연;이용기;김치년
    • Journal of Animal Science and Technology
    • /
    • v.48 no.3
    • /
    • pp.453-466
    • /
    • 2006
  • To comply with stricter regulations provoked by increasing odor nuisance, it is imperative to practice effective odor control for sustainable livestock production. This study was conducted to assess odor and odorous compounds emitted from liquid animal manure with different treatment methods such as Fresh Manure(without treatment, FM), Anaerobic Digestion(AD) and Thermophilic Aerobic Digestion(TAD) and their application to soil. Air samples were collected at the headspace of liquid manure, upland and paddy soil, and analyzed for odor intensity and offensiveness using an olfactometry; odor concentration index using odor analyser; nitrogen-containing compound such as ammonia(NH3) using fluorescence method; and sulfur containing compounds such as hydrogen sulfide(H2S), methyl mercaptan(MeSH), dimethyl sulfide(DMS) and dimethyl disulfide(DMDS) using gas chromatography-pulsed flame photometric detector, respectively. Odor intensity, offensiveness and concentration index from TAD liquid manure was statistically lower than those from FM and AD(p<0.01). Mean concentrations of H2S, MeSH, DMS, DMDS and NH3 were 65.93ppb, 18.55ppb, 5.26ppb, 0.33ppb and 10.57ppm for liquid manure with AD; and 5.15ppb, 0.97ppb, 0.80ppb, 0.56ppb and 1.34ppm for liquid manure with TAD, respectively. More than 60% of malodorous compounds related to nitrogen and sulfur were removed by heterotrophic microorganisms during TAD treatment. When liquid manure was applied onto upland and paddy soil, NH3 removal efficiencies ranged from 51 to 94% and 22 to 91% for AD and TAD liquid manure, respectively. The above results show that liquid manure with TAD is superior to AD and FM with respect to the odor reduction and odor problem caused by land applied liquid manure is directly related to the degree of odor generated by the manure treatment method.

Some Heavy, Metal Concentrations of Seawater and Mytilus coruscus in Ulsan Seaside (울산연안 해수 및 홍합 중의 중금속 함량)

  • Kim, Sun- Bun;Lee, Jong-Young;Jang, Bong-Ki
    • Journal of agricultural medicine and community health
    • /
    • v.21 no.1
    • /
    • pp.85-95
    • /
    • 1996
  • To examine the contamination in Ulsan coastal area, some heavy metal concentrations in sea water and Mytilus coruscus have been measured. Sea water samples were collected on April 6 in 1995 and Mytilus coruscus samples were collected on April 2 in 1995. Total number of sea water samples was 26 and that of Mytilus coruscus was 54. The sites where the samples collected were same in sea water and Mytilus coruscus. The method of analysis was atomic absorption spectrophotometer. The results indicated that the heavy metal concentrations of sea water were varied according to the sampling stations. The concentrations of cadmium, manganese, zinc in sea water collected in the coastal area near Mipo complex were higher than those of other coastal areas, and the concentrations of lead in sea water collected in the coastal area near petrochemical complex were higher than those of others. In general the concentrations of lead, zinc, copper in sea water were proportionate to those in Mytilus coruscus. The mean concentration rates of lead, cadmium, manganese in Mytilus coruscus inhabiting in Ulsan coastal area were similar, 1070, 1370 and 1300, respectively. The concentration rate of mercury was 80, the lowest value of other heavy metals, and that of copper was 6940, the highest value. Consequently it seems to be more desirable to use Mytilus coruscus as a sample to examine the contamination of coastal area than sea water.

  • PDF

Spectrophotometric Determination of Aluminium Ion in Drinking Water by Flow Injection Analysis (흐름주입분석법에 의한 음용수 중 알루미늄 이온의 분광광도법 정량)

  • Choi, Yong-Wook;Jin, Jae-Young
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.5
    • /
    • pp.422-428
    • /
    • 2000
  • Optimum analytical conditions of the aluminium ion were established by flow injection analysis. Eriochrome Cyanine R(ECR) dye reacts with the aluminium ion at pH 6.0 to form a complex that exhibits maximum absorption at 535 nm. Reaction conditions including the mixing and the reaction coil length, the concentration and the pH of the buffer solutio, temperature, and injection loop volume were optimized to intro-duce this reaction into flow injection analysis. The results were as follows. A mixing coil length of 0.5 m and a reaction coil length of 4.0 m, the pH 6.0 and 1M of acetate buffer solution, the ECR concentration of 0.56 mM, the reaction temperature of 40$^{\circ}C$, the injection loop volume of 300${\mu}L$ were chosen as optimum conditions. Under these conditions the detection limit of the aluminiumion was less than 0.05 mg/L and the repeatability was better than 1%. A sampling frequency of 24 times for an hour was achieved. Interfering ions such as $F^-$, HP$O_4^{2-}$, $Fe^{2+}$, $Fe^{3+}$, $Mn^{2+}$, and other anions were tested, interference did not occur up to 1,000mg/L of ion concentration and up to 2,CO0mg/L of sulfate ion con-centration. This method was applied for the determination of aluminium ion in tap water and ground water of Jeonju and the Gochang area. The results showed that the aluminium residual in tap water of the Jeonju area was at a mean of 0.478mg/L and that in tap water of the Gochang area was at a mean of 0.278mg/L. Aluminium ion residual of the tap waters in the Jeonju area was higher level than that in the Gochang area. Aluminium residual in the ground water of the Jeonju area was 0.386 mg/L and was lower compared to 0.564 mg/L for the Gochang area.

  • PDF