• Title/Summary/Keyword: 흙의 열전도도

Search Result 8, Processing Time 0.025 seconds

Estimation of Thermal Conductivity of Weathered Granite Soils (화강풍화토의 열전도도 산정에 대한 연구)

  • Park, Hyunku;Park, Hansol;Lee, Seung-Rae;Go, Gyu-Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2C
    • /
    • pp.69-77
    • /
    • 2012
  • In general, geothermal energy pile and horizontal ground heat exchangers are installed in shallower depths than conventional vertical ground coupled heat pumps. Consequently their heat exchange performance is strongly governed by thermal conductivity of soil layer. Previous studies have shown that the thermal conductivity of soil above ground water table significantly affects the heat exchange rate because of partially saturated condition in soil and consequent variation of soil thermal conductivity. This paper presents a study result on the prediction of thermal conductivity of weathered granite soils. For weathered granite soils sampled from 5 locations, thermal conductivity tests were conducted with varying porosity and degree of saturation. The existing thermal conductivity models in literatures appeared inappropriate to the weathered granite soils. Hence, an empirical equation was proposed in this paper and its validity was examined by applying it to thermal conductivity test results obtained for weathered granite soils in this study and from literatures.

Characterization of thermal conduction for gas hydrate bearing in-situ sediments (울릉분지 현장 시료와 F110표준사를 이용한 GH함유토의 열전달 양상 분석)

  • Kim, Young Jin;Yun, T.S.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.148.1-148.1
    • /
    • 2011
  • 본 연구에서는 가스 하이드레이트의 미래 상업생산을 위한 연구활동으로 동해 울릉분지 현장시료를 채취하여 가스 하이드레이트 함유토의 열전도 현상에 관한 연구를 실시하였다. 두 종류의 현장시료를 이용하여 메탄 하이드레이트를 생성하여 공극비 및 포화도에 따라 조건을 달리하여 실험을 수행하였다. 열전도도 측정을 위하여 Transient Plane Source (TPS) 기법을 이용하였다. 현장시료의 사용에 앞서 예비실험으로써 F110표준사를 사용, 비교 분석 자료로써 활용하였다. 하이드레이트 생성 확률을 높이는 기법으로써 불포화시료를 동결, 해동 후 가스를 주입하였으며 동결된 불포화 시료의 열전달양상의 변화를 함께 고찰하였다. 실험결과, 하이드레이트의 포화도가 증가함에 따라 함유토의 열전도도의 증가함을 알 수 있어다. 거의 동일한 물과 GH의 열전도도에도 불구하고 하이드레이트 결정화 작용으로 동일한 포화도의 불포화 시료와 비교하여 약간의 상승을 보였다. 또한 공극비 및 흙을 구성하는 미네랄의 성분에 따라 열전도도의 발현 양상이 상이함을 관찰하였다. 이에 차후 하이드레이트 생산을 위한 현장 측정 및 전산 모사시 이에 관한 고려가 필요할 것으로 사료된다.

  • PDF

Study on Evaluation of Effective Thermal Conductivity of Unsaturated Soil Using Average Capillary Pressure and Network Model (평균 모세관압과 네트워크 모델을 이용한 불포화토의 유효 열전도도 산정에 관한 연구)

  • Han, Eunseon;Lee, Chulho;Choi, Hyun-Jun;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.1
    • /
    • pp.93-107
    • /
    • 2013
  • Thermal conduction of the particulate composites or granular materials can be widely used in porous materials and geotechnical engineering. And it has continued to develop "effective thermal conductivity" of medium by modeling energy relationship among particles in medium. This study focuses on the development of the effective thermal conductivity at the unsaturated conditions of soils using the modified network model approach assisted by synthetic 3D random packed systems (DEM method, Discrete Element Method) at the particle scale. To verify the network model, three kinds of glass beads and the Jumunjin sand are used to obtain experimental values at various unsaturated conditions. The PPE (Pressure Plate Extractor) test is then performed to obtain SWCC (Soil-Water Characteristic Curve) of soil samples. In the modified network model, SWCC is used to adjust the equivalent radius of thermal cylinder at contact area between particles. And cutoff range parameter to define the effective zone is also adjusted according to the SWCC at given conditions. From a series of laboratory tests and the proposed network model, the modified network model which adopts a SWCC shows a good agreement in modeling thermal conductivity of granular soils at given conditions. And an empirical correlation between the fraction of the mean radius (${\chi}$) and thermal conductivity at given saturated condition is provided, which can be used to expect thermal conductivity of the granular soils, to estimate thermal conductivity of granular soils.

Effect of Temperature on Particle Structure and Strength Characteristic of Sand and Weathered Granite Soil (온도변화가 모래 및 화강풍화토의 입자구조 및 강도 특성에 미치는 영향)

  • Yoo, Chung-Sik;Shin, Seung-Min
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.2
    • /
    • pp.57-70
    • /
    • 2015
  • This paper presents the results of an investigation into the effect of forced temperature change cycles on physical and mechanical properties of sand and weathered granite soil. The effect of forced temperature change cylecs on the particle arrangement and the thermal conductivity was first investigated. A series of triaxial compression tests on the soils were also performed to look into the effect of temperature change cycles on the stress-strain-strength behavior. The results indicated that the forced temperature change cycle does not significantly affect the particle arrangement and thermal conductivity. It is shown however that the heating duration showed some effect on the deviatoric stress at failure while no significant effect due to the number of heating-cooling cycle was observed.

Experimental Study for Thermal Characteristics of Frozen Soil Samples (동토 시료의 열적 특성 분석을 위한 실험적 연구)

  • Sewon, Kim;Sangyeong, Park;Jongmuk, Won;YoungSeok, Kim
    • Journal of the Korean Geosynthetics Society
    • /
    • v.21 no.4
    • /
    • pp.31-40
    • /
    • 2022
  • Recently, the Arctic resource development project, where undeveloped energy resources (oil, natural gas, etc.) are deposited, is actively being promoted for the perspective of diversifying the construction market and developing future energy resources. However, the frozen ground always has problems such as sinking and frost-heaving due to extreme weather. Therefore, it is necessary to analyze the thermal characteristics of the frozen soil to secure the stability of the ground structure. In this study, a series of laboratory tests were performed to evaluated the thermal characteristics of frozen soil samples in the oil sand field in Alberta, Canada. In additon, it was compared with the results of domestic(Gangwond-do) sample performed under the same conditions. As a comparison results of the experiments, it was clarified that the different frozen water content and thermal conductivity characteristics by temperature after completion of freezing could affect the frozen soil behavior.

Material Characteristics of Traditional Bricks used in the Royal Tomb of King Muryeong, Gongju, Korea and Its Reproduction Bricks (무령왕릉에 사용된 전돌과 재현 전돌의 재료학적 특성)

  • Kwon, Yang Hee;Hong, Sung Gul
    • Journal of Conservation Science
    • /
    • v.30 no.3
    • /
    • pp.287-298
    • /
    • 2014
  • This study investigates the material properties of the traditional bricks used in the royal tomb of King Muryeong. Compressive strengths, thermal conductivities, absorptance and the rate of residual moisture are measured by non-destructive experiments. Compressive strength of the traditional bricks is estimated by using the ultrasonic wave velocity and the absorptance. Based on the experimental results, the predicted compressive strengths using the ultrasonic wave velocity are unsuitable for the traditional bricks due to the rough surface and thickness variation of the specimens. The strengths using the absorptance are more suitable than those using the velocity because the predicted average strengths (28.69 MPa ~ 33.19 MPa) are close to building materials like normal strength concrete. In addition, the methods using the absorptance are not influenced by surface and thickness conditions of the specimens. The average thermal conductivities of the bricks measured by using Mathis TCi are close to those of soils (1.58 W/mK). The absorptance and the rate of residual moisture of the bricks are 1.6 % ~ 15 %, 0 % ~ 0.7 %, respectively.

Undrained Behavior of Weathered Granite Soil of Heating-Cooling Repeated Acts Using Temperature Control Triaxial Test (온도변화 삼축압축 실험을 이용한 Heating-Cooling 반복 작용시 화강풍화토의 비배수 거동)

  • Shin, Seung-Min;Sin, Chun-Won;Yoo, Chung-Sik
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.3
    • /
    • pp.1-12
    • /
    • 2016
  • In this study, the impact of sand and weathered granite soil is analyzed by changing the internal temperature from $20^{\circ}C{\sim}70^{\circ}C$C by installing a heating coil inside the triaxial cell. To check the effect on weathered granite soil due to increase of temperature and number of heating-coiling cycles are analyzed by measuring the temperature by using thermometer installed inside the triaxial cell and due to that deviator stress also occurred during the consolidated undrained test. To analyze the effect of weathered granite soil with change of temperature during undrained testing. The deviator stress and pore pressure is measured. As a result, pore pressure increases and the deviator stress decreases with rise of temperature.

Influencing Factors on Freezing Characteristics of Frost Susceptible Soil Based on Sensitivity Analysis (민감도 분석을 기반으로 한 시료의 동결 특성에 미치는 영향인자 분석)

  • Go, Gyu-Hyun;Lee, Jangguen;Kim, Minseop
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.8
    • /
    • pp.49-60
    • /
    • 2020
  • A fully coupled thermo-hydro-mechanical model is established to evaluate frost heave behaviour of saturated frost-susceptible soils. The method is based on mass conservation, energy conservation, and force equilibrium equations, which are fully coupled with each other. These equations consider various physical phenomena during one-dimensional soil freezing such as latent heat of phase change, thermal conductivity changes, pore water migration, and the accompanying mechanical deformation. Using the thermo-hydro-mechanical model, a sensitivity analysis study is conducted to examine the effects of the geotechnical parameters and external conditions on the amount of frost heave and frost heaving rate. According to the results of the sensitivity analysis, initial void ratio significantly affects each objective as an individual parameter, whereas soil particle thermal conductivity and temperature gradient affect frost heave behaviour to a greater degree when applied simultaneously. The factors considered in this study are the main factors affecting the frost heaving amount and rate, which may be used to determine the frostbite sensitivity of a new sample.