• Title/Summary/Keyword: 흉추

Search Result 152, Processing Time 0.032 seconds

Surgical Treatment for Metastatic Spinal Tumor (전이성 척추 종양의 수술적 치료)

  • Han, Chung-Soo;Kim, Ki-Tack;Soh, Jae-Ho;Lee, Jung-Hee;Shin, Dong-Jun
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2000
  • Purpose : Spine is one of the most common sites of the metastatic bone tumors. Conservative management such as chemotherapy or radiotherapy has been preferred in most cases. However, the neurologic deficit has not been usually improved, and the quality of life was poor. The purpose of this study was to show the efficacy of the surgical treatments for metastatic spinal tumors in terms of postoperative improvements of neurologic deficit and survival time. Materials and Methods : Authors have reviewed the literatures and analyzed 14 patients of metastatic spinal tumors who were received operative treatments between August 1991 and June 1999 at the our department of orthopaedic surgery. Results : The most frequent primary tumor was breast cancer in women and lung cancer in men. The thoracic region was the most common site. There was a preponderance of females over males, and the age ranged between 4th and 8th decade. The indications of surgical treatment comprised instability, progressive neurologic findings, resistance to radiotherapy, pathological fracture, long life expectancy( >6weeks), isolated metastasis and need for pathological diagnosis. The degree of preoperative neurological deficit might influence on the improvement of clinical symptoms after surgery. Conclusion : The surgical treatment reduced the neurological deficit and pain regardless of the operative methods. In the early stage of neurological deficit, the surgical treatment was important for better prognosis. Recently early active operative treatment was performed for metastatic spinal tumor to minimize the intractable pain and to prevent the progression of the neurologic deficit. Early intervention can improve the quality of life and long term survival.

  • PDF

An Epidemiologic Study of Metastatic Bone Tumor (전이성 골종양의 역학적 연구)

  • Kim, Jae-Do;Lee, Duk-Hee;Park, Jeong-Ho;Son, Young-Chan;Hong, Yonng-Gi;Son, Jeong-Hwan
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.1 no.1
    • /
    • pp.38-44
    • /
    • 1995
  • Metastatic bone tumor is the most common bone tumor and 32.5% of all primary malignant tumors are eventually metastasize to bone. Metastatic bone tumor has been more frequently encountered disease in the orthopedic fields due to the greater longevity of life of the patients with primary visceral cancers by major advances in early detection, diagnosis, and surgical/radiotherapeutic/chemotherapeutic treatment of primary and metastatic lesions. Therefore, the epidemiologic data about the incidences and the patterns of bone metastasis is important. We reviewed 417 patients who were diagnosed and treated for metastatic bone tumor at Kosin University Medical Center from 1985 to 1993 to analyse the primary lesion, age and sex distributions, location of bone metastasis, patterns of metastasis according to the primary. The results were as follows : 1. The common origin of bone metastasis were lung(29.5%), stomach(15.3%), breast(11.3%), unknown(7.7%), cervix(5.3%), liver(4.8%) in order of frequency. 2. There were 251 men and 166 women and their mean age was 54.8 years and the peak age incidence was in 6th decades. Most cases(85.3%) were occured beyond 5th decades. 3. The preferred sites of metastatic deposits were spine(64.0%), pelvis(40.5%), rib(38.8%), femur(36.7%), skull(21.1%), humerus(13.9%), scapula(13.0%) in order of frequency. In the spine, thoracic(42.1%), lumbar(39.1%), cervical(13.2%), sacral(5.6%) vertebrae were involved in order of frequency. 4. Multiple bone metastases were more common(73.1%) than single metastasis(26.9%). 5. In the lung cancer, the peak age incidence was 6th decades, and the preferred sites of bone metastasis were spine, pelvis, femur. 6. In the stomach cancer, the peak age incidence was 6th decades, and the preferred sites of bone metastasis were spine, femur, pelvis. 7. In the breast cancer, the peak age incidence was 5th decades, and the preferred sites of bone metastasis were spine, rib, pelvis. 8. In the bone metastasis with unknown primary site, the peak age incidence was 7th decades, the preferred sites of bone metastasis were spine, femur, pelvis, and the common histologic types were adenocarcinoma and squamous cell carcinoma.

  • PDF

Studies on the Interactions of $M_1-,M_2-receptors$ with Nicotinic Receptors in Rabbit Sympathetic Ganglia (가토 교감신경절에서 무스카린성 수용체 아형과 니코틴성 수용체의 상호작용에 대한 연구)

  • Kim, Jong-Keun;Rhu, Choon-Sik;Kang, Sam-Suk
    • The Korean Journal of Pharmacology
    • /
    • v.28 no.2
    • /
    • pp.171-179
    • /
    • 1992
  • Effects of a $M_1$ receptor antagonist, pirenzepine, a $M_2$ receptor antagonist, AF-DX116, and a nicotinic receptor antagonist, mecamylamine on the pressor responses to preganglionic sympathetic nerve stimulation (PNS) and McN-A-343 and DMPP in spinal (pithed) rabbits were investigated, in order to elucidate a functional role of $M_1$, $M_2$ and nicotinic receptors in ganglionic transmission. Pirenzepine and AF-DX116 selectively inhibited the McN-A-343-induced pressor response in chlorisondamine-treated rabbit and the BCh-induced bradycardia, respectively. Electrical stimulations of preganglionic sympathetic outflow at T8 level produced increases in blood pressure. Pirenzepine $(3\;{\mu}g/kg)$ significantly inhibited the PNS-induced pressor response and the degree of inhibition was not changed by increasing the doses to $100\;{\mu}g/kg$. AF-DX116 $(100\;{\mu}g/kg)$ had no effect on the PNS-induced pressor response. Mecamylamine inhibited the PNS-induced pressor response in a dose-dependent manner. The inhibitory action of mecamylamine was significantly augmented by combined-treatment with pirenzepine $(30\;{\mu}g/kg)$ but AF-DX116 $(100\;{\mu}g/kg)$ did not affect the inhibitory action of mecamylamine. McN-A-343 and DMPP elicited pressor response in the spinal rabbit. Pirenzepine and AF-DX116 dose-dependently inhibited the McN-A-343-induced pressor response but they did not affect DMPP-induced pressor response. Mecamylamine inhibited both pressor responses induced by McN-A-343 and DMPP. These results suggest that not only nicotinic receptors but also $M_1$ receptors play a facilitatory role in ganglionic transmission but $M_2$ receptors do not contribute the transmission in spinal (pithed) rabbits.

  • PDF

A Clinical Study on Multiple Myeloma (다발성 골수종의 임상적 고찰)

  • Hwang, Hyeong-Ki;Lee, Choong-Ki;Hyun, Myung-Soo;Shim, Bong-Sup;Lee, Hyun-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.2
    • /
    • pp.106-113
    • /
    • 1991
  • A clinical review of 31 cases of multiple myeloma which were diagnosed by criteria of the SWOG between May 1983 and February 1990 at Yeungnam University Hospital was done. The results were as followings : 1. The peak incidence was in 7th decade and male to female ratio was 1.8 : 1. 2. The most common presenting symptom at first diagnosis was bone pain (58%), but fever, dyspnea, dizziness and palpable mass were also noted. 3. The distribution of laboratory findings as following diagnostic criteria of Southwest oncology group(SWOG) : plasmacytoma on tissue biopsy was noted 6 cases, bone marrow plasmacytosis with more than 10% plasma cells was 22 cases, monoclonal globulin spike on serum electrophoresis was 24 cases, lytic bone lesions was observed 22 cases. 4. Initial clinical stages were classified as 2 cases in stage I, 3 cases in stage II, 26 cases in stage III(84%) 5. Immunoelectrophoresis revealed the distribution of IgG 64%, light chain 22%, IgA 10%. Kappa to Lambda ratio of 1.1 : 1. 6. Hematologic & biochemical fingins revealed anemia with <8.5% of hemoglobulin in 42%, hypercalcemia with < 10.6mg% of serum calcium in 22%, azotemia >2.0mg% of serum creatinine in 19%. 7. The multiple punched out lesion of bone x-ray examination were noticed skull(65%), rib(42%), L-spine(35%), pelvis(23%), T-spine(19%). The initial skeletal roentgenographic findings showed osteoporosis, osteolytic lesion and fracture in 55%, only osteolytic lesion in 23%, only osteoporosis in 10%. 8. Complications of multiple myeoloma, such as 10 cases of renal impairment, 8 cases of infection, 16 cases of compression fracture of spine were observed.

  • PDF

The Secondary Contiguous or Non-contiguous Subchondral Bone Impactions in Subaxial Cervical Spinal Injury: Incidence and Associated Primary Injury Patterns (축추이하 경추 손상에서 이차적으로 발생하는 연속적, 비연속적 연골하골 압박손상의 빈도와 원발부위 손상 패턴)

  • Han, Jun Gu;Kim, Yeo Ju;Yoon, Seung Hwan;Cho, Kyu Jung;Kim, Eugene;Kang, Young-Hye;Lee, Ha Young;Cho, Soon Gu;Kim, Mi Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.3
    • /
    • pp.232-243
    • /
    • 2014
  • Purpose : To evaluate the incidence of secondary contiguous or non-contiguous subchondral bone impactions (SBI) in subaxial cervical spinal injury and associated primary injury patterns. Materials and Methods: A retrospective review of computed tomography, magnetic resonance imaging, and medical records was carried out for 47 patients who had sustained a subaxial cervical spinal injury. Presence, number, level, and sites of secondary contiguous or non-contiguous SBI were recorded. To evaluate primary injury patterns, the level and number of primary injury sites of subaxial cervical spine injury, injury morphology, anterior/posterior discoligamentous complex (ADC/PDC) injury, posterior ligamentous complex (PLC) injury, spinal cord injury, and mechanism of injury (MOI) were analyzed. Differences in primary injury pattern of subaxial cervical spine injury and MOI between patients with and without SBI, and between contiguous or non-contiguous SBI were analyzed using the Mann-Whitney U test, Pearson's chi square test and Fisher's exact test. Results: Eighteen patients (18/47, 38.29%) had developed contiguous (n=9) or non-contiguous (n=9) SBI, most commonly involving T3 (15/47, 31.91%) and 3 levels (6/18, 33.33%). All SBIs had developed near the anterosuperior region of the body and the superior endplate and were the result of a high-impact MOI. SBIs were statistically significant in association with injury morphology and PLC injury (P=0.001, P=0.009, respectively) at the primary injury site. Non-contiguous SBI was more frequently accompanied by upper cervical spinal injuries in association with PDC injuries, as opposed to contiguous SBI, with statistical significance (P=0.009), while no other statistically significant differences were found. Conclusion: Secondary SBIs are common and probably associated with subaxial cervical spinal injuries with high energy compressive flexion forces.

The Study of Technical Error Analysis on BMD Using DEXA (이중 에너지 X선 흡수 계측법을 이용한 BMD 검사 시 발생할 수 있는 기술적인 오류 분석)

  • Kang, Yeong-Han;Jo, Gwang-Ho
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.229-236
    • /
    • 2006
  • Purpose: This study was conducted to search for the type of technical error in DEXA(dual-energy X-ray absorptiometry) and the effect of error to measurement of BMD. Materials and Methods: The changes of BMD($g/cm^2$, T-score) by patients information(Age, Weight, Height, Manopause age) input error and Confirming ROI error were investigated. Using spine phantom, we canned 10 times by age(5, 10), weight(10, 20 kg), height(5, 10 cm), manopause age(5, 10) increase & decrease respectively. Scanning region(L-spine, femur, Forearm) of 10 patients was calculated by changing ROI respectively. Analysis of difference for mean(precision 1%) were carried out. Results: The error of patient information(Age, Weight, Height, Manopause age) was not changed differently. In confirming ROI, the BMD and T-score of L-spine involving T-12 was decreased to $0.063\;g/cm^2$, 0.3 and involving L-5 increased to $0.077\;g/cm^2$, 0.5. In narrowing 1 cm of vertical line of ROI, the BMD and T-score decreased to $0.006\;g/cm^2$, 0.1 and in 2 cm, $0.021\;g/cm^2$, 0.15, each. In hip ROI, Upper and left shift(0.5 cm) of line was not influenced BMD and T-score. In 0.5 cm lower shift(lesser trochanter below), the BMD and T-score increased $0.031\;g/cm^2$, 0.3 and in 1 cm $0.094\;g/cm^2$, 0.65, each. In forearm ROI, the BMD and T-score decreased $0.042\;g/cm^2$, 0.9 involving 1 cm lower wrist. And expanding 1 cm of vertical line, the BMD and T-score decreased $0.008\;g/cm^2$, 0.1 and in 2 cm, $0.021\;g/cm^2$, 0.3, each. The L-spine, hip, forearm ROI error was changed differently. Conclusion: There are so many kinds of technical error in BMD processing. Errors according to age, weight, height, manopause age did not influent to $BMD(g/cm^2)$ and T-score. There are mean differences BMD and T-score in confirming ROI. For the precision exam, in L-spine processing, L1-4 have to confirmed without shift of ROI vertical line. In hip processing, the ROI have to included greater trochanter, femur head and lesser trochanter. In forearm processing, the ROI have to included wrist, radius and ulnar.

  • PDF

The Evaluation and Development of Head and Neck Radiation Protective Device for Chest Radiography in 10 Years Children (소아(10세) 흉부 방사선촬영에서의 두경부 방사선 방어기구 개발 및 평가)

  • Lee, Jun Ho;Lim, Hyun Soo;Lee, Seung Yeol
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.118-123
    • /
    • 2015
  • The frequency of diagnostic radiation examinations in medical institutions has recently increased to 220 million cases in 2011, and the annual exposure dose per capita was 1.4 mSv, 51% and 35% respectively, compared to those in 2007. The number of chest radiography was found to be 27.59% of them, the highest frequency of normal radiography. In this study, we developed a shielding device to minimize radiation exposure by shielding areas of the body which are unnecessary for image interpretation, during the chest radiography. And in order to verify its usefulness, we also measured the difference in entrance surface dose (ESD) and the absorbed dose, before and after using the device, by using an international standard pediatric (10 years) phantom and a glass dosimeter. In addition, we calculated the effective dose by using a Monte Carlo simulation-based program (PCXMC 2.0.1) and evaluated the reduction ratio indirectly by comparing lifetime attributable risk of cancer incidence (LAR). When using the protective device, the ESD decreased by 86.36% on average, nasal cavity $0.55{\mu}Sv$ (74.06%), thyroid $1.43{\mu}Sv$ (95.15%), oesophagus $6.35{\mu}Sv$ (78.42%) respectively, and the depth dose decreased by 72.30% on average, the cervical spine(upper spine) $1.23{\mu}Sv$ (89.73%), salivary gland $0.5{\mu}Sv$ (92.31%), oesophagus $3.85{\mu}Sv$ (59.39%), thyroid $2.02{\mu}Sv$ (73.53%), thoracic vertebrae(middle spine) $5.68{\mu}Sv$ (54.01%) respectively, so that we could verify the usefulness of the shielding mechanism. In addition, the effective dose decreased by 11.76% from $8.33{\mu}Sv$ to $7.35{\mu}Sv$ before and after wearing the device, and in LAR assessment, we found that thyroid cancer decreased to male 0.14 people (95.12%) and female 0.77 people (95.16%) per one million 10-year old children, and general cancers decreased to male 0.14 people (11.70%) and female 0.25 people (11.70%). Although diagnostic radiation examinations are necessary for healthcare such as the treatment of diseases, based on the ALARA concept, we should strive to optimize medical radiation by using this shielding device actively in the areas of the body unnecessary for the diagnosis.

Preliminary Result of Revision Fusion Surgery for Thoracolumbar Spine Using Revision Rod (Revision Rod를 이용한 흉요추 유합 재수술 예비 결과)

  • Youn, Yung-Hun;Cho, Kyu-Jung;Park, Ye-Su;Park, Jae-Woo;Park, Jin-Sung;Kwon, Won-Hwan
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.520-526
    • /
    • 2020
  • Purpose: The need for revision fusion surgery after spinal fusion has increased. A revision rod that connects to the previous rod was newly developed for revision surgery. The purpose of this study was to analyze the clinical and radiological results after spinal fusion revision surgery using revision rods. Materials and Methods: Twenty-one patients who underwent revision fusion surgery after spinal fusion in two university hospitals with minimum 1 year follow-up were reviewed. This study assessed 16 cases of adjacent-segment disease, four cases of thoracolumbar fracture, and one case of ossification of ligament flavum. The Oswestry Disability Index (ODI) and numerical rating scale (NRS) were evaluated as clinical outcomes, and the union rate, lordosis or kyphosis of the revision level, lumbar lordosis, T5-12 kyphosis, and proximal junctional kyphosis angle were evaluated as the radiological outcomes. Results: The average ODI was 54.6±12.5 before surgery and improved to 29.8±16.5 at the final follow-up. The NRS for back pain and leg pain was 5.0±1.7 and 6.4±2.0 before surgery, which changed to 2.9±1.6 and 2.9±2.2 at the final follow-up. Lumbar lordosis was 18.1°±11.9° before surgery and 21.1°±10.3° at the final follow-up. Proximal junctional kyphosis was 10.8°±10.1° before surgery, and 9.2°±10.5° at the final follow-up. These angles were not changed significantly after surgery. Bony union was successful in all cases except for one case who underwent posterolateral fusion. Conclusion: Revision surgery using a newly developed revision rod on the thoracolumbar spine achieved good clinical outcomes with successful bony union. No problems with the newly developed revision rod were encountered.

Effects of Change in Patient Position on Radiation Dose to Surrounding Organs During Chest Lateral Radiography with Auto Exposure Control Mode (자동노출제어장치를 적용한 흉부 측면 방사선검사 시 환자 위치 변화가 주변 장기의 선량에 미치는 영향)

  • Seung-Uk Kim;Cheong-Hwan Lim;Young-Cheol Joo;Sin-Young Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.903-909
    • /
    • 2023
  • The purpose of this study is to compare and analyze the effect of changes in the patient's central position on the exposure dose and image quality of surrounding organs during a chest lateral examination using an Auto Exposure Control(AEC). The experiment was conducted on a human body phantom. A needle was attached to the lower part of the center of the coronal plane of the phantom, and a lead ruler was attached to the lower part of the detector so that the 50 cm point was located at the lower center of the AEC ion chamber. The exposure conditions were 125 kVp, 320 mA, the distance between the source and the image receptor was 180 cm, and the exposure field size was 14 × 17 inches. Only one AEC ion chamber was used at the bottom center, and the density was set to '0' and sensitivity to 'Middle', and the central X-ray was incident vertically toward the 6th thoracic vertebra. With AEC mode applied, the 50 cm point of the needle and lead ruler were aligned and the phantom was moved 5 cm toward the stomach (F5) and 5 cm toward the back (B5), and the dose factor was analyzed by measuring ESD. The ESD of the thyroid gland according to the change in patient center position was 232.60±2.20 μGy for Center, 231.22±1.53 μGy for F5, and 184.37±1.19 μGy for B5, and the ESD of the breast was 288.54±3.03 μGy for Center, F5 was 260.97±1.93 μGy, B5 was 229.80±1.62 μGy, and the ESD of the center of the lung was 337.02±3.25 μGy for Center, F5 was 336.09±2.29 μGy, and B5 was 261.76±1.68 μGy. As a result of comparing the average values of dose factors between each group, the difference in average values was statistically significant (p<0.01), and each group appeared to be independent. As a result of the study, there was no significant difference in the dose to the thyroid, breast, and center of the lung according to the change in the patient's central position, except for the breast (10%) when the patient moved forward about 5 cm. However, movement of about 5 cm posteriorly resulted in an average dose reduction of 23.7%. Additionally, when the patient's central position was moved to the rear, image quality deteriorated.

Is a Camera-Type Portable X-Ray Device Clinically Feasible in Chest Imaging?: Image Quality Comparison with Chest Radiographs Taken with Traditional Mobile Digital X-Ray Devices (카메라형 휴대형 X선 장치는 흉부 촬영에서 임상적 사용이 가능한가?: 기존의 이동형 디지털 X선 장치로 촬영한 흉부 X선 사진과 영상품질 비교)

  • Sang-Ji Kim;Hwan Seok Yong;Eun-Young Kang;Zepa Yang;Jung-Youn Kim;Young-Hoon Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.138-146
    • /
    • 2024
  • Purpose To evaluate whether the image quality of chest radiographs obtained using a camera-type portable X-ray device is appropriate for clinical practice by comparing them with traditional mobile digital X-ray devices. Materials and Methods Eighty-six patients who visited our emergency department and underwent endotracheal intubation, central venous catheterization, or nasogastric tube insertion were included in the study. Two radiologists scored images captured with traditional mobile devices before insertion and those captured with camera-type devices after insertion. Identification of the inserted instruments was evaluated on a 5-point scale, and the overall image quality was evaluated on a total of 20 points scale. Results The identification score of the instruments was 4.67 ± 0.71. The overall image quality score was 19.70 ± 0.72 and 15.02 ± 3.31 (p < 0.001) for the mobile and camera-type devices, respectively. The scores of the camera-type device were significantly lower than those of the mobile device in terms of the detailed items of respiratory motion artifacts, trachea and bronchus, pulmonary vessels, posterior cardiac blood vessels, thoracic intervertebral disc space, subdiaphragmatic vessels, and diaphragm (p = 0.013 for the item of diaphragm, p < 0.001 for the other detailed items). Conclusion Although caution is required for general diagnostic purposes as image quality degrades, a camera-type device can be used to evaluate the inserted instruments in chest radiographs.