• Title/Summary/Keyword: 흉부 X-선

Search Result 223, Processing Time 0.023 seconds

The Manufacture of Digital X-ray Devices and Implementation of Image Processing Algorithm (디지털 X-ray 장치 제작 및 영상 처리 알고리즘 구현)

  • Kim, So-young;Park, Seung-woo;Lee, Dong-hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.4
    • /
    • pp.195-201
    • /
    • 2020
  • This study studied scoliosis, one of the most common modern diseases caused by lifestyle patterns of office workers sitting in front of computers all day and modern people who use smart phones frequently. Scoliosis is a typical complication that takes more than 80% of the nation's total population at least once. X-ray are used to test for these complications. X-ray, a non-destructive testing method that allows scoliosis to be easily performed and filmed in various areas such as the chest, abdomen and bone without contrast agents or other instruments. We uses NI DAQ to miniaturize digital X-ray imaging devices and image intensifier in self-shielding housing with Vision Assistant for drawing lines to the top and the bottom of the spine to acquire angles, i.e. curvature in real-time. In this way, the research was conducted to see scoliosis patients and their condition easily and to help rapid treatment for solving the problem of posture correction in modern people.

Development of the Upper Wear Fixation Device for Chest AP X-ray Imaging on the Emergency Stretcher Bed (응급실 침대 위 흉부전후방향 엑스선 검사를 위한 상의고정장치 개발)

  • Lim, Woo-Taek;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.205-211
    • /
    • 2022
  • This study aimed to provide basic data for 3D printing in the medical health field by developing upper wear fixation device (UWFD), an auxiliary device for shortening chest AP examination time on emergency room beds and non-contact with patients. The standard of hooks was modeled according to the bed frame using the Autodesk Fusion 360. It was printed with Form2 (Formlabs, Somerville, MA, USA), as SLA (stereo lithography apparatus) method, and was washed and hardened using Form Wash and Form Cure. The completed UWFD conducted an online survey on 4 items of stability, convenience, availability, preference and general characteristics. The total stability average was 3.93±0.80, the total convenience average was 3.93±0.68, the total availability average was 4.01±0.89, and the total preference average was 3.80±1.08. This study was significant in suggesting improvements in the general X-ray examination process in the emergency room by designing and making aids to easily fixing the patient's top to the frame of the emergency bed while meeting promptness and non-contact with the patient.

The efficacy of computerized tomographic scan for chest trauma (흉부외상 환자에 대한 전산화 단층촬영의 효용성)

  • Roh, Hwan-Kyu;Choi, Ho;Kim, Young-Jin;Kim, Jung-Tae;Soh, Dong-Moon;Ryu, Han-Young;Lee, Cheol-Joo
    • Journal of Chest Surgery
    • /
    • v.31 no.3
    • /
    • pp.298-303
    • /
    • 1998
  • Computerized tomography(CT) is an effective technique in the initial evaluation of the abdomen and head following blunt trauma. To evaluate the efficacy of CT of the thorax, a retrospective study comparing early thoracic CT scanning with initial chest roentgenogram (CXR) was carried out on 134 patients with blunt trauma on the chest. Among 134 patients, 45 patients had normal initial chest roentgenogram and 24 patients showed normal CT findings. Sensitivities of diagnosing pneumothorax and pleural effusion by CXR were low (46.2 and 62.9% respectively), whereas 71.4%(45/63) of patients had thoracostomy only by CXR. Although sometimes abused, CT of the thorax is effective in the initial diagnosis.

  • PDF

Restoration of Chest X-ray Image Using Dual Projection Filter (이중 프로젝션 필터를 이용한 흉부 X-선 영상의 복원)

  • 이태수;민병구
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.1
    • /
    • pp.25-32
    • /
    • 1992
  • A new restoration method of chest X -ray image (dual project filter) was proposed to improve SNR(signal to noise ratio) characteristics. In this method, a priori Information of system and anatomical structure and statistics of projected object are used in the design of filter. Dual projection filter varies its parameters, adapting to the local regions of chest(lung region, mediasternum, subdiaphragm) and the structure of chest (bone, tissue, blood vessel, bronchia). The performance of Dual Projection Filter was 0.1-0.2dB better than Dual Sensor Wiener Filter, which was used for initial estimate of Dual Porjection Filter.

  • PDF

A CASE OF PLASTIC BRONCHITIS (Plastic Bronchitis 1례)

  • 김종훈;김중강
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1987.05a
    • /
    • pp.18.2-18
    • /
    • 1987
  • Plastic bronchitis는 길고, 분지된 기관지원주(bronchial cast)의 형성과 기관지원주의 현미경 검사상, 염증세포를 포함하고 있는 농후한 점액의 층상 구조를 특징으로 하는 질환으로, 과거에는 fibrinous bronchitis, pseudomembranous bronchitis 그리고 Hoffman's bronchitis로 불려졌으며, 소아와 성인에서 발생하는 드문 질환으로 알려져 있다. 본 교실에서는 갑작스러운 발열, 기침 및 호흡 곤란을 동반하고, 흉부 단순 X-선 검사상 좌측 흉부에 무기폐 소견을 보인 19개월 남아에서, 기관지경 검사를 시행하여 제거한 조직의 육안 및 광학현미경 검사상 plastic bronchitis를 의심할 수 있는 1례를 경험하였기에 보고하는 바이다.

  • PDF

The Effect of X-ray Tube Potential on the Image Quality of Digital Chest Radiography with an Amorphus Silicon Flat Panel Detectors (비정질 평판형 측정기를 이용한 디지털 흉부 방사선 영상에서의 효과적인 관전압 선택)

  • Kim, Jung-Min;Im, Eun-Kyung
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.273-277
    • /
    • 2005
  • The rapid development in digital acquisition technology in radiography has not been accompanied by information regarding optimum radiolographic technique for use with an amorphus silicon flat panel detector. The purpose of our study was to compared image quality and radiation dose of an amorphus silicon flat panel detectors for digital chest radiography. All examinations were performed by using an amorphus silicon flat panel detector. Chest radiographs of an chest phantom were obtained with peak kilovoltage values of $60{\sim}150kVp$. Published data on the effect of x-ray beam energy on image quality and patient dose when using an amorphus silicon flat panel detector. It is important that radiographers are aware of optimum kVp selection for an amorphus silicon flat panel detector system, particularly for the commonly performed chest examination.

  • PDF

Surgical Treatment of Pulmonary Actinomycosis Mimicking Pulmonary tuberculosis (폐결핵으로 오인된 폐방선균증의 수술적 치험 1례)

  • 백효채;이진구;강정한;정경영;구자승
    • Journal of Chest Surgery
    • /
    • v.35 no.4
    • /
    • pp.315-317
    • /
    • 2002
  • Pulmonary actinomycosis is a rare disease entity to undergo thoracic surgery. We experienced a 49-year-old man with pulmonary actinomycosis who was admitted due to recurrent hemoptysis. Prior to admission, he was diagnosed as pulmonary tuberculosis on the basis of his clinical manifestations and chest radiological findings. The plain chest x-ray and chest computed tomography(CT) showed a cavitary lesion in left upper lobe and was given anti-tuberculous medication, but the x-ray revealed no imprcovement. He underwent left upper lobe lobectomy with segmentectomy of lower lobe and the surgical specimen showed no evidence of mycobacterial infection, but revealed sulfur granules which is a typical pathological finding of actinomycosis. He was discharged uneventfully and is scheduled to receive 6 months of antibiotic treatment.

Ensemble Knowledge Distillation for Classification of 14 Thorax Diseases using Chest X-ray Images (흉부 X-선 영상을 이용한 14 가지 흉부 질환 분류를 위한 Ensemble Knowledge Distillation)

  • Ho, Thi Kieu Khanh;Jeon, Younghoon;Gwak, Jeonghwan
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2021.07a
    • /
    • pp.313-315
    • /
    • 2021
  • Timely and accurate diagnosis of lung diseases using Chest X-ray images has been gained much attention from the computer vision and medical imaging communities. Although previous studies have presented the capability of deep convolutional neural networks by achieving competitive binary classification results, their models were seemingly unreliable to effectively distinguish multiple disease groups using a large number of x-ray images. In this paper, we aim to build an advanced approach, so-called Ensemble Knowledge Distillation (EKD), to significantly boost the classification accuracies, compared to traditional KD methods by distilling knowledge from a cumbersome teacher model into an ensemble of lightweight student models with parallel branches trained with ground truth labels. Therefore, learning features at different branches of the student models could enable the network to learn diverse patterns and improve the qualify of final predictions through an ensemble learning solution. Although we observed that experiments on the well-established ChestX-ray14 dataset showed the classification improvements of traditional KD compared to the base transfer learning approach, the EKD performance would be expected to potentially enhance classification accuracy and model generalization, especially in situations of the imbalanced dataset and the interdependency of 14 weakly annotated thorax diseases.

  • PDF

Scattered X-ray Correction Using a Modified Auto-Encoder (수정된 구조의 AE 모델을 이용한 X-ray 산란선 보정 기법)

  • Seo, Hyogyeong;Jeong, Jihoon;Lee, Donggyu;Han, Seunghwa;Kim, Hojoon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.11a
    • /
    • pp.708-710
    • /
    • 2021
  • 본 논문에서는 X-ray 진단에서 산란선으로 인한 영상의 왜곡을 보정하는 방법으로서 수정된 구조의 AE(Auto-Encoder) 모델에 기반한 방법론을 제안한다. 기존 AE 모델의 계층에 따라 특징지도의 크기가 축소되고 팽창되는 과정에서 영상 복원에 필요한 정보가 소실될 가능성을 보완하기 위하여 동일 레벨 계층 간에 스킵 연결을 추가하였다. 또한 X-ray 영상에서 피사체 세부 부위의 두께와 밀도에 따라 산란선의 영향이 서로 다른 형태로 나타난다는 특성을 학습 과정에 효과적으로 반영하기 위하여 어텐션 모듈을 추가한 네트워크 구조를 도입하였다. 총 80 쌍의 흉부 X-ray 영상 데이터에 대하여 기존의 AE 모델을 사용한 방법 및 U-Net 과 FFA-Net 모델을 사용한 영상 복원 기법의 실험 결과를 상호 비교함으로써 제안된 방법의 타당성을 평가하였다.

A Study on the Analysis of Virus Barrier Materials in a Chest X-ray Laboratory to Respiratory and Droplet Infections Only Patients (호흡기 및 비말감염 환자 전용 흉부 X-선 검사실의 바이러스 차단제 분석에 관한 연구)

  • Kim, Hyeon-Ju;Lee, Jun-Ho;Choi, Kwan-Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.169-175
    • /
    • 2022
  • In this study, envisioned a laboratory equipped with virus blocking equipment for chest X-ray examinations of respiratory or droplet-transmitted virus-infected patients, and the material with the least deterioration in X-ray output and image quality among the proven blocking materials that block viruses in the design process. and experimented to find the thickness. As a result, when 1 cm of acrylic was applied, the X-ray output was reduced by only about 3.27 % compared to the absence of the barrier material, the SNR was 40.7 and CNR was 30.9, which was the best. The SSIM index result was analyzed as 0.891, which was analyzed to be implemented as the most similar image compared to the original image. The barrier material applied in the research method was objective in that it used a product approved by the Ministry of Food and Drug Safety. the results of this study are expected to provide useful information when installing X-ray examination facilities for the diagnosis and treatment of respiratory-related virus-infected patients in the future.