• Title/Summary/Keyword: 흉부 후.전 방향 검사

Search Result 12, Processing Time 0.014 seconds

Human Lung Cancer Cell Xenografts Implanted under the Capsule of Kidney, Spleen and Liver (폐암 세포주를 사용한 신, 비장 및 간 피막하 분식법의 비교)

  • 김수현;김종인;이해영;조봉균;박성달;김송명
    • Journal of Chest Surgery
    • /
    • v.36 no.10
    • /
    • pp.711-720
    • /
    • 2003
  • Bakground : Complete resection by the surgery has been selected as the treatment of choice in lung cancer patients, but in cases of recurrence after excision or inoperable cases, the importance of anticancer chemotherapy has been emphasized. If one can select a set of the sensitive chemotherapeutic agents before anticancer chemotherapy, it will give more favourable results. Subrenal capsular assay has been recognized as a useful in-vivo chemosensitivity test of thoracic and abdominal tumors and it can be done in a short time for a rapid interpretation of tumor responsiveness to anticancer chemotherapeutic drugs. It has been reported that various kinds of cancer cells can be implantable to the kidney, but so far there is no comparative study of xenogeneic cell implantation on liver, spleen and kidney. The author implanted the human lung cancer cells under the capsule of S.D rat's liver, spleen and kidney respectively and compared the pattern of growth and histology. Material and Method: After incubation of human lung cancer cell line (SW-900 G IV) in RPMI 1640 (Leibovitz L-15 medium) culture media, 3${\times}$3${\times}$3 mm size fibrin clots which contain 108 cancer cells were made. Thereafter the fibrin clots were implanted at subcapsule area of liver, spleen and kidney of S.D. female rat. For immune suppression, cyclosporin-A (80 mg/Kg) was injected subcutaneously daily from post-implantation first day to sixth day. The body weight was measured at pre and post implantation periods. The growth pattern and the size of tumor mass were observed and the pathologic examination and serum tumor marker tests were performed. Result: Body weight increased in both of control and experimental groups. Serum Cyfra 21-1 was not detected. Serum levels of CEA and NSE revealed no significant change. The SCC-Ag increased significantly in implanted group. The growth rate of human lung cancer cells which was implanted on spleen was higher than on liver or kidney. The surface area, thickness, and volume of tumor mass were predominant at spleen. The success rates of implantation were 80% on kidney, 76.7% on spleen and 43.3% on liver. Pathologic examination of implanted tumors showed characteristic findings according to different organs. Tumors that were implanted on kidney grew in a round shape, small and regular pattern. In the spleen, tumors grew well and microscopic neovascularization and tumor thrombi were also found, but the growth pattern was irregular representing frequent daughter mass. Human lung cancer cells that were implanted in the liver, invaded to the liver parenchyme, and had low success rate of implantation. Microscopically, coagulation necrosis and myxoid fibrous lesion were observed. Conclusion: The success rate of implantation was highest in the kidney. And the mass revealed regular growth that could be measured easily. The SCC-Ag was presented earlier than CEA or Cyfra21-1. The Cyfra21-1 was not detected at early time after implantation. The best model for tumor implantation experiment for chemosensitivity test was subrenal capsular analysis than liver and spleen and the useful serum tumor marker in early period of implantation was the SCC-Ag.

Adequacy of Source to Image Receptor Distance with Chest Postero-Anterior Projection in Digital Radiology System (디지털방사선 환경에서 흉부 후-전 방향 검사 시 초점과 영상수용체간 거리의 적절성)

  • Joo, Young-Cheol;Lim, Cheong-Hwan;You, In-Gyu;Jung, Hong-Ryang;Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.135-142
    • /
    • 2016
  • The purpose of this study is to evaluate propriety of using SID 180cm at Chest PA examination and to find effect of geometrical cause to the image. XGEO-GC80, INNOVISION-SH, CXDI-40EG detector and a chest phantom designed self-production was used for this study. Images were acquired at SID 180cm with changing the factor OID as 0, 75 and 83mm and were analyzed by Centricity Radiography RA1000 PACS system. Statistical program was used the SPSS (Version 22.0, SPSS, Chicago, IL, USA), p-value(under 0.05) was considered to be statistically significant. In OID 0 mm was enlarged about 2.7~3.5 mm than the actual degree of the HS, BS of phantom in all equipments. Compared with the calculated magnification has been expanded 1.6~2.8% when viewed. The OID 75 mm with OID 83 mm was extended from the CS and BS 6~8 mm range. Compared to the calculated values, the measured values are expanded from 6.1 to 7.9%. CS and BS according to the OID change showed a statistically significant difference (p<0.05) among each group, the post-analysis only OID 0 mm group appeared as an independent group, 75 mm and 83 mm are separated in the same group It was. But had no statistically significant difference could change depending on the OID (p>0.05), post-mortem analysis showed, both in the same group. Heart sizes appears larger than actual size 6~8 mm at chest PA examination which is enlarged 6.1~7.9% more than the actual theoretical value. We can find magnification of the image because of the increase of the OID due to technical limitations between cover of standing detector and the image plate. so we suggest to have occurred between them when considering the need to adjust the equipment installed by the SID to match the characteristics of the equipment.