• Title/Summary/Keyword: 흉부 손상

Search Result 475, Processing Time 0.035 seconds

Comparison of Continuous Mechanical Ventilation and Internal Fixation in Flail Chest Injuries (불안정 흉벽손상에서 지속적 인공호흡법과 내적 늑골고정술의 비교)

  • Gang, Chang-Hui;Jang, In-Seong
    • Journal of Chest Surgery
    • /
    • v.30 no.4
    • /
    • pp.413-418
    • /
    • 1997
  • From January, 1992 to June, 1996, )7 patients with flail chest were treated at Sonnchunhyang university hospital. 15 patients were managed by internal fixation of fractured ribs, whereas the remaining 22 patients were managed by endotracheal intubation and intermittent positive-pressure ventilation alone. There were no difference between two groups in age, sex, the severity of injury to the chest wall and the nature of associated injuries. Average dur'Btion of assisted ventilation was 5.7 $\pm$ 1.7 days in the patients treated by internal fixation versus 8.7 $\pm$ 3.3 days In the patients treated by continuous me hanical ventilation. Average stay in the intensive care unit was 8.3 $\pm$ 3.9 days for the patients treated by internal fixation, whereas it was $13.2\pm4.1$ days in the group treated by continuous mechanical ventilation alone. In the group treated by internal fixation, complications were 3 atelectases(20.0%), 1 pneumonia(6.7%), 2 operative wound problems(12.3%) and 1 barotrauma(6.7%). In the other group, 7 atelectases(31.8%), 4 pneumonitis(18.2%), 2 empyemas(9.1%) and 3 barotraumas(1).6%). The mortality rate was 13.3%(2/15) in the surgically treated patients, whereas it was 22.7%(5122) in the other group. The treatment of flail chest by internal fixation resulted in speedy recovery, decreased complications and mortalities, and better ultimatc cosmetic and functional results.

  • PDF

Vein Injury and Wound Complications Associated with Techniques of Saphenous Vein Harvest (복재정맥 수확방법에 따른 이식편의 손상과 수술창의 합병증의 빈도)

  • 최종범;박권재;양현웅;이삼윤;최순호
    • Journal of Chest Surgery
    • /
    • v.36 no.7
    • /
    • pp.504-509
    • /
    • 2003
  • Although arterial grafts are widely used due to the advantage of long-term patency in coronary bypass surgery, greater saphenous vein is still an important additional conduit. It was reported that preservation of the adventitia of vein graft and the adjacent tissues may bring the improved long-term graft patency. The aim of this study is to look for a harvest technique that can reduce vein injury and wound complications. Material and Method: In thirty-four patients that vein grafts were used for coronary bypass surgery, 50 harvest sites were included for the study. In 25 harvest sites in calf below knee (group 1), vein was exposed through a long incision and then clearly dissected from the adjacent tissue. Ten endoscopic vein harvests were performed in the thighs (group 2). Fifteen other vein grafts that were bluntly dissected were harvested from the thighs through three separate incisions (group 3). Result: Vein harvest time was longest in endoscopic harvest group (44.7$\pm$9.8 minutes) and shortest in group 3 (24.2$\pm$5.9 minutes) (p=0.000). Most avulsion injuries of vein branches happened in the endoscopic group. Sequential grafting numbers per vein were 1.72$\pm$0.98 with thigh vein graft and 1.16$\pm$0.37 with calf vein (p=0.02). Swelling of foot and/or leg, which was the most common wound complication after vein harvest, was most commonly presented in group 1 (20/25 sites; p=0.000). Tingling, the most common neurologic complication, was also most prevalent in group 1 (7/25 sites; p=0.013). The risk factor of the wound complication was vein harvest from calf, and the vein harvest technique was not a risk for wound complication. Conclusion: Vein harvest technique through three separate incisions from thigh presented shorter harvest time and less vein injury and wound complication compared with the endoscopic harvest technique from thigh or the harvest through a long incision from calf.

Scintigraphic Evaluation of Inhalation Injury in Fire Victims (화재사고시 흡입에 의한 기도손상의 핵의학적 평가)

  • Chun, Kyung-Ah;Cho, Ihn-Ho;Won, Gyu-Jang;Lee, Hyung-Woo;Shin, Kyung-Chul;Jeong, Jin-Hong;Lee, Gwan-Ho
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.28-32
    • /
    • 2006
  • Purpose: Conventional chest X-ray and pulmonary function test cannot sensitively detect inhalation injury. Bronchoscopy is known to be the gold standard but it is invasive method. We evaluated whether lung inhalation/perfusion scans can sensitively detect inhalation injury of fire victims. Materials and Methods: Nineteen patients (male 9, female 10, mean age 31.6 yr) of fire victims were enrolled in this study. Inhalation lung scan was performed 2 days later after inhalation injury with $^{99m}Tc$-technegas. Perfusion lung scan was performed 4 days later with $^{99m}Tc$- MAA (macroaggregated albumin). Follow up lung scans were performed 16 and 18 days later for each. Chest X-ray was performed in all patients and bronchoscopy was performed in 17 of 19 patients at the same period. Pulmonary function test was performed in 9 patients. Results: Four of 19 patients showed inhalation and perfusion defects and one showed inhalation defect but, normal perfusion scan findings. These five patients with abnormal scan findings showed abnormal bronchoscopic findings and severe respiratory symptoms. On chest X-ray, 2 of them had pulmonary tuberculosis and one of them showed pulmonary congestion. FEV1 /FVC was abnormal in 3 patients. On the follow up scan, all patients with abnormal initial scan findings showed improved findings and they had improved clinical state. Conclusion: Inhalation/perfusion lung scans can detect inhalation burn injury noninvasively in early stage and may be useful in therapeutic decision making and follow up of patients.

Successful 20 hours Canine Allograft Preservation with new Solution Containing Triiodothyronine - Development of new lung preservation solution II - (삼요드티로닌을 포함한 폐보존액을 이용한 20시간 폐보존 - 새로운 폐 보존액의 개발 II -)

  • 성숙환;김영태;김주현
    • Journal of Chest Surgery
    • /
    • v.32 no.5
    • /
    • pp.413-421
    • /
    • 1999
  • Background: Ischemia reperfusion injury is known to contribute to the major causes of the early graft failure in lung transplantation. Triiodothyronine (T3) has been suggested to ameliorate ischemia reperfusion injury from both in vivo and in vitro experiments of various organs. Prospecting its beneficial effect for pulmonary allograft preservation, we made a new solution by adding T3 into the extracellular type dextran solution. Material and Method: Twelve adult mongrel dogs underwent left lung allotransplantation. Six donor dogs were flushed with the new solution(Group 1, n=6), and the remaining six were flushed with Euro-Collins solution to serve as controls(Group 2, n=6). Allografts were stored in each preservation solution for 20 hours at 4$^{\circ}C$. Left single lung transplantations were performed. The right pulmonary artery and the right main bronchus were clamped at 15 minutes after the reperfusion and maintained throughout the experiment to evaluate the transplanted left lung function. Result: Arterial carbon dioxide tension was better in group 1 than in group 2 throughout the experiment period and the difference was statistically significant at 2 hours after reperfusion(28.0${\pm}$3.0 mmHg and 53.1${\pm}$17.4 mmHg, p<0.05). The differences of arterial oxygen partial pressure, peak airway pressure and pulmonary vascular resistance showed no statistical significance. The malondialdehyde(MDA) level, measured from tissue obtained at 120 minutes after reperfusion showed no statistically significant difference. The tissue wet/dry ratio of group 1(649${\pm}$27 %) was significantly lower than that of group 2(686${\pm}$71 %, p<0.05). The microscopic examination revealed varying degrees of injury represented mainly by findings such as perivascular neutrophil infiltration, capillary hemorrhage and interstitial congestion. These findings were less severe in group 1 than those in group 2. Conclusion: The new solution demonstrated superior allograft preservation after 20 hour ischemia compared to Euro-Collins solution in canine single left lung transplantation model, these results suggest that T3 might be a promising agent for pulmonary allograft preservation.

  • PDF

The Effects of Moxifloxacin in Endotoxin-induced Acute Lung Injury (내독소로 유도된 급성폐손상에서 Moxifloxacin의 효과)

  • Baek, Jong Hyun;Lee, Jang Hoon;Lee, Jung Cheul;Lee, Dong Hyup;Moon, Yong Suk;Lee, Young Man
    • Journal of Chest Surgery
    • /
    • v.42 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • Background: The pathophysiology of acute respiratory distress syndrome with sepsis is acute lung injury (ALI) that's' caused by endotoxin (LPS). We evaluate effects of moxifloxacin on LPS-induced ALI in a rat model. Material and Method: The rats were divided into 3 groups as the control group (C), the LPS insult group (L), and the LPS+moxifloxacin treated group (L-M). ALI was induced by endotracheal instillation of E.coli LPS, then moxifloxacin was given in 30 minutes. Five hours later, we checked the lung weight/body weight ratio(the L/BW ratio), the protein & neutrophils in the bronchoalveolar lavage fluid (BALF), the myeloperoxidase (MPO) activity & the malondialdehyde (MDA) content, the expressions of cytosolic and secretory phospholipase $A_2$ (c, $sPLA_2$), and the morphology of the lung with using a light microscope. Result: The L/BW ratio, the protein content and the neutrophil count in the BALF, and the MPO activity and the MDA content in lung were significantly increased in group L compared to group C, and these factors were markedly decreased in group L-M compare to group L. The $cPLA_2$ expression and the $sPLA_2$ expression were increased in group L and the $cPLA_2$ expression was decreased in group L-M. Yet the $sPLA_2$ expression was not changed in group L-M. Morphologically, many inflammatory findings were observed in group L, but not in group L-M. Conclusion: Many of the inflammatory changes of ALI that were caused by LPS insult were ameliorated by moxifloxacin treatment.

Changes of Serum Troponin-T Concentrations in Patients with Open Heart Surgery (개심술환자에 있어 혈청 Troponin-T 농도의 변화에 관한 연구)

  • 박동욱;최석철;김윤규;박종원;조관현
    • Journal of Chest Surgery
    • /
    • v.31 no.2
    • /
    • pp.125-133
    • /
    • 1998
  • This study was designed to identify the efficiency of serum troponin-T(s-TnT) level as a diagnostic indicator for the perioperative myocardial damage with open heart surgery(OHS) and to compare with the conventional myocardial enzyme tests such as isoenzyme fraction of creatine kinase(% CK-MB) and isoenzyme ratio of lactate dehydrogenase(LDH1/LDH2 ratio). The study was performed on 30 adult patients who underwent OHS from Jan. 1996 to June 1996 at Inje University Pusan Paik Hospital, and they were divided into two groups accor- ding to aortic clamping time(ACT) duration : group I(ACT<60 minutes, n=15); group II (ACT>60 minutes, n=15). S-TnT, % CK-MB, and LDH1/LDH2 ratio were measured in serial blood samples from all subjected patients. The results were obtained as follows. 1. In both groups, s-TnT concentrations increased gradually during OHS and elevated significantly at CPB-10(p<0.001). The peak level was noticed at POD 1 in group I(1.10 $\pm$0.19 ng/ml), whereas, at CPB-off in group II(1.88$\pm$0.42 ng/ml). The elevated levels remained until POD 7 in both groups. 2. %CK-MB was risen significantly with the initiation of operations(p<0.001) and the peak levels were noticed at CPB-off in both groups(7.14$\pm$0.86% in group I, 10.69$\pm$1.27% in group II). Thereafter, these levels returned to normal values at POD 3. 3. There were no significant changes in the values of LDH1/LDH2 ratio during and after OHS compared with the control levels(p>0.05). 4. The serial changes of s-TnT were relatively well correlated with those of changes of % CK-MB(r=0.64, p<0.05). 5. The serial s-TnT levels were significantly higher in group II than group I from B-ACR to POD 1(p<0.05), suggesting that duration of aortic clamping time was a major factor concerned with perioperative myocardial injury. In conclusion, measurement of s-TnT is a very useful indicator in assessing the myocardial cell damage and therefore it is expected that serial checking and evaluation of the s-TnT is very available for identification of the perioperative myocardial damage and for postoperative cares in patients with OHS.

  • PDF

The Spectrum of CT Findings of COVID-19 Pneumonia: Acute Alveolar Insult and Organizing Pneumonia as Different Phases of Lung Injury and Repair (COVID-19 폐렴의 다양한 CT 영상 소견: 급성 폐포 손상과 기질화 폐렴)

  • Yun Su Kim;Ung Rae Kang;Young Hwan Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.2
    • /
    • pp.359-370
    • /
    • 2021
  • Purpose To analyze the findings and serial changes in chest CT lesions in 123 symptomatic patients with coronavirus disease 2019 (COVID-19). Materials and Methods From February 19 to April 7, 2020, a total of 123 confirmed COVID-19 patients (male, 44; female, 79; mean age, 59.2 ± 18.6) were enrolled in this retrospective study. A total of 234 CT scans were reviewed for the following patterns: acute alveolar insult (AAI) patterns: ground-glass opacity (GGO), crazy-paving appearance, mixed pattern, and consolidation; organizing pneumonia (OP) patterns: perilobular patterns, band opacity, curvilinear opacity, reversed halo opacity, and small nodular consolidation; resolving patterns: pure GGO, remnant curvilinear, small nodular consolidation, and serial changes of lung abnormalities. We compared the proportions of AAI pattern, OP pattern, or resolving pattern with time progression and analyzed the association between the patterns and disease severity using Pearson chi-square and Fisher's exact test. Results Predominant CT patterns were AAI pattern (87%) in the early hospital period group (0-10 days, after the onset of symptoms), OP pattern (45.7%) in the later hospital period group (after 10 days), and resolving pattern in discharge and follow-up group (47.2% and 84.8%, respectively). The difference in the proportions of predominant CT patterns with time progression was statistically significant (p < 0.001, Pearson's chi-square test). No statistically significant association was observed between the patterns and disease severity (p = 0.055, Fisher's exact test). No fibrous changes in the lesions were observed on follow-up CT scans. Conclusion The serial CT scans of COVID-19 patients showed the spectrum of COVID pneumonia CT manifestations as different phases of lung injury and repair.

The Effect and Safety of Alveolar Recruitment Maneuver using Pressure-Controlled Ventilation in Acute Lung Injury and Acute Respiratory Distress Syndrome (급성폐손상과 급성호흡곤란증후군 환자에서 압력조절환기법을 이용한 폐포모집술의 효과와 안정성)

  • Chung, Kyung Soo;Park, Byung Hoon;Shin, Sang Yun;Jeon, Han Ho;Park, Seon Cheol;Kang, Shin Myung;Park, Moo Suk;Han, Chang Hoon;Kim, Chong Ju;Lee, Sun Min;Kim, Se Kyu;Chang, Joon;Kim, Sung Kyu;Kim, Young Sam
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.5
    • /
    • pp.423-429
    • /
    • 2007
  • Background: Alveolar recruitment (RM) is one of the primary goals of respiratory care for an acute lung injury (ALI) and acute respiratory distress syndrome (ARDS). The purposes of alveolar recruitment are an improvement in pulmonary gas exchange and the protection of atelectrauma. This study examined the effect and safety of the alveolar RM using pressure control ventilation (PCV) in early ALI and ARDS patients. Methods: Sixteen patients with early ALI and ARDS who underwent alveolar RM using PCV were enrolled in this study. The patients data were recorded at the baseline, and 20 minutes, and 60 minutes after alveolar RM, and on the next day after the maneuver. Alveolar RM was performed with an inspiratory pressure of $30cmH_2O$ and a PEEP of $20cmH_2O$ in a 2-minute PCV mode. The venous $O_2$ saturation, central venous pressure, blood pressure, pulse rate, $PaO_2/FiO_2$ ratio, PEEP, and chest X-ray findings were obtained before and after alveolar RM. Results: Of the 16 patients, 3 had extra-pulmonary ALI/ARDS and the remaining 13 had pulmonary ALI/ARDS. The mean PEEP was 11.3 mmHg, and the mean $PaO_2/FiO_2$ ratio was 130.3 before RM. The $PaO_2/FiO_2$ ratio increased by 45% after alveolar RM. The $PaO_2/FiO_2$ ratio reached a peak 60 minutes after alveolar RM. The Pa$CO_2$ increased by 51.9 mmHg after alveolar RM. The mean blood pressure was not affected by alveolar RM. There were no complications due to pressure injuries such as a pneumothorax, pneumomediastinum, and subcutaneous emphysema. Conclusion: In this study, alveolar RM using PCV improved the level of oxygenation in patients with an acute lung injury and acute respiratory distress syndrome. Moreover, there were no significant complications due to hemodynamic changes and pressure injuries. Therefore, alveolar RM using PCV can be applied easily and safely in clinical practice with lung protective strategy in early ALI and ARDS patients.

Lung Preservation Study for Above 20 Hours of LPDG Solution in Canine Lung Allotransplactation (폐이식 실험견에서 LPDG용액을 이용한 20시간 이상 폐보존효과 관찰)

  • Park, Chang-Gwon;Gwon, Geon-Yeong;Yu, Yeong-Seon
    • Journal of Chest Surgery
    • /
    • v.30 no.10
    • /
    • pp.949-960
    • /
    • 1997
  • Background. Limited ischemic tolerance of the lung has remained one of the factors that limits the expansion of pulmonary transplantation as a treatment for end-stage pulmonary disease. Numerous studies on safe long term preservation for lung transplantation has been performed for the purpose of developing ideal preservation solution with extracellular type or intracellular type solutions. In this. study, we examined the efficacy of L DG solution in lung preservation longer than 20 hours by comparison with modified Euro-Collins solution. Iwethods. Thirty-(our adult mongrel dogs were divided into two groups. Donor lungs were flushed with LPDG solution(n=9) or modified Euro-Collins(MEC) solution(n=8) and stored for 24 hours at 1$0^{\circ}C$. All donor lungs were perfused through the pulmonary arteries with solutions containing prostaglandin El and verapamil. Left canine lung allotransplantations wereperformed. Assessment(hemodynamic indices and arterial blood gas analysis) of left implanted lung was made by occluding the right pulmonary artery for ten minutes using pulmonary artery Cuff. Assessment was repeated at the interval of 30 minutes, one hour, and two hours later after reperfusion and then chest X-ray, computed tomogram and lung perfusion scan were obtained. In survival dogs follow-up studies were done with assessment with chest X-ray, computed tomogram of the chest and lung perfusion scan on 7th day postoperatively. After preservation above 20 hours, pathological examinations for ultrastructural findings on right lung were performed in each group. Results. With respect to arterial oxygen tension, LPDG group was superior to MEC but there was no statistical significance for 2 hours after reperfusion. Mean pulmonary artery pressure was less increased(p < 0.05) and cardiac output higher(p <0.05) than MEC group until 2 hours after reperfusion. After 2 hours of reperfusion, both groups showed transplanted lung function deteriorated gradually. Perfusion scan of the transplanted lung in LPDG group showed better perfusion rate in immediate post-reperfusion, 3 days and 7 days later respectively but there was no statistical significance and corelation with PaO2 and computed tomoRravhic views. In scanning electron microscopy of pulmonary artery after preservation, LPDG group relatively shows less irregular protrusion of the inner surface of endothelial cell of poulmonary artery than MEC group. Conclusions, e concluded that LPDG solution can offer safe lung preservation above 20 hours with adequate immunosuppressive therapy and prevention of the infection.

  • PDF

Clinical Application of Stent-graft in Thoracic Aortic Diseases (흉부 대동맥 질환에서 스텐트-그라프트의 임상적 적용)

  • Kim, Kyung-Hwan;Lee, Cheul;Chang, Ji-Min;Chung, Jin-Wook;Ahn, Hyuk;Park, Jae-Hyung
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.698-703
    • /
    • 2001
  • Background: Endovascular stent-graft insertion in aortic diseases is now generally accepted as an attractive alternative treatment modality. We reviewed our clinical experiences of endovascular stent-graft insertion in thoracic aorta. Material and Method: Since 1995, we performed 8 cases of endovasclar stent-graft insertion. Preoperative diagnoses were aortic aneurysms in 4, traumatic aortic ruptures in 3, and ruptured aortic pseudoaneurysm in 1. All procedures were performed in angiography room with the guidance of fluoroscopy. The stent-graft device is a custom-made 0.35mm thickness Z-shaped stainless steel wires, intertwined with each other using polypropylene suture ligation. It is covered with expanded Dacron vascular graft. Result: All procedures were performed successfully. Follow-up studies revealed 2 minimal perigraft leakages. There was no significant leakage or graft migration. 2 patients expired due to multiple organ failure and fungal sepsis. Other survivors(6) are doing well. Conclusion: Endovascular stent-graft insertion is relatively saft and effective treatment modality in the managment of various types of aortic diseases. In may be an effective alternative in aortic diseases of great surgical risk.

  • PDF