• Title/Summary/Keyword: 휘도 차

Search Result 166, Processing Time 0.024 seconds

Investigation of SO2 Effect on TOMS O3 Retrieval from OMI Measurement in China (OMI 위성센서를 이용한 중국 지역에서 TOMS 오존 산출에 대한 이산화황의 영향 조사 연구)

  • Choi, Wonei;Hong, Hyunkee;Kim, Daewon;Ryu, Jae-Yong;Lee, Hanlim
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.6
    • /
    • pp.629-637
    • /
    • 2016
  • In this present study, we identified the $SO_2$ effect on $O_3$ retrieval from the Ozone Monitoring Instrument (OMI) measurement over Chinese Industrial region from 2005 through 2007. The Planetary boundary layer (PBL) $SO_2$ data measured by OMI sensor is used in this present study. OMI-Total Ozone Mapping Spectrometer (TOMS) total $O_3$ is compared with OMI-Differential Optical Absorption Spectrometer (DOAS) total $O_3$ in various $SO_2$ condition in PBL. The difference between OMI-TOMS and OMI-DOAS total $O_3$ (T-D) shows dependency on $SO_2$ (R (Correlation coefficient) = 0.36). Since aerosol has been reported to cause uncertainty of both OMI-TOMS and OMI-DOAS total $O_3$ retrieval, the aerosol effect on relationship between PBL $SO_2$ and T-D is investigated with changing Aerosol Optical Depth (AOD). There is negligible aerosol effect on the relationship showing similar slope ($1.83{\leq}slope{\leq}2.36$) between PBL $SO_2$ and T-D in various AOD conditions. We also found that the rate of change in T-D per 1.0 DU change in PBL, middle troposphere (TRM), and upper troposphere and stratosphere (STL) are 1.6 DU, 3.9 DU and 4.9 DU, respectively. It shows that the altitude where $SO_2$ exist can affect the value of T-D, which could be due to reduced absolute radiance sensitivity in the boundary layer at 317.5 nm which is used to retrieve OMI-TOMS ozone in boundary layer.

The Effect of Sympathectomy on Bone: -Evaluation with Quantitative Bone Scintigraphy- (흰쥐에서 교감신경절제술이 골에 미치는 영향 : -정량적 골스캔을 이용한 평가-)

  • Kim, Hak-Hee;Yang, Woo-Jin;Lee, Seong-Yong;Chung, Soo-Kyo;Park, Jang-Sang;Yim, Jung-Ik;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.85-88
    • /
    • 1994
  • 근래 골조직에 있어서 자율신경의 기능에 대하여 많은 연구가 이루어지고 있으며, 골내의 자율신경의 해부학적 분포는 많이 알려져 있다. 그러나 임상적으로 반사적 교감신경 이상이나 레이노드 현상등과 같은 교감신경의 기능이상증에서나, 버거씨병 등의 치료 목적으로 시행되고 있는 교감신경 절제술 후, 자율신경기능의 변화가 사지골의 혈류나 골대사에 미치는 영향에 대하여는 아직도 논란의 여지가 있다. 저자들은 교감신경절제술 후 시간 경과에 따른 골에 미치는 영향을 알아보기 위하여 흰쥐에서 골대사와 혈류상태를 비교적 충실히 반영하는 정량적 골스캔을 시행하였다. 체중 $300{\sim}400g$의 수컷 흰쥐 10마리에서 복강을 통한 편측 요추부 교감신경절제술을 시행하였고, 수술 전과 후 1일, 3일, 1주, 2주, 3주, 4주에 양측 하지에서 각각 골스캔을 시행하고 교감신경 절제측 하지와 정상 하지에 대칭적으로 관심구역을 정하여 양측의 골스캔상 섭취계수를 비교하였다. 측정부위는 각 하지의 대퇴골간, 경골간 및 중족골로 하였다. 교감신경 절제술을 시행한 하지에서는 골스캔 소견상 수술 후 1일 또는 3일부터 동위원소 집적이 유의하게 증가되었으며 원위부로 갈수록 더욱 증가되었다. 그러나 3주 이후에는 정상측 수준으로 환원되었다. 교감신경절제술 후 골스캔상 동위원소집적이 증가되는 것은 골자체의 혈류가 증가되기 때문이며 이차적으로 골의 흡수를 유발하여 골밀도가 감소하는 것으로 생각되는데 이러한 변화는 시술 후 1일 째부터 관찰되어 사지골이 교감신경 절제에 매우 민감하게 반응하는 것을 알 수 있었다.9m}Tc$-MAA를 이용한 간 동맥 혈류 검사는 간암에서 색전술의 효과를 정확히 평가할 수 있는 유용한 검사법으로 이용될 수 있으리라 생각한다. 활성화 과정을 알아볼 수 있었으며 위상영상히스토그램을 통하여 이를 정량화하여 심실내 전기적 활성의 비동시성 여부를 추적관찰 할 수 있는 비관혈적검사임을 확인하였다.며, 3. $^{99m}Tc$으로 표지된 avidin과 streptavidin은 먼저 간으로 흡수된 후 대사된 다음 신장으로 배설된다는 사실을 알았다.damole에 의한 부작용은 흉통, 두통, 복통 등의 순이었고 전예에서 호전되었으며 생명에 위험을 초래할 수 있는 정도의 심장마비나 심부정맥은 한 예에서도 없었다. 결론적으로 dipyridamole은 약물부하 심근 SPECT 검사에 안전하게 사용할 수 있는 약물로 사료된다. 미소핵 빈도수가 증가하는 경향을 보였으나, 각 군간에 통계학적으로 유의한 차이는 없었다(p>0.05). 결론 : 임상적으로 치료를 중단하게 되는 1000mCi/60 Kg(16.67 mCi/Kg)를 투여한 군에서도 생쥐 골수내 미소핵이 발현되지 않는 것으로 보아, 방사성옥소는 비교적 안심하고 치료에 사용할 수 있는 제제로 사료되었다.반드시 비례하지만은 않아서 시간경과에 따른 추후 검사가 필요하리라 생각된다. 또한 방광요관역류가 있는 환아에서 DMSA 섭취율로 신기능을 평가할 때, 특히 영유아에서 연령에 따른 고려가 있어야 할 것으로 보인다.었다. 4) $^{99m}Tc-DISIDA$ hepatobiliary scintigram 음성율을

  • PDF

Sulfur Isotope Composition and Isotopic Temperatures of the Shinyemi Lead and Zinc Ore Deposits, Western Taebaegsan Metallogenic Belt, Korea (신예미광상산(新禮美鑛床産) 유화광물(硫化鑛物)의 유황동위원소성분(硫黃同位元素成分) 및 동위원소지질온도(同位元素地質溫度)에 관(關)한 연구(硏究))

  • Kim, Kyu Han;Nakai, Nobuyuki
    • Economic and Environmental Geology
    • /
    • v.15 no.3
    • /
    • pp.155-166
    • /
    • 1982
  • Sulfur isotope compositions (${\delta}^{34}S$) of seventy one sulfide minerals from the Shinyemi ore deposits were determined to range from -10.1 to +5.0‰ with a mean value of +2.1‰. These values are roughly comparable to those of various hydrothermal ore deposits in Korea, about +2.0 to +7.0‰ in ${\delta}^{34}S$, suggesting that they are to be same in source of sulfur. The Shinyemi deposits are grouped into two types; the western bedded skarn orebodies and the eastern small pipes and veins. The ${\delta}^{34}S$ values of sulfide minerals from the bedded orebodies (early mineralization) are ranging from -10.1 to +2.5‰, which is relatively wide in range, whereas those of the pipes and veins. (later mineralization) have a narrow range of ${\delta}^{34}S$ values, +2.7 to +5.0‰, regardless of the kind of sulfide minerals. Isotopic temperature obtained from the sphalerite-galena mineral pairs of the New B orebody appeared to be about 400 to $540^{\circ}C$ are reasonably good agreement with the comparable data of skarn mineral assemblages. It is concluded that the west orebodies were formed in earlier stage at higher temperatures than the east orebodies formed later at lower temperatures. Judging from the various data from the present study, the Shinyemi deposits can be defined as a typical contact metasomatic deposit. The source of sulfur in the hydrothermal solutions is considered to be comagmatic with the Shinyemi granodiorite.

  • PDF

CCD Photometric Observations and Light Curve Synthesis of the Near-Contact Binary XZ Canis Minoris (근접촉쌍성 XZ CMi의 CCD 측광관측과 광도곡선 분석)

  • Kim, Chun-Hwey;Park, Jang-Ho;Lee, Jae-Woo;Jeong, Jang-Hae;Oh, Jun-Young
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.2
    • /
    • pp.141-156
    • /
    • 2009
  • Through the photometric observations of the near-contact binary, XZ CMi, new BV light curves were secured and seven times of minimum light were determined. An intensive period study with all published timings, including ours, confirms that the period of XZ CMi has varied in a cyclic period variation superposed on a secular period decrease over last 70 years. Assuming the cyclic change of period to occur by a light-time effect due to a third-body, the light-time orbit with a semi-amplitude of 0.0056d, a period of 29y and an eccentricity of 0.71 was calculated. The observed secular period decrease of $-5.26{\times}10^{-11}d/P$ was interpreted as a result of simultaneous occurrence of both a period decrease of $-8.20{\times}10^{-11}d/P$ by angular momentum loss (AML) due to a magnetic braking stellar wind and a period increase of $2.94{\times}10^{-11}d/P$ by a mass transfer from the less massive secondary to the primary components in the system. In this line the decreasing rate of period due to AML is about 3 times larger than the increasing one by a mass transfer in their absolute values. The latter implies a mass transfer of $\dot{M}_s=3.21{\times}10^{-8}M_{\odot}y^{-1}$ from the less massive secondary to the primary. The BV light curves with the latest Wilson-Devinney binary code were analyzed for two separate models of 8200K and 7000K as the photospheric temperature of the primary component. Both models confirm that XZ CMi is truly a near-contact binary with a less massive secondary completely filling Roche lobe and a primary inside the inner Roche lobe and there is a third-light corresponding to about 15-17% of the total system light. However, the third-light source can not be the same as the third-body suggested from the period study. At the present, however, we can not determine which one between two models is better fitted to the observations because of a negligible difference of $\sum(O-C)^2$ between them. The diversity of mass ratios, with which previous investigators were in disagreement, still remains to be one of unsolved problems in XZ CMi system. Spectroscopic observations for a radial velocity curve and high-resolution spectra as well as a high-precision photometry are needed to resolve some of remaining problems.

Changes of Visual Acuity and Ophthalmic Symptoms in Female Workers examining Silver Plating Products (은도금제품 검사실 여성근로자들의 시력변화 및 안증상)

  • Ryu, Seung-Ho;Son, Jeong-Il;Lee, Soo-Jin;Song, Jae-Cheol
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.3 s.58
    • /
    • pp.567-576
    • /
    • 1997
  • To evaluate the effects of reflected glare on eyes, authors assessed the periodic health examination(1991-1996) & self-administered questionnaire data of a semiconductor producing company. The 13 lead frame(LF) department workers have been exposed to high reflected glare in the process for examining the silver plating products. We compared the data of connector(14) and clerical(12) workers as the non-exposed ones. Among LF department workers, 100% felt their visual acuity worsened(connector:81.8%, clerical:85.7%), and 70% had worn the glasses o. contact lenses(connector : 14.3%, clerical :40%) since working at the company. Major ophthalmic symptoms of the LF workers are asthenopia, tearing, decreased visual acuity, congestion and glare. Decrease of visual acuity by Hahn's line change of the LF workers is significantly high during a 5-year follow-up(p<0.05 by simple regression) compared with connector clerical workers.

  • PDF

Automated patient set-up using intensity based image registration in proton therapy (양성자 치료 시 Intensity 기반의 영상 정합을 이용한 환자 자동화 Set up 적용 방법)

  • Jang, Hoon;Kim, Ho Sik;Choe, Seung Oh;Kim, Eun Suk;Jeong, Jong Hyi;Ahn, Sang Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.97-105
    • /
    • 2018
  • Purpose : Proton Therapy using Bragg-peak, because it has distinct characteristics in providing maximum dosage for tumor and minimal dosage for normal tissue, a medical imaging system that can quantify changes in patient position or treatment area is of paramount importance to the treatment of protons. The purpose of this research is to evaluate the usefulness of the algorithm by comparing the image matching through the set-up and in-house code through the existing dips program by producing a Matlab-based in-house registration code to determine the error value between dips and DRR to evaluate the accuracy of the existing treatment. Materials and Methods : Thirteen patients with brain tumors and head and neck cancer who received proton therapy were included in this study and used the DIPS Program System (Version 2.4.3, IBA, Belgium) for image comparison and the Eclipse Proton Planning System (Version 13.7, Varian, USA) for patient treatment planning. For Validation of the Registration method, a test image was artificially rotated and moved to match the existing image, and the initial set up image of DIPS program of existing set up process was image-matched with plan DRR, and the error value was obtained, and the usefulness of the algorithm was evaluated. Results : When the test image was moved 0.5, 1, and 10 cm in the left and right directions, the average error was 0.018 cm. When the test image was rotated counterclockwise by 1 and $10^{\circ}$, the error was $0.0011^{\circ}$. When the initial images of four patients were imaged, the mean error was 0.056, 0.044, and 0.053 cm in the order of x, y, and z, and 0.190 and $0.206^{\circ}$ in the order of rotation and pitch. When the final images of 13 patients were imaged, the mean differences were 0.062, 0.085, and 0.074 cm in the order of x, y, and z, and 0.120 cm as the vector value. Rotation and pitch were 0.171 and $0.174^{\circ}$, respectively. Conclusion : The Matlab-based In-house Registration code produced through this study showed accurate Image matching based on Intensity as well as the simple image as well as anatomical structure. Also, the Set-up error through the DIPS program of the existing treatment method showed a very slight difference, confirming the accuracy of the proton therapy. Future development of additional programs and future Intensity-based Matlab In-house code research will be necessary for future clinical applications.

  • PDF