• Title/Summary/Keyword: 후처리 공법

Search Result 123, Processing Time 0.035 seconds

Principle and Application of Composting for Soils Contaminated with Hazardous Organic Pollutants (오염토양 정화를 위한 콤포스팅 기술의 원리와 적용에 관한 고찰)

  • Park, Joon-Seok;Lee, Noh-Sup;In, Byung-Hoon;Namkoong, Wan;Hwang, Eui-Young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.9 no.3
    • /
    • pp.77-87
    • /
    • 2001
  • Composting is a cost-effective and environmentally-sound technology to treat soils contaminated with hazardous organic pollutants. Pollutants to be treated are as follows: explosives, phenolic compounds, PAHs, petroleum hydrocarbons, pesticides, and etc. Composting systems are windrow, static pile, and in-vessel. Design and operational parameters of composting are aeration modes, temperature, moisture content, nutrient supplement, amendment added, and etc. Appropriate oxygen concentration of composting for contaminated soils are 5~15%, while some compounds are degraded well at the low $O_2$ concentration of 2~5%. The most diverse microorganisms live in the temperature of $25{\sim}40^{\circ}$. 50~90% of the soil field capacity is the moisture content not to make a problem in composting. Assuming a bacterial chemical equation is $C_{60}H_{87}O_{23}N_{12}P$, theoretical C : N : P from bacterial chemical portion is approximately 20 : 5 : 1. It should be noted that the ratio does not apply to the total organic carbon measured in a waste because not all carbon metabolized by bacteria is synthesized to new cellular material. Initial C/N ratio of 25~40 is optimum. It is more economical to recycle soils or composts than to add commercial microbes.

  • PDF

Modeling and Optimization of High Strength Wastewater Treatment Using the Electro Oxidation Process (전기산화공법을 이용한 고농도폐수 처리공정의 모델링 및 최적화)

  • Lee, Hongmin;Lee, Sangsun;Hwang, Sungwon;Jin, Dongbok
    • Korean Chemical Engineering Research
    • /
    • v.54 no.3
    • /
    • pp.340-349
    • /
    • 2016
  • Electro oxidation system was designed in this study for the reduction of COD (Chemical Oxygen Demand) from high-strength wastewater, produced during refinery turnaround period. First, BDD (Boron Doped Diamond) electrode was synthesized and electro oxidation system of actual industrial wastewater was developed by adopting the synthesized BDD electrode. The experiments were carried out under various operating conditions under certain range of current density, pH, electrolyte concentration and reaction time. Secondly, reaction kinetics were identified based on the experimental results, and the kinetics were embedded into a genetic mathematical model of the electro oxidation system. Lastly, design and operating parameters of the process were optimized to maximize the efficiency of the pretreatment system. The coefficient of determination ($R^2$) of the model was found to be 0.982, and it proved high accuracy of the model compared with experimental results.

Development of Revegetation Measures using Boring Technique in Rock Slopes - Focus on Lespedeza cyrtobotrya - (암반비탈면에 있어서 천공기법에 의한 녹화공법의 개발 - 참싸리를 중심으로 -)

  • Ma, Ho-Seop;Kang, Won-Seok;Park, Jin-Won
    • Journal of Korean Society of Forest Science
    • /
    • v.100 no.4
    • /
    • pp.558-564
    • /
    • 2011
  • This study was conducted to evaluate the effects of early revegetation by analyzing the characteristics of germination and growth of Lespedeza cyrtobotrya using boring technique in rock slopes. After making up a growing basis of approximately 20 cm depth and 10 cm diameter by using a boring machine, the surface of rock slopes was planted with vegetation-plant. The number of germinating populations by soil media was 23 in H.s, 22 in T.s, 12 in M.s, and 1 in M.g.s. The germination rate (%) by soil media was 19.2% in H.s, 18.3% in T.s, 10.0% in M.s and 0.8% in M.g.s. In monthly changes of growth rate, the aspect was northwest direction, the soil media was M.s, and the treatment was microorganism plot. The main factors affecting survivorship and growth of population were soil media and treatment plot. The interaction between each factor had a good effects in bearing ${\times}$ soil media, bearing ${\times}$ treatment plot, soil media ${\times}$ treatment plot. but, it is recommended that the mulching of vegetation plant is highly needed to help the germination of seed and growth of vegetation because of loss of seed and soil media occurred due to rainfall. Therefore, The result suggests that the revegetation technique using boring in rock slope was very efficient in respect of the early revegetation and the landscape.

Effect of Microbial Treatment Methods on Biogrout (미생물 처리 방법이 바이오그라우트에 미치는 영향)

  • Kim, Daehyeon;Park, Kyungho;Kim, Hochul;Lee, Yonghee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.5
    • /
    • pp.51-57
    • /
    • 2012
  • The purpose of study is to understand the possibility of biogrout of soil induced by bacteria. Microbial Calcium Carbonate Precipitation(MCP) has been analysed using the microorganism Bacillus Pasteurii. In order to understand the biogrout of soft ground treated with microbial calcium carbonate precipitation, four types of specimens(sterilization soil, non-sterilization soil, reaction solution and microorganism solution with pre-treatment mix and reaction solution and microorganism solution with post-treatment mix) were made. Scanning Electron Microscope(SEM), EDX and X-ray diffraction(XRD) analyses were performed on the soft ground specimens. On the basis of the preliminary results, it appears that microbial treatment methods using calcium carbonate precipitation may be possible to improve property of biogrout.

STUDIES ON THE MATHEMATICAL KINETICS FOR THE REMOVABLE MOVING SCREEN MEDIA-ACTIVATED SLUDGE PROCESS (회전형 반고정망 활성슬럿지 공법의 수학적 해석에 관한 연구 2. 슬럿지 생산량 및 축적과정과 유출수의 수질에 대하여)

  • HAN Ung-Jun;HAN Yeong-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.12 no.3
    • /
    • pp.175-179
    • /
    • 1979
  • One of the major problems in tile activated sludge system has been difficulty in separating the microbial solids from the treated effluent and in returning them to the aeration tank. Another problem has been the digestion of the excess activated sludge. In constrast, it has not been difficult to separate the microbial solids from the treated effluent from the biological fixed-film systems(RBC process, Trickling Filter, FAST process). These systems have also featured less sludge production. Recently, it was proposed to experiment with the RESMAS process in order to eliminate the settling tank and sludge concentration facilities and to reduce the quantity of excess sludge for final disposal. The effluent quality could be predicted by .the concept of the maximum accumulation capacity. However, the hydraulic characteristics of the screen media in the RESMAS reactor were not dynamic. The object of the present study is to evalute the sludge accumulation rate and effluent quality prediction in the REMSMAS process designed in the dynamic hydraulic structure. This process can eliminate the final sedimentation tank and sludge concentration tank needed in the RBC, CMAS, Trickling Filter and FAST processes. Also, the effluent quality is desirable to compare with other processes. It appeared that the value of the sludge holding capacity was higher than those of the RESMAS and FAST processes, and the periods of the critical operating time were proportional to the substrate hydraulic loadings.

  • PDF

An Evaluation of Slip Coefficient in High Strength Bolt Joint using Zn/Al Metal Spray Corrosion Resistance Method (Zn/Al 금속용사 방식공법을 적용한 고력볼트 접합부의 미끄럼계수 평가)

  • Kim, Tae-Soo;Lee, Han-Seung;Tae, Sung-Ho;Ahn, Hyun-Jin;Oh, Sang-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.5
    • /
    • pp.114-122
    • /
    • 2007
  • In high strength bolted joints, the corrosion of base material causes the reduction of slip resistance of the joints. In this study, tensile tests on slip-critical joints utilizing Zn/Al metal spraying corrosion resistance method were carried out in order to prevent the corrosion and meet the required mechanical characteristics of joints. In addition, slip coefficient and surface roughness were calculated. The key parameters were surface finishing condition and thickness of coating with the identical geometry in all specimens. From the results, it is found that the slip coefficient of the joints with coated finish after sand blast treatment as well as those of non-coated joints with only sand blast treatment were similar or superior to 0.45, which is a specification criteria of slip coefficient in friction-typed joints.

Settlement Restraint of Soft Ground by Low Slump Mortar Injection (저유동설 몰탈주입에 의한 연약지반의 침하억제 효과)

  • 천병식;여유현;정영교
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.6
    • /
    • pp.53-67
    • /
    • 2001
  • In this study the pilot test of CGS as injection method by low slump mortar was performed and the results were analyzed in order to find out the application of this method and effect of settlement restraint. The site far pilot test is adjacent to apartments supported by pile foundations. Sand drain method was performed previously as countermeasures against settlement, but settlement occur continuously because this ground is very soft. Site investigations such as SPT, DCPT and vane shear test were performed to determine the characteristics of ground improvement. Field measurements and FDM analysis were performed on purpose to find out the displacement of ground during injection works. From the results of this study, CGS method can be optimized by the control of diagram, space, depth, injection material, and injection pressure. CGS improved soft ground compositely by the bearing effect of CGS columns and reinforcement of adjacent ground. Considering that increase of N value is about 2.1, CGS can be considered as an effective method to increase the bearing capacity as well as to stop the settlement of soft ground. It is also expected to be economic and effective in improvement of ground when it is used in applicable sites.

  • PDF

Real-scale Experiment for Breach Retardation Effect on the Levee treated with New Substance due to Overtopping (신소재 제방의 월류붕괴 지연효과에 대한 실규모 실험)

  • Ko, Dongwoo;Kang, Woochul;Kim, Jongmin;Kim, Sungjung;Kang, Joongu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.54-54
    • /
    • 2020
  • 본 연구에서는 제방의 세굴이나 붕괴를 방지하기 위해 바이오폴리머(Biopolymer) 기반 신소재를 활용한 흙 제방의 보강공법을 제시하였다. 바이오폴리머 기반 제방의 보강공법은 흙과 바이오폴리머를 소량만 섞어도 흙의 강도 증진시킴과 동시에 빗물에 대한 내침식성과 식생의 생장을 촉진하는 생태성도 뛰어나기 때문에 제방 사면을 보호할 수 있는 친환경적이고 효율적인 공법이다. 이에 안동하천연구센터는 실증실험을 통한 신소재 제방 보강공법의 안정성 검증을 목표로 2 건의 월류붕괴 실험을 수행하였다. 첫 번째는 흙 제방 조건(Case 1)이며, 두 번째는 바이오폴리머 혼합 토양을 사면에 도포한 후 식생이 활착된 조건(Case 2)이다. 제방 붕괴에 따른 수로 내 수위변화를 측정하기 위해 압력식 수위계를 설치하였으며, 영상분석을 위한 다수의 카메라 및 드론을 활용하여 실험의 전 과정을 실시간 촬영하였다. 또한, 제내지 측 사면을 대상으로 월류에 따른 붕괴 지연효과를 정량적으로 제시하기 위해 이미지 픽셀 변화 측정 기법을 통한 시간에 따른 표면 손실률을 산정하였다. 흙 제방과 신소재 처리 제방의 시간에 따른 표면손실률을 비교한 결과, Case 2의 사면손실률이 Case 1에 비해 약 1.5~2.3 배 지연되는 것을 확인하였다. 하지만 단일 조건만으로 실험군과 비교군의 붕괴지연 결과가 제방 성능을 평가함에 있어서 일반화될 수 없으므로 이러한 정량적 평가는 다소 한계가 있다. 향후 이러한 부족한 부분을 해결하기 위한 노력과 다양한 조건의 추가실험을 통한 계측 데이터 및 붕괴지연시간의 평균값을 도출하여 신소재 제방의 안정성을 평가하기 위한 타당한 결과를 도출할 예정이다.

  • PDF

Evaluation of Ozone Resistance and Anti-Corrosion Performance of Water Treatment Concrete according to Types of Metal Spray Coating (수처리시설용 콘크리트의 금속용사 피막 종류에 따른 내오존성 및 전기화학적 방식 성능 평가)

  • Park, Jin-Ho;Choi, Hyun-Jun;Lee, Han-Seung;Kim, Sang-yeol;Jang, Hyun-O
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.61-68
    • /
    • 2019
  • As the pollution of water resources deteriorates due to industrialization and urbanization, it is difficult to supply clean water through a water treatment method using chlorine. Therefore, the introduction of advanced water treatment facilities using ozone is on the increase. However, epoxy which is used as waterproofing and anticorrosives and stainless steel used in conventional waterproofing and anti-corrosive methods have deteriorated because of the strong oxidizing power of ozone, causing problems such as leaking. Moreover, it even causes the durability degradation of a concrete. Therefore, in this study, metal spraying system was used as the means of constructing a metal panel with excellent ozone resistance and chemical resistance which is an easier method than an existing construction method. Ozone resistance was evaluated in accordance with the type of metal sprayed coatings to develop a finishing method which can prevent the concrete structure of water treatment facilities from deterioration. Furthermore, electrochemical stability in actual sewage treatment plant environment was evaluated. Experimental results showed that Ti has superior ozone resistance after spraying and the electrochemical stability in the sewage treatment plant environment showed that Ti has the highest polarization resistance of $403.83k{\cdot}{\Omega}{\cdot}cm^2$, which ensures high levels of durability.

Hydrogen production by plasma pyrolysis-gasification of waste (폐기물의 플라즈마 열분해-가스화에 의한 수소생산)

  • Lee, Jin-Ho;Kim, Young-Suk;Do, Chul-Jin;Hwang, Soon-Mo;Jeong, Seong-Jae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.627-632
    • /
    • 2007
  • 폐기물의 플라즈마를 이용한 열분해-가스화-용융 처리공정은 청정연료 형태로 정화된 합성가스를 얻을 수 있고, 이 합성가스를 WGS 반응과 PSA 공법을 이용하면 고순도 수소로의 전환 및 회수가 가능하다. (주)애드플라텍에서는 자체 보유하고 있는 3톤/일급 플라즈마 폐기물 처리설비와 수소 정제/회수시스템을 연계하여, 폐기물로부터 고순도 수소 생산 ($20Nm^3/h$ 이상)을 위한 플라즈마 폐기물 처리 수소 생산 통합시스템 개발을 진행하고 있다. 합성가스 내 질소 농도를 낮추기 위해 산소를 매질로 하는 100kW급 산소 플라즈마 토치를 제작 하였다. 수소 정제/회수 시스템은 폐기물의 플라즈마 처리 후의 합성가스 생성량과 조성의 변화에 대응할 수 있도록 하였으며 WGS 반응기로 들어가는 합성가스를 가스 컴프레서를 통하여 최대 10기압으로 승압시키고, 고농도 일산화탄소의 효과적인 제거 및 열 회수 극대화가 이루어질 수 있는 최적의 가스처리 시스템으로 구현되도록 하였다. 설치 완료된 WGS 반응기의 성능시험이 플라즈마 처리설비와 연계하여 수행되었으며 WGS 반응기를 거친 일산화탄소의 농도는 1.5% 미만으로 분석되었다. 차기 년도에 설치/가동 예정인 수소 생산용 PSA는 최대 10기압 운전 및 상압재생 방식으로 운전되며 생산된 수소는 최소 99.99%이상의 고순도를 유지할 것으로 기대된다.

  • PDF