• Title/Summary/Keyword: 후관절

Search Result 32, Processing Time 0.039 seconds

Comparisons of Unicortical and Bicortical Lateral Mass Screws in the Cervical Spine : Safety vs Strength (경추부의 후관절 나사못 고정술에서 단피질삽입법과 양피질 삽입법 간의 특성에 관한 비교)

  • Park, Choon-Keun;Hwang, Jang-Hoe;Ji, Chul;Lee, Jae Un;Sung, Jae Hoon;Choi, Seung-Jin;Lee, Sang-Won;Seybold, Eric;Park, Sung-Chan;Cho, Kyung-Suok;Park, Chun-Kun;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1210-1219
    • /
    • 2001
  • Introduction : The purpose of this study was to analyze the safety, pullout strength and radiographic characteristics of unicortical and bicortical screws of cervical facet within cadaveric specimens and evaluate the influence of level of training on the positioning of these screws. Methods : Twenty-one cadavers, mean 78.9 years of age, underwent bilateral placement of 3.5mm AO lateral mass screw from C3-C6(n=168) using a slight variation of the Magerl technique. Intraoperative imaging was not used. The right side(unicortical) utilized only 14mm screws(effective length of 11mm) while on the left side to determine the length of the screw after the ventral cortex had been drilled. Three spine surgeons(attending, fellow, chief resident) with varying levels of spine training performed the procedure on seven cadavers each. All spines were harvested and lateral radiographs were taken. Individual cervical vertebrae were carefully dissected and then axial radiographs were taken. The screws were evaluated clinically and radiographically for their safety. Screws were graded clinically for their safety with respect to the spinal cord, facet joint, nerve root and vertebral artery. The grades consisted of the following categories : "satisfactory", "at risk" and "direct injury". Each screw was also graded according to its zone placement. Screw position was quantified by measuring a sagittal angle from the lateral radiograph and an axial angle from the axial radiograph. Pull-out force was determined for all screws using a material testing machine. Results : Dissection revealed that fifteen screws on the left side actually had only unicortical and not bicortical purchase as intended. The majority of screws(92.8%) were satisfactory in terms of safety. There were no injuries to the spinal cord. On the right side(unicortical), 98.9% of the screws were "satisfactory" and on the left side(bicortical) 68.1% were "satisfactory". There was a 5.8% incidence of direct arterial injury and a 17.4% incidence of direct nerve root injury with the bicortical screws. There were no "direct injuries" with the unicortical screws for the nerve root or vertebral artery. The unicortical screws had a 21.4% incidence of direct injury of the facet joint, while the bicortical screws had a 21.7% incidence. The majority of "direct injury" of bicortical screws were placed by the surgeon with the least experience. The performance of the resident surgeon was significantly different from the attending or fellow(p<0.05) in terms of safety of the nerve root and vertebral artery. The attending's performance was significantly better than the resident or fellow(p<0.05) in terms of safety of the facet joint. There was no relationship between the safety of a screw and its zone placement. The axial deviation angle measured $23.5{\pm}6.6$ degrees and $19.8{\pm}7.9$ degrees for the unicortical and bicortical screws, respectively. The resident surgeon had a significantly lower angle than the attending or fellow(p<0.05). The sagittal angle measured $66.3{\pm}7.0$ degrees and $62.3{\pm}7.9$ degrees for the unicortical and bicortical screws, respectively. The attending had a significantly lower sagittal angle than the fellow or resident(p<0.05). Thirty-three screws that entered the facet joint were tested for pull-out strength but excluded from the data because they were not lateral mass screws per-se and had deviated substantially from the intended final trajectory. The mean pull-out force for all screws was $542.9{\pm}296.6N$. There was no statistically significant difference between the pull-out force for unicortical($519.9{\pm}286.9N$) and bicortical($565.2{\pm}306N$) screws. There was no significant difference in pull-out strengths with respect to zone placement. Conclusion : It is our belief that the risk associated with bicortical purchase mandates formal spine training if it is to be done safely and accurately. Unicortical screws are safer regardless of level of training. It is apparent that 14mm lateral mass screws placed in a supero-lateral trajectory in the adult cervical spine provide an equivalent strength with a much lower risk of injury than the longer bicortical screws placed in a similar orientation.

  • PDF

Acute Low Back Pain from Coexisting Gout and Tuberculous Spondyloarthropathy (급성 요통을 일으킨 결핵과 통풍이 혼재된 척추관절병증)

  • Park, Yung;Ha, Joong Won;Kwon, Ji-Won;Eum, Kwangsik
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.4
    • /
    • pp.351-356
    • /
    • 2021
  • A 67-year-old male patient with a history of epididymectomy and anti-tuberculosis treatment for epididymis tuberculosis was admitted for acute low back pain and radiating pain. The patient had no history of gout but showed hyperuricemia and a bone destruction lesion in the facet joint and lamina of the lumbar spine. A histology examination was performed after a computed tomography-guided needle biopsy, and the findings were compatible with gout spondyloarthropathy and tuberculous spondylitis. The acute symptoms improved after conservative treatment for gouty arthritis. When patients with hyperuricemia risk factors, such as taking anti-tuberculosis drugs, complain of acute low back pain, gout spondyloarthropathy should be considered in a differential diagnosis.

Development of a program for Scoliosis FE Model Automatic Generation (척추측만증 유한 요소 모델 자동 생성 프로그램 개발)

  • 유한규;김영은
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1154-1159
    • /
    • 2004
  • Unexpected postoperative changes, such as growth in rib hump, has been occasionally reported after corrective surgery for scoliosis. However there has been experimental data for explanation of these changes, nor the suggestion of optimal correction method. This numerical study was designed to investigate the main correlating elements in operative kinematics with post-operative changes of vertebral rotation and rib cage deformation in the corrective surgery of scoliosis. To develop a scoliotic spine model automatically, a special program for converting normal spine model to scoliotic spine model was developed. A mathematical finite element model of normal spine including rib cage, sternum, both clavicles, and pelvis was developed with anatomical details. The skeletal deformity of scoliosis was reconstructed, by mapping the X-ray images of a scoliosis into this three dimensional normal spine and rib cage model. The geometric mapping was performed by translating and rotating the spinal colume with the amount analyzed from the digitized 12 built-in coordinate axes in each vertebral image. By utilizing this program, problems generated in mapping procedure such as facet joint overlapping, vertebral body deformity could be automatically resolved.

  • PDF

Biomechanical Evaluation of Total Disc Replacement in Spine (척추 인공디스크 수술의 생체역학적 평가)

  • Choi, Dae Kyung;Park, Won Man;Kim, Yoon Hyuk
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2011.05a
    • /
    • pp.267-268
    • /
    • 2011
  • 본 연구에서는 유한요소 해석 방법을 이용하여 경추 유한요소 모델을 개발하고, 척추 인공디스크 수술 후 경추 분절의 생체역학적 특성을 평가하였다. 반구속 및 비구속 개념의 인공디스크가 삽입된 경추 유한요소 모델의 제 7 경추체를 완전히 고정시키고 추적 경로 방향의 50 N의 압축력을 가한 상태에서 1 Nm의 굴곡과 신전, 측면 굴곡, 비틀림 모멘트를 가하였다. 모든 방향의 하중 조건에서 인공디스크가 삽입된 경추 모델들의 회전량이 정상 경추 모델의 회전량에 비하여 크게 나타났다. 또한 인공디스크를 삽입한 운동 분절에서 정상에 비하여 후관절의 접촉력과 여섯 가지 주요 인대에 걸리는 응력이 높게 나타났다. 본 연구의 결과는 척추 인공디스크 수술 시 수술 방법의 선택뿐만 아니라 새로운 경추 수술용 임플란트 개발을 위한 인체정보 콘텐츠를 구축하는데 유용하게 활용될 수 있을 것으로 기대된다.

  • PDF

A Case Report of Bee Venom Pharmacopuncture Therapy at Facet Joint for the Two Patients with Herniated Intervertebral Disc of Lumbar Spine (신경뿌리병증을 동반한 요추 추간판탈출증 환자의 봉약침 후관절 심부시술 효과에 대한 증례 보고)

  • Ok, Soyoon;Sohn, Soo-ah;Lee, Yujin;Shin, Minseop
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.27 no.4
    • /
    • pp.155-161
    • /
    • 2017
  • The purpose of this study is to research and report the effect of Bee Venom pharmacopuncture therapy at facet joint for the two patients who was diagnosed as herniated intervertebral disc (HIVD) of lumbar spine. Two patients were hospitalized and treated with Complex Korean Medical treatment such as acupuncture, herbal medicine and Essential bee venom (EBV) pharmacopuncture in Dongsuwon hospital of oriental medicine. We measured their pain and function of daily life by numerical rating scale (NRS), straight leg rasing test (SLRT), Roland-morris disability questionnaire (RMDQ). As the result, we found the improvement of gait disturbance, functional disorder, and pain. This study suggested that Bee Venom pharmacopuncture therapy at facet joint is considered to conservative treatment for HIVD of lumbar spine. But further clinical studies are needed to clarify the effect of Bee Venom pharmacopuncture therapy at facet joint for the two patients with HIVD of lumbar spine.

Effects on the Adjacent Motion Segments according to the Artificial Disc Insertion (인공 추간판 적용으로 인한 인접 운동 분절의 영향)

  • Kim, Young-Eun;Yun, Sang-Seok
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.8 s.197
    • /
    • pp.122-129
    • /
    • 2007
  • To evaluate the effect of artificial disc implantation and fusion on the biomechanics of adjacent motion segment, a nonlinear three-dimensional finite element model of whole lumbar spine (L1-S1) was developed. Biomechanical analysis was performed for two different types of artificial disc, ProDisc and SB $Charit{\acute{e}}$ III model, inserted at L4-L5 level and these results were also compared with fusion case. Angular motion of vertebral body, forces on the spinal ligaments and facet joint under sagittal plane loading with a compressive preload of 150 N at a nonlinear three-dimensional finite element model of Ll-S1 were compared. The implant did not significantly alter the kinematics of the motion segment adjacent to the instrumented level. However, $Charit{\acute{e}}$ III model tend to decrease its motion on the adjacent levels, especially in extension motion. Contrast to motion and ligament force changes, facet contact forces were increased in the adjacent levels as well as implanted level for constrained instantaneous center of rotation model, i.e. ProDisc model.

Impact Analysis of the Cervical Spin using a Finite Element Model (유한요소 모델을 이용한 충격력에 따른 경추부의 응답특성 해석)

  • 김영은;박덕용;이춘기
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.5
    • /
    • pp.249-257
    • /
    • 1999
  • A three dimensional finite model of a human neck has been developed in an effort to study the mechanics of cervical spin while subjected to vertical impact. This model consisting of the vertebrae from C1 through C7 including posterior element and ligaments was constructed by 2mm thick transverse CT cross-sections and X-ray film taken at lateral side. Geometrical nonlinearity was also considered for the large deformation on the disc. ABAQUS package was used for calculation and its results were verified comparing with responses of a model under static loading condition with published in-vitro experimental data. There were more cervical fracture in the restrained (compression) mode than in the nonrestrained (flexion-compression and extension-compression) mode. Upper cervical(C1-C2) injuries were observed under compression-extension modes, while lower cervical injuries occurred undjer compression-flexion modes. Posterior ligament distraction without bony damage at the upper cervical spin(C1-C2) were observed secondary to C5-C7 trauma in compression-flexion modes.

  • PDF

Acupuncture for Facet Joint Syndrome: A Review of Clinical Study (후관절 증후군의 침 치료에 대한 문헌 연구 보고)

  • Ji-Hyang Gu
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.33 no.1
    • /
    • pp.13-29
    • /
    • 2023
  • Objectives To evaluate the evidence supporting the effectiveness of acupuncture for facet joint syndrome. Methods We conducted search across 9 electronic databases (PubMed, EMBASE, Cochrane CENTRAL (CENTRAL), KoreaMed, Kmbase, Koreanstudies Information Service System (KISS), ScienceOn, China National Knowledge Infrastructure (CNKI), and Wanfang) to find clinical trials that used acupuncture as treatment for facet joint syndrome. The methodological quality of randomized controlled clinical trials (RCTs) were assessed using the Cochrane Risk of Bias (RoB) tool, while non-randomized controlled clinical trials (nRCTs) were assessed using the Cochrane Risk of Bias Assessment tool for Non-randomized Study (RoBANS) tool. Results Nine RCTs and one nRCT met our inclusion criteria. Fire needle was more effective than medial branch block in terms of visual analogue scale (VAS) after 1 month (p=0.02). Also, Fire needle was more effective than Ibuprofen in terms of VAS and oswestry disability index (ODI) (p<0.05). However, in the rest of the study results, the intervention group did not show a statistically significant difference than the control group. Conclusions Although our review found encouraging but limited evidence of acupuncture for facet joint syndrome, most of the studies included in the analysis were evaluated as methodologically high risk of bias. From now on further well-designed RCTs should be encouraged.

Clinical Effects of Fluoroscopy Guided Interventional Microadhesiolysis and Nerve Stimulation (FIMS) on Cervical Zygapophyseal Joints in Patients with Chronic Cervical Radicular Pain (경추성 방사통을 가진 만성통증환자에서 경추 후관절에 대한 투시영상하 중재적 미세유착 박리 및 신경자극요법의 임상적 효과)

  • Kim, Eun Ha
    • The Korean Journal of Pain
    • /
    • v.20 no.1
    • /
    • pp.31-39
    • /
    • 2007
  • Background: Cervical radicular pain can arise fromvarious structures, including spinal nerves, discs, zygapophyseal joints, ligaments, and myofascial connective tissue. However, no adequate experiments have been found regarding methods for the microadhesiolysis of adhesional connective tissue around the zygapophyseal joints and nerves. The first objective of this study was to ascertain the effect of fluoroscopy guided interventional microadhesiolysis and nerve stimulation (FIMS) on chronic cervical radicular pain caused by zygapophyseal joint dysfunction. The second objective was to identify the duration of pain alleviation, as well as commonly occurring regions for zygapophyseal joint dysfunction. Methods: Twenty-eight patients were diagnosed with cervical radicular pain. The cervical zygapophyseal joints and adhesional structures around the cervical zygapophyseal joints were stimulated by adhesiolysis with a rounded needle; the procedure was performed once every second week. A visual analogue scale (VAS) for pain and neck range of motion (ROM) were used as indices for evaluating the degree of pain 1 and 3 months after completion of the procedures. A relief effect of FIMS was accepted when the VAS index decreased 50% compared with a previous VAS, and when there was absence of limitation of ROM. Results: Among the patients, 52% showed zygapophyseal joint dysfunction in C5-6, 38% in C4-5, 7% in C2-3, and 3% in C6-7. After performing FIMS, the VAS index decreased in most of the patients after 1 and 3 months (92.8% and 75%, respectively), and treatment frequency was $2.7{\pm}1.2$. There was no correlation between the number of FIMS procedures and the degree of VAS. Conclusions: FIMS is considered an effective modality in patients suffering from cervical radicular pain.

Ultrasound-guided Distance Measurements of Vertebral Structures for Lumbar Medial Branch Block (초음파 유도하에서의 요추부 후관절 내측지 차단술을 위한 주요 척추 구조물의 거리 측정)

  • Moon, Jin Cheon;Shim, Jae Kwang;Jo, Kwang Yun;Yoon, Kyung Bong;Kim, Won Oak;Yoon, Duck Mi
    • The Korean Journal of Pain
    • /
    • v.20 no.2
    • /
    • pp.111-115
    • /
    • 2007
  • Background: Selective diagnostic blocks of the medial branches of the dorsal primary ramus are usually performed under the guidance of fluoroscopic or computed tomography. Recently, however, ultrasound guidance has been suggested as an altemative method. In this study, the distances between the vertebral structures were measured and compared with the values measured using magnetic resonance imaging (MRI) to assess the clinical feasibility of using ultrasound-guided block in Korean patients. Methods: Five male and 15 female patients were enrolled in this study. The target point of the medial branch block in our study was the groove at the base of the superior articular process, We measured the depth from the skin to the target point at the transverse process (d-TP) and to the most superficial point of the superior articular process (d-AP). Results: The d-TP and d-AP values measured under ultrasound guidance were concordant with the values measured using MRI. Conclusions: The images of the bony landmarks obtained under ultrasound examination could be useful for ultrasound-guided lumbar medial branch block.