Study on the Coercive Field Strenght Noise Depends on The Magnetic Field Annealing Effect of Amorphous Ribbon (비정질 리본의 자기장중 열처리에 의한 보자력 노이즈의 변화에 관한 연구)

  • 최근화;손대락
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.2
    • /
    • pp.150-153
    • /
    • 1994
  • Magnetic field annealing method has been used to obtain proper hysteresis loop shapes which are useful to a device using amorphous ribbon. In this study, two pairs of Helmhotz coils were used to apply longitudinal and transverse magnetic field during annealing. For the measurement of coercive field strength noise which depends on magnetic field annealing, Co-based amorphous alloy ribbon $VITROVAC^{\circledR}$ 6030 was used. For the sample which was annealed under dc transverse and dc longitudinal magnetic field, coercive field strength noise was nearly independent of magnetizing frequency ranging from 1 to 100 kHz, but dc transverse and ac longitudinal magnetic fields annealed samples show that the coercive field strength noise decreased in power of magnetizing frequency. When magnetic domain nucleation occurred, the coercive field strength noise increased remarkably and decreased in power of magnetizing frequency.

  • PDF

The Study on the Magneization of Gas Pipliles according to Distortion and Compensation of Measured Signals in MFL System (자기누설 탐상시스템에서 가스관의 착자에 의한 탐상신호 왜곡 및 보상에 관한 연구)

  • Park S. H.;Seo K.;Jung H. W.;Park G. S.;Han S. J.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1004-1006
    • /
    • 2004
  • MFL PIG는 빠른 속도로 주행하면서 MFL 신호를 측정하여 기록하게 된다. PIG가 주행함에 따라 MFL 신호를 왜곡시키는데 가스관에 인가되는 강한 자기장으로 인하여 가스관이 착자되어 왜곡이 발생한다. 가스관의 착자는 종방향 착자와 횡방향 착자로 나눌수 있으며, 횡방향 착자는 검출신호를 증가시키거나 감소시키는 방향으로 왜곡을 발생시키고, 종방향 착자는 인가돼는 자기장과 수직이 되므로 검출신호를 크게 왜곡시킨다. 따라서 검출신호를 보정하여 실제 결함에 의한 신호를 검출하여야 한다. 본 연구에서는 가스관의 착자에 의한 영향을 분석하고 신호보정에 관하여 연구하였다.

  • PDF

Effect of Transverse Magnetic Field on Dose Distribution of High Energy Electron Beam (횡방향 자기장이 고에너지 전자선의 선량분포에 미치는 영향)

  • Oh, Young Kee;Kim, Ki Hwan;Shin, Kyo Chul;Kim, Jhin Kee;Kim, Jeung Kee;Jeong, Dong Hyeok;Cho, Mun Jun;Kim, Jun Sang;Yoon, Sun Min;Kim, Sung Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.4
    • /
    • pp.209-213
    • /
    • 2007
  • In this work we have measured the dose distribution and the percent depth dose of 20 MeV electron beam using the X-OMAT films in order to verify the effects of transverse magnetic field on high energy elecrtron beam in a phantom. The result shows about 30% increase of the percent depth dose at 4.5 cm depth under the transverse magnetic field of 1.5 Tesla at 7.5 cm depth. We have verified that these were in an agreement with other theoretical results.

  • PDF

Analysis of Low Field Microwave Absorption Properties in CoFe/MnIr Thin Film (CoFe/MnIr 박막 재료에서 저자장 마이크로파 흡수 특성 분석)

  • Kim, Dong Young;Yoon, Seok Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.3
    • /
    • pp.74-78
    • /
    • 2015
  • We measured the low field microwave absorption (LFMA) and ferromagnetic resonance (FMR) signals at various magnetic field angle in exchange biased CoFe/MnIr thin film. The LFMA signals were dominantly related to the magnetization rotation process. In order to analyze the LFMA signal, we calculated transverse magnetization ($M_{\tau}$) and permeability (${\mu}_{\tau}$) for CoFe/MnIr thin film by using S-W model, which magnetic parameters of exchange bias ($H_{ex}$ = 58.5 Oe) and uniaxial anisotropy field ($H_k$ = 30Oe) was obtained from FMR signals. The LFMA signal at hard axis showed similar behavior compared with that of $M_{\tau}$. As the magnetic field angle approach to the perpendicular to hard axis, the LFMA signals were depending on both of $M_{\tau}$ and ${\mu}_{\tau}$.

Monte Carlo Calculation on the Dose Modulation Using Dynamic Magnetic Fields for 10 MV X-rays (움직이는 자기장을 이용한 10 MV X-선의 선량변조에 관한 몬테칼로 계산)

  • Kim, Ki Hwan;Oh, Young Kee;Shin, Kyo Chul;Kim, Jhin Kee;Jeong, Dong Hyeok;Kim, Jeung Kee;Cho, Moon June;Kim, Sun Young
    • Progress in Medical Physics
    • /
    • v.18 no.4
    • /
    • pp.221-225
    • /
    • 2007
  • Monte Carlo calculations were performed to demonstrate the dose modulation with dynamic magnetic fields in phantom. The goal of this study is to obtain the uniform dose distributions at a depth region as a target on the central axis of photon beam under moving transverse magnetic field. We have calculated the depth dose curves for two cases of moving magnetic field along a depth line, constant speed and optimal speed. We introduced step-by-step shift and time factor of the position of the electromagnet as an approximations of continuous moving. The optimal time factors as a function of magnetic field position were calculated by least square methods using depth dose data for static magnetic field. We have verified that the flat depth dose is produced by varying the speed of magnetic field as a function of position as a results of Monte Carlo calculations. For 3 T magnetic field, the dose enhancement was 10.1% in comparison to without magnetic field at the center of the target.

  • PDF

Characteristics Testing of the ECT Bobbin Probe for Steam Generator Tube Inspection of Nuclear Power Plant (원전 증기발생기 전열관 와전류검사 보빈탐촉자의 특성 시험)

  • Nam, Min-Woo;Lee, Hee-Jong;Cho, Chan-Hee;Yoo, Hyun-Joo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.386-395
    • /
    • 2010
  • The steam generator management program(SGMP) has recently defined the procedures for the qualification of eddy current hardware and technique. These procedures provide two basic methods for qualification. The first way is to qualify the equipment or the probe by using the flaw mechanism and method of the pulled tubes from the heat exchangers or the artificial flawed tubes. The second way is to verify the equivalency with the characteristics of the qualified equipment or probe. In this case, the qualified equipment or probe may be modified to substitute or replace instruments or probes without re-qualification provided that the range of essential variables defined in the examination technique specification sheet are met. This study is to describe the result of the comparative performance evaluation of bobbin coil eddy current probes manufactured by KEPCO Research Institute and probes manufactured by a foreign manufacturer. As a result of this study, although there were minor differences between the two kinds of probes, it was evaluated that the two kinds of probes were almost identical in the significant performance characteristics described in the KEPCO Research Institute guideline.

Optical measurement and analysis technique for spin-orbit torques (스핀-궤도 돌림힘의 광학적 측정 및 분석법)

  • Yun, Sang-Jun;Moon, Joon;Whang, Hyun-Seok;Choe, Sug-Bong
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.1
    • /
    • pp.1-3
    • /
    • 2015
  • We demonstrate here an optical measurement technique to quantify the spin-orbit torques. The magnetization dynamics induced by the spin-orbit torques with a sinusoidal current injection is measured by use of polar magneto-optical Kerr effect. The measured signal is then analyzed based on the Landau-Lifhshitz-Gilbert equation with consideration of the spin-orbit torques. The present measurement technique is applied to Pd/Co/Pt films and then, the longitudinal and transverse components of the spin-orbit torques are successfully quantified. The present optical technique provides an alternative way to quantify the spin-orbit torques.