• Title/Summary/Keyword: 회전 채널

Search Result 103, Processing Time 0.031 seconds

A Study on Mixing Enhancement by Rotating and Oscillating Stirrers in the Micro Channel (미소채널 내 회전교반기와 진동교반기에 의한 혼합향상의 연구)

  • An Sang-Joon;Kim Yong-Dae;Maeng Joo-Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.5 s.248
    • /
    • pp.430-437
    • /
    • 2006
  • The mixing effect is studied by comparing rotating and oscillating stirrers in the micro channel. The cases of Re=10 to 80 with various stirring speeds are considered to analysis the effect of Re and stirrer speed for the mixing. Under Re=20, the oscillating stirrer represents better mixing rate than the rotating stirrer up to the critical stirrer speed which has a maximum efficiency. Over Re=30, the results of oscillating and rotating stirrer show that the faster the stirrer speed, the higher the mixing effect within the concerned stirrer speed range and the oscillating stirrer keeps the higher mixing rate. It was found that the mixing effect is a function which has an optimum of the Reynolds number and the stirrer speed. The D2Q9 Lattice Boltzmann Method is used due to the merits of calculation for the unsteady flow with moving boundary.

Synchronization for Wireless LAN System Using OFDM Technique (OFDM 방식을 이용한 무선 LAN 시스템의 동기)

  • Yun, Kyung-Seok;Choi, Seung-Kuk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.1B
    • /
    • pp.79-89
    • /
    • 2002
  • A synchronization method is presented for IEEE 802.11a wireless OFDM system. First the coarse symbol synchronization is achieved by measuring the moving power average of the received envelope signal. The detection probabilities and optimum thresholds for the symbol synchronization are derived. By measuring the correlation between the short training signal and received envelope signal, fine symbol synchronization can be acquired. And the frequency synchronization is achieved using long training signal. A symbol synchronization error causes a phase rotation of the constellation. After the compensation for fading channel, the rotation due to the symbol timing error can be corrected. With this method, synchronization can be well achieved over frequency selective channels.

Analysis of Upper Limb Movement Using Bio-Impedance (임피던스를 이용한 상지 운동 분석)

  • Kim, Soo-Chan;Nam, Ki-Chang;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.461-464
    • /
    • 2001
  • 본 연구에서는 생체 임피던스를 이용하여 3채널 상지(upper arm) 운동 분석 시스템을 제작하였다. 각 채널은 상지의 외전(supination)과 내전(pronation), 팔꿈치(elbow)의 폄과 굽힘, 손목(wrist)의 평과 굽힘에 따른 각 관절의 임피던스 변화를 얻을 수 있도록 설계되었다. 상체 임피던스는 전극의 부착위치에 의존하므로 정밀한 감지를 위해 상지 운동에 대한 임피던스의 변화와 각도계(goniometer)의 각도 변화와의 상관관계를 통하여 상관 관계가 높고, 변화량이 가장 크고 다른 관절의 움직임에 따른 영향이 최소인 곳을 찾아 이를 최적의 전극 위치로 정하였다. 그리고, 선정된 최적의 전극 위치에서 임피던스 변화를 얻어 상지 운동을 분석해 보았다. 최적의 전극 위치에서 손목과 팔꿈치의 각도 변화와 임피던스 변화의 상관 계수는 각각 0.94, -0.97로 아주 높은 상관 관계를 보였다. 또한 이전의 다른 연구에서 임피던스 방법으로 구현해 본적이 없는 팔의 회전(rotation)도 분석이 가능하였다. 이 시스템은 피검자의 동작에 거의 제한을 주지 않고, 가벼우며, 장시간 측정이 용이할 뿐만 아니라 시스템 구성이 영상 분석기에 비해서 단순하다는 장점을 가지고 있다. 본 연구에서 제안하는 방법은 재활과 생체역학, 로봇의 원격 제어, 그리고 가상 현실에서의 동작 구현 등에 활용 할 수 있을 것으로 사료된다.

  • PDF

Timing Synchronization with Channel Impulse Response in OFDM Systems (채널 임펄스 응답을 이용한 OFDM 시스템 시간 동기)

  • Kang, Eun-Su;Han, Dong-Seog
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.7 s.361
    • /
    • pp.53-58
    • /
    • 2007
  • OFDM (orthogonal frequency division multiplexing) is an effective modulation technique for high speed transmission over fading channels. However, it has a high bit error rate in the receiver if there is an error on frame synchronization because of phase rotation. A coherent OFDM system has to acquire exact timing synchronization of fraction and integer sampling positions. When a sampling offset exist the performance of a receiver will be degraded severely. In this paper, we propose an algorithm that acquires the fractional sampling offset in OFDM systems. This scheme compares the channel impulse responses with the early and late sampled signals having 0.5 sample offset from the estimated sampling positions by correlation with the received and training samples. Its performance is verified by computer simulations in multipath channels.

Ti:PPLN Šolc-type Integrated Optical wavelength filters utilizing polarization-mode conversion for WDM optical networks (편광모드 회전을 이용한 WDM 광 네트워크용 Ti:PPLN Šolc-형 집적광학 파장필터에 관한 연구)

  • Jung, Hong-Sik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.4
    • /
    • pp.161-168
    • /
    • 2009
  • We demonstrated $\check{S}$olc-type wavelength filters in periodically poled Ti-diffused lithium-niobate channel optical waveguide (Ti:PPLN). A $\check{S}$olc-type transmission spectrum based on the polarization-mode conversion was observed experimentally in PPLN with period 16.6${\mu}m$. A reasonable explanation of such a phenomenon was presented. A polarization-mode converted transmission peak was observed at wavelength 1272.49nm. The FWHM and sidelobe of spectrum are about 0.23nm and 7 dB, respectively.

  • PDF

Automatic Gain Flattening Control and Automatic Gain Control Using an All Optical Method in an Optical Amplifier (광증폭기의 이득과 이득 평탄화를 동시에 자동 제어하는 완전 광학적 방법)

  • Choi, Bo-Hun;Lee, Sang-Soo
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.5
    • /
    • pp.261-265
    • /
    • 2009
  • Our amplifier using an all optical method and a fixed GFF achieved automatic gain flatness throughput the C-band without any NF degradation, and simultaneously achieved a constant 25 dB gain, while input signals were varied between one channel and forty WDM channels. When thirty nine channels were added and dropped, the transient gain variation of the survival channel was not greater than the steady-state gain variation, and its wavelength dependency was negligible.

Design of Dual-Polarized Monopulse Cassegrain Antenna for W-Band Millimeter-Wave Seeker (W-대역 탐색기용 이중편파 모노펄스 카세그레인 안테나 설계)

  • Lee, Kook Joo;Jung, Chae-Hyun;Baek, Jong-Gyun;Park, Chang-Hyun;Nam, Sangwook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.3
    • /
    • pp.261-268
    • /
    • 2016
  • In this paper, dual-polarized monopulse cassegrain antenna for W-band millimeter-wave seeker was proposed and the performances were verified by the measured results of the fabricated antenna. Dual-polarized monopulse Cassegrain antenna consists of main/subreflector, dual-polarized feed horn and monopulse comparator. The proposed feed horn has $2{\times}2$ array square waveguide feeding structure to make monopulse signals and it was designed using 90 degree rotational symmetric structure to receive dual-polarized signals. At the sum and difference channel, the measured vertical and horizontal polarization radiation pattern were similar. Measurement gains are 35.1 dBi for v-pol. and 35.6 dBi for h-pol. at the center frequency with 0.5dBi difference between each polarization and the side lobe level is below -21.6 dB.

MTF Evaluation according to change in posture and channel during CT examination for wrist Joint : X-axis and Z-axis changes around Isocenter (손목관절 CT 검사 시 자세 변화와 채널 변경에 따른 MTF 평가 : Isocenter를 중심으로 X-축, Z-축 변화)

  • Seo, Min Jae;Lim, Jong Chon;Jung, Dabin;Han, Dong Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.811-817
    • /
    • 2020
  • This study aims to evaluate the Modulation Transfer Function (MTF) according to the change in the number of channels of the CT examination device by changing the posture of the patient to the X-axis and Y-axis in the wrist joint CT examination. Using a CT device and a wrist phantom, the test was performed by moving 0 (matched), 5, 10, and 15 cm in the X-axis around the isocenter, and the Z-axis was rotated by -20° and -40°. For the test, 16, -40 and 64 channels were used to check whether there was a difference for each number of channels. The examined images were compared by measuring the MTF values of the ulna and left and right sides of the radius. In the experiment where the isocenter was moved along the X-axis, the MTF value decreased with an increase in the moving distance, and the MTF value was found to be unaffected by the number of channels. In the experiment in which the wrist joint was rotated by -20° and -40° on the Z-axis, the degree of deviation and MTF were found to be irrelevant. It was not related to the number of channels either. In conclusion, the movement of the wrist along the X-axis should be restrained as much as possible for a wrist joint CT scan, whereas deviation around the Z-axis depending on the environment for the patient would not affect the MTF of the image.

Numerical Analysis of Heat Transfer in the Ribbed Channel Inserted with Tape (테이퍼가 설치된 리브(rib)이 있는 채널의 열전달에 대한 수치해석)

  • Kang, Ho-Keun;Ahn, Soo-Whan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.638-644
    • /
    • 2010
  • Numerical predictions of a fully developed turbulent flow through a square duct ($30mm{\times}30mm$) with twisted tape inserts and with twisted tape plus interrupted ribs are respectively conducted to investigate regionally averaged heat transfer and flow patterns. A rib height-to-channel hydraulic diameter(e/$D_h$) of 0.067 and a lengthto-hydraulic diameter(L/$D_h$) of 30 are considered at Reynolds number ranging 8,900 to 29,000. The interrupted ribs are axially arranged on the bottom wall. The twisted tape is 0.1 mm thick carbon steel sheet with diameter of 28 mm, length of 900 mm, and 2.5 turns. Each wall of the square channel is composed of isolated aluminum sections. Two heating conditions are investigated for test channels with twisted tape inserts and rib turbulators: (1) electric heat uniformly applied to four side walls of the square duct, and (2) electric heat uniformly applied to two opposite walls of the square channel. The results show that uneven surface heating enhances the heat transfer coefficient over uniform heating conditions, and significant improvements can be achieved with twisted tape inserts plus interrupted ribs.

Analysis of Microchannel Flow Fields Using Micropolar Fluid Theory (미세극성유체 이론을 이용한 마이크로 채널내의 유동장 해석)

  • Choi, G.W.;Kim, J.H.;Kim, Youn-J.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.196-201
    • /
    • 2001
  • In this paper, we have described the microchannel fluid behavior in a slot between rotating curvilinear surfaces of revolution using micropolar fluid theory. ]n order to solve this problem, we have used boundary layer equations and applied non-zero values of the microrotation vector on the wall. The results are compared with the corresponding flow problems for Newtonian fluid. Results show that both the velocity distribution and the microrotation component distribution for a micropolar fluid are lower than that of a Newtonian fluid.

  • PDF