• Title/Summary/Keyword: 회전자

Search Result 1,524, Processing Time 0.031 seconds

Effective Measuring Method of Discontinuity Orientation (불연속면 방향의 효율적인 측정 방안)

  • 김해경;고영구
    • The Journal of Engineering Geology
    • /
    • v.13 no.3
    • /
    • pp.321-334
    • /
    • 2003
  • This study is aimed at the effective measurement plan of discontinuity orientation on rock mass. The discontinuity orientation is expressed as three methods. strike/dip. dipdirection/dip (a three digit number / a two digit number) and right hand rule. Generally, strike/dip is measured with clinometer. and dipdirection/dip with silva compass(type15). A sign of strike/dip. discontinuity orientation is used to geological survey. and dipdirection/dip to engineering. Dipdirection/dip converted by strike/dip measured with clinometer is useful on the statistical analysis of a lot of data. To measure the azimuth of the dip with clinometer and to change strike/dip to dipdirection/dip may have potential errors in each person. The newly designed apparatus, clinometer equipped by a rotational azimuth plate and an arrow to measuring strike and dipdirection, has been developed to measure effectively the discontinuity orientation with two method (strike/dip and dipdirection/dip). The measuring method of discontinuity orientation with clinometer having newly designed apparatus is effective one for accurate measurement of strike as well as dipdirection which is degrees counted clockwise from true north. Used by clinometer with newly designed apparatus, concurrent measuring strike/dip and dipdirecton/dip of discontinuity is possible. In application to measuring discontinuity orientation on rock slope, it has been recognized that the newly designed method, unambiguously, led to drop measuring errors comparing with existing measuring apparatuses. Therefore, it is considered that measuring method of discontinuity orientation (strike/dip and dipdirecton/dip) by the newly designed apparatus is useful to one in geological engineering investigation of road design, and to unskilled investigator.

Application of Tuned Mass Damper to Suppress Man-Induced Vibrations of Cable Stayed Foot-bridge (사장교형식 보도교의 보행진동제어를 위한 TMD 적용)

  • Kim, Yun-Seok;Lee, Seung-Woo;Kim, Jae-Min;Chang, Seong-Kyu
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.74-74
    • /
    • 2011
  • 본 연구에서는 중앙경간 54m, 교폭 4m의 사장교형식의 보도교로 측경간은 계단으로 이루어진 1경간 케이블교량을 대상으로 보행하중에 의한 수직진동을 제어하기 위해 제진장치(TMD)를 적용하기로 하고 실물 TMD의 설계 및 제작 그리고 설치 및 제어성능실험을 수행하였다. 우선 사장교형식의 교량. 그리고 1경간 교량이라는 점에서 상대적으로 감쇠율이 낮을 것으로 예측되었고 또한 54m의 경간장이 보행자가 가진 주파수에 근접한 고유진동수를 나타낼 것으로 사료되어 Eurocode 2 part 2(EC5-2)의 규준에 따라 1인 및 다수 보행하중에 의한 보도교의 발생가속도를 산출하였다. 이 경우 최대가속도는 다수의 보행자가 연속적으로 진행할 때 발생하였으며, 수직방향의 가속도가 사용성기준을 초과하는 것으로 나타났다. 또한 구조해석프로그램에 의한 고유치 해석결과, 보행하중의 주파수대역내에 진동모드가 존재하는 것으로 나타났다. 따라서 본 교량의 설계단계에 있어서 보행진동을 제어하기 위하여 유지관리가 용이한 수동형의 동조질량감쇠장치(Tuned Mass Damper)를 적용하기로 하였으며 TMD의 설계에서는 TMD의 제어목표를 만족시킬 수 있는 TMD의 가동질량(moving mass)을 우선적으로 결정하였고, 이로부터 Den Hartog의 제안식에 따라 TMD의 고유진동수비, 유효감쇠비를 산정하였다. 산정된 변수들을 이용하여 설계된 TMD는 현장설치 및 튜닝의 편의성을 고려하여 수평 외팔보형식으로 설계, 제작되었으며 제작된 TMD의 경우 회전축에 대해 질량, 스프링, 댐퍼의 중심거리를 조정함으로써 TMD의 진동수, 강성, 감쇠력을 상대적으로 매우 용이하게 조절할 수 있으며, 조정범위 또한 광범위하여 일반 TMD에 비해 현장설치시 대상구조물에 동조시키기가 용이하며, 작동시 마찰감쇠가 거의 없다는 장점이 있다. 현장설치전에 제작된 TMD를 대상으로 자유진동 시험을 통하여 질량의 중심거리, 스프링 크기 그리고 댐퍼의 설치유무를 각각 변화시키며 TMD의 자유진동 데이터를 취득하였다. 각각의 시험에서 얻어진 데이터로부터 스펙트럼해석을 통하여 고유진동수를 구하였고, 자유진동 파형으로 부터 감쇠비를 구하였다. TMD는 일반적으로 제어모드의 변형형상이 가장 큰 곳에 설치되었을 때 최대의 제진효과를 발휘할 수 있다. 그러나 현장여건상 설치가 불가능하거나 미관을 해치는 경우에는 가능한 범위 내에서 TMD 제어효율이 가장 크게 발휘할 수 있는 곳을 선택하여야 한다. 본 보도교의 경우, 중앙경간 중심부에서 가장 큰 모드변형형상을 나타내지만, 보도교의 상판 연결부 등에 따른 TMD 시공문제로 인하여 TMD 설치위치는 교량 중앙에서 양 방향으로 1.25m 떨어진 곳에 대칭으로 총 2기를 설치하기로 하였다. 일반적으로 TMD의 모든 설계변수는 구조물의 설계단계에서 수행된 구조해석결과에 근거하여 설정하므로 완공된 구조물, 즉 실제보도교의 동적특성을 계측하여 정확하게 진동수를 튜닝하여야 한다. 구조해석에 의한 보도교의 수직방향(TMD 작동방향) 고유진동수는 1.5225 Hz이며, 감쇠비는 규준에 의하여 0.6 %로 가정하였다. 그러나 이 값들은 구조해석모델 및 재료적 특성과 시공상의 오차에 의하여 실제와 다를 수 있으므로 현장계측에 의한 확인이 요구된다. 또한 TMD의 제진효율이 설계시의 목표대로 확보되었는지도 확인해야 하므로 현장튜닝 및 성능시험을 실시하였다. 보도교의 가진은 사전에 실시한 상시 미진동계측결과를 토대로 2Hz를 목표로 하여 인력가진실험을 수행하였고, 탁월진동 주파수는 1.9896Hz로 나타나 구조해석결과와 오차가 있음을 알 수 있다. 가진실험결과를 토대로 TMD의 진동수를 최적진동수비로 튜닝하고 인력가진 실험을 다시 실시하여 TMD의 진동제어성능을 검토하였다. TMD 튜닝 전, 후의 보도교 감쇠비를 비교한 결과, TMD를 설치함으로써 약 4.218%의 감쇠비 증가가 있음을 알 수 있다.

  • PDF

The effectiveness of MRI evaluation after anterior cruciate ligament reconstruction using hamstring tendon autograft (자가 슬괵건을 이용한 전방십자인대 재건술 후 결과 판정에 있어 MRI 검사의 유용성)

  • Kim, Jin-Goo;Kim, Young-Woo;Lee, Soo-Won;Shim, Jae-Chan;Oh, Soo-Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.1
    • /
    • pp.32-39
    • /
    • 2008
  • Purpose: To evaluate the effectiveness of MRI after ACL reconstruction with femoral tunnel at 10 o'clock position. Materials and Methods: MRI findings of 29 patients after ACL reconstruction using hamstring tendon autograft were evaluated. The mean period from operation to MRI was 18.9 months($7{\sim}40$ months). Signal intensity, morphology and continuity of graft, femoral insertion, graft angle, roof impingement, cross pin breakage and position were evaluated. Those findings were compared with KT-2000, Lysholm knee score and pivot shift test. Results: There was no significant correlation between signal intensity of graft and the duration to MRI. Most common pattern of the morphology was straight, and the continuity was well-preserved. 13 cases of femoral tunnel insertion were zone 4 and 16 were zone 3. There were no roof impingement. 10 cases showed cross pin breakages, of which 5 were found at the outside of distal femoral posterior cortex. 9 showed cross pin directed posteriorly in axial view. There was no significant correlation between clinical results and cross pin breakage. Conclusion: MRI examinations after ACL reconstructions are useful to evaluate the graft status, position of the graft and cross pins. Since the direction of the cross pin is important especially in 10 o'clock femoral position, care should be taken to avoid cross pin breakage.

  • PDF

Two Possible Space Groups of Ttis(tekaethylammonium) [bis(trimetaphosphate $\kappa^3O, O^', O^{"}$)] Vanadate(3-),$[V(P_3O_9)_2](NC_8H_{20})3$ (Tris(tetraethylammnnium) [bis(trimetaphosphate $\kappa^3O, O^', O^{"}$)] Vamdate(3-),$[V(P_3O_9)_2](NC_8H_{20})_3$,의 두가지 가능한 공간군)

  • 서일환;이진호
    • Korean Journal of Crystallography
    • /
    • v.5 no.1
    • /
    • pp.1-6
    • /
    • 1994
  • Two possible space groups of the comfound, VP6N3018C24H:60, are: P 1, a=14.022(1), b=12.644(2), c= 12.640(1)A, a=8038(1), B=102.12(1), r=102.16(1), V=2124.1A3, Z=2, μ=0.47cm-1, d=1.46g/cm3, R=0.083 for 3350 independent reflections with Fo>4o IFI, and C2/c, a=19.32(2), b=16.32(2), c=14.02(1)A, B=105.98(5), β=105.98(5), V=4248.2A3, Z=4 R=0.083 for 1590 independent reflections with Fo>4c IFoI . In the space group P T, there are two monlecules in a unit cell. Vanadium atoms in the two monlecules occupy the two different special positions such that the complete monlecules are accomplished by the two independent center of symmetry. Therefore two different half molecules of bis(trimetaphosphate)vanadate and three molecules of tetraethylammonium are the asymmetric unit in a unit cell. In the space group C2/c, however, the vanadium atom is located at a special position with centrosymmetry, and a two-fold symmetry axis passes through C2/c, N2 and C25 atoms. Therefore the asymmrtic unit in a unit cell consists of a half molecule of bis(trimetaphosphate)vanadate and one and a half molecules of tetraethylammonium. All the molecular conformations in both space groups are very similar: six oxygen atoms coordinated to a vanadium atom in the bi s(trimetaphosphate)vanadate molecule form an octahedron and the four carbon atoms bonded to a nitrogen atom in the tetraethylammonium molecule are disordered so that the eight carbon atoms around nitrogen atom exhibit an irregular dodecahedral form.

  • PDF

A new protocol of the sliding mechanics with Micro-Implant Anchorage(M.I.A.) (Micro-Implant Anchorage(MIA)를 이용한 Sliding mechancis)

  • Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.30 no.6 s.83
    • /
    • pp.677-685
    • /
    • 2000
  • Anchorage plays an important role in orthodontic treatment. Because of limited anchorage Potential and acceptance problems of intra- or extraoral anchorage aids, endosseous implants have been suggested and used. However, clinicians have hesitated to use endosseous implants as orthodontic anchorage because of limited implantation space, high cost, and long waiting period for osseointegration. Titanium miniscrews and microscrews were introduced as orthodontic anchorage due to their many advantages such as ease of insertion and removal, low cost, immediate loading, and their ability to be placed in any area of the alveolar bone. In this study, a skeletal Class II Patient was treated with sliding mechanics using M.I.A.(micro-implant anchorage). The maxillary micro-implants provide anchorage for retraction of the upper anterior teeth. The mandibular micro-implants induced uprighting and intrusion of the lower molars. The upward and forward movement of the chin followed. This resulted in an increase of the SNB angle, and a decrease of the ANB angle. The micro-implants remained firm and stable throughout treatment. This new approach to the treatment of skeletal Class II malocclusion has the following characteristics . Independent of Patient cooperation. . Shorter treatment time due to the simultaneous retraction of the six anterior teeth . Early change of facial Profile motivating greater cooperation from patients These results indicate that the M.I.A. can be used as anchorage for orthodontic treatment. The use of M.I.A. with sliding mechanics in the treatment of skeletal Class II malocclusion increases the treatment simplicity and efficiency.

  • PDF

A study on treatment effects of Class III cases by second molar extraction (제 2 대구치 발거에 의한 III급 부정교합자의 치료효과에 관한 연구)

  • Lee, Sung-Hee;Park, Young-Guk;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.34 no.2 s.103
    • /
    • pp.109-119
    • /
    • 2004
  • This study aimed at investigating the skeletal, dentoalveolar, and soft tissue changes of Class III malocclusion cases treated by second molar extraction. The lateral cephalograms of 15 subjects with moderate Class III malocclusion by average ANB $-1.4^{\circ}\;and\;IMPA\;85^{\circ}$ were traced and the computerized superimposition of average craniofacial change was made. The data was gathered and statistically analyzed. The results were as follows: 1 Lower anterior facial height/anterior facial height increased by 0.6%(P<0.01), mandibular plane increased by $1.5^{\circ}$(P<0.05). 2. There was a slightly downward & backward rotation of the mandible. 3. Lower first molar tipped distally by 4.nm(P<0.001), lower anterior teeth lingually tipped by $3.2^{\circ}$(P<0.05). 4. Retracted lower lip improved facial profile. This study may suggest that second molar extraction could be effective for a moderate Class III malocclusion to make distalization of the lower first molar easier and avoid severe lingual tipping of the lower incisor, if the lower third molar has a normal shape, good direction of eruption and adequate time for lower second molar extraction

3D Model Retrieval Using Sliced Shape Image (단면 형상 영상을 이용한 3차원 모델 검색)

  • Park, Yu-Sin;Seo, Yung-Ho;Yun, Yong-In;Kwon, Jun-Sik;Choi, Jong-Soo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.6
    • /
    • pp.27-37
    • /
    • 2008
  • Applications of 3D data increase with advancement of multimedia technique and contents, and it is necessary to manage and to retrieve for 3D data efficiently. In this paper, we propose a new method using the sliced shape which extracts efficiently a feature description for shape-based retrieval of 3D models. Since the feature descriptor of 3D model should be invariant to translation, rotation and scale for its model, normalization of models requires for 3D model retrieval system. This paper uses principal component analysis(PCA) method in order to normalize all the models. The proposed algorithm finds a direction of each axis by the PCA and creates orthogonal n planes in each axis. These planes are orthogonalized with each axis, and are used to extract sliced shape image. Sliced shape image is the 2D plane created by intersecting at between 3D model and these planes. The proposed feature descriptor is a distribution of Euclidean distances from center point of sliced shape image to its outline. A performed evaluation is used for average of the normalize modified retrieval rank(ANMRR) with a standard evaluation from MPEG-7. In our experimental results, we demonstrate that the proposed method is an efficient 3D model retrieval.

Kinematical Analysis of Side Kick Motion in Taekwon Aerobics (태권에어로빅스 옆차기동작의 운동학적 분석)

  • Yoo, Sil
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.3
    • /
    • pp.33-42
    • /
    • 2008
  • The purpose of this study was to analyze kinematic variables during Side kick motion in Taekwon Aerobics. The subjects of this study were the 7 skilled and 7 unskilled female college students. A QTM and an Auto Track were used to acquire raw data. The sampling rates camera was 100 Hz. The parameters were calculated and analyzed with Visual3D and SPSS 12.0. The results were as following; 1. In the elapsed time, there was no significance difference statically between a skilled and unskilled group. 2. In the cases of knee angle, there was significant difference statically at Maximum Knee Flexion2(p=0.046, F=4.925). 3. In the cases of knee angular velocity, there was significant difference statically at Maximum Knee Flexion1(p=0.031, F=5.940). 4. In the flexion/extension of hip angle, there was significant difference statically at Maximum Knee Flexion2(p=0.012, F=8.668). 5. In the abduction/adduction of hip angular velocity, there was significant difference statically at Minimum Knee Flexion (p=0.019, F=7.324). 6. In the external rotation/internal rotation of hip angular velocity, there was significant difference statically Minimum Knee Flexion(p=0.005, F=11.87).

Structural and Optical Properties of Sol-gel Derived ZnO:Cu Films

  • Bae, Ji-Hwan;Park, Jun-Su;Jo, Sin-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.199-199
    • /
    • 2013
  • 최근 단파장 광전 소자와 고출력 고주파 전자 소자에 대한 수요 때문에 넓은 밴드갭 에너지를 갖는 반도체에 관심이 많다. 이중에서, ZnO는 우수한 화학 및 역학적 안정성, 수소 플라즈마 내구성과 저가 제조의 장점 때문에 광전자 소자 개발 분야에 적합한 산화물 투명 전극으로 관심을 끌고 있다. 불순물이 도핑되지 않은 ZnO는 본질적으로 산소 빈자리 (vacancy)와 아연 격자틈새 (interstitial)와 같은 자체의 결함으로 말미암아 n형의 극성을 갖기 때문에, 반도체 소자로 응용하기 위해서는 도핑 운반자의 농도와 전도성을 제어하는 것이 필요하다. 본 연구에서는 박막 제조시 제어성, 안정성과 용이하게 성장이 가능한 졸겔 (sol-gel) 방법을 사용하여 사파이어와 석영 기판 위에 Cu가 도핑된 ZnO 박막을 성장시켰으며, 그것의 구조, 표면 형상, 평균 투과율, 광학 밴드갭 에너지를 계산하였다. 특히, Cu의 몰 비를 0, 0.01, 0.03, 0.05, 0.07, 0.1 mol로 변화시키면서 ZnO:Cu 박막을 성장시켰다. ZnO:Cu 졸은 zinc acetate dihydrate, 2-methoxyethanol (용매), momoethanolamine (MEA, 안정제)을 사용하여 제조하였다. 상온에서 2-methoxyethanol과 MEA가 혼합된 용액에 zinc acetate dihydrate (Zn)을 용해시켰다. 이때 MEA와 Zn의 몰 비는 1로 유지하였다. 이 용액을 $60^{\circ}C$ 가열판 (hot plate)에서 24 h 동안 자석으로 휘젓으며 혼합하여 맑고 균일한 용액을 얻었다. 이 용액을 3000 rpm 속도로 회전하는 스핀 코터기의 상부에 장착된 사파이어와 석영 기판 위에 주사기 (syringe)를 사용하여 한 방울 떨어뜨려 30 s 동안 스핀한 다음에, 용매를 증발시키고 유기물 찌꺼기를 제거하기 위하여 $300^{\circ}C$에서 10분 동안 건조시킨다. 기판 위에 코팅하는 작업에서 부터 건조 작업까지를 10회 반복한 다음에, 1 h 동안 전기로에 장입하여 석영 기판 위에 증착된 시료는 $550^{\circ}C$에서, 사파이어 기판은 $700^{\circ}C$에서 열처리를 수행하였다. Cu의 몰 비 0, 0.01, 0.03, 0.05, 0.07, 1로 성장된 ZnO:Cu 박막에 대한 x선 회절 분석의 결과에 의하면, 모든 ZnO:Cu 박막의 경우에 관측된 34.3o의 피크는 ZnO (002) 면에서 발생된 회절 패턴을 나타낸다. 이것은 JCPDS #80-0075에 제시된 회절상과 일치하였으며, ZnO:Cu 박막이 기판에 수직인 c-축을 따라 우선 배향됨을 나타낸다. 사파이어 기판 위에 증착된 박막의 경우에, Cu의 몰 비가 점점 증가함에 따라(002)면 회절 피크의 세기는 전반적으로 증가하여 0.07 mol에서 최대를 나타내었으나, 석영 기판 위에 증착된 박막의 경우에는 0.05 mol에서 최대를 보였다. 외선-가시광 분광계를 사용하여 서로 다른 Cu의 몰 비로 성장된 ZnO:Cu 박막에서 광학 흡수율 (absorbance) 스펙트럼을 측정하였으며, 이 데이터를 사용하여 평균 투과율을 계산한 결과, 투과율은 Cu의 몰 비에 따라 현저한 차이를 나타내었다. Cu의 몰 비가 0.07 mol일 때 평균 투과율은 80%로 가장 높았으며, 0.03 mol에서는 30%로 최소이었다. 광학밴드갭 에너지는 Tauc 모델을 사용하여 계산하였고, 결정 입자의 형상과 크기와의 상관 관계를 조사하였다.

  • PDF

The Study of Auto Welding Machine for PCTC Lashing Socket (PCTC Lashing Socket 자동용접장치 개발에 관한 연구)

  • Park, Chan-Kyu;Yang, Jong-Su;Kim, Ho-Gyoung
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.6-6
    • /
    • 2009
  • 자동차 운반용 선박(PCTC) 건조 시, 자동차를 고정시키기 위해 약 5 만 여개의 Lashing Socket(6,700 Units PCTC 기준)이 소요되는데, 이때 사용되는 Lashing Socket 은 용도 및 형태에 따라 Hole Cup, Flush Cloverleaf Type Pot, Raised Cloverleaf Type Pot, D-Ring, Crinkle Bar 등으로 구분된다. 이와 같이 다양한 종류 중에서 Hole cup 타입이 전체 적용되는 Lashing Socket 의 약 80%에 이른다. 기존에 사용되고 있는 자동용접장치는 Hole Cup 이외에는 적용이 불가능하고, 자석을 이용하여 Hole Cup 의 상부에 위치시키는 방식이었기 때문에 경량화 및 다양한 종류 및 크기의 Lashing Socket 에 적용이 가능한 자동용접장비의 개발이 요구되었다. 본 연구에서는 두께가 다른 $\phi$140 Hole Cup 및 Flush Cloverleaf Type Pot, Raised Cloverleaf Type Pot 에 적용 가능하며, 분리형 용접캐리지와 Centering Template, Magnet Jig 로 구성된 연속 및 단속 용접이 가능한 자동용접장치를 연구 개발하였다. 이를 통해 종래 Hole Cup 전용 자동용접 캐리지의 문제점을 개선하여, 작업자가 Centering Template 과 Magnetic Jig 을 이용하여 캐리지를 Hole Cup 의 중앙에 위치시키기 용이하게 하였다. 이 같은 분리형 장치 구성을 통해 Hole Cup 중앙에 캐리지 고정 작업과 용접 작업을 분리함으로써 자동용접이 진행되는 도중에 여분의 Jig를 이용하여 다른 Hole Cup 에 용접 준비를 하여 연속적인 작업이 가능하도록 하였다. 본 연구는 종래의 Hole Cup 전용 자동용접 캐리지의 문제점을 개선한 분리형 용접 캐리지를 개발함으로써 아래와 같은 결과를 얻었다. 1. 용접 캐리지를 포함하여 각 부분별 분리를 통해 작업자가 1 회 이동 시 필요로 하는 중량을 감소시켜 장비의 이동 및 제어가 쉽다. 2. Magnetic Jig 를 Centering Template 에 결합하고, Template 의 Jig 를 Lashing Socket 에 결합함으로써 손쉽게 Lashing Socket 의 중심부를 찾을 수 있으므로 용접 캐리지의 정확한 센터 고정이 가능하다. 3. 엔코더에 의한 1 회전을 검출함으로써, 작업 종료 후, 어떤 위치에서나 작업 재개가 가능하며 원점 복귀 작업이 불필요하다. 또한 엔코더에 의한 거리 설정으로 용접 속도에 상관없이 동일한 거리만큼 오버랩 용접이 가능하다. 4 디지털 방식으로 용접 조건의 입력이 가능하고, 용접 조건을 D/B 화 함으로써 Control Panel 상에서의 자동 제어가 가능하다. 이를 통해 연속 용접 또는 단속 용접이 가능하므로 다양한 형태의 Lashing Socket 을 자동 용접할 수 있는 효과가 있다. 이상의 결과를 통해 본 장비가 Fig.2 의 3 가지 종류의 Lashing Socket 용접에 효과적인 장비임을 확인할 수 있었다.

  • PDF