• Title/Summary/Keyword: 회전계획

Search Result 261, Processing Time 0.027 seconds

Statistical Properties of Second Type Central Composite Designs (제2종의 중심합성계획의 통계적 성질)

  • Kim Hyuk-Joo;Park Sung-Hyun
    • The Korean Journal of Applied Statistics
    • /
    • v.19 no.2
    • /
    • pp.257-270
    • /
    • 2006
  • Kim(2002) proposed a second type of central composite design in which the positionsof the axial points are indicated by two numbers, and called it CCD2. In the present paper, we have studied CCD2 further and obtained several new facts. We have obtained CCD2's that have both orthogonality and rotatability, both orthogonality and slope rotatability, and both rotatability and uniform precision. We also have applied Park and Kim's (1992) measure of slope rotatability to such CCD2's and observed some useful results.

Optimal Ship Route Planning in Coastal Sea Considering Safety and Efficiency (안전과 효율을 고려한 연안 내 선박의 최적 항로 계획)

  • Lee, Won-Hee;Choi, Gwang-Hyeok;Ham, Seung-Ho;Kim, Tae-wan
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2019.05a
    • /
    • pp.38-39
    • /
    • 2019
  • Optimal route planning is the route planning to minimize voyage time or fuel consumption in a given ocean environment. Unlike the previous studies on weather routing, this study proposes an optimization method for the route planning to avoid the grounding risk in the coast. The route way-points were searched using Dijkstra algorithm, and then the optimization was performed to minimize fuel consumption by setting the optimization design parameter to the engine rpm. To set the engine rpm, a method to use the fixed rpm from the departure point to the destination point, and a method to use the rpm for each section by dividing the route were used. The ocean environmental factors considered for route planning were wind, wave, and current, and the depth information was utilized to compute grounding risk. The proposed method was applied to the ship passing between Mokpo and Jeju, and then it was confirmed that fuel consumption was reduced by comparing the optimum route and the past navigated route.

  • PDF

Development of Ideal Model Based Optimization Procedure with Heuristic Knowledge (정위적 방사선 수술에서의 이상표적모델과 경험적 지식을 활용한 수술계획 최적화 방법 개발)

  • 오승종;송주영;최경식;김문찬;이태규;서태석
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.84-93
    • /
    • 2004
  • Stereotactic radiosurgery (SRS) is a technique that delivers a high dose to a target legion and a low dose to a critical organ through only one or a few irradiations. For this purpose, many mathematical methods for optimization have been proposed. There are some limitations to using these methods: the long calculation time and difficulty in finding a unique solution due to different tumor shapes. In this study, many clinical target shapes were examined to find a typical pattern of tumor shapes from which some possible ideal geometrical shapes, such as spheres, cylinders, cones or a combination, are assumed to approximate real tumor shapes. Using the arrangement of multiple isocenters, optimum variables, such as isocenter positions or collimator size, were determined. A database was formed from these results. The optimization procedure consisted of the following steps: Any shape of tumor was first assumed to an ideal model through a geometry comparison algorithm, then optimum variables for ideal geometry chosen from the predetermined database, followed by a final adjustment of the optimum parameters using the real tumor shape. Although the result of applying the database to other patients was not superior to the result of optimization in each case, it can be acceptable as a plan starling point.

  • PDF

A Comparative Study on the Head and Neck Radiation Therapy for Dynamic Conformal Arc Therapy and Volumetric Modulated Arc Therapy (두경부 방사선 치료 시 입체조형동적회전조사치료와 용적변조회전조사치료에 관한 연구)

  • Kim, Deok-Ki;Choi, CheonWoong;Choi, Jae-hyock;Won, Hui-su;Park, Cheol-soo
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.6
    • /
    • pp.208-218
    • /
    • 2015
  • Recently, radiation therapy is used in the CT existing conventional two-dimensional radiation image, and set the size and location of the tumor in a manner that the image is going to change the treatment plan. After using the simulation using CT, radiation therapy it is four-dimensional or three-dimensional treatment made possible. and radiation therapy became the more effective ever before. High technology radiation therapy such as the treatment of SRS,IMRT, IGRT, SBRT, is a need to try contemplating the possibility to apply appropriate analysis and situation, so it has its own characteristics. and then it is believed that it is necessary to analyze and try it worries the proper applicability of the situation. The configuration of the various treatment that is applicable in many hospitals is necessary to try to determine how to practically apply the patients. Critical organs surrounding tumor give a small dose to avoid side effects and then the tumor has the therapeutic effect by providing a larger dose than before the radiation treatment.

Preliminary Study on Automated Path Generation and Tracking Simulation for an Unmanned Combine Harvester (자율주행 콤바인을 위한 포장 자동 경로생성 및 추종 시뮬레이션 기초연구)

  • Jeon, Chan-Woo;Kim, Hak-Jin;Han, XiongZhe;Kim, Jung-Hun
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.20-20
    • /
    • 2017
  • 궤도형 차량의 이동구조는 에너지 소비 측면에서 단점이 있지만 접지압의 감소로 인한 평지 및 야지험지에서도 원활한 주행이 가능한 장점으로 인해 농업분야의 플랫폼에서 많이 사용된다. 곡식을 베는 일과 탈곡하는 일을 한 번에 하는 콤바인도 이러한 무한궤도형 이동구조를 사용한다. 또한 궤도형 차량의 방향전환 및 주행속도 변환은 좌 우 궤도의 회전 속도를 다르게 하여 동시에 제어하기 때문에 정교한 주행 성능을 위해서는 궤도형 차량의 기구학 모델을 고려한 경로 계획이 필요하다. 본 연구에서는 직교형 포장에서 Round harvesting 기법 기반으로 궤도형 차량의 기구학 모델 및 포장정보를 고려한 자율주행 콤바인 경로계획 알고리즘을 개발하고자 하였다. 이를 위해 Labview 기반의 궤도형 차량 시뮬레이션을 구축하여 실제 포장정보를 이용해 생성 된 경로의 적용 가능성을 구명하고자 하였다. 자율주행 콤바인 경로 계획은 콤바인의 길이, 너비, 회전 시 좌 우 궤도의 속도 비, 직진 속도와 회전 속도 비, 회전 각도, 포장의 외부 경계선, 작업 겹침 량, 회경 횟수를 이용하여 좌현 새머리 선회를 포함한 내부 왕복작업 경로를 생성하며 외부 회경 횟수는 2~3회를 가정하였다. 자율주행 시뮬레이션은 차체와 궤도 자체의 미끄러짐과 작동기 지연시간을 단순화 한 궤도형 기구학 모델형태로 구성하였다. 추종 알고리즘은 선견 거리법을 사용하였으며, 측면 변이값과 방향 오차의 선형조합을 이용하여 조향변수를 정의하고 퍼지로직기반으로 좌 우 궤도 속도를 7 단계화하여 조향장치를 모델링하였다. 실험결과 개발 된 경로생성 알고리즘은 실제 취득 된 포장 외부 경계 GPS 위 경도를 이용해 자동으로 생성이 가능하며 간략화 된 콤바인 시뮬레이션에서 직진주행 RMS 위치 오차는 0.05 m, 선회구간에서 직진 구간 진입 시 RMS 위치 오차는 0.11 m, 직진 구간 RMSE 방향 오차는 3.2 deg로 콤바인 예취부 간격인 30 cm보다 작은 위치 오차를 보이며 생성된 경로 전체 추종이 가능함을 나타내었다.

  • PDF

Influence of Couch and Collimator on Dose Distribution of RapidArc Treatment Planning for Prostate Cancer in Radiation Therapy (치료테이블과 콜리메이터가 전립선암 래피드아크 치료계획의 선량분포에 미치는 영향)

  • Kim, Hyung-Dong;Kim, Byung-Young;Kim, Sung-Jin;Yun, Sang-Mo;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.99-105
    • /
    • 2012
  • We investigated the influence of photon energy, couch and collimator angle differences between arcs on dose distribution of RapidArc treatment planning for prostate cancer. RapidArc plans were created for 6 MV and 10 MV photons using 2 arcs coplanar and noncoplanar fields. The collimator angle differences between two arcs were $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, $75^{\circ}$ and $90^{\circ}$. The plans were optimized using same dose constrains for target and OAR (organ at risk). To evaluate the dose distribution, plans were analyzed using CI (conformity index), HI (homogeneity index), QOC (quality of coverage), etc. Photon energy, couch and collimator angle differences between arcs had a little influence on the target and OAR. The difference of dosimetric indices was less than 3.6% in the target and OAR. However, there was significant increase in the region exposed to low dose. The increase of V15% in the femur was 6.4% (left) and 5.5% (right) for the 6 MV treatment plan and 23.4% (left), 24.1% (right) for the noncoplanar plan. The increase of V10% in the Far Region distant from target was 54.2 cc for the 6 MV photon energy, 343.4 cc for the noncoplanar and 457.8 cc for the no collimator rotation between arcs.

Verification of Indicator Rotation Correction Function of a Treatment Planning Program for Stereotactic Radiosurgery (방사선수술치료계획 프로그램의 지시자 회전 오차 교정 기능 점검)

  • Chung, Hyun-Tai;Lee, Re-Na
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.47-51
    • /
    • 2008
  • Objective: This study analyzed errors due to rotation or tilt of the magnetic resonance (MR) imaging indicator during image acquisition for a stereotactic radiosurgery. The error correction procedure of a commercially available stereotactic neurosurgery treatment planning program has been verified. Materials and Methods: Software virtual phantoms were built with stereotactic images generated by a commercial programming language, Interactive Data Language (version 5.5). The thickness of an image slice was 0.5 mm, pixel size was $0.5{\times}0.5mm$, field of view was 256 mm, and image resolution was $512{\times}512$. The images were generated under the DICOM 3.0 standard in order to be used with Leksell GammaPlan$^{(R)}$. For the verification of the rotation error correction function of Leksell GammaPlan$^{(R)}$, 45 measurement points were arranged in five axial planes. On each axial plane, there were nine measurement points along a square of length 100 mm. The center of the square was located on the z-axis and a measurement point was on the z-axis, too. Five axial planes were placed at z=-50.0, -30.0, 0.0, 30.0, 50.0 mm, respectively. The virtual phantom was rotated by $3^{\circ}$ around one of x, y, and z-axis. It was also rotated by $3^{\circ}$ around two axes of x, y, and z-axis, and rotated by $3^{\circ}$ along all three axes. The errors in the position of rotated measurement points were measured with Leksell GammaPlan$^{(R)}$ and the correction function was verified. Results: The image registration errors of the virtual phantom images was $0.1{\pm}0.1mm$ and it was within the requirement of stereotactic images. The maximum theoretical errors in position of measurement points were 2.6 mm for a rotation around one axis, 3.7 mm for a rotation around two axes, and 4.5 mm for a rotation around three axes. The measured errors in position was $0.1{\pm}0.1mm$ for a rotation around single axis, $0.2{\pm}0.2mm$ for double and triple axes. These small errors verified that the rotation error correction function of Leksell GammaPlan$^{(R)}$ is working fine. Conclusion: A virtual phantom was built to verify software functions of stereotactic neurosurgery treatment planning program. The error correction function of a commercial treatment planning program worked within nominal error range. The virtual phantom of this study can be applied in many other fields to verify various functions of treatment planning programs.

대용량 회전기의 전기절연 진단 시험기술

  • 조연옥;류희석
    • 전기의세계
    • /
    • v.38 no.11
    • /
    • pp.11-20
    • /
    • 1989
  • 고압회전기의 고정자권선에는 열, 전기 및 기계적, 환경적 스트레스가 단독 또는 복합적으로 가해지며, 이러한 응력들은 기기의 크기, 정력, 동작상태 등에 따라서 변화된다. 따라서 주기적인 절연진단 시험을 통하여 절연상태를 평가하고 그 변화추이를 검토하여 잔여수명을 예측함으로써 보수 및 교체시기를 계획하여 절연파괴로 인한 대형사고를 예방하는 것이 가장 바람직하다. 본 논문에서는 대용량 회전기의 정지기간 동안 실시하는 진단시험 및 열화상태 판정법등에 관하여 서술하고자 한다.

  • PDF

Implementation and Evaluation of the Electron Arc Plan on a Commercial Treatment Planning System with a Pencil Beam Algorithm (Pencil Beam 알고리즘 기반의 상용 치료계획 시스템을 이용한 전자선 회전 치료 계획의 구현 및 정확도 평가)

  • Kang, Sei-Kwon;Park, So-Ah;Hwang, Tae-Jin;Cheong, Kwang-Ho;Lee, Me-Yeon;Kim, Kyoung-Ju;Oh, Do-Hoon;Bae, Hoon-Sik
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.304-310
    • /
    • 2010
  • Less execution of the electron arc treatment could in large part be attributed to the lack of an adequate planning system. Unlike most linear accelerators providing the electron arc mode, no commercial planning systems for the electron arc plan are available at this time. In this work, with the expectation that an easily accessible planning system could promote electron arc therapy, a commercial planning system was commissioned and evaluated for the electron arc plan. For the electron arc plan with use of a Varian 21-EX, Pinnacle3 (ver. 7.4f), with an electron pencil beam algorithm, was commissioned in which the arc consisted of multiple static fields with a fixed beam opening. Film dosimetry and point measurements were executed for the evaluation of the computation. Beam modeling was not satisfactory with the calculation of lateral profiles. Contrary to good agreement within 1% of the calculated and measured depth profiles, the calculated lateral profiles showed underestimation compared with measurements, such that the distance-to-agreement (DTA) was 5.1 mm at a 50% dose level for 6 MeV and 6.7 mm for 12 MeV with similar results for the measured depths. Point and film measurements for the humanoid phantom revealed that the delivered dose was more than the calculation by approximately 10%. The electron arc plan, based on the pencil beam algorithm, provides qualitative information for the dose distribution. Dose verification before the treatment should be mandatory.

Complete Coverage Path Planning for Cleaning robot (청소로봇의 전역 경로계획)

  • Nam, Sang-Hyun;Moon, Seung-Bin
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2002.11c
    • /
    • pp.2431-2434
    • /
    • 2002
  • 본 논문에서는 전체 영역 경로 계획인 CCPP(Complete Coverage Path Planning)를 이용해 전 청소 영역을 청소하는 방법을 나타내고 청소영역을 해석 하였다. 그리고, Template방법에 CD(Cell Decomposition)을 접목시킨 방법을 이용해 청소영역을 청소 후 재 경로계획으로 청소 안된 영역을 효율적으로 청소하는 방법을 연구하였다. 또한 청소기의 회전 및 직선 모션에 따른 청소 영역을 비교 해석해 최적 시간과 거리에 따른 경로 계획을 살펴보았다.

  • PDF