• Title/Summary/Keyword: 황화학

Search Result 329, Processing Time 0.027 seconds

Froth Flotation of Copper Ore from Jambi Deposit, Indonesia (인도네시아 잠비산 동광석의 부유선별 특성 연구)

  • Kim, Hak-Soon;Jeon, Ho-Seok;Kim, Byoung-Gon;Baek, Sang-Ho
    • Journal of the Mineralogical Society of Korea
    • /
    • v.23 no.3
    • /
    • pp.243-250
    • /
    • 2010
  • Froth flotation of complex copper ore from Indonesia Jambi mine has been carried out to produce high-grade Cu concentrate. Since the ore contained minor Cu sulfides in addition to major Cu carbonate (malachite), copper concentrate was recovered by two-stage process of flotation, which consisted of copper sulfide flotation using xanthate followed by copper oxide flotation using oleic acid. The copper sulfide concentrate of 57.5% Cu grade with 9.5% recovery was obtained by copper sulfide flotation under conditions of 300 g/t collector (1 : 1 mixture of xanthate series Aero Promoter 211 and Aero Promoter 242) and pH 6.0 pulp. In subsequent copper oxide flotation on sink products, the concentrate of 30.8% Cu grade with 92.1% recovery was obtained under the conditions of oleic acid 300 g/t, AF65 50 g/t, pH 8.0 and 2 times cleaning. The flotation techniques which can achieve a Cu grade of 36.1% and a recovery of 92.1% have been developed from the two-stage process of flotation.

A feasibility of coagulation as post-treatment of the anaerobic fluidized bed reactor (AFBR) treating domestic wastewater (도시하수 처리 혐기성 유동상 반응조의 후속공정으로서 화학응집의 가능성 평가)

  • Yang, Seung Yong;Bae, Jae Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.6
    • /
    • pp.623-634
    • /
    • 2014
  • This study examined a feasibility of coagulation as post-treatment to remove sulfide and phosphorus for the effluent of anaerobic fluidized bed reactor (AFBR) treating domestic wastewater. Removal efficiencies of sulfide, phosphorus and COD by coagulation were not affected by pH in the range of 5.9 to 7.2. Alkalinity requirement could be estimated by the amount of $Fe^{3+}$ to form $Fe(OH)_{3(S)}$ and to remove sulfide and phosphorus. At coagulant aid dosage of 2 mg/L, anionic polymer showed best results regarding size and settleability of flocs. Sulfide removal for the AFBR effluent at the $Fe^{3+}/S^{2-}$ ratio of 0.64, close to the theoretical value of 0.67 found with a synthetic wastewater, was only 75.2%. One of the reasons for this high $Fe^{3+}/S^{2-}$ ratio requirement is that the AFBR effluent contains sulfide, phosphorus, hydroxide and bicarbonate which can react with $Fe^{3+}$ competitively. Concentrations of sulfide and phosphorous reduced to below 0.1 and 0.5 mg/L, respectively, at the $Fe^{3+}/S^{2-}$ ratio of 2.0. Average effluent COD of 80 mg/L, mostly soluble COD, was obtained at the dosage 50 mg $Fe^{3+}/L$ ($Fe^{3+}/S^{2-}$ ratio of 2.0) with corresponding COD removal of 55%. For better removal of COD, soluble COD removal at the AFBR should be enhanced. Coagulation with $Fe^{3+}$ removed sulfide, phosphorus and COD simultaneously in the AFBR effluent, and thus could be an alternative process for the conventional wastewater treatment processes where relatively high quality effluent is not required.

The Performance Degradation of PEMFCs Fabricated with Different GDLs During Exposure to Simultaneous Sulfur Impurity Poisoning Condition (서로 다른 GDL을 이용한 고분자전해질 막 연료전지의 황불순물 복합피독에 의한 성능 저하)

  • Lee, Soo;Kim, Jae-Hyun;Jin, Seok-Hwan
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.146-151
    • /
    • 2013
  • This paper reveals the performance decrease and recovery of PEMFC when the contaminated fuel gas and air source with sulfur impurities such as hydrogen sulfide and sulfur dioxide were simultaneously introduced to anode and cathode, respectively. Three different GDLs were fabricated with different carbon black and activated carbon to prevent an introduction of sulfur compound impurities into MEA. components. The severity of $SO_2$ and $H_2S$ poisoning was depended on concentrations(3 ppm - 10 ppm) of sulfur impurities. Especially, cell performance degradation rate was rapid when MEA fabricated with CN-2 GDL because it had little porosity on GDL surface. Moreover, the cell performance can be recovered up to 90%-95% only with neat hydrogen and fresh air feeding.. Conclusively, MEA fabricated with porous CN-1 GDL showed the best cell performance and recovery efficiency during exposure to poisoning condition by simultaneous sulfur impurities.

Binary transition metal sulfides hierarchical multi-shelled hollow nanospheres with enhanced energy storage performance (향상된 에너지 저장 능력을 가진 이중 전이금속 황화물 계층적 중공 구조의 나노구)

  • Lee, Young Hun;Choi, Hyung Wook;Kim, Min Seob;Jeong, Dong In;Tiruneh, Sintayehu Nibret;Kang, Bong Kyun;Yoon, Dae Ho
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.28 no.3
    • /
    • pp.112-117
    • /
    • 2018
  • The metal alkoxide, CuCo-glycerate nanospheres (NSs), were successfully synthesized as Cu-Co bimetallic sulfides hierarchical multi-shelled hollow nanospheres ($CuCo_2S_4$ HMHNSs) through solvothermal synthesis. In this reaction mechanism, the solvothermal temperature and the amount of glycerol as a cosurfactant play significant role to optimize the morphology of CuCo-glycerate NSs. Furthermore, $CuCo_2S_4$ HMHNSs were obtained under optimized sulfurization reaction time of 10 h via anion exchange reaction between glycerate and sulfur ions. Finally, the structural and chemical compositions of CuCo-glycerate NSs and $CuCo_2S_4$ HMHNSs were confirmed through field emission scanning electron microscopy (FESEM), transmission electron microscope (TEM), X-ray diffraction (XRD) and electrochemical performances.

$N_2\;Fixation\;and\;H_2$ Production by a Phototrophic Bacterium, Chromatium sp. (광합성세균 Chromatium sp.의 질소고정과 수소생산)

  • ;Michiro Matsuyama
    • Journal of Aquaculture
    • /
    • v.10 no.1
    • /
    • pp.69-76
    • /
    • 1997
  • Chromatium sp., densely populated on the bacterial plate of Lake Kaiike throughout the seasons, possibly fix N2 and concurrently produce H2 N2 Fixation and H2 production by Chromatium sp. were performed under photoautotrophic growth condition, and of which rates were much higher and showed expontial growth phase. Bacterial plater samples from Lake Kaiike collected on July 27, 1994 were used to know the effect of the light or H2S on N2 fixation and H2 productin by the bacteria. At low light intensity (250 lux), low rates of N2 fixation and H2 production were detected after 18 hours. However, high rates of the production were observed under the condition of high light intensity (1000 lux). On the other hand, a very low rate of N2 fixation was observed without an addition of H2S, while the bacterial rapilly increased N2 fixation and H2 production after adding H2S and the highest rate was observed in case of adding 20mg H2S-S/$m\ell$ to the bacterial plates.

  • PDF

Isolation and Characterization of a New Hydrogen Sulfide-Oxidizing Bacterium Thiobacillus Sp. (황화수소 산화세균인 새로운 Thiobacillus sp.의 분리 및 특성)

  • Cha, Jin-Myeong;Lee, In-Hwa
    • Korean Journal of Microbiology
    • /
    • v.32 no.4
    • /
    • pp.252-257
    • /
    • 1994
  • A new hydrogen sulfide-oxidation bacterium, Thiobacillus sp. was isolated from waste coal mine water around Hawsun in Chunnam province. The isolate was motile gram-negative rod shape, formed spore and grew up to be aerobically facultative chemolithotroph by using energy released from the oxidation of reduced inorganic sulfur compounds. It could assimilate various kinds of organic compounds and grew well upon thiosulfate-supplemented basal medium. To the lelvel of 32 mM in thiosulfate concentration, thiosulfate in itself was utilized as energy source for growth. However, from those of the higher concentration than 32 mM, thiosulfate functioned specifically as the substrate inhibitor rather than as the energy source. It was found that the optimum thiosulfate concentration for growth was 32 mM. The G+C content of the DNA was 65.0 mol%. The isolate had 16 : 1 + 17$_{cyc}$, 16 : 0 as their major non-hydroxylated cellular fatty acids, 3-OH 12 : 0 as a hydroxylated fatty acid and also contained unidentified $C_{18}$ branched fatty acid. The ubiquinone system in the respiratory chain was Q-9. Based on the physiological and biochemical characteristics, the isolate was assigned to a novel species of the genus Thiobacillus sp. iw.

  • PDF

Characteristics of Sulfides Distribution and Formation in the Sediments of Seonakdong River (서낙동강 퇴적물 내 황화물의 분포 및 생성 특성)

  • Park, Seong-Yeol;Hwang, Kyung-Yup;Lee, Nam Joo;Yoon, Young-Sam;Lee, Sang-Ho;Kim, Il-Kyu;Yu, Kwon Kyu;Hwang, Inseong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.6
    • /
    • pp.843-853
    • /
    • 2009
  • The sediment samples were collected from Seonakdong River and were analyzed for sulfide species such Acid Volatile Sulfide(AVS) and Elemental Sulfur(ES) and Chromium Reducible Sulfide(CRS). Then characteristics of the formation of sulfide species were investigated for six selected samples. Finally the relationship between environmental factors and sulfate reducing rate(SRR) was investigated using two selected samples. Concentrations of AVS and CRS were relatively high, which suggests that organics input to the sediments has been continued until recently and that potential of heavy metals leaching from the sediments is low. SRR in the sediments was closely related to fraction of fine particles(silt+clay) and also to dissolved organic carbon content of the sediment(DOCsed). The dependences of environmental factors such as organic content, temperature, sulfate concentration on the SRR was relatively strong in the selected experiments conducted with the samples from Noksan gate and Daejeo gate samples. The environmental factor dependencies were stronger in the Noksan gate samples than in the Daejeo gate samples, which is probably due to higher surface area of the Noksan gate sediments.

Removal of heavy metal and Hydrogen sulfide/Nitrophenol using Mackban-stone (맥반석을 이용한 중금속과 악취물질/nitrophenol의 제거)

  • Quen, Zhe-Xue;Yin, Cheng-Ri;Jin, Yin-Shu;Seok, Mi-Soo;Lee, Sung-Taik
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.9 no.2
    • /
    • pp.45-51
    • /
    • 2001
  • Mackban-stone effectively removed heavy metals, such as Fe, Cu, Cd, and Zn, with best removal of Fe and Cu. And the removal of heavy merals related with ion exchange of Ca. Mackban-stone is also an efficient deodorant of hydrogen sulfide and ammonia and inhibited the growth of E coli. The degradation rare of 4-nitropheno1 by Nocardioides sp. PNP101 and 2,4-dinitrophenol by Strain CJ1 and Rhodococcus sp. DNP 505 are increased by Mackbane-srone.

  • PDF

Dyeing Properties of Sulfur Dye Using Nylon High Density Knitting Fabrics (황화염료를 이용한 고밀도 나일론 편성물의 염색성)

  • Chung, Myung-Hee;Cho, Ho-Hun
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.16 no.1
    • /
    • pp.117-123
    • /
    • 2014
  • This paper examined dyeing using sulfur dye with nylon and the characteristics of high gauge knitting for generating high functionality including light weight, wind resistance and elasticity using fine nylon threads. Yarn tension, stitch field and knitting speed of high and fine gauge knitting were measured. The influence of reducing agents on sulfur dye, optimum dyeing conditions and fastness features in nylon dyeing were analyzed. The analysis results are presented below. When nylon (Hyoseong, 40d/34f) and spandex (Hyoseong, 20d) for use as hosiery yarn were used to knit high gauge and flat weave, 44 gauge, the effective knitting conditions were a stitch field over 8.2cm in 1 course length, yarn tension of less than 5g and knitting speed below 18rpm. Nylon dyeing using sulfur dye showed effective results when a rongalite reducing agent was used at more than 10% o.w.f. and dyeing was maintained at $98^{\circ}C$ for 30 minutes. For dyeing nylon and spandex composite using sulfur dye, color fastness in washing, water, daylight and friction were higher than Class 4 or 5, which indicated a superior property. The analysis results verified that the existing problems in nylon dyeing could be solved by using sulfur dyes that don't use heavy metals due to superior fastness and therefore quality, high gauge nylon knit products could be produced.

  • PDF

A study on the Effect of SOB(Sulfur-Oxidizing Bacteria) Media on the Removal of Hydrogen Sulfide in Water of Septic Tank (SOB(Sulfur Oxidizing Bacteria) Media가 정화조의 수중황화수소 제거에 미치는 영향에 관한 연구)

  • Song, Homyeon;Cho, Jeongil;Kim, Taeksoo;Kwon, Sucheol;Yu, Hyeongsik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.59-67
    • /
    • 2013
  • The odor occurring in the sewage system induces the displeasure, the disgust such as the headache, the vomit, etc. and increases the spiritual stress and disturbs the pleasant life of residents. These odors occur mainly in the area of combined sewage system treatment, being created in the personal sewage treatment plant such as septic tank and are incoming to sewage pipes and emitted to the outside through the manhole and the receiver, etc.; and this causes odors to the people. The Hydrogen Sulfide, the Methyl Mercaptan, the Ammonia, etc. are materials causing the odor, the more serious issue of odor is occurring since the septic tank of degradation process is being applied. The primary cause of odor is the decomposition of human feces in the septic tanks and sewage disposal facilities. The purpose of this study is reduction of hydrogen sulfide using air supplying and SOB(Sulfur-Oxidizing Bacteria). As a result of this study of the air supply system and the SOB media equipment by air supply, in case the air is injected to SOB media compared to the injection of air only, the removal efficiency the hydrogen sulfide was average 3.4 times higher.