• Title/Summary/Keyword: 활성화응고시간

Search Result 14, Processing Time 0.033 seconds

Fixed Dose Regimen of Heparin Administration with Activated Coagulation Time During Cardiopulmonary Bypass (심폐바이패스시 활성응고시간을 이용한 헤파린 고정용량법)

  • 김원곤;박성식
    • Journal of Chest Surgery
    • /
    • v.31 no.9
    • /
    • pp.867-872
    • /
    • 1998
  • Background: The fixed dose regimen with activated coagulation time(ACT) is the most commonly employed method for determining the required dosage of heparin and protamine during cardiopulmonary bypass(CPB). Material and Method: We performed a prospective study on a fixed dose regimen for analyzing adequate dosages of heparin and protamine, the incidence of heparin resistance and heparin-induced thrombocyt openia, factors affecting ACT during CPB, and changes of ACT during aprotinin usage. 300 units/kg of heparin were administered to patients, and ACTs were measured after 5 mins. ACTs were checked at 10 mins and 30 mins after the onset of CPB, and then at 30 min intervals thereafter. If the measured ACT was under 400 secs, we added 100 units/kg of heparin. The heparin was reversed with 1 mg of protamine for each 100 units administered. If the measured ACT was longer than 130 secs 30 mins after protamine administration or if there was definitive evidence of a coagulation defect, we administered a further 0.5 mg/kg of protamine. Result: We studied 80 patients(50 adults and 30 children) who underwent open heart surgery(OHS) at Seoul National University Hospital. Preoperative ACT was 114.3${\pm}$19.3 secs in adults, and 119.5${\pm}$18.2 secs in children. There were no differences in preoperative ACT due to age, body weight, body surface area, or sex. The preoperative ACT was not influenced by a positive past history of OHS. Ten adults(20%) and 3 pediatric patients(10%) needed additional doses of heparin to maintain the ACT above 400 secs. Additional protamine administration was needed in 9 adults(18%) and 10 children(33%). Heparin resistance was found in only two adults. Heparin-induced thrombocytopenia was detected in 2 adults and 1 child. During CPB, ACT was prolonged. 12 adult patients received a low dose of aprotinin and showed longer celite activated ACT compared to the control group.The kaolin activated ACT showed a lower tendency than the celite activated ACT in aprotinin users. Conclusion: In conclusion, fixed dose regimen of heparin and protamine can be used without significant problems, but the incidence of need of additional dosage remains unsatisfactory.

  • PDF

Viscoelastic Coagulation Test Guided Therapy for a Strategy to Reduce Transfusions (수혈 감소 전략을 위한 점탄성 응고 검사법의 유용성)

  • Park, Sun Young
    • The Korean Journal of Blood Transfusion
    • /
    • v.29 no.3
    • /
    • pp.240-252
    • /
    • 2018
  • Viscoelastic coagulation tests provide simultaneous measurements of multiple aspects of whole-blood coagulation, including interactions between the plasma components and cellular components of the coagulation cascade. This can be carried out immediately using a point of care technique. Viscoelastic tests could predict the patient's outcome, including mortality, and detect coagulopathy more sensitively, resulted in reduced blood loss. The transfusion strategy based on the viscoelastic parameters rather than a conventional coagulation test has been shown to reduce the transfusion requirements. Although there are concerns about the reliability and accuracy of this method, viscoelastic tests, including ROTEM, would be a useful method to guide patient blood management strategies.

Experimental Endotoxin-Induced Disseminated Intravascular Coagulation in Rat Model (쥐 모델에 있어 내독소에 의한 실험적인 범발성 혈관내 응고증)

  • Seok- Cheol Choi;Jai-Young Kim;Jin-Bog Koh;Won-Jae Lee
    • Biomedical Science Letters
    • /
    • v.3 no.2
    • /
    • pp.83-88
    • /
    • 1997
  • In septic patients, disseminated intravascula. coagulation (DIC) occurs frequently and is a pathologic condition associated with a variety of critical illness. DIC may complicate the already complex clinical situations and contribute to the high mortality. Nevertheless, its pathogenic mechanisms are not completely elucidated. Present study was prospectively designed to understand the pathogenetic mechanisms involved in the development of DIC. 15 rats were subjected to study and according to the aim, they were divided into three groups: group I, control (not treated-endotoxin, n=5); group II (12 hours after endotoxin injection, n=5); group III (24 hours after endotoxin injection, n=5). Experimental DIC was induced in rats by a bolus injection of endotoxin (1mg/kg, E. coli serotype 055:B5). Blood was collected by direct puncture of the heart. Platelet count, fibrinogen and plasminogen concentration, antithrombin III, D-dimer and complement components (C3 and C4) were measured in all subjects. In group II and III, there were apparent signs of DIC, including thrombocytopenia, decreased fibrinogen (but increase in group III), reduced C3 and antithrombin III, and elevated D-dimer. These data indicated that endotoxin might induce the activation of several pathways such as coagulation, fibrinolytic and complement cascade, causing DIC and subsequent multiple organ failures. Ultimately, the increased knowledge of the various pathogenetic mechanisms of coagulation activation and fibrinolysis in endotoxin-induced DIC may have prophylactic or therapeutic implications.

  • PDF

Study on the Aging Behaviors of a Rapidly Solidified Al-Li-Zr Alloy by Differential Scanning Calorimetry (열분석 방법에 의한 급냉응고 Al-Li-Zr 합금의 시효거동 연구)

  • Hong, Yeong-Jun;Gang, Jeong-Yun;Kim, In-Bae;Lee, Sang-Rae
    • Korean Journal of Materials Research
    • /
    • v.5 no.4
    • /
    • pp.405-411
    • /
    • 1995
  • 급냉응고된 Al-3.51wt%Li-0.34wt%Zr 합금의 시효거동을 시차주사열량계(DSC)에 의한 열분석 방법으로 조사하였다. DSC에 의한 비열측정 결과 $\delta$’의 석출에 의한 발열반응과 $\delta$, $\beta$ 및 복합석출상의 석출에 의한 발열반응을 확인하였으며 $\delta$’ 및 $\delta$의 재고용에 의한 2개의 흡열반응을 확인하였다. 7$0^{\circ}C$ 저온시효시 $\delta$’의 석출에 의한 발열반응 이전에 흡열반응이 나타났으며 이것은 $\delta$’ 석출 이전에 $\delta$’ 전구생성물이 형성되었음을 의미한다. DSC 곡선상에 나타난 발열과 흡열곡선을 해석하여 얻은 $\delta$’상 석출과 재고용의 활성화에너지값은 각각 83KJ/mol과 98KJ/mol로서 Al-Li 2원계 및 Al-Li-Mg에 비해 높은 값을 나타내엇으며, 시효에 의한 강화가 일어나 DSC에 의한 비열변화 조사결과 나타난 $\delta$’상 석출 완료 시효조건점 (21$0^{\circ}C$, 1시간)에서 최고경도값(Hv 160)을 나타내었다.

  • PDF

The Effects of Heparin-Coated Circuit on the Total Amount of Heparin During Cardiopulmonary Bypass (심폐기 사용 중에 HCC가 총 Heparin사용량에 미치는 영향)

  • 이현우;이재웅;박철현;박국양
    • Journal of Chest Surgery
    • /
    • v.33 no.12
    • /
    • pp.954-958
    • /
    • 2000
  • 배경: 헤파린표면처리 도관(Heparin-coated circuit: HCC)이 도관과 혈액사이의 반응(Blood-marterial reaction)을 줄여주어서 보체활성화(complement activation), 백혈구활성화(leukocyte activation)와 사이토킨 분비(cytokinerelease)등을 감소시켜 준다. 그러나 HCC가 수술 후에 출혈 양을 줄여주고 헌혈 필요량을 감소시켜 준다는 임상적 효과에 대해서는 인정된 부분이 많으나 아직까지 그 기전은 대부분은 미지의 상태로 남아있는 것이 사실이다. 본 연구는 HCC를 사용한 군(Group H)과 사용하지 않은 군(Group C)간에 심폐기 사용기간(Pumptime), 활성화 응고시간(activated clotting time: ACT)과 헤파린 사용량을 비교 분석해 봄으로서 두 군간에 존재할 수 있는 헤파린 사용량을 비교 분석해 본으로서 두 군간에 존재할 수 있는 헤파린 사용량 차이에 대하여 알아보려고 하게되었다. 대상 및 방법: 본원에서 1999년 5월 1일부터 동년 12월 31일 사이에 연령이 16세 이상인 환자에서 HCC를 사용했던 16명(Group H)과 사용하지 않았던 19명(Group C)을 대상으로 하였다. 모든 환자에서 수술 전 체중, 신장, 체표면적, 심폐기 사용시간(pumptime), 수술 중 최저체온, 대동맥 차단시간(Aortic cross clamping time. ACC time), ACT, 헤파린 및 프로타민 사용 양 등을 조사하였다. 결과: 연구대상 환자의 연령, 체중, 신장, 체표면적, 대동맥차단 시간, 체온 등은 HCC를 사용한 군(H 군)과 사용하지 않은 군(C군)간에 의미 있는 차이가 없었다(p<0.05). 헤파린 공급 전, 공급 후 20분, 40분, 60분과 프로타민 공급 후 20분에 측정한 ACT는 두 군간에 의미 있는 차이가 없었다. 두 군간의 처음에 공급한 헤파린 양과 총 프로타민 사용량은 차이가 없었으나(p>0.05), 추가 공급한 헤파린 양(11$\pm$30 versus 67$\pm$49mg, p<0.05)과 총 헤파린 사용량(176$\pm$44 versus 239$\pm$70mg, p<0.05)은 H군에서 의미 있게 적게 나왔다. 두 군간에서 심폐기 사용시간에는 차이가 없었으면서 H군에서 약 38%정도의 헤파린을 적게 사용하였다. 결론: 결론적으로 HCC의 사용으로 심폐기 사용 시간과 상관없이 추가하는 헤파린 양을 줄임으로서 총 헤파린 사용량을 줄여 줄 수 있었으며 이것이 HCC의 임상적 효과를 나타나게 하는 하나의 요소로 작용할 수 있다고 생각된다.

  • PDF

Effects of the Dosing Regimen of Tissue-type Plasminogen Activator on Blood Coagulation System in Experimental Pulmonary Embolism (실험적 폐색전증에서 조직형플라스미노겐활성체의 투여방법이 혈액응고기전에 미치는 영향)

  • Chung, Hee-Soon;Kim, Ho-Joong;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.5
    • /
    • pp.474-482
    • /
    • 1993
  • Background: As a physiologic plasminogen activator, tissue-type plasminogen activator (t-PA) could induce effective thrombolysis in massive pulmonary embolism, without the risk of systemic hemorrhage. However, therapeutic doses of t-PA has been associated with systemic lytic state, and fibrin selectivity may be influenced by the dosing regimen of t-PA. To investigate the effects of duration of t-PA infusion on blood coagulation system, we performed this study. Method: In a canine model of pulmonary embolism, which was induced by injection of autologous blood clots, we administered equal doses of t-PA (1 mg/kg) over 15 minutes in $t-PA_{15}$ group, over 180 minutes in $t-PA_{180}$ group, and only saline in control group. Then serial blood samplings were made to check complete blood count, prothrombin time, activated partial thromboplastin time, thrombin time, fibrin, plasminogen, ${\alpha}_2$-antiplasmin, coagulation factor V and VIII, and fibrin(ogen) degradation products. Results: 1) In all 3 groups, complete blood count showed same changes. Hemoglobin, hematocrit and platelet count decreased, but WBC count increased. 2) Prothrombin time, activated partial thromboplastin time, and thrombin time were prolonged during 15-60 minutes after t-PA administration in $t-PA_{15}$ group, and from 30 minutes through 180 minutes after administration in $t-PA_{180}$ gorup. 3) Fibrin, ${\alpha}_2$-antiplasmin, and cogulation factor V and VIII decreased in both $t-PA_{15}$ and $t-PA_{180}$ group, but returned to basal levels earlier in $t-PA_{15}$ group. 4) Fibrin(ogen) degradation products increased after pulmonary embolism in all groups, and further increased in both $t-PA_{15}$ and $t-PA_{180}$ groups after t-PA infusion. But more pronounced increment was noted in $t-PA_{180}$ gorup. Conclusion: In pulmonary embolism, the shorter (15 minutes) infusion of t-PA would have less risk of systemic hemorrhage than the longer (180 minutes) infusion when the doses is equal. And, this suggests that manipulating the duration of t-PA infusion can reduce the risk of major bleeding.

  • PDF

Disinfection Effect of Film Cassettes by Ultraviolet Irradiation (자외선을 이용한 Film Cassette의 소독 효과)

  • Kweon, Dae-Cheol;Park, Peom
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.4
    • /
    • pp.425-432
    • /
    • 2001
  • A bacteria infection on film cassette contact surface was examined at the diagnostic radiology department. Studies have demonstrated a bactericidal effect of ultraviolet irradiation, and to assess the contamination level on film cassette contact surface as a predictor of patient prevent from nosocomial infection. The study showed that the laboratory result was identified non-pathologic and pathologic bacterial in the five different cassette size of the contact surface. Film cassettes were exposed to ultraviolet light for 1, 2 and 3 minutes. Ultraviolet light disinfection practices suitable for bacteria. The study concludes that presence of a bacterial infection will prevent a using antiseptic technique on film cassette contact surface. In conclusion, ultraviolet irradiate on film cassette over the surface more than 2 minutes. Ultraviolet dose of $1565 {\mu}W{\codt}s/cm^2$ Win in 30 second relative to ultraviolet dose in time.

  • PDF

Feature of cerebral infarction with tsutsugamushi disease (쯔쯔가무시병과 동반된 뇌경색의 특징)

  • Choi, Pahn Kyu;Kang, Hyun Goo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.178-184
    • /
    • 2017
  • This study was performed on 16 patients diagnosed with tsutsugamushi disease and cerebral infarction from January 2007 to December 2015. An acute cerebral infarction was diagnosed by brain MRI and MRA. Tsutsugamushi disease was diagnosed using a polymerase chain reaction. To distinguish the difference between the generalized cerebral infarction and infarction with tsutsugamushi disease, the blood pressure and body temperature were measured uponadmission. In general, the blood pressure increases during an acute cerebral infarction. Interestingly, in this study, 12 patients showed a systolic blood pressure less than 130 mmHg uponadmission. The location of the cerebral infarction and whether single or multiple cerebral infarction were examined. Thirteen patients had a cerebral infarction in anterior circulation and 3 patients developed in posterior circulation. To evaluate the coagulation disorders, prothrombin time (PT), activated partial thromboplastin time (aPTT), D-dimer, fibrinogen, fibrin degradation product (FDP). D-dimer, which is generally known to increase in an acute cerebral infarction, showed a significant increase in the 13 patients. Fibrin degradation products (FDP) showed a significant increase in 15 patients. The pathophysiological mechanism of tsutsugamushi disease is known as vasculitis, which may result in an endothelial cell injury and proliferation of the endothelial wall, which may lead to a cerebral infarction accompanied by coagulopathy. Without endothelial cell damage and proliferation, a vasospasm caused by vasculitis may cause vasoconstriction and cerebral infarction.

Comparison of the effectiveness of various neural network models applied to wind turbine condition diagnosis (풍력터빈 상태진단에 적용된 다양한 신경망 모델의 유효성 비교)

  • Manh-Tuan Ngo;Changhyun Kim;Minh-Chau Dinh;Minwon Park
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.28 no.5
    • /
    • pp.77-87
    • /
    • 2023
  • Wind turbines playing a critical role in renewable energy generation, accurately assessing their operational status is crucial for maximizing energy production and minimizing downtime. This study conducts a comparative analysis of different neural network models for wind turbine condition diagnosis, evaluating their effectiveness using a dataset containing sensor measurements and historical turbine data. The study utilized supervisory control and data acquisition data, collected from 2 MW doubly-fed induction generator-based wind turbine system (Model HQ2000), for the analysis. Various neural network models such as artificial neural network, long short-term memory, and recurrent neural network were built, considering factors like activation function and hidden layers. Symmetric mean absolute percentage error were used to evaluate the performance of the models. Based on the evaluation, conclusions were drawn regarding the relative effectiveness of the neural network models for wind turbine condition diagnosis. The research results guide model selection for wind turbine condition diagnosis, contributing to improved reliability and efficiency through advanced neural network-based techniques and identifying future research directions for further advancements.

A Study on the In-Vitro Test of Thrombogenesis in Centrifugal Biopump (원심성 바이오 펌프를 이용한 혈전 생성의 생체 외 검사에 관한 연구)

  • Na, Myung-Hoon;Kim, Won-Gon;Kim, Joo-Hyun;Kim, Mee-Hyung;Yu, Jae-Hyeon;Lim, Seung-Pyung;Lee, Young
    • Journal of Chest Surgery
    • /
    • v.32 no.10
    • /
    • pp.863-873
    • /
    • 1999
  • 배경: 혈전 생성은 심혈관계 삽입물이나 순환 보조장치의 발전에 있어서 중요한 문제이므로 이러한 장치들의 혈전성에 대한 평가는 필수적이다. 따라서 이러한 장치들의 혈전성 연구를 시행하기 위한 효과적인 생체 외 실험 방식이 개발되어 원심성 순환 펌프의 발전에 큰 도움이 되고 있으며, 최근 엄밀하게 혈액과 공기의 접촉을 차단하는 방식이 믿을 수 있는 생체 외 실험 방식으로 강조되고 있다. 본 논문에서는 모의 순환 회로를 이용하여 기존에 행해진 연구 방법 상의 공기 접촉에 따른 핼액 응고 기전의 활성화 여부를 알아보기 위하여 공기 접촉 여부에 따른 혈액 인자의 변화를 관찰하여 확인하고, 또한 회로 내에서 생성된 혈전을 생체 내에서 형성된 혈전과 비교 분석하여 이 모의 순환 회로를 이용한 생체 외 검사가 새로 고안된 심혈관계 장치들의 혈전성을 평가하는데 있어서 동물실험을 대신할 수 있다는 기존의 주장을 검증하고자 하였다. 연구재료 및 방법: 바이오펌프를 이용한 같은 모의 순환 회로 한 쌍을 준비하고 동일 개체에서 얻은 헤파린을 첨가한(1u/$m\ell$) 신선한 혈액을 공기와 접촉시키지 않도록 한 A-회로와 공기와 접촉시킨 B-회로에 충전시켜 실험을 동시에 진행하여 결과를 얻었으며 총 12번 시행하였다. 회로에 충전한 혈액의 activated clotting time(ACT)은 정상의 3~5배였으며 ACT가 정상 범위의 1.5배가되면 실험을 끝냈고, Hematocrit(HCT), 혈소판, 동맥혈가스분석(ABGA), factor Ⅷ, factor \ulcorner, 섬유소원, thromboxane B2(TXB2), free hemoglobin(fHb) 등을 측정하였다. 실험이 끝난 후 A-회로와 B-회로에서 얻은 각 검사를 평가하고 분석하였으며 생성된 혈전을 생체 내에서 생성된 혈전과 조직 검사로 비교하였다. 본 연구의 자료분석은 SPSS 통계 프로그램을 이용하였고 유의수준 0.05를 기준으로 유의도를 판단하였다. 결과: 정상 ACT는 186.9$\pm$20.5초(평균$\pm$표준편차)이었고, 헤파린을 넣은 초기 ACT는 982.2$\pm$165.5초이었으며, 실험시간은 보통 60분에서 180분 사이였다. HCT, fHb, 혈소판, TXB2, factor Ⅷ, factor \ulcorner, 섬유원소의 초기값은 35.5$\pm$3.2%, 12.4$\pm$6.5 mg/dL, 354$\pm$56($\times$103)/$\mu$L, 72.6$\pm$15.1 mg/dL, 29.3$\pm$1.2%, 137.9$\pm$42.1 mg/dL, 그리고 17.7$\pm$9.7%이었다. 공기 접촉에 따른 차이를 보았을 때 ACT(p=0.398), HCT(p=0.988), fHb(p=0.898), 혈소판 (p=0.904), TXB2(p=0.985), factor Ⅷ(p=0.872), factor \ulcorner(p=0.489), 섬유원소(p=0.973)으로 전 예에서 통계적 유의성이 없었다. 실험 후 양 군에서 생성된 혈전의 현미경 소견은 B-회로의 혈전에 여러 군데 공기 방울이 관찰되는 것 이외에 A-회로에서 생성된 혈전과 차이가 없었고, 생체에서 생성된 혈전과 비교했을 때 그 양상이 같았다. A-회로와 B-회로에서 생성된 혈전의 총 량은 8.4$\pm$3.7 mL와 9.4$\pm$3.1 mL로 통계상 유의성은 없었다. (p=0.624). 결론: 모의 순환 회로를 이용한 혈전성 평가를 위한 생체 외 실험에 있어서 공기와의 접촉 여부는 혈액 응고 기전의 활성화나 혈전 생성에 별다른 영향을 미치지 않는다. 모의 순환 회로에서 형성된 혈전과 문헌에 있는 인체 내에서 형성된 혈전을 비교한 결과 그 형태가 일치하므로 이 모의 순환회로를 이용한 실험이 동물실험을 대신할 수 있다고 판단된다.

  • PDF