Hwang, Tae Hyok;Wang, Tae Hyun;Cho, Hyung Lae;Kim, Keun Young
Journal of the Korean Arthroscopy Society
/
v.15
no.2
/
pp.92-98
/
2011
Purpose: We describe a all-arthroscopic technique for decompression of spinoglenoid ganglion cyst and present our clinical results for this procedure. Materials and Methods: From March 2006 to June 2009, eight patients (7 males, 1 female; mean age 40.6 years; range: 21~61) were included who underwent arthroscopic decompression of spinoglenoid ganglion cyst. The most common symptoms were vague shoulder pain and external rotation weakness, which lasted 6.4 months (range: 3~8) on average. Five of eight patients were noted abnormalities on electromyographic (EMG) examination to have suprascapular nerve neuropathy and magnetic resonance imaging (MRI) showed spinoglenoid ganglion cysts in all eight patients and the cyst size was 2.6 cm (range: 1.8~3.6). Labral pathology was identified intraoperatively in all patients and the cysts were decompressed by the posterosuperior capsulotomy under arthroscopic control and labral repair with suture anchors was performed in six patients. Results: The average clinical outcome scores including Constant and Murley, Simple shoulder test (SST) all improved significantly at the time of the final follow-up and there were no complications resulting from the procedures. All patients including the patients with abnormal EMG study recovered strength on isokinetic strength testing. Follow-up MRI scans were performed on all patients at a mean of 5.2 months postoperatively (range: 3~12) revealed complete resolution of the cysts and no evidence of recurrences were seen at an average of 18 months (range: 12~26) of follow-up. Conclusion: Arthroscopic decompression of spinoglenoid ganglion cyst effectively restores patient function and all patients in this study showed improvement in their postoperative MRI findings. Arthroscopic decompression is also useful in the appropriate treatment for labral pathology and may contribute to decreased risk of cyst recurrence.
Kim, Jung-Man;Koh, In-Jun;Lee, Dong-Yeob;Lee, Yoon-Min
Journal of the Korean Arthroscopy Society
/
v.13
no.1
/
pp.14-21
/
2009
Purpose: To investigate MRI findings of the repaired anterior cruciate ligament (ACL). Materials and Methods: Seventeen of arthroscopic ACL primary repair with sutures pull-out technique were followed for 21.4 months (range: 12 to 60 months). Stability was assessed with physical examination and KT-1000 arthrometer (MED metric, San Diego, CA) and postoperative MRI checked with time. The patients were divided into 2 groups according to the location of tear which was defined with the location of remained synovial sleeve. Group I (11 patients) comprised that the tear was located within proximal 1/3 of ACL substance and group II (6 patients) comprised below proximal 1/3. MRI findings of the repaired ACL were evaluated by its course, sharpness, thickness and signal intensity using 3 grade system and correlated with its location of tear. Results: In all cases, Lachman test and flexion-rotation drawer test were negative, pivot-shift test was less than grade 1 and the mean side-to-side difference by use of KT-1000 arthrometer was 1.4 mm (range: -1.0 to 2.5 mm). The overall continuity of the repaired ACL was well maintained in all cases. However, mild sagging was observed in 10 cases(58.8%), mild obscure contour in 6 cases (35.3%), increased thickness in 8 cases (47.1%) and slight increased signal intensity in 5 cases (29.5%). There was no statistical significance in all parameters between 2 groups. And a focal defect at the femoral attachment site in sagittal image was observed in 7 cases (41.2%) of all patients which comprised 2 cases (18.2%) of group I and 5 cases (83.3%) of group II. It was observed more frequently in group II with statistical significance (p=0.035). Conclusion: Some abnormal MRI findings such as mild sagged course, obscure contour, increased thickness and signal intensity, the focal defect at femoral attachment site could be observed even though the stability was well maintained clinically. We thought that the focal defect was affected by the location of tear of ACL.
Objectives: Moxibustion has been used for various post-stroke symptoms and has also been known to have effect on peripheral blood flow. This study investigated the effect of moxibustion on radial artery blood flow by Doppler ultrasound and on heart rate variability in post-stroke hemiplegia patients. Methods: Moxibustion was applied on the points of LI4, TE3, TE5 and LI11 on the affected side, and blood flow of the radial artery was measured using the Minimax-Doppler-K device. Blood flow velocity and pulsation index were analyzed before, during, and after moxibustion. Simultaneously LF, HF, and LF/HF as variables for HRV were measured by FM-150. Results: The mean value of blood flow velocity in all patients (n=23) showed significant increase between before and after moxibustion, but there was no significant difference in pulsation index and LF, HF, LF/HF ratio between before and after moxibustion. In Yin (n=9) and Yang (n=14) groups, both showed significant increase of blood flow velocity between before and after moxibustion, but there was no significant difference in pulsation index and LF, HF, LF/HF ratio between before and after moxibustion. In Deficiency (n=14) and Fullness (n=9) groups, only the Deficiency group showed significant increase of blood flow velocity between before and after moxibustion, while the Fullness group showed no significant difference in blood flow velocity between before and after moxibustion, and also there was no significant difference in pulsation index and LF, HF, LF/HF ratio between before and after moxibustion. Conclusions: This study suggests that moxibustion on LI4, TE3, TE5 and LI11 on the affected side of stroke patients increase the peripheral blood flow in the affected arm, which was most remarkable in those with Yin and Deficiency pattern.
Purpose: This study is to compare the clinical results of ACL reconstruction between three groups using hamstring tendon autograft, mixed and tibialis tendon allograft. Materials and Methods: Between August 2003 and August 2008, we analyzed 169 cases of ACL reconstruction, 66 cases used hamstring tendon autograft, 42 cases used mixed graft and 61 cases used tibialis tendon allograft, with a minimum follow-up of 12 months. For the clinical evaluation, we evaluated the Lysholm score, Telos stress test device and IKDC score. Results: The average side to side difference in Telos stress test decreased from $7.5{\pm}1.0$ mm to $1.6{\pm}1.0$ mm in autograft group, from $7.6{\pm}1.1$ mm to $1.4{\pm}1.1$ mm in mixed graft group and from $7.4{\pm}1.3$ mm to $2.5{\pm}1.3$ mm in allograft group. The average Lysholm knee score improved from 58.6 to 92.3 in autograft group, from 60.6 to 92.6 in mixed graft group and from 55.3 to 91.5 in allograft group. There was no significant difference between three groups in clinical results. At second look arthroscopy, tension of ligament and synovial coverage were good result in autograft and mixed graft than allograft group. Conclusion: All hamstring tendon autograft, mixed graft and tibialis tendon allograft groups showed satisfactory clinical results, with no significant difference in outcomes between the groups. Both hamstring tendon autograft and mixed graft showed good synovial coverage in second look arthroscopy. So mixed graft will be considered as good alternative in case of shorter or thin harvested hamstring tendon.
The Journal of Korean Orthopaedic Ultrasound Society
/
v.7
no.1
/
pp.1-6
/
2014
Purpose: In order to know the effectiveness of ultrasonographic examination in diagnosis and follow-up evaluation for the frozen shoulder, we compared those with contralateral side in initial and after steroid injection. Materials and Methods: For the 20 unilateral frozen shoulder from July 2012 to July 2013, ultrasonographic examination was tried using reference line 1 (CBT: distance from coracoid process to LHB tendon) and line 2 (CBG: distance from coracoid process to bicipital groove). We tried 1 time steroid injection and compared the improvement in gross motion and reference line with 2 month, 4 month, and 6 month's serial ultrasonographic examination. Results: The differences on CBT line between lesion side and normal side were -5.6 mm, -5.0 mm, and -4.3 mm in neutral (Neut), external rotation (ER) and internal rotation (IR), respectively. The differences on CBG line were -6.1 mm, -4.7 mm, and -5.0 mm respectively (p<0.05). The changes in the reference line after steroid injection were evaluated at 2 month (CBT: -4.8 mm, -3.5 mm, -2.6 mm / CBG: -4.7 mm, -4.0 mm, -3.6 mm), 4 month (CBT: -4.7 mm, -3.2 mm, -1.7 mm / CBG: -4.3 mm, -3.7 mm, -1.2 mm), and 6 month (CBT: -1.1 mm, -2.9 mm, -0.5 mm / CBG: -1.2 mm, -0.7 mm, -0.9 mm). The gross motion was improved at 4 month after injection, from elevation $108^{\circ}$, ER $32^{\circ}$, IR L5 in initial to $133^{\circ}$, $42^{\circ}$, L3 respectively (p<0.05). Pain improved from 7.5 in initial to 3.0 at 2 month on visual analog scale (VAS). Conclusion: The serial examination after steroid injection revealed that the delayed improvement on reference line (6 month) compared with pain (2 month) or gross motion (4 month). Dynamic ultrasonogram was useful in diagnosis and follow-up evaluation of frozen shoulder.
Journal of Society of Occupational Therapy for the Aged and Dementia
/
v.12
no.2
/
pp.87-95
/
2018
Objective : Vibration stimulators are easier to obtain in clinical settings than other treatment tools, and it is advantageous that the arm activation training can be performed passively. Despite the following advantages, recent studies on vibration sense have not been activated yet. The purpose of this study was to investigate the effect of vibration sensation on the hands of the affected upper limb on unilateral reduction of stroke patients. Method : Patients with unilateral neglect due to stroke were enrolled in this study for about 3 weeks from October 19, 2018 to November 7, The research design used ABA design among the single-subject experimental research design, and a total of 18 circuits (4 baseline, 6 intervention, 3 baseline regression) were performed once a day on weekdays Respectively. MMES-K was used to select the subjects. Line bisection test (LBT), Albert's test and Star Cancellation Test (SCT) were used as unilateral neglect test. For the analysis, the baseline and intervention period measurements were visually analyzed using graphs and mean values were used. Result : All three evaluations showed that the number of errors missed during the training period was lower than the baseline period, and this decrease remained after training. The error was reduced by an average of $2{\pm}1.2$ omissions and an average omissions of $0.6{\pm}0.5$ omitting an average of $4.5{\pm}1$ omissions in the line break test. As a result of the Albert test, the average error decreased by $22.5{\pm}1.9$ omissions and $8{\pm}7.3$ omissions and $0.3{\pm}0.5$ omissions, respectively. In the star clearance test, the average error decreased from $26{\pm}4.6$ to $21.8{\pm}1.7$ and $20{\pm}0$, respectively. Conclusion : In this study, vibrotactile stimulation therapy showed a continuous effect on improving unilateral neglect. Based on these findings, further research should be conducted in order to improve objectivity in future studies. Further research on various arbitration methods that maximize the effect of intervention will be needed.
Journal of the Korea Academia-Industrial cooperation Society
/
v.20
no.7
/
pp.228-235
/
2019
The purpose of this study was to investigate the effect of 6 weeks' accelerated rehabilitation with anti-gravity treadmill exercise on VAS, ROM, isokinetic myofunction, and dynamic stability after surgery of modified brostrom operation in chronic ankle instability patients. The subjects of this study were 12 chronic ankle instability patients who underwent modified Brostrom operation(MBO) by the same doctor. 6 weeks' accelerated rehabilitation program is scheduled to perform for 60min, everyday, and also anti-gravity program performed for 15~30min, everyday. The visual analog scale(VSA) and significantly decreased(p<.001) and ROM in all of dorsal flexion, plantar flexion, inversion and eversion significantly increased(p<.05) after 6 weeks' accelerated rehabilitation with anti-gravity treadmill exercise. Both inversion and eversion peak torque at $60^{\circ}/sec$(p<.001, p<.01) and at $180^{\circ}/sec$(p<.001) significantly increased after 6 weeks' accelerated rehabilitation with anti-gravity treadmill exercise respectively. In muscle defect, although inversion(p<.01) and eversion(p<.001) at $60^{\circ}/sec$ and inversion(p<.01) at $180^{\circ}/sec$ significantly decreased, eversion at $180^{\circ}/sec$ tended to decrease but did not change significantly after 6 weeks' accelerated rehabilitation with anti-gravity treadmill exercise. The dynamic stability significantly increased after 6 weeks' accelerated rehabilitation with anti-gravity treadmill exercise(p<.001). These results suggest that 6 weeks' accelerated rehabilitation with anti-gravity treadmill exercise has positive effect of VAS, ROM, isokinetic myofunction, and dynamic stability after surgery of modified brostrom operation in chronic ankle instability patients. Therefore, we consider that the accelerated rehabilitation with anti-gravity treadmill exercise, which is safely and fast method, has effect on more faster recovery of ankle stability, play ground and normal daily activities.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.