• Title/Summary/Keyword: 환자 선별

Search Result 357, Processing Time 0.025 seconds

Verification of Shielding Materials for Customized Block on Metal 3D Printing (금속 3D 프린팅을 통한 맞춤형 차폐블록 제작에 사용되는 차폐 재료 검증)

  • Kyung-Hwan, Jung;Dong-Hee, Han;Jang-Oh, Kim;Hyun-Joon, Choi;Cheol-Ha, Baek
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.25-30
    • /
    • 2023
  • As 3D printing technology is used in the medical field, interest in metal materials is increasing. The Department of Radiation Oncology uses a shielding block to shield the patient's normal tissue from unnecessary exposure during electron beam therapy. However, problems such as handling of heavy metal materials such as lead and cadmium, reproducibility according to skill level and uncertainty of arrangement have been reported. In this study, candidate materials that can be used for metal 3D printing are selected, and the physical properties and radiation dose of each material are analyzed to develop a customized shielding block that can be used in electron beam therapy. As candidate materials, aluminum alloy (d = 2.68 g/cm3), titanium alloy (d = 4.42 g/cm3), and cobalt chromium alloy (d = 8.3 g/cm3) were selected. The thickness of the 95% shielding rate point was derived using the Monte Carlo Simulation with the irradiation surface and 6, 9, 12, and 16 energies. As a result of the simulation, among the metal 3D printing materials, cobalt chromium alloy (d = 8.3 g/cm3) was similar to the existing shielding block (d = 9.4 g/cm3) in shielding thickness for each energy. In a follow-on study, it is necessary to evaluate the usefulness in clinical practice using customized shielding blocks made by metal 3D printing and to verify experiments through various radiation treatment plan conditions.

A Case of Anti-Sda Proven by Urine Neutralization Test (중화반응으로 증명된 Anti-Sda 1예)

  • Yun, Seung Gyu;Kim, Jang Su;Yang, Jin Hyuk;Yoon, Soo-Young;Lee, Chang Kyu;Lim, Chae Seung;Cho, Yunjung;Kim, Young Kee;Lee, Kap No
    • Laboratory Medicine Online
    • /
    • v.1 no.1
    • /
    • pp.64-66
    • /
    • 2011
  • Anti-Sda is of no clinical significance, because it rarely causes hemolytic transfusion reactions. Even when its presence is suspected during antibody screening test, further identification of the antibody is usually not performed. We experienced a case of anti-Sda in 73 yr-old male patient showing mixed field agglutination by microcolumn agglutination. Antibody specificity could not be identified by conventional antibody identification test, and it was proven to be anti-Sda by urine neutralization test. In spite of its little clinical significance, it may give incompatible crossmatching results reacting with Sda antigen, which occurs at a high frequency in general population. When incompatible crossmatch results arising from anti-Sda are suspected, the problem may be solved by using the urine-neutralized serum of in crossmatching test.

Correlation Analysis of Clinical Risk Factors and Atherosclerosis Diagnosed by Carotid Artery Ultrasonography (경동맥 초음파로 진단된 죽상동맥경화증과 위험인자의 관련성 분석)

  • Jee-Yeon Park;Sung-Hee Yang
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.465-472
    • /
    • 2023
  • In predicting vascular disease, this study attempted to identify changes in the carotid intima-media thickness in patients who underwent carotid artery ultrasonography and hematological tests and to find out the effect of risk factors on the expression of atherosclerotic plaque. A retrospective analysis was conducted on 469 healthy adults who visited the hospital for the purpose of medical examination and performed carotid artery ultrasonography. As a result, carotid intima-media thickness, age, body mass index, waist circumference, systolic blood pressure, total cholesterol, high-density lipoprotein cholesterol, low-density lipoprotein cholesterol and glucose were analyzed as significant predictors of atherosclerotic plaque (p<0.001). The risk ratio was calculated based on the cut off value of the risk factors of the atherosclerotic plaque determined through ROC curve analysis, followed by 8.06 times the carotid intima-media thickness, 7.53 times the age, 3.97 times the waist circumference and 2.02 times the glucose. Therefore, in this study it was possible to prepare a Korean standard for clinical risk factors that affect the presence of absence of atherosclerotic plaque and observation of carotid artery ultrasonography is thought to help diagnose or predict cardiovascular disease early.

A Clinical Study on the Relationship between Dental Implant and Systemic Disease (치과 임플란트와 전신질환과의 연관성에 관한 임상적 고찰)

  • Yang-Keum Han;Mi-Sook Yoon;Han-Hong Kim
    • Journal of Korean Dental Hygiene Science
    • /
    • v.6 no.2
    • /
    • pp.25-35
    • /
    • 2023
  • Background: In order to emphasize the importance of clinical dental hygienists-led dental hygiene management processes for those with systemic diseases, we tried to identify systemic diseases affecting dental implants based on clinical data. Methods: In order to identify systemic diseases affecting dental implants, literature review was conducted from March 1 to May 31, 2023, and the search period was for research papers published in domestic and foreign academic journals from January 2000 to December 2020. Domestic databases used for search use RISS, Nuri Media(DBpia), and Korea Academic Information (http://www.papersearch.net ; KISS), while overseas databases searched Pubmed for dental implant failures, implants, systemic diseases, and Dental implant and system disease. Results: The cumulative survival rate of implants averaged 94.3 percent and the failure rate was 5.7 percent. Clinical analysis of systemic diseases related to implants accounted for the highest frequency with 13 (100.0%), followed by 8 (61.5%) studies on high blood pressure and smoking, 7 (53.8%) cardiovascular diseases, and 5 (38.5%). In addition, liver disease, thyroid abnormalities, blood abnormalities, organ transplants and infectious diseases were confirmed. Conclusion: Since unregulated systemic diseases are a risk factor for implant failure, clinical dental hygienists should continue to maintain healthy oral conditions by sharing information with patients during periodic preventive dental hygiene management processes such as dental hygiene assessment.

Analyze dosimetry with and without shielding when amplifying scattered rays (산란선 증폭시 차폐체 유무에 따른 선량 분석)

  • Chang Ho Cho;Jeong Lae Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.819-825
    • /
    • 2024
  • The reason for recording dose data when using a diagnostic radiation source is to record and manage the dose to healthcare personnel and patients. The purpose of this study was to verify the difference in radiation dose when using diagnostic radiation generating devices and to inform users' awareness of dose reduction through measurement and analysis of dose in situations with and without shielding. The dose analysis of each equipment for two Korean C-arms and two German C-arms showed that the Korean FPD type C-arm had the highest dose value, followed by the German I.I type C-arm, German FPD type C-arm, Korean, and I.I type C-arm. The results of the dose analysis with and without shielding showed that the dose to the human phantom in a normal atmosphere increased by about 2 times due to scattered radiation, but the dose to the human phantom was reduced by about 5 times by wearing a shield (0.5mm/lead apron). More important than the management of radiation dose is the study of how to reduce exposure when using radiation, and since the radiation dose output from different equipment is different, it is necessary to provide dose information with and without shielding.

Immediate Reoperation for Failed Mitral Valve Repair (승모판막성형술 실패 직후에 시행한 재수술)

  • Baek, Man-Jong;Na, Chan-Young;Oh, Sam-Se;Kim, Woong-Han;Whang, Sung-Wook;Lee, Cheol;Chang, Yun-Hee;Jo, Won-Min;Kim, Jae-Hyun;Seo, Hong-Ju;Kim, Wook-Sung;Lee, Young-Tak;Park, Young-Kwan;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.36 no.12
    • /
    • pp.929-936
    • /
    • 2003
  • We analysed the surgical outcomes of immediate reoperations after mitral valve repair. Material and Method: Eighteen patients who underwent immediate reoperation for failed mitral valve repair from April 1995 through July 2001 were reviewed retrospectively. There were 13 female patients. The mitral valve disease was regurgitation (MR) in 12 patients, stenosis (MS) in 3, and mixed lesion in 3. The etiologies of the valve disease were rheumatic in 9 patients, degenerative in 8, and endocarditis in 1. The causes of reoperation was residual MR in 13 patients, residual MS in 4, and rupture of left ventricle in 1. Fourteen patients had rerepair for residual mitral lesions (77.8%) and four underwent replacement. Result: There was no early death. After mean follow-vp of 33 months, there was one late death. Echocardiography revealed no or grade 1 of MR (64.3%) in 9 patients and no or mild MS in 11 patients (78,6%). Reoperation was done in one patient. The cumulative survival and freedom from valve-related reoperation at 6 years were 94% and 90%, respectively. The cumulative freedom from recurrent MR and MS at 4 years were 56% and 44%, respectively. Conclusion: This study suggests that immediate reoperation for failed mitral valve repair offers good early and intermediate survival, and mitral valve rerepair can be successfully performed in most of patients. However, because mitral rerepair have high failure rate, especially in rheumatic valve disease, adequate selections of valvuloplasty technique and indication are important to reduce the failure rate of mitral rerepair.

Analysis of Quantitative Indices in Tl-201 Myocardial Perfusion SPECT: Comparison of 4DM, QPS, and ECT Program (Tl-201 심근 관류 SPECT에서 4DM, QPS, ECT 프로그램의 정량적 지표 비교 분석)

  • Lee, Dong-Hun;Shim, Dong-Oh;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.67-75
    • /
    • 2009
  • Purpose: As to the analytical method of data, the various programs in which it is used for the quantitative rating of the Tl-201 myocardial perfusion SPECT are reported that there is a difference. Therefore, the measured value error of the mutual program is expected to be generated even if the quantitative analysis is made against data of the same patient. Using quantitative index that able to represent myocardial perfusion defect level, we aimed to determine correlation among three myocardial perfusion analysis programs 4DM (4DMSPECT), QPS (Quantitative Perfusion SPECT), ECT (Emory Cardiac Toolbox) that be used generally in most departments of Nuclear Medicine. Materials and Methods: We analyzed the 145 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Mediacal Center from December 1th 2008 to February 14th 2008. We sorted as normal group and abnormal group. Normal group consist of 80 patients (Male/Female=38/42, age:$65.1{\pm}9.9$) who have low possibility of cardiovascular disease. And abnormal group consist of 65 patients (Male/Female=45/20, age:$63.0{\pm}8.7$) who were diagnosed cardiovascular disease with reversible perfusion defect or fixed perfusion defect through myocardial perfusion SPECT results. Using the 4DM, QPS, and ECT programs, the total defect extent (TDE) such as LAD, LCX, RCA and the summed stress score (SSS) have been analysed for their correlations and statistical comparison with the paried t-test for the quantitative indices analysed from each group. Results: The correlation of 4DM:QPS, QPS:ECT, ECT:4DM each group result from 145 patients is 0.84, 0.86, 0.82 at SSS, 0.87, 0.84, 0.87 at TDE, and both index showed good correlation. In paired t-test and Bland-Altman analysis results showed no statistically significant difference in the comparison of QPS:ECT at the mean SSS and TDE, 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index. The correlation of 4DM:QPS, QPS:ECT, ECT:4DM program results from abnormal group (65 patients) is 0.72, 0.72, 0.70 at SSS and 0.77, 0.70, 0.77 at TDE and TDE and SSS has a good correlation. In abnormal group, paired t-test and Bland-Altman analysis results showed no statistically significant difference at QPS:ECT SSS (p=0.89) and TDE (p=0.23) comparison, 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index (p<0.01). In normal group (80 patients), paired t-test and Bland-Altman analysis results showed no statistically significant difference at QPS:ECT SSS (p=0.95) and TDE (p=0.73) comparison. And 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index (p<0.01). Conclusions: The perfusion defect of the Tl-201 myocardial perfusion SPECT was analyzed in not only the patient in whom it has the cardiovascular disease but also the patient in whom the possibility of the cardiovascular disease is few. In the comparison of the all group research, the mean of the TDE and SSS, 4DM was lower than QPS and ECT progrms. Each program showed good correlation and the results showed statistically significant difference. However, in this way, it is determined to be compatible about the analysis value in which the large-scale side between the programs uses each program a difference in a clinical in the Bland-Altman analyzed result in spite of the good correlation and cannot use. but, this analyzed result will be able to be usefully used as the reference material for the clinical read and is expected.

  • PDF

Usefulness Evaluation of Artifacts by Bone Cement of Percutaneous Vertebroplasty Performed Patients and CT Correction Method in Spine SPECT/CT Examinations (척추 뼈 SPECT/CT검사에서 경피적 척추성형술 시행 환자의 골 시멘트로 인한 인공물과 CT보정방법의 유용성 평가)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.49-61
    • /
    • 2014
  • Purpose: With the aging of the population, the attack rate of osteoporotic vertebral compression fracture is in the increasing trend, and percutaneous vertebroplasty (PVP) is the most commonly performed standardized treatment. Although there is a research report of the excellence of usefulness of the SPECT/CT examination in terns of the exact diagnosis before and after the procedure, the bone cement material used in the procedure influences the image quality by forming an artifact in the CT image. Therefore, the objective of the research lies on evaluating the effect the bone cement gives to a SPECT/CT image. Materials and Methods: The images were acquired by inserting a model cement to each cylinder, after setting the background (3.6 kBq/mL), hot cylinder (29.6 kBq/mL) and cold cylinder (water) to the NEMA-1994 phantom. It was reconstructed with Astonish (Iterative: 4 Subset: 16), and non attenuation correction (NAC), attenuation correction (AC+SC-) and attenuation and scatter correction (AC+SC+) were used for the CT correction method. The mean count by each correction method and the count change ratio by the existence of the cement material were compared and the contrast recovery coefficient (CRC) was obtained. Additionally, the bone/soft tissue ratio (B/S ratio) was obtained after measuring the mean count of the 4 places including the soft tissue(spine erector muscle) after dividing the vertebral body into fracture region, normal region and cement by selecting the 20 patients those have performed PVP from the 107 patients diagnosed of compression fracture. Results: The mean count by the existence of a cement material showed the rate of increase of 12.4%, 6.5%, 1.5% at the hot cylinder of the phantom by NAC, AC+SC- and AC+SC+ when cement existed, 75.2%, 85.4%, 102.9% at the cold cylinder, 13.6%, 18.2%, 9.1% at the background, 33.1%, 41.4%, 63.5% at the fracture region of the clinical image, 53.1%, 61.6%, 67.7% at the normal region and 10.0%, 4.7%, 3.6% at the soft tissue. Meanwhile, a relative count reduction could be verified at the cement adjacent part at the inside of the cylinder, and the phantom image on the lesion and the count increase ratio of the clinical image showed a contrary phase. CRC implying the contrast ratio and B/S ratio was improved in the order of NAC, AC+SC-, AC+SC+, and was constant without a big change in the cold cylinder of the phantom. AC+SC- for the quantitative count, and AC+SC+ for the contrast ratio was analyzed to be the highest. Conclusion: It is considered to be useful in a clinical diagnosis if the application of AC+SC+ that improves the contrast ratio is combined, as it increases the noise count of the soft tissue and the scatter region as well along with the effect of the bone cement in contrast to the fact that the use of AC+SC- in the spine SPECT/CT examination of a PVP performed patient drastically increases the image count and enables a high density of image of the lesion(fracture).

  • PDF

Study on Development of Acute Index Through Peripheral Blood Test in Total Body Irradiation Patients (방사선 전신조사 환자의 말초혈액 검사를 통한 급성장애 지표개발에 관한 연구)

  • Park, Young-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.13 no.1
    • /
    • pp.91-103
    • /
    • 2001
  • In those patients who underwent radiation therapy with 10 MV X-ray for bone marrow transfer, compared the effect of high dose irradiation on peripheral blood were investigated in randomly selecting 18 patients. thus, changes in the levels of peripheral blood (WBC, Seg. neutrophil, Lymphocyte, RBC, Hemoglobin, Hematocrit ratio, GOT, GPT) were observed for 25 days after irradiation with the peripheral blood levels before irradiation in these patients and in 32 controls. Among changes in peripheral blood, the level of WBC was $8.63\%$ after radiation therapy with as much decrease as $0.22{\times}103{\pm}0.19{\times}103/mm^3$ compared with $2.51{\times}103{\pm}1.29{\times}103/mm^3$ before radiation therapy, and was only $6.35\%$ of $7.17{\times}103/mm^3{\pm}1.46{\times}103/mm^3$ in the controls, showing statistical significance (P<0.01, r2=0.9151). In the morphologic test of WBC, the level of Seg. neutrophil was decreased as much as to $20.53\%$ with $14.17{\pm}21.60\%$ compared with $69.00{\pm}25.60\%$ before irradiation, and decreased down to $24.39\%$ compared with $58.09{\pm}7.62\%$ in the controls (P<0.05, r2=0.6316). The number of lymphocyte increased as much as 3.94 folds at $79.91{\pm}27.30\%$ compared with $20.29{\pm}21.15\%$ before irradiation and was 2.39 times higher than $33.46{\pm}6.79\%$ in the controls (P<0.05, r2=0.7337). Although the change in the number of RBC was little with $3.18{\times}106{\pm}0.41{\times}106/mm^3$ before irradiation and $4.66{\times}106{\pm}0.43{\times}106/mm^3$ in the controls, no statistical significance was present (P>0.05). In addition, The number of hemoglobin was low compared with before irradiation and with the controls, but none showed statistical significance (P>0.05). Similarly, although the hematocrit ratio was low compared with before irradiation and with the controls, no statistical significance was present (P>0.05). In the values of the histologic examinations GOT and GPT, there is statistical significance between those from with before irradiation and with the controls (P<0.05). Thus, among peripheral blood, the number of WBC decreased drastically for a certain period after total body irradiation with high dose radiation, and the levels of Seg. neutriphil and lymphocyte decreased significantly after irradiation in the lymphocyte morphologic test. The results of the present study suggest that the possibility of developing the first to determine initially those patients who might develop radiation acute impairment using the usual peripheral blood test of patients to be exposed to high dose irradiation.

  • PDF

The Cumulative Recurrence Rate of Colonic Adenomatous Polyps After Colon Polypectomy in a Single University Hospital Health Check-up Examinees (일개 대학병원 건강검진 수진자를 대상으로 한 선종성 대장용종절제술 후 대장용종의 누적재발률)

  • Hwang, Hye-Lim;Jung, Woo-Geun;Kim, Yun-Jin;Lee, Sang-Yeoup;Cho, Byung-Mann;Yi, Yu-Hyeon;Cho, Young-Hye;Tak, Young-Jin;Jeong, Dong-Wook;Lee, Jeong-Gyu
    • Journal of agricultural medicine and community health
    • /
    • v.39 no.3
    • /
    • pp.137-145
    • /
    • 2014
  • Objectives: Colonoscopy is a popular tool for screening for colon cancer throughout the world. The incidence of polypectomy and follow-up colonoscopy are persistently increasing but the studies about follow-up test after polypectomy are still lack of its domestic sources. This study is designed to look into the recurrence rate of colon polyps and risk factors after polypectomy. Methods: This is a retrospective study by reviewing medical charts of 147 patients who underwent polypectomy and follow-up colonoscopy from Jan. 2000 to Mar. 2008. The Kudo classification was used to describe the polyps found in the colonoscopy. The follow-up period was defined as the term between polypectomy and the first colonoscopy follow up. Results: Seventy six point two percent of the enrolled patient were male and the mean age was $56.5{\pm}8.1$. Mean follow-up period was $24.9{\pm}13.7$ (6 - 65) months. The cumulative recurrence rate of 1 year was 11.6%. The rate of 2 years was 36.7% and that of 3 years was 55.8%. The number of polyps was the factor which statistically showed significant relation of its recurrence rate. The histological morphology characteristic of polyps could be one independent factor which may be associated to the recurrence of polyps. Conclusions: The importance of colonoscopy follow up after polypectomy was clearly emphasized through the cumulative recurrence rate of 55.8%. Therefore, there is a need for more domestic studies with a large number of patients about the recurrence of polyps after polypectomy.