• Title/Summary/Keyword: 환자 선량

Search Result 1,412, Processing Time 0.029 seconds

CdZnTe Detector for Computed Tomography based on Weighting Potential (가중 퍼텐셜에 기초한 CT용 CdZnTe 소자 설계)

  • Lim, Hyunjong;Park, Chansun;Kim, Jungsu;Kim, Jungmin;Choi, Jonghak;Kim, KiHyun
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.35-42
    • /
    • 2016
  • Room-temperature operating CdZnTe(CZT) material is an innovative radiation detector which could reduce the patient dose to one-tenth level of conventional CT (Computed Tomography) and mammography system. The pixel and pixel pitch in the imaging device determine the conversion efficiency of incident X-or gamma-ray and the cross-talk of signal, that is, image quality of detector system. The weighting potential is the virtual potential determined by the position and geometry of electrode. The weighting potential obtained by computer-based simulation in solving Poisson equation with proper boundaries condition. The pixel was optimized by considering the CIE (charge induced efficiency) and the signal cross-talk in CT detector system. The pixel pitch was 1-mm and the detector thickness was 2-mm in the simulation. The optimized pixel size and inter-pixel distance for maximizing the CIE and minimizing the signal cross-talk is about $750{\mu}m$ and $125{\mu}m$, respectively.

Effects of Heat Treatment on the Antigenicity of Gamma-Irradiated Egg White Albumin (감마선 조사된 난백 알부민의 항원성에 미치는 가열의 영향)

  • 이주운;육홍선;조경환;김미리;김천제
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.5
    • /
    • pp.848-853
    • /
    • 2001
  • This research was conducted to study the effects on antigenicities (allergenicity) and structural changes of gamma-irradiated hen’s egg albumin (ovalbumin, OVA) by heating. Three groups of OVA solution (2.0 mg/mL) were prepared; 1) heat treatment; 2) irradiation after heating; 3) heating after irradiation. Samples were isothermally heated and/or irradiated at the absorption dose of 10 kGy. Competitive indirect ELISA was individually formatted with egg-allergic patients IgE (P-IgE), and mouse murine monoclonal IgG (M-IgG) and rabbit polyclonal IgG (R-IgG) for evaluating bindinhg abilities of antibodies to OVA in the sample solutions. Binding abilities of antibodies to thermally denatured OVA were changed : R-IgG to the sample treated with above 6$0^{\circ}C$, M-IgG to that above 7$0^{\circ}C$, and P-IgE to that above 8$0^{\circ}C$, respectively. P-IgE did not well recognize OVA heated at 8$0^{\circ}C$ and the above. However, binding abilities of M-IgG and R-IgG highly in creased. Significant differences of binding abilities were not observed in all samples with the combination of heat treatment and irradiation, regardless the order of the treatment. Turbidity of samples in creased both by heating and by irradiation, and the increase by irradiation was much higher than by heating. These results showed that allergenicity of OVA reduced by gamma irradiation was not affected by heating.

  • PDF

An overview of the regulatory effect of vitamin D supplementation on atopic dermatitis (비타민 D의 기능성: 아토피피부염의 조절에 미치는 영향 연구)

  • Sung, Dong Eun
    • Korean Journal of Food Science and Technology
    • /
    • v.53 no.2
    • /
    • pp.139-148
    • /
    • 2021
  • Atopic dermatitis is a chronic, recurrent, inflammatory skin disease that is a well-known allergic disease with severe itching, making daily life difficult. Since the immunomodulatory action of vitamin D has been reported, several researchers have attempted to determine the correlation between vitamin D and atopic dermatitis. In this review, 41 articles meeting the inclusion criteria were selected and reviewed from the articles published to date. Several studies have reported that low vitamin D levels are associated with the onset of atopic dermatitis and severe atopic dermatitis, but the opinions remain conflicting. Similarly, there are conflicting opinions on the improvement effect of oral vitamin D supplementation on atopic dermatitis, but some possibilities have been suggested. To apply vitamin D as a therapeutic agent for atopic dermatitis, a more systematically designed experiment should be conducted, and an appropriate intake dose for an immunomodulatory function should be obtained.

A Study of the CT MAR using Single-Source and Dual-Source Devices: Practical Comparison using Animal Phantom Fabrication (단일 선원 장치와 이중 선원 장치 비교를 이용한 전산화단층촬영 금속인공물 감소에 대한 연구: 동물팬텀 제작을 이용한 실측적인 비교)

  • Goo, EunHoe
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.1003-1011
    • /
    • 2020
  • This study aims to compare and evaluate the image differences between single and dual sources in applying a technique to reduce metal artifacts using dual energy CT. Discovery CT 256 (GE, USA) as a single source device and Somatom Definition Flash (Siemens Health Care, Forchheim, Germany) as a dual source device. The self-made phantom (pigs with medical titanium screws inserted) was quantitative and qualitatively evaluated under the same conditions by varying the dose under the same conditions using a dual energy CT. The evaluation method was compared by measuring SNR for metal artifacts (scattering, stripe) generated by metal inserts, divided around bones and around tissues. There was a difference in images in the method of reducing metal artifacts between single-source and dual-source devices. In a single source device, the linearized prosthesis by metal implantation showed a greater decrease than the image obtained from a double source device, and the surrounding tissue was well observed without interference from the artifact. In dual-source devices, scattering and stripe artifacts caused by metal inserts decreased more than on a single source device, and signals from adjacent tissues surrounding the metal implant were well observed without diminishing. If the examination is conducted separately between single source and dual source devices depending on whether the area to which the patient is intended to be viewed during the examination is adjacent to the metal insert or the total tissue surrounding the metal insert, it is believed that diagnostic helpful images can be obtained.

Quality Control of Dose Calibrator using 3D Printery (3D 프린터를 이용한 Dose Calibrator의 품질관리)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.307-312
    • /
    • 2021
  • In nuclear medicine, radioactive isotope tracers are administered to the human body to obtain and evaluate disease morphological information and biological function information. Dose calibrator is a device used to measure the radioactivity of a single nuclide in medical institutions. Administration of the correct dose to the human body acts as an important factor in diagnosis and treatment, and measurement through a dose calibrator before administration is the most important factor. Dose calibrator performs daily quality control after installation in each medical institution. Quality control is a means of guaranteeing quality control after installation, and is essential for improving the quality of treatment and promoting patient safety. Therefore, accurate and standardized performance evaluation methods should be established. In this study, 3D printing was used for quantitative evaluation of quality control by increasing the accuracy and standardization of quality control. When the 3D printer was installed and reproducibility was tested, the error range of the expected value and reading value decreased by 0.302% in the F-18 nuclide and 0.09% in the 99mTc-pertechnate nuclide than when the 3D printer was installed. The error rate for other nuclides was also found to have a low error rate for reproducibility tests when 3D printing was installed.

Verification of Shielding Materials for Customized Block on Metal 3D Printing (금속 3D 프린팅을 통한 맞춤형 차폐블록 제작에 사용되는 차폐 재료 검증)

  • Kyung-Hwan, Jung;Dong-Hee, Han;Jang-Oh, Kim;Hyun-Joon, Choi;Cheol-Ha, Baek
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.25-30
    • /
    • 2023
  • As 3D printing technology is used in the medical field, interest in metal materials is increasing. The Department of Radiation Oncology uses a shielding block to shield the patient's normal tissue from unnecessary exposure during electron beam therapy. However, problems such as handling of heavy metal materials such as lead and cadmium, reproducibility according to skill level and uncertainty of arrangement have been reported. In this study, candidate materials that can be used for metal 3D printing are selected, and the physical properties and radiation dose of each material are analyzed to develop a customized shielding block that can be used in electron beam therapy. As candidate materials, aluminum alloy (d = 2.68 g/cm3), titanium alloy (d = 4.42 g/cm3), and cobalt chromium alloy (d = 8.3 g/cm3) were selected. The thickness of the 95% shielding rate point was derived using the Monte Carlo Simulation with the irradiation surface and 6, 9, 12, and 16 energies. As a result of the simulation, among the metal 3D printing materials, cobalt chromium alloy (d = 8.3 g/cm3) was similar to the existing shielding block (d = 9.4 g/cm3) in shielding thickness for each energy. In a follow-on study, it is necessary to evaluate the usefulness in clinical practice using customized shielding blocks made by metal 3D printing and to verify experiments through various radiation treatment plan conditions.

Evaluation of the Shielding Effect of Lead Apron according to the Energy Spectrum Change of 99mTc (99mTc의 에너지 스펙트럼 변화에 따른 납 앞치마의 차폐 효과 평가)

  • Changyong Yoon;Youngsik Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.889-896
    • /
    • 2023
  • Changes in the energy spectrum were analyzed using 99mTc as a point source and a scattering phantom, and the shielding effect of the lead apron according to the changed gamma ray energy was evaluated. In the gamma ray energy spectrum of the scattering phantom, the photo peak area decreased and the compton scattering area increased compared to the point source. The coefficients for each energy range according to the change in the shape of the gamma ray source showed a reduction rate of up to 66.1 % at a distance of 20 cm compared to the coefficient of the point source, and in the compton scattering area, the coefficient of the scattering phantom was 122.2 % at a distance of up to 40 cm compared to the coefficient of the point source. In the difference in shielding rate according to the distance between the source and the scattering phantom using a gamma camera, the photo peak area showed similar results, but in the Compton scattering area, the shielding rate of the scattering phantom at a distance of 20 cm increased by 29.2 % compared to the shielding rate of the point source. As the distance increased, the difference in shielding rate decreased. In measuring the shielding rate of the lead apron using a radiation dosimeter, the difference in the shielding rate of the scattering phantom was up to 15.3 %, and as the distance increased, the difference in the shielding rate between the two sources decreased. The shielding rate of the lead apron of the scattering phantom is higher than that of the point source, and the effectiveness of the lead apron increases as the distance to the source increases. As a result, wearing a lead apron when directly confronting a patient who has injected radioactive pharmaceuticals is expected to be helpful in reducing radiation exposure.

Dependency of Generator Performance on T1 and T2 weights of the Input MR Images in developing a CycleGan based CT image generator from MR images (CycleGan 딥러닝기반 인공CT영상 생성성능에 대한 입력 MR영상의 T1 및 T2 가중방식의 영향)

  • Samuel Lee;Jonghun Jeong;Jinyoung Kim;Yeon Soo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.37-44
    • /
    • 2024
  • Even though MR can reveal excellent soft-tissue contrast and functional information, CT is also required for electron density information for accurate dose calculation in Radiotherapy. For the fusion of MRI and CT images in RT treatment planning workflow, patients are normally scanned on both MRI and CT imaging modalities. Recently deep-learning-based generations of CT images from MR images became possible owing to machine learning technology. This eliminated CT scanning work. This study implemented a CycleGan deep-learning-based CT image generation from MR images. Three CT generators whose learning is based on T1- , T2- , or T1-&T2-weighted MR images were created, respectively. We found that the T1-weighted MR image-based generator can generate better than other CT generators when T1-weighted MR images are input. In contrast, a T2-weighted MR image-based generator can generate better than other CT generators do when T2-weighted MR images are input. The results say that the CT generator from MR images is just outside the practical clinics and the specific weight MR image-based machine-learning generator can generate better CT images than other sequence MR image-based generators do.

Reproducibiity of setup error for prostate cancer by ultrasound image-guided radiation therapy (전립선암에 대한 초음파 영상유도 방사선치료의 Setup 오차 분석을 통한 재현성 평가)

  • Park, Sung Yong;Lim, Seung Kyu;Si, Myoung Geun;Lee, Ji Hae;Kim, Jong Yeol;Cho, Eun Joo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.75-81
    • /
    • 2017
  • Purpose: To evaluate the reproducibility of image-guided radiotherapy using ultrasonography which is non-invasive, without radiation exposure for prostate cancer patients. Materials and Methods: We analyzed the setup variation of 1,105 images for 26 prostate cancer patients and the mean, standard deviation and 3D-error in AP, RL and SI directions. Setup variations were classified 0-1 mm, 1-3 mm, 3-5 mm, 5 mm and more. Results: The mean and standard deviation of setup variation in AP, RL and SI directions was $1.87{\pm}1.36mm$, $1.73{\pm}1.22mm$ and $2.01{\pm}1.40mm$. The 3D-error in AP, RL and SI directions was $3.63{\pm}1.63mm$. The frequency of setup variation in AP direction was 29 % in the range from 0 mm to 1 mm, 50.2 % in the range from 1 mm to 3 mm, 19.6 % in the range from 3 mm to 5 mm and 1.3 % in the range of 5 mm or more. In RL direction, the frequency was 31.3 % in the range from 0 mm to 1 mm, 52.5 % in the range from 1 mm to 3 mm, 15.8 % in the range from 3 mm to 5 mm and 0.5 % in the range of 5 mm or more. SI direction, the frequency of errors in the range from 0 mm to 1 mm was 26.3 %, 50.2 % in the range from 1 mm to 3 mm, 22.4 % in the range from 3 mm to 5 mm, and 1.1 % in the range of 5 mm or more. Conclusion: The setup error was highest in the SI direction of $2.01{\pm}1.40mm$. The frequency in each direction was the highest in more than 50 % in the range from 1 mm to 3 mm. $Clarity^{TM}$ Auto scan is possible to monitoring the motion of the prostate during the treatment and to repositioning the patient. In conclusion real-time image-guided radiotherapy using ultrasonography will be increase the reproducibility of radiation therapy.

  • PDF

The objective and quantitative analysis of malocclusion : Part 1. Objective malocclusion severity and subjective treatment difficulty (부정교합의 객관적 정량분석: Part 1. 객관적 부정교합 경중도와 주관적인 치료난이도의 상관관계)

  • Joo, Bo-Hoon;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.35 no.1 s.108
    • /
    • pp.60-68
    • /
    • 2005
  • The evaluation of malocclusion has to be done quantitatively and qualitatively. This will be lead toward an analysis of malocclusion severity as well as treatment difficulty. The method of proper evaluation of malocclusion severity and treatment difficulty is necessary to assess treatment effect and efficiency for the orthodontists and to establish fundamentals for planning and executing the health-related policies in private and public institutions. The purposes of this study as the first part of the objective and quantitative analysis of malocclusion were 1) to measure treatment difficulty based on the opinions of several orthodontists. and 2) to investigate the relationships between objective malocclusion severity and subjective treatment difficulty 100 pairs of dental casts that had various types and severity of malocclusion were selected from the orthodontic departments of Kyurghee University and Samsung Medical Center The objective malocclusion severity was measured with the PAR (Peer Assessment Rating) index and the subjective treatment difficulty was evaluated by 8 experienced orthodontists. The relationships between objective malocclusion severity and subjective treatment difficulty were statistically evaluated. There were significant relationships between objective malocclusion severity and subjective treatment difficulty especially in the measurements of the upper anterior alignment, the buccal occlusion. the overjet, the overbite and the midline discrepancy en the malocclusion components. The results of this study can provide the background knowledge to develop a new occlusal index. which contains both the malocclusion severity and treatment difficulty for Korean orthodontists.