• Title/Summary/Keyword: 환자수

Search Result 13,880, Processing Time 0.042 seconds

Intravitreal Anti-vascular Endothelial Growth Factor Injections to Treat Neovascular Age-related Macular Degeneration: Long-term Treatment Outcomes (삼출 나이관련황반변성에 대한 항혈관내피성장인자 유리체내주사 치료의 장기 임상 결과)

  • Park, Yu Jeong;Son, Gi Sung;Kim, Yoon Jeon;Kim, June-Gone;Yoon, Young Hee;Lee, Joo Yong
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.12
    • /
    • pp.1142-1151
    • /
    • 2018
  • Purpose: We assessed the visual and anatomical outcomes, and the safety profile of long-term intravitreal anti-vascular endothelial growth factor (VEGF) injections (aflibercept, ranibizumab, and bevacizumab) given to treat neovascular age-related macular degeneration (NAMD). Methods: We analyzed medical records collected over 7 years of treatment-naive NAMD patients who received outpatient clinic-based intravitreal anti-VEGF injections. All were treated employing either "treat-and-extend" or "as needed" protocols at the discretion of the retinal specialist. The number of injections, adverse events associated with injection, and measures of visual acuity (VA), central foveal thickness (CFT), and intraocular pressure (IOP) were recorded. Results: Overall, we assessed 196 eyes of 196 patients (average age $68.6{\pm}9.6years$; 77 females). Patients received an average of $17.3{\pm}13.5$ injections over $78.0{\pm}16.5months$ of clinical follow-up. The initial mean VA (logMAR) was $0.75{\pm}0.58$ and the CFT was $349.7{\pm}152.6{\mu}m$. Both parameters exhibited maximal improvements at the 6-month visit (p < 0.05). However, the clinical outcomes worsened over the 7-year clinical course; the best-corrected visual acuity (BCVA) was $0.91{\pm}0.78$ and the CFT was $284.5{\pm}105.8{\mu}m$ at 7 years. The BCVA at 7 years was significantly correlated with the initial BCVA. IOP-related events increased 11-fold and anterior chamber reactions increased 3-fold over the years, but no significant complications such as endophthalmitis were recorded. Conclusions: The use of intravitreal anti-VEGF agents was associated with initial visual improvements over 6 months but did not prevent the worsening of NAMD over 5 years. The BCVA at the initial visit was a strong predictor of the final BCVA. A more intensive injection schedule might improve long-term outcomes.

The Comparion of Pregnancy Outcomes between GnRH Agonist and GnRH Antagonist Cycles in Women with Advanced Age (37세 이상의 환자에서 체외수정시술시 GnRH Agonist 주기와 GnRH Antagonist 주기의 비교 연구)

  • Park, Chan Woo;Cha, Sun Wha;Kim, Hae Suk;Kim, Hye Ok;Yang, Kwang Moon;Kim, Jin Young;Song, In Ok;Yoo, Keun Jae;Kang, Inn Soo;Koong, Mi Kyoung
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.32 no.3
    • /
    • pp.261-268
    • /
    • 2005
  • Objective: To compare the clinical results and pregnancy outcomes of in vitro fertilization (IVF) between GnRH antagonist cycles and GnRH agonist (GnRH-a) cycles including flare-up and long protocol in women with advanced age. Materials and Methods: Retrospective clinical study. From January 2001 to September 2003, IVF cycles of female patient 37 years over were included in this study. GnRH-a long protocol (62 cycles, 61 patients) and GnRH antagonist multi-dose flexible protocol (66 cycles, 51 patients) were compared with the control group of GnRH-a flare-up protocol (151 cycles, 138 patients). IVF cycles for non-obstructive azoospermia (NOA), endometriosis III, IV and polycystic ovarian syndrome (PCOS) were excluded in this study. Clinical results such as total gonadotropin dose, serum E2 on hCG administration, the number of retrieved oocytes and the pregnancy outcomes - clinical pregnancy rate (CPR), implantation rate (IR) and live birth rate (LBR) per embryo transfer - were compared. Results: There were significant differences in the total dose of gonadotropin (GnRH-a flare-up vs. GnRH-a long vs. GnRH-antagonist; 41.8 vs. 54.7 vs. 24.8), serum E2 on hCG administration (1787.2 vs. 1881.6 vs. 788.0), the numbers of retrieved oocytes (8.1 vs. 11.1 vs. 4.5) and endometrial thickness (9.1 vs. 10.4 vs. 8.0) which were significantly lower in GnRH-antagonist cycles. But pregnancy outcomes shows no significant differenced in CPR (25.0% vs. 35.8% vs. 24.5%), IR (11.7% vs. 12.3% vs. 10.1%) and LBR (15.8% vs. 28.3% vs. 15.1%) Conclusion: In women with advanced age, GnRH-antagonist cycles can result in comparable pregnancy outcomes to GnRH-a cycles including flare-up and long protocol. GnRH-a long protocol show higher CPR, IR and LBR than GnRH antagonist multi-dose flexible protocol and flare-up protocol without significant differences.

Efficacy and Safety of Topical Application of Epidermal Growth Factor (EGF) for Korean Acne Patient (한국인 여드름 환자에서 표피성장인자가 함유된 외용제의 피부 적용에 대한 유효성 및 안전성 평가)

  • Suh, Joon Hyuk;Hyun, Moo Yeol;Jang, Seong Eum;Choi, Sun Young;Kim, Myeung Nam;Kim, Beom Joon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.42 no.2
    • /
    • pp.111-118
    • /
    • 2016
  • Acne vulgaris is a chronic inflammatory condition characterized by comedo, papule, cyst, nodule and postinflammatory hyperpigmentation. Meanwhile, it is also induced by adverse event of drugs. Among them, acneiform folliculitis is a side effect of epidermal growth factor receptor (EGFR) inhibitor, which is an anticancer agent, and its incidence may occur in upward of 75 ~ 100% of cases. The main method of acne vulgaris treatment is oral antibiotics, retinoids, topical medication and so on. However, it is limitation that teratogenicity caused by retinoids and antibiotic resistance increased by using antibiotics. In this study, we aimed to evaluate the clinical efficacy and safety of topical recombinant human (rh) EGF in treating facial acne vulgaris. Twenty three Koreans (age: 10 ~ 29 years) with mild to moderate acne vulgar participated in the study and applied topical rhEGF cream (trouble control EGF) with 3 products (trouble control clarifying cleansing foam, trouble control all-clear filling toner, redroll calming moisture) on their face twice daily for four weeks. Several assessment methods were applied: Acne lesion counts score by investigator's global assessment, efficacy and satisfaction score by subjects. Skin sebum output level, hydration level and redness level were also measured at each visit. At the final visit, skin sebum level, transepidermal water loss, skin redness statistically decreased and acne lesions (comedone, papule) were statistically reduced. No severe side effects were observed during the study. In conclusion, topical rhEGF seems to be an effective and safe adjuvant treatment option for mild acne vulgaris.

Association of Body Mass Index and Cognitive Function in Alzheimer's Disease and Mild Cognitive Impairment (알츠하이머병과 경도인지장애에서 체질량지수와 인지기능과의 연관성)

  • Lim, Eun Jeong;Lee, Kang Joon;Kim, Hyun
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.24 no.2
    • /
    • pp.184-190
    • /
    • 2016
  • Objectives : This study analyzed the differences of body mass index(BMI) in Korean patients with Alzheimer's diseases(AD), Mild Cognitive Impairment(MCI), and healthy controls to verify whether low BMI is associated with cognitive impairment. Furthermore, this study also sought to examine any association between BMI and Mini Mental State Examination-Korean version(MMSE-K), Clinical Dementia Rating(CDR), and Global Deterioration Scale(GDS). Methods : A total of 257 subjects were included in the study. History taking, mental status examination, physical examination and neurocognitive function test were carried out for the diagnosis of AD and MCI. The subjects' demographic data and presence of diseases were also surveyed. The overall cognitive function and severity of diseases were assessed using MMSE-K, GDS, and CDR. Results : The order of BMI was found to be healthy controls>MCI>AD, with statistically significant differences among the groups. The order of MMSE-K scores was similar, with healthy controls>MCI>AD in statistically significant differences. The healthy controls had the lowest CDR and GDS scores, and AD patients had the highest scores. There was a significant positive correlation between BMI and MMSE scores(r=0.238, p=0.000). BMI was negatively correlated with CDR(r=-0.174, p=0.008) as well as with GDS(r=-0.233, p= 0.000). Conclusions : Measuring BMI of patients with AD or MCI is expected to be meaningful in that BMI could be a clinical indicator of AD. We expect this to be beneficial for the diagnosis, prevention, and therapeutic approach of AD and also expect large-scale, long-term longitudinal studies to follow.

Validation of the Korean version of Center for Epidemiologic Studies Depression Scale-Revised(K-CESD-R) (한국판 역학연구 우울척도 개정판(K-CESD-R)의 표준화 연구)

  • Lee, San;Oh, Seung-Taek;Ryu, So Yeon;Jun, Jin Yong;Lee, Kounseok;Lee, Eun;Park, Jin Young;Yi, Sang-Wook;Choi, Won-Jung
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.24 no.1
    • /
    • pp.83-93
    • /
    • 2016
  • Objectives : The Center for Epidemiologic Studies Depression scale-Revised is a recently revised scale which has been reported as a valid tool for the assessment of depressive symptoms. It encompasses cardinal symptoms of depression described in the Diagnostic and Statistical Manual of Mental disorders, fourth edition. In this study, we assessed the reliability, validity and psychometric properties of the Korean version of the CESD-R(K-CESD-R). Methods : Forty-eight patients diagnosed as major depressive disorder, dysthymia, depressive disorder NOS according to the DSM-IV criteria using Mini International Neuropsychiatric Interview and 48 healthy controls were enrolled in this study. They were assessed with K-CESD-R, K-MADRS, PHQ-9, KQIDS-SR, STAI to check cross-validation. Statistical analyses were performed using calculation of Cronbach's alpha, Pearson correlation coefficient, Principal Component Analysis, ROC curve and optimal cut-off value. Results : The Cronbach's alpha of K-CESD-R was 0.98. The total score of K-CESD-R revealed significantly high correlations with those of K-MADRS, PHQ-9, KQIDS-SR(r=0.910, 0.966 and 0.920, p<0.001, respectively). Factor analysis showed two factors account for 76.29% of total variance. We suggested the optimal cut-off value of K-CESD-R as 13 according to analysis of the ROC curve which value sensitivity and specificity both equally. Conclusions : These Results showed that the K-CESD-R could be a reliable and valid scale to assess depressive symptoms. The K-CESD-R is expected as a useful and effective tool for screening and measuring depressive symptoms not only in outpatient clinic but also epidemiologic studies.

Production and biological applications for marine proteins and peptides- An overview (해양생물로부터 기능성 펩티드의 생산 및 응용)

  • Kim, Se-Kwon;Byun, Hee-Guk
    • Food Science and Industry
    • /
    • v.51 no.4
    • /
    • pp.278-301
    • /
    • 2018
  • Although more than 80% of living organisms are found in marine ecosystems, only less than 10% of marine resources have been utilized for human food consumptions and other usages. It is well known that marine resources (fish, shellfish and algae) have exceptional nutritional properties; however, their functional characteristic has not been completely discovered. It is believed that metabolites (organic compounds, proteins, peptides, lipids, minerals, etc.) play an important role to show its biological properties. Marine proteins and peptides are considered to be future drugs due to their excellent biological activities with a fewer adverse side effect. Marine peptides show several biological activities, including antimicrobial, antioxidant, anti-inflammatory, anti-cancer, anti-viral, anti-tumor, anti-diabetic, anti-hypertensive, anti-coagulant, immunomodulatory, appetite suppressing and neuroprotective effects. Therefore, the pharmaceutical, nutraceutical, and cosmeceutical companies have been paid attention to the marine peptides to commercialize into products. This current review mainly focused on the above mentioned biological activities of marine peptides and protein hydrolysates as a functional food and pharmaceutical applications. To commercialize these materials in industrial level required large quantity in high-purity level, and it is complicated to produce huge quantity from the marine resources due to insufficient raw materials, unavailability of raw materials through a year, hinder the growth with geographical variations, and availability of compounds in extreme small quantities. The best solution for these issues is to introduce new modern technologies such as artificial intelligence robots, drones, submersibles and automated raw material harvesting vessels in farming industries instead of man power, which will lead to 4th industrial revolution.

A Study on the Fabrication and Comparison of the Phantom for CT Dose Measurements Using 3D Printer (3D프린터를 이용한 CT 선량측정 팬텀 제작 및 비교에 관한 연구)

  • Yoon, Myeong-Seong;Kang, Seong-Hyeon;Hong, Soon-Min;Lee, Youngjin;Han, Dong-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.737-743
    • /
    • 2018
  • Patient exposure dose exposure test, which is one of the items of accuracy control of Computed Tomography, conducts measurements every year based on the installation and operation of special medical equipment under Article 38 of the Medical Law, And keep records. The CT-Dose phantom used for dosimetry can accurately measure doses, but has the disadvantage of high price. Therefore, through this research, the existing CT - Dose phantom was similarly manufactured with a 3D printer and compared with the existing phantom to examine the usefulness. In order to produce the same phantom as the conventional CT-Dose phantom, a 3D printer of the FFF method is used by using a PLA filament, and in order to calculate the CTDIw value, Ion chambers were inserted into the central part and the central part, and measurements were made ten times each. Measurement results The CT-Dose phantom was measured at $30.44{\pm}0.31mGy$ in the periphery, $29.55{\pm}0.34mGy$ CTDIw value was measured at $30.14{\pm}0.30mGy$ in the center, and the phantom fabricated using the 3D printer was measured at the periphery $30.59{\pm}0.18mGy$, the central part was $29.01{\pm}0.04mGy$, and the CTDIw value was measured at $30.06{\pm}0.13mGy$. Analysis using the Mann - Whiteney U-test of the SPSS statistical program showed that there was a statistically significant difference in the result values in the central part, but statistically significant differences were observed between the peripheral part and CTDIw results I did not show. In conclusion, even in the CT-Dose phantom made with a 3D printer, we showed dose measurement performance like existing CT-Dose phantom and confirmed the possibility of low-cost phantom production using 3D printer through this research did it.

Diagnostic Availability of Estrogen Receptor Alpha mRNA on Cervical Cancer Tissue (자궁경부암 조직에서 에스트로겐 수용체 알파 mRNA의 진단적 유용성)

  • Kim, Geehyuk;Yu, Kwangmin;Kim, Jungho;Kim, Seoyong;Park, Sunyoung;Ahn, Sungwoo;Lee, Ji-Young;Kim, Sunghyun;Park, Ho-Hyun;Lee, Dongsup
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.4
    • /
    • pp.449-456
    • /
    • 2018
  • Cervical cancer is the fourth most frequently diagnosed cancer in women worldwide. In lower Human Development Index countries, it has the second highest incidence and mortality among cancer in women. Therefore, better diagnosis and treatment systems are needed. Among them, estrogen receptor alpha ($ER-{\alpha}$) mRNA expression has been analyzed with RT-qPCR since several studies reported that $ER-{\alpha}$ is necessary in the maturation of the uterus and is related to cervical cancer. In this study, $ER-{\alpha}$ quantitative analysis was performed on various lesions and normal tissue samples. Based on the receiver operating characteristic (ROC) curve, its sensitivity and specificity were 85% and 75%, respectively, showing higher or similar results to those of conventional HPV tests. In addition, its expression level was analyzed with clinical information. With regression analysis, the R square value between the $ER-{\alpha}$ mRNA expression level and menopause status was 0.5041, indicating a strong correlation. This study was performed as part of a pilot study and suggests that $ER-{\alpha}$ is related to carcinogenesis. Future studies will examine other hormones and menopausal factors with a larger sample size.

Influence of crown-to-implant ratio of short vs long implants on implant stability and marginal bone loss in the mandibular single molar implant (하악 구치 단일임플란트 수복에서 임플란트 길이에 따른 치관-임플란트 비율이 임플란트안정성 및 변연골소실에 주는 영향)

  • Baek, Yeon-Wha;Kim, Bongju;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.280-289
    • /
    • 2018
  • Purpose: The purpose of this randomized clinical trial is to determine whether implant length and the crown-to-implant (C/I) ratio influence implant stability and peri-implant marginal bone loss (MBL). Materials and Methods: 46 patients with single tooth missing in the posterior molar region of the mandible were included in this study. 19 implants (CMI IS-III $active^{(R)}$ long implant) of 5.0 mm diameter and 10 mm length were installed for the control group, while 27 implants (CMI IS-III $active^{(R)}$ short implant) of 5.5 mm diameter and 6.6, 7.3 or 8.5 mm length were placed for the experimental group. Each implant was inserted and immediately loaded using the digitally pre-fabricated surgical template and provisional restoration. The CAD-CAM monolithic zirconia crown was fabricated at 3 months after the surgery as a definitive restoration. The ISQ value and the MBL was measured at 48 weeks after the surgery. The correlation between the C/I ratio, MBL, and secondary implant stability was analyzed. Results: Successful results in terms of ISQ and MBL were achieved with both groups. There was no significant difference between the groups in terms of ISQ values and MBL at 48 weeks after the surgery (P > 0.05). No significant correlation was found between the C/I ratio and secondary stability as well as the C/I ratio and the MBL (P > 0.05). Conclusion: The influence of C/I ratio in both groups was not shown on the stability nor the marginal bone loss in implants supporting single crown of the mandible. Short implant could be a preferable alternative option in the reduced bone height mandible under the limited condition despite its higher C/I ratio.

Comparison of Doses of Single Scan PBS and Layered Rescanning PBS Using Moving Phantom in Proton Therapy (양성자 치료에서 Moving Phantom을 이용한 Single Scan PBS와 Layered Rescanning PBS의 선량비교)

  • Kim, Kyeong Tae;Kim, Seon Yeong;Kim, Dae Woong;Kim, Jae Won;Park, Ji Yeon;Jeon, Sang Min
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.43-49
    • /
    • 2019
  • Purpose : We apply the Layered Rescanning PBS designed to complement the Pencil Beam Scanning(PBS), which is vulnerable to moving organs with the Moving Phantom, and compare the homogeneity with the single scan PBS. Methods and materials: Matrix X (IBA, Belgium) and Moving Phantom (standard imaging, USA) were used. A dose of 200 cGy was measured in the AP direction on a hypothetical tumor $10{\times}10{\times}5cm$. The plan type was planned as 4 kinds of sinlge scan PBS, rescan number 4, 8, 12 times. Were measured three times for each types. During the measurement, the respiratory cycle of the Moving Phantom was generally set to 4 seconds per cycle, and the movement radius in the S-I direction was set to 2 cm. In addition, beam on time was measured. Results : The mean values of $D_{max}$ in the PTV were $246.47{\pm}18.8cGy$, $223.43{\pm}8.92cGy$, and $222.47{\pm}7.7cGy$, $213.9{\pm}6.11cGy$ and the mean values of $D_{min}$ were $165.53{\pm}4.32cGy$, $173.13{\pm}11.94cGy$, $184.13{\pm}8.04cGy$, $182.67{\pm}4.38cGy$ and the mean values of $D_{mean}$ $192.77{\pm}6.98cGy$, $196.7{\pm}4.01cGy$, $198.17{\pm}4.96cGy$, $195.77{\pm}3.15cGy$ respectively. As the number of rescanning increased, the Homogeneity Index converged to 1. The beam on time was measured as 2:15, 3:15, 4:30, 5:37 on average. In the measurement process, in the low dose layer of the MU, the problem was found that it was not rescanned as many times as the set number of rescan. Conclusions : In the treatment of tumors with long-term movements, the application of layered rescanning PBS showed a more uniform dose distribution than single scan PBS. And as the number of rescan increase, the distribution of homogeneity is uniform. Compared with single scan plan and 12 rescan plan, HI value was improved by 0.32. Further studies are expected to be applicable to patients who can not be treated with respiratory synchronous radiation therapy.