• Title/Summary/Keyword: 환기팬

Search Result 147, Processing Time 0.035 seconds

Evaluation of Smoke Control Performance of Ventilation System Using by Hot Smoke Test (Hot Smoke Test를 이용한 주차장 환기설비의 제연 성능평가)

  • Joung, Suckhwan
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.2
    • /
    • pp.47-56
    • /
    • 2019
  • Recently, in order to overcome the difficulty of entering a fire source due to the occurrence of a large amount of smoke in the event of a fire in a parking lot, it has used that a method of discharge smoke using air supply, exhaust fans and jet fans installed for ventilation of parking lots. In this study, the variation of flow in the smoke layer was observed using CCTV under two conditions, in which only the air supply fan operates and the manned fan operates together, and the temperature around the plume was compared to Albert eq. to assess its suitability as a parking lot ventilation performance evaluation method. As a result, it was found that the smoke layer could be disturbed if the Jet Fan was operated at the same time, which could lead to the possibility of an initial evacuation disturbance. However, the additional operation of the Jet Fan has been confirmed by the observation CCTV that the emission performance is improved, which is believed to help conduct the suppression operation. The temperature around the plume was measured and compared to Alpert eq, and was analyzed to be about $2^{\circ}C$ lower at the center axis of the plume and $9.0^{\circ}C$ higher at 8 m in the direction of the discharge of smoke. The results of temperature measurements around the plume were lower than the maximum temperature expected in AS 4391 and did not exceed the expected temperature risk caused by the experiment. As with these results, the temperature risk from the progression of hot smoke tests is foreseeable, so it will be available as one of the general evaluation methods for assessing smoke control performance in a parking lot without relevant criteria.

Optimization Design of Commercial Large Gas Oven Systems (상업용 대형 가스오븐 시스템의 최적 설계)

  • Kim, Do-Hyun;Yu, Byeonghun;Kum, Sungmin;Lee, Chang-Eon
    • Journal of Energy Engineering
    • /
    • v.25 no.2
    • /
    • pp.21-28
    • /
    • 2016
  • This research was conducted for the optimal design of large commercial gas oven system. Equivalent ratio was determined through a numerical analysis and experiments on the combustion condition of the combustor. After reviewing the supply capacity of burner(20,000 kcal) and control method of convection fan, two types of heat exchangers designed. In order to maintain a uniform temperature inside the oven is required convection fan braking system. The center temperature in the oven rises more rapidly when the convectional fan is rotated in the counterclockwise direction than the counter-clockwise direction. And The efficiency of the system by installing a large heat transfer area was higher.

The Effect of Makeup Air on Kitchen Hoods (주방후드에서 보급공기의 영향)

  • 장경진
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.32 no.11
    • /
    • pp.63-68
    • /
    • 2003
  • 주방환기의 계획에 있어서 조리시 발생하는 오염물질을 적절히 배기시키는 것이 가장 중요하다. 기구의 배치와 발열량을 평가하고 후드의 위치와 종류 그리고 덕트직경과 경로를 결정하며 적정한 풍량을 제거하기 위한 배기팬을 선정한다. 그러나 일반적인 실내 공기밸런스 계획을 시행함에도 불구하고 배기된 체적에 해당하는 풍량을 보충 공급하는 방식에 대한 고려는 현재 상대적으로 부족한 상태이다.

  • PDF

The Effects of Winch-curtain Ventilation on the Indoor Environment of a Fattening Swine House (윈치커튼 환기가 비육돈사의 실내 환경에 미치는 영향)

  • Kim, Hyeon-Tae;Song, Jun-Ik;Choi, Hong-Lim
    • Journal of Animal Environmental Science
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • The study was conducted to investigate the effects of climate on indoor environment of a swine house with natural. This study was tested in the beef swine stall at Young-in, Kyung-ki do. The test was experimented for the effect of interior environment by the outdoor environment and the interior-pan. The results are as follows. 1. In test 1 ($T_{out}$ : $25.7^{\circ}C$, without fan), an indoor air flow pattern was showed that entered from sidewall winch-curtain to went out of a indoor by the ridge winch-curtain. And the velocity of a section of the center was measured two times as large as the velocity of the floor. It is the acceleration of the velocity by thermal buoyancy. And, the entered air was rapidly dissipated by flow energy. So that in the swain livestock with sidewall winch-curtain is effected by thermal buoyancy. And the air temperature of the indoor was distributed more higher as compared with the outdoor temperature. This result is caused by the sensible heat from swine and the ventilation is restricted. 2. In test 2 (($T_{out}$ : $25.7^{\circ}C$, with fan), the velocity of a section of the center was measured more higher as compared with the test 1. And the variance of air velocity was distributed higher as compared with the test 1. This result is showed dead region of air flow with a fan operation. And, the variance of gas density was distributed lower as compared with the test 1.

A Comparative Analysis of Energy Performance according to the Ventilation System in Apartment House (공동주택의 환기시스템별 에너지성능 비교 분석)

  • Kim, Gil-Tae;Chun, Chu-Young;Kim, Sun-Dong
    • Land and Housing Review
    • /
    • v.6 no.4
    • /
    • pp.215-220
    • /
    • 2015
  • The purpose of this study was to comparative analyses of energy performance in apartment houses adopted window frame-type natural ventilation, under-floor air distribution ventilation and heat recovery ventilation. As the object of energy simulation, the three type ventilation system with area of $84m^2$ was selected in apartment house. As a result, when the ECO2 simulation was performed, the 1st requirement quantity per annual were $159.9kWh/m^2yr$(CASE1, Natural Ventilation), $179.7kWh/m^2yr$(CASE2, Under-floor Air Distribution Ventilation) and $161.0kWh/m^2yr$(CASE3, Heat Recovery Ventilation).

Technological Advances for Particulate Matter Collection in Subway System (지하철 미세먼지 포집을 위한 기술적 진보)

  • Son, Youn-Suk;Ryu, Jae-Yong
    • Prospectives of Industrial Chemistry
    • /
    • v.21 no.2
    • /
    • pp.24-34
    • /
    • 2018
  • 본 연구에서는 지하역사 및 터널에서 발생되는 미세먼지의 현황 및 이를 저감하기 위한 기술의 동향을 조사하였다. 지하역사 및 터널의 미세먼지 농도는 주변 대기 중의 농도보다 높은 것으로 나타났다. 그 구성 성분에 있어서 다양한 중금속 및 발암물질들을 함유하고 있고, Fe의 농도가 가장 높게 나는 것을 알 수 있었다. 지하역사 및 터널의 미세먼지 농도는 주변 대기 농도와 같은 외부 요인뿐만 아니라 열차의 운행 수, 이용 승객수, 환기량과 같은 내부 요인도 큰 영향을 미치는 것을 확인할 수 있었다. 현재 지하역사 및 터널의 미세먼지를 저감하기 위해서 다양한 기술(환기팬, 스크린도어, 자성필터, 소형제트팬, 인공지능 환기시스템 등)들이 연구되고 있으며, 그 기술들은 현장 조건에 맞추어 사용되어야 그 실효성을 극대화시킬 수 있을 것이다.

A Study on an Optimal Design of Jet Fan Location Considering the Voltage Drops in Tunnels (전압강하를 고려한 터널내 환기 및 방재팬의 경제적 위치선정에 대한 연구)

  • Kim, Eun-Soo;Kim, Hyo-Gyu;Song, Jung-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.105-109
    • /
    • 2004
  • 우리나라 지형의 특성은 약 70%가 산으로 이루어져 있다. 이러한 지형적 여건은 교통과 관련된 사회간접 자본의 증가로 이어지며, 최근에는 산업의 발전에 힘입어 교통량의 증가와 물류비용의 절감을 목적으로 철도 및 도로의 건설시 터널의 계획 및 시공이 증가되고 있는 추세이다. 이에 따라 터널의 환경개선과 화재시 제연을 목적으로 설치되는 제트팬(Jet Fan)의 용량이 차지하는 전기적 비중이 높아지고, 전압강하에 대한 손실율이 증가되고 있다. 따라서 제트팬의 설치시 배치방법과 터널의 길이에 따른 전기실 배치를 Case 별로 분류하여 전압강하를 계산하고 분석하여 가장 효율적이며 경제적인 방안을 연구하고 정리하여 향후 설계시 기초자료를 제공하고자 하였다.

  • PDF

Study on the Performance Improvement of Ventilation Fan Installed in Walls of Underground Parking Lots (벽체 매립형 환기용 팬 성능개선에 관한 연구)

  • Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.206-211
    • /
    • 2014
  • The objective of the present study was to identify ventilation problems, and also to suggest new axial fan systems for the improvement of IAQ in the underground parking lots. Numerical results for air mean-velocity, local mean age, and sound power level are presented along with some of fan angles. The results showed the influence of airflow patterns on the fan performances installed in the underground parking lots. Discharge air volume is increased with the angle of the blade. And also, the main factors affecting the noise of the ventilation fan was found to be a rotational speed.

Investigation of Ventilation Efficiency for the Natural Gas High Pressure Release in an Underground Valve Station (지하 공급관리소내 천연가스 고압분출시 환기효율성 검증)

  • Ha J. M.;Lee J. H.;Sung W. M.
    • Journal of the Korean Institute of Gas
    • /
    • v.6 no.1 s.17
    • /
    • pp.74-80
    • /
    • 2002
  • This study was carried out for the purpose of safety evaluation about the ventilation system (according to the structure of confined room, the position and size of vent window, the amount of blowing air, e.t.c.), which is equipped in one of KOGAS underground valve stations. Particularly, the effect of the fans placed in the upper region was focused in detail. Numerical simulation was conducted in order to predict the features of flow pattern and the diffusion of natural gas concentration. This work examined the ventilation system and resulted in proposing an optimal design of ventilation system.