• Title/Summary/Keyword: 환기방식

Search Result 302, Processing Time 0.035 seconds

The study of operation mode of ventilation system in the longitudinal ventilation system tunnel (조합환기 방식 터널의 환기기 운전 단계에 관한 연구)

  • Yoo, Ji-Oh;Shin, Hyun-Jun;Lee, Dong-Ho;Lee, Young-hwa
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.4 no.4
    • /
    • pp.343-353
    • /
    • 2002
  • In the past many tunnels have been built to lowest capital investment cost without adequate regard for the cost of operation. But according to increasing the capacity of a ventilation system and to becoming diverse, it is to become more important to come up with the optimal operation stage of ventilation system. In this study, the tunnel ventilation dynamic simulation program had been developed. it is used to calculate the unsteady-state tunnel air velocity and concentration of pollutants according to the assumed average day traffic profile and summarize the energy consumption for the operation of ventilation system. And the operation energy consumption for the electric precipitation system and vertical vent shaft system are evaluated and compared in various operation mode. As the results of this study, the optimal operation stage for these ventilation system are provided.

  • PDF

A Study on a Graphical Method for Determining the Characteristics of Jet-fan Ventilation System using the Contour Map of Required Ventilation Rate in Local Highways (지역별 소요환기량 특성도를 활용한 제트팬 환기방식 가능 터널제원 결정연구)

  • 김효규;김화수;김종대;이창우
    • Tunnel and Underground Space
    • /
    • v.13 no.3
    • /
    • pp.235-243
    • /
    • 2003
  • Recent worldwide trends show that tunnel length is getting longer, and the demand for longitudinal ventilation system with jet-fans in highway tunnels has also increased mainly due to the economic reasons. Improvements in vehicle engine subsequently reduced required ventilation rate(Qreq) which is the decisive factor in choosing the optimal ventilation system. Qreq contour map is a graph that defines the relationship among tunnel length, grade and required ventilation rate. It is important to understand the variation of Qreq in order to evaluate the characteristics of ventilation system with jet fans. Therefore this study aims at studying a graphical method for determining the characteristics of jet-fm ventilation system using Qreq contour map. Also, this study focuses on traffic composition on local highways.

기능성과 경제성을 겸비한 세종지하차도 설계

  • Jo, Seong-Tae;Song, Guk-Hwan;Lee, Hui-Geon
    • 한국도로학회지:도로
    • /
    • v.10 no.2
    • /
    • pp.58-67
    • /
    • 2008
  • 교통량이 많은 도심지내 장대 지하차도 건설은 교통정체 해소에 기여를 하지만 초기 공사비가 많이 소요되는 단점이 있다. 또한, 화재등 유고시 이용자의 안전을 최우선으로 고려되어야 한다. 즉, 장대 지하차도 건설에 있어서 경제성과 안전성이 함께 만족할 수 있는 건설 방안이 필요하다. 세종지하차도는 이러한 문제점을 극복하고자 다음과 같이 지하차도의 환기방식 및 단면, 포장형식, 사고 예방 및 발생시를 대비한 종합방재시스템을 구축하였다. $\cdot$환기방식은 종류식 환기방식의 경제성과 횡류식 환기방식의 제연성능을 겸비할 수 있는 조합형 환기방식과 Duct Arch 단면을 적용하여 공사비 절감 및 운영시 유지관리비를 획기적으로 절감하였다. $\cdot$지하차도 포장형식은 화재시 내화성이 우수하며 유독가스 발생이 없는 HPC(고성능 콘크리트 포장) 포장을 적용하여 이용자의 안전을 최우선으로 고려하였고 일반 아스팔트 포장 및 배수성 아스팔트 포장에 비해 우수한 성능과 공용수명을 가진 공법을 적용함으로서 유지보수비용의 절감을 가능하게 하였다. 또한, 콘크리트포장의 단점인 소음발생을 최소화하기 위해 타이닝과 그루빙을 적용하였다. $\cdot$지하차도내 화재 등 유고시 신속한 대피가 가능하도록 피난 연락문 간격을 167m 간격으로 설치하고 비상탈출계단 6개소를 확보하였다. 또한 노약자 및 환자의 지하차도 외부로 대피를 돕기 위해 비상엘리베이터 3개소를 설치하는 등 사고발생 시 종합적으로 대처할 수 있는 시스템을 마련하여 적용하였다.

  • PDF

환기시스템에 의한 Sick House 대책

  • Kimura, Hiroshi
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.32 no.9
    • /
    • pp.46-51
    • /
    • 2003
  • "환기"는 생활용품 등으로부터의 오염물질 및 불특정 물질의 농도 저감이 가능하기 때문에 Sick House 대책으로서의 중요한 대책기술이다. 본 고에서는 집합주택을 대상으로 한 중앙공조 환기방식 및 배기 중앙 환기방식의 사례를 보여주고, 시스템의 구성기술과 오염물질의 농도 저감효과에 대해서 기술한다. 또한, 대표적인 오염물질인 포름알데히드의 건자재로 부터의 발산량은 온습도, 환기량 및 건자재의 표면적 비율 등의 영향인자에 따라 변화하므로, 필요 환기량은 이들의 영향요인을 고려하여야 한다는 것을 기술한다.

  • PDF

A Comparative Analysis of Energy Performance according to the Ventilation System in Apartment House (공동주택의 환기시스템별 에너지성능 비교 분석)

  • Kim, Gil-Tae;Chun, Chu-Young;Kim, Sun-Dong
    • Land and Housing Review
    • /
    • v.6 no.4
    • /
    • pp.215-220
    • /
    • 2015
  • The purpose of this study was to comparative analyses of energy performance in apartment houses adopted window frame-type natural ventilation, under-floor air distribution ventilation and heat recovery ventilation. As the object of energy simulation, the three type ventilation system with area of $84m^2$ was selected in apartment house. As a result, when the ECO2 simulation was performed, the 1st requirement quantity per annual were $159.9kWh/m^2yr$(CASE1, Natural Ventilation), $179.7kWh/m^2yr$(CASE2, Under-floor Air Distribution Ventilation) and $161.0kWh/m^2yr$(CASE3, Heat Recovery Ventilation).

A study on the ventilation control method of road tunnel for small vehicles (소형차 전용 도로터널의 환기기 제어방안에 대한 연구)

  • Ryu, Ji-Oh;Lee, Hu-Young;Chang, Ji-Don
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.749-762
    • /
    • 2019
  • In recent years, in urban areas, underground of roads are being promoted in order to resolve traffic congestion and to secure green spaces, and due to the low ratio of large vehicles, they are planned or constructed as road tunnels for small cars only. In addition, the tunnels being built in the city is a tendency to be enlarged to play the role of main roads. Accordingly, the capacity of the ventilation system is increasing and various ventilation methods are required, and the importance of maintenance after the completion of the tunnel such as the operating cost of the ventilation system is emphasized. Therefore, the need for optimization of the operation stage for reducing the power consumption of the ventilation system and the study of the ventilation system operation control logic is increasing. In this study, the study on the necessity of the optimization of operation stage and control logic of the ventilation system was carried out to realize the energy-saving operation for the small car only passing through tunnels which is applied of ① jet fan and combination ventilation system (② jet fan + air purifying equipment, ③ jet fan + vertical shaft, ④ jet fan + supply air semi-transverse). As a result of this study, there can be various operating combinations in the case of the combined ventilation system, and even though the amount of ventilation air is the same, the operating power varies greatly according to the operating combinations. It was found that operating the axial fan first rather than the jet fan first operation method has an effect on power saving.

Natural Ventilation Effect of Bending Panel Type Windows in Greenhouse (굴절패널방식 환기창의 자연환기 효과)

  • Lee, Si-Young;Kim, Jin-Young;Kim, Hyun-Hwan;Jeon, Hee
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2000.10b
    • /
    • pp.71-74
    • /
    • 2000
  • 일반적으로 온실은 저온기에는 보온이나 난방을 하면서 적극 사용하고 있으나 고온기에는 냉방에 소요되는 에너지가 난방에 비해 상대적으로 많이 소요되므로 온실의 활용도가 떨어지게 된다. 자연환기 시스템은 에너지를 사용하지 않거나 최소한으로 줄여 온실내 온도를 최소한 외부와 동일하게 하거나 낮게 하기 위한 장치라고 할 수 있다. 자연환기를 위한 환기창으로 유리온실이나 경질판 온실과 같은 양지붕형 온실에서는 측창으로 3Way방식이나 권취식, 프로젝트방식 등 다양한 환기창을 사용하고 있으나 천창은 주로 온실 길이방향의 연속형 창틀을 랙앤피니언이나 X형 개폐암으로 개폐하는 프로젝트 방식을 많이 사용하고 있다. (중략)

  • PDF

A Numerical Study on Characteristics of Smoke Exhaust in Road Tunnel Fires for Different Ventilation System (터널 화재 시 환기 방식에 따른 배연 특성의 수치해석 연구)

  • Kim, Jong-Yoon;Yoo, Ji-Oh
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.201-207
    • /
    • 2008
  • In this study, three Dimensional CFD simulations were carried out to investigate the effective smoke extraction system in bi-directional road tunnel fires using FLUENT. Characteristics of transverse system with big size extraction port or with uniform extraction port, semi-transverse system and longitudinal system for smoke extraction system were analyzed. Air velocity, port size, and operating method were used with variable. Distributions of smoke spread, CO was analyzed. As a result, the transverse ventilation system with big size port was found to be more effective than the uniform ports for bi-directional road tunnel.

An Experimental Study on the Ventilation Performance to Enhance Removal Efficiency of Indoor Hamful Gases (실내 유해가스 제거효율 향상을 위한 환기성능에 관한 실험적 연구)

  • Ku, Jae-Hyun
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.117-124
    • /
    • 2009
  • The objective of this research is to analyze the ventilation performance of mechanical ventilation systems to enhance removal efficiency of indoor hamful gases. The ventilation performance is evaluated using a step-down method based on ASTM Standard E741-83. The ventilation performance is evaluated as a function of the ventilation rate and supply/extract locations using a tracer gas ($CO_2$) technique. As a result, the $CO_2$ concentration as a function of time is decayed exponentially and the ventilation performance is found to increase with increased the ventilation rate. The ventilation performance of the second type ventilation system is better than that of the first type or the third type. The ventilation performance without human occupancy increases up to 55% and the ventilation performance with one person increases up to 25% at the supply air of 570Lpm comparing with a natural reduction after one hour in the test chamber. The ventilation performance is better than 15% comparing with natural decay at the supply of 570Lpm in an office room.

에어컨용 열교환기의 고성능화 개발

  • 하야세 가쿠
    • Journal of the KSME
    • /
    • v.54 no.5
    • /
    • pp.49-53
    • /
    • 2014
  • 이 글에서는 에어컨용 열교환기의 고성능화에 관해서, 종래의 Fin & Tube방식부터 최신의 마이크로 채널 방식까지의 개발 사례를 소개하고자 한다.

  • PDF