• Title/Summary/Keyword: 환기기구

Search Result 62, Processing Time 0.027 seconds

통계자료

  • Korea Electronics Association
    • Journal of Korean Electronics
    • /
    • v.2 no.4
    • /
    • pp.65-77
    • /
    • 1982
  • PDF

A study on the program development for optimizing the supply and exhaust port opening ratio in road tunnels with transverse ventilation system (횡류식 도로터널의 급배기구 개도율 최적화 프로그램 개발 연구)

  • Jo, Hyeong-Je;Chun, Kyu-Myung;Min, Dea-Kee;Kim, Jong-Won;Beak, Jong-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.517-532
    • /
    • 2017
  • The transverse ventilation system, commonly applied to urban tunnel, is necessary to be distributed with airflow uniformly. In this study, we developed a program that can optimize the opening ratio of ports to ensure ventilation performance of design criteria through a uniform airflow distribution even though ventilation interval becomes longer. And program's prediction performance was verified by comparison with TUNVEN DUCT program. For comparison, Semi-transverse ventilation system was applied. Both programs predicted a similar port size and air flow distribution, and the variation range of the calculated values was 11.71% and 1.36%, respectively. This program is very useful for port optimization design of transverse and semi-transverse ventilation system, because it is possible to analyze various tunnel lengths and supply/exhaust port installation conditions.

Experimental Study on the Effect of the Area Ratio between Shaft and Tunnel and Heat Release Rate on the Plug-holing Phenomena in Shallow Underground Tunnels (저심도 도로터널에서 터널과 수직환기구의 단면적 비와 열방출률이 Plug-holing 현상에 미치는 영향에 관한 실험연구)

  • Hong, Kibea;Na, Junyoung;Ryou, Hong Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.619-625
    • /
    • 2019
  • It is difficult to design because of the plug-holing phenomenon in which the amount of smoke discharged from the vertical vent is smaller than the designed amount of smoke. In this study, the effect of cross-sectional area ratio of tunnel and natural ventilation and heat release rate of fire source on plug-holing phenomenon occurring in natural ventilation system was experimentally analyzed. In the experiment model reduced to 1/20 size, the aspect ratio of the tunnel and the vertical vent was fixed, and the influence on the plug-holing phenomenon was confirmed by varying the sectional area ratio of the tunnel and the vertical vent. Experimental results show that the plug-holing phenomenon is caused by the comparison of the smoke boundary layer temperature with the temperature in the vertical vents, and the flow and temperature distribution characteristics under the vertical vents are changed as the cross-sectional area ratio of the tunnel and vertical vents increases. The plug-holing phenomenon is affected by the cross-sectional area ratio between the tunnel and the vertical ventilation. The greater the cross-sectional area ratio, the greater the probability of plug-holing.

Time Course of $CO_2$ Exchange of Sweetpotato Cultures In Vitro with Different $CO_2$ Concentration under Forced Ventilation (고구마 조직배양묘의 $CO_2$교환량 연속 측정)

  • 오양숙;고재풍수;정순주
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1997.05a
    • /
    • pp.17-22
    • /
    • 1997
  • 본 연구에서는 고구마 조직배양묘의 $CO_2$ 교환량을 측정하기위해 개방형 광합성측정장치의 원리를 이용해 자체제작한 $CO_2$ 교환량 측정장치를 이용하여 공기 주입구와 배출구의 $CO_2$ 농도를 연속측정하고, 명기와 암기에 있어서의 $CO_2$ 교환량의 일변화를 분석했다. 내용적 1.48$\ell$의 배양기에 32개의 식물체를 이식했을 때 식물체당 일일 $CO_2$ 교환량은 19일째에 포화에 달했다. 식물체 생장에 있어서는 자연환기구보다 강제환기구의 생장이 촉진되었고, 강제환기구에서는 $CO_2$ 시용구가 무시용구보다 생장이 촉진되었다. 본 연구의 결과는 고구마 조직배양묘를 강제환기와 $CO_2$ 시용등 배양환경의 개선함으로써 순환과정을 거치지 않고 포장정식이 가능한 배양묘나 삽수의 생산이 가능함을 시사한다고 사료된다.

  • PDF

The Effect of Makeup Air on Kitchen Hoods (주방후드에서 보급공기의 영향)

  • 장경진
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.32 no.11
    • /
    • pp.63-68
    • /
    • 2003
  • 주방환기의 계획에 있어서 조리시 발생하는 오염물질을 적절히 배기시키는 것이 가장 중요하다. 기구의 배치와 발열량을 평가하고 후드의 위치와 종류 그리고 덕트직경과 경로를 결정하며 적정한 풍량을 제거하기 위한 배기팬을 선정한다. 그러나 일반적인 실내 공기밸런스 계획을 시행함에도 불구하고 배기된 체적에 해당하는 풍량을 보충 공급하는 방식에 대한 고려는 현재 상대적으로 부족한 상태이다.

  • PDF

A study on the operation characteristics of oversized exhaust port applicable to double-deck tunnel (복층터널에 적용 가능한 화재 연동형 대배기구 운영 특성 분석 연구)

  • Park, Jinouk;Yoo, Yongho;Kim, Yangkyun;Park, Byoungjik;Kim, Whiseong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.887-895
    • /
    • 2019
  • Recently, the number of underground road development projects has been increasing to solve traffic problems in the national capital region and metropolitan areas with intensified overcrowding, and there has been a tendency to plan underground roads by applying a double-deck tunnel technology that has advantages in constructability and economical efficiency. The double-deck tunnel has a structure where one excavation section is divided into two parts and used as up and down lines, and is mainly used as a road for small vehicles only due to its low floor height. In addition, due to the small cross-sectional area, it has characteristics different from those of general road tunnels in terms of ventilation and disaster prevention. In this regard, this study proposed an operational plan that applies an oversized exhaust system, which is one of semi-transverse ventilation systems, to small cross-sectional tunnels like double-deck tunnel with low floor height, and a comparative analysis between smoke exhaust characteristics according to the fire occurrence locations and oversized exhaust systems was conducted using the Fire Dynamics Simulator (FDS). The results showed that unlike uniform exhaust, intensive smoke exhaust using the oversized exhaust port maximized the delay effect of smoke diffusion and limited the smoke within 50 m above and below the fire point.

기술현황분석 - 쥴톰슨냉동 기술

  • Hong, Yong-Ju;Go, Jun-Seok;Kim, Hyo-Bong;Park, Seong-Je
    • 기계와재료
    • /
    • v.23 no.3
    • /
    • pp.156-163
    • /
    • 2011
  • 쥴톰순 냉동기는 스터링 냉동기, GM 냉동기, 스터링형 및 GM형 맥동관 냉동기 등 기계적 극저온냉동기에 비해 단순한 구조, 수 초의 급속한 냉각특성을 장점으로 중대형의 가스액화사이클 뿐만 아니라 적외선검출기의 급속냉각, 저온수술 등 다양한 분야에서 널리 사용되어지고 있다. 일반적으로 100K 이하의 작동온도 및 수 초 수준의 빠른 냉각을 요구하는 적외선검출기의 냉각을 위해서는 수 백기압 이상 고압의 질소 및 아르곤 가스를 사용하는 쥴톰슨 냉동기가 주로 사용되고 있다. 쥴톰슨 냉동기는 핀-관(fin-tube) 형태의 열교환기와 열교환기의 구조적 기반을 제공하는 멘드렐(mandrel), 쥴톰슨 노즐 등으로 구성되며, 열교환기의 열전달 성능 및 유량조절기구의 특성은 냉동기 저온부의 냉각온도, 냉각시간 및 운전시간에 큰 영향을 미친다.

  • PDF

A study on the effective fire and smoke control in transverse oversized exhaust ventilation (횡류식 선택대배기환기에서의 배연특성에 관한 연구)

  • Han, Sang-Pil;Jeon, Yong-Han
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.6
    • /
    • pp.451-462
    • /
    • 2011
  • The smoke control system plays the most important role in securing evacuation environment when a fire occurs in road tunnels. Smoke control methods in road tunnels are classified into two categories which are longitudinal ventilation system and transverse ventilation system. In this study it is intended to review the characteristics of smoke behavior by performing numerical analysis for calculating the optimal smoke exhaust air volume with scaled-model and simulation when a fire occurs in tunnels in which transverse ventilation is applied, and for obtaining the basic data required for the design of smoke exhaust systems by deriving optimal smoke exhaust operational conditions for various conditions. As a result of this study, when the critical velocity in the tunnel is 1.75 m/s and 2.5 m/s, the optimal smoke exhaust air volume has to be more than $173m^3/s$, $236m^3/s$ for the distance of the smoke moving which can limit the distance to 250 m. In addition, in case of uniform exhaust the generated smoke is effectively taken away if the two exhaust holes near the fire region are opened at the same time.

A Numerical Study on Characteristics of Smoke Exhaust in Road Tunnel Fires for Different Ventilation System (터널 화재 시 환기 방식에 따른 배연 특성의 수치해석 연구)

  • Kim, Jong-Yoon;Yoo, Ji-Oh
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.201-207
    • /
    • 2008
  • In this study, three Dimensional CFD simulations were carried out to investigate the effective smoke extraction system in bi-directional road tunnel fires using FLUENT. Characteristics of transverse system with big size extraction port or with uniform extraction port, semi-transverse system and longitudinal system for smoke extraction system were analyzed. Air velocity, port size, and operating method were used with variable. Distributions of smoke spread, CO was analyzed. As a result, the transverse ventilation system with big size port was found to be more effective than the uniform ports for bi-directional road tunnel.