• Title/Summary/Keyword: 확폭

Search Result 62, Processing Time 0.028 seconds

Numerical Analysis on the Estimation of Shock Loss for the Ventilation of Network-type Double-deck Road Tunnel (네트워크형 복층 도로터널 환기에서의 충격 손실 평가를 위한 수치해석적 연구)

  • Park, Sang Hoon;Roh, Jang Hoon;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.27 no.3
    • /
    • pp.132-145
    • /
    • 2017
  • Shock loss was not applied for the tunnel ventilation of road tunnel in the past. However, pressure losses due to the shock loss can be significant in network double-deck road tunnel in which combining and separating road structures exist. For the optimum ventilation design of network double-deck road tunnel, this study conducted 3D CFD numerical analysis for the shock loss at the combining and separating flows. The CFD model was made with the real-scale model that was the standard section of double-deck road tunnel. The shock loss coefficient of various combining and separating angles and road width was obtained and compared to the existing design values. As a result of the comparison, the shock loss coefficient of the $30^{\circ}$ separating flow model was higher and that of the two-lane combining flow model was lower. Since the combining and separating angles and road width can be important for the design of shock loss estimation, it is considered that this study can provide the accurate design factors for the calculation of ventilation system capacity. In addition, this study conducted 3D CFD analysis in order to calculate the shock loss coefficient of both combining and separating flows at flared intersection, and the result was compared with the design values of ASHRAE. The model that was not widened at the intersection showed three times higher at the most, and the other model that was widened at the intersection resulted two times higher shock loss coefficients.

Coupled Operation of the Lake Youngsan, Yeongam and Kumho for the Flood Stage Control in the Downstream of the Youngsan River (영산강 하류부 홍수위 조절을 위한 영산호-영암호-금호호 연계운영)

  • Kim, Dae Geun;Kim, Dong Ok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.3B
    • /
    • pp.277-284
    • /
    • 2010
  • To examine how the width of connecting channels, the width of the Kumho lock gate, and the opening/shutting criteria of the Yeongam connecting channel lock gate affect the flood stage of Lake Yeongsan, Lake Yeongam, and Lake Kumho, located in the lower reaches of the Yeongsan River, unsteady flood routing was performed by connecting the three lakes into a single interlinked system. The coupled operation of the three lakes was found to have little effect when the widths of the lock gates and the Yeongam and Kumho connecting channels are set at the current level. The most effective way to lower the water level in Lake Yeongsan was to widen the Yeongam connecting channel, but this caused the water level in Lake Yeongam to rise. To lower the increased water level in Lake Yeongam by utilizing the water storage capacity of Lake Kumho, it was necessary to widen both the Kumho lock gate and the Kumho connecting channel. It was found that the optimum opening/shutting criterion for the Yeongam connecting channel lock gate is approximately EL.(+)0.8 m under the simulated conditions used in this study and the criterion allows of maximal lowering of the water levels in Lake Yeongam and Lake Kumho while maintaining a near-constant water level in Lake Yeongsan.

Development of a Dynamic Offtracking Model on Horizontal Curve Sections (Based on Articulated Vehicles) (도로 평면곡선부에서 동적궤도이탈모형 개발에 관한 연구 (굴절차량을 중심으로))

  • 최재성;김우현
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.3
    • /
    • pp.115-128
    • /
    • 2002
  • Dislike the tangent sections, the horizontal curve sections of roads should be designed, considering several factors : one of such factors is widening. In other words, since widening results from that when a vehicle runs on the horizontal curve sections, the rear wheels of the vehicle run not along with tracks of the front wheels but out of that, such offtracking should be exactly investigated and reflected in design of the curve sections. Especially in the case of industrial roads which semi-trailers and large trucks run frequently or arterial roads with small curve radiuses in mountainous regions. serious offtracking Phenomenons result in increasing the risk of accidents. decreasing the capacities and jeopardizing pedestrians' safety on the curve sections. For the offtracking, widening amounts of roads has been determined under the traditional presumption that vehicles run at a low speed and there is no superelevation. In fact, however, since the vehicles run at a high speed as well as at a low speed and the superelevation is installed on the horizontal curve sections in the structural aspect of roads, the existing standards for installing widening have a limitation to reflect exactly actual Phenomenons. In particular, for articulated wheel axles of a tractor and a trailer and long articulated vehicles, not only the offtracking degree is very high but also the interpretation shows different aspects from one of single axles. Comparing and reviewing the results of Korean and foreign studies related to the trailer offtracking model theory and the standards for installing widening, this study developed a realistic dynamic offtracking model which considers geometric structures of roads and speeds of vehicles, suggested how to measure widening with this model and examined applicability of the model. The findings of this study are as follows ; First. a dynamic offtracking model. which considers dynamic movements of a tractor and a trailer and the superelevation, was developed. Second, a new method to measure widening with the developed dynamic offtracking model was developed and a method to measure widening with swept path width was suggested as well. Finally, validity of the current standards for installing widening was examined by determining actual offtracking and widening amounts with the developed model and the applicability was investigated through the case studies. Compared with the existing offtracking models, the dynamic offtracking model developed in this study can reflect practically vehicle speed. dimension and geometric structural aspects of roads. In conclusion, the meaning of this study is that it reviews validity of the current standards for installing widening and provides a base to establish such standards by suggesting new methods to measure the widening with this dynamic offtracking model.

A Numerical Analysis on the Determination of Shock Loss Coefficient at Flared Intersection of Network-type Double-deck Road Tunnel (네트워크형 복층 도로터널 확폭구간에서의 충격손실 계수 결정을 위한 수치해석 연구)

  • Park, Yo Han;Lee, Seung Jun;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.28 no.1
    • /
    • pp.111-124
    • /
    • 2018
  • The purpose of this study is to analyze ventilation design factor for network-type double-deck road tunnel that have been developed actively around the world. A numerical analysis was carried out through computational fluid dynamics (CFD) to derive shock loss coefficient that occurs due to the change in cross sectional area at both merging section and diverging section. The model used for the numerical analysis is real-scale model and the reliability of the result is secured by comparing with the coefficient of the previous studies. As a result of this study, shock loss coefficient was calculated depending on the change in cross-sectional area ratio and was higher than the result of previous studies in case of both merging section and diverging section. It is considered that the characteristics of the geometrical structure of network-type double-deck road tunnel have a great impact on shock loss coefficient. Therefore, the result of this study is expected to be helpful for more accurate ventilation design of network-type double-deck road tunnel.

Pseudo-Static Behaviors of U-shaped PSC Girder with Wide Flanges (확폭플랜지를 갖는 U형 프리스트레스 거더의 유사정적거동)

  • Rhee, In-Kyu;Lee, Joo-Beom;Kim, Lee-Hyeon;Park, Joo-Nam;Kwak, Jong-Won
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.993-999
    • /
    • 2008
  • A girder height limitation is the critical parameter for rapid construction of bridge deck and construction space limitation especially in urban area such as high population area and high density habitats. A standard post-tensioned I-shaped concrete girder usually demands relatively higher girder height in order to retain sufficient moment arm between compression force and tensile force. To elaborate this issue, a small U-shaped section with wide flanges can be used as a possible replacement of I-shaped standard girder. This prestressed concrete box girder allows more flexible girder height adjustment rather than standard I-shaped post-tensioned girder plus additional torsion resistance benefits of closed section. A 30m-long, 1.7m-high and 3.63m-wide actual small prestressed concrete box girder is designed and a laboratory test for its static behaviors by applying 6,200kN amount of load in the form of 4-point bending test was performed. The load-deflection curve and crack patterns at different loading stage are recorded. In addition, to extracting the dynamic characteristics such as natural frequency and damping ratio of this girder, several excitation tests with artificial mechanical exciter with un-symmetric mass are carried out using operational frequency sweep-up. Nonlinear finite element analysis of this 4 point bending test under monotonic static load is investigated and discussed with aids of concrete damaged plasticity formulation using ABAQUS program.

  • PDF

Reinforcement of shield tunnel diverged section with longitudinal member stiffness effect (종방향 부재의 강성효과를 고려한 쉴드 터널 분기부 보강 및 해석기법)

  • Lee, Gyu-Phil;Kim, Do
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.5
    • /
    • pp.675-687
    • /
    • 2019
  • In recent years, the needs for double deck-tunnels have increased in large cities due to the increase in traffic volume and high land compensation costs. In Korea, a network type tunnel which is smaller than general road tunnels and crosses another tunnel underground is planned. In the shield tunnel joints between the existing shield tunnel and the box-type enlargement section, a partial steel-concrete joint is proposed where the bending moment is large instead of the existing full-section steel joint. In order to analysis the enlargement section of the shield tunnel diverged section to reflect the three-dimensional effect, the two-dimensional analysis model is considered to consider the column effect and the stiffness effect of the longitudinal member. A two-dimensional analysis method is proposed to reflect the stiffness of the longitudinal member and the column effect of the longitudinal point by considering the rigidity of the longitudinal member as the elastic spring point of the connecting part in the lateral model. As a result of the analysis of the model using the longitudinal member, it was considered that the structural safety of the partial steel-concrete joint can be secured by reducing the bending moment of the joint and the box member by introducing the longitudinal member having the stiffness equal to or greater than a certain value.

Effects of Tidal Flat Enlargement Induced by Tidal Amplification (조석확폭에 수반되는 조간대 영역 확대의 영향성)

  • Kang Ju Whan;Moon Seung Rok;Park Seon Jung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.17 no.1
    • /
    • pp.47-54
    • /
    • 2005
  • A method has been developed, which can be handled easily and economically for inputting depth data of complex bathymetry and enourmous tidal flats such as Mokpo coastal zone. The method is applied to Chungkye Bay, and some hydrodynamic features related with tidal flat are analyzed. Tidal amplification by construction of the sea-dike and sea-walls had been detected not only near Mokpo Harbor but also at Chungkye Bay which is connected with Mokpo Harbor by a narrow channel. This brings about the increase of tidal flat area, which makes the ebb dominance at Chungkye Bay more seriously. This pronounced ebb dominance with the increase of tidal discharge at the channel between Chungkye Bay and Mokpo Harbor, which results in deepened ebb dominance near Mokpo Harbor as well.