• Title/Summary/Keyword: 확관

Search Result 46, Processing Time 0.024 seconds

An Experimental Study on Evaporative Heat Transfer Characteristics in Micro-Fin Tubes Before and After Expansion Process (마이크로핀관의 확관 전후 증발열전달 특성에 관한 실험적 연구)

  • 전상희;황윤욱;윤석호;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.10
    • /
    • pp.932-940
    • /
    • 2000
  • An experimental study on evaporative heat transfer characteristics in micro-fin tubes before and after expansion process has been performed with R-22. Single-grooved micro-fin tubes with outer diameter of 9.52 mm were used as test sections, and it was uniformly heated by applying direct current to the test tubes. Experiments were conducted at mass flow rates of 20 and 30 kg/hr. For each mass flow rate condition, evaporation temperature was set at 5 and $15^{\circ}C$and heat flux was changed from 6 to 11 kW/$m^2$ The evaporative heat transfer coefficient of micro-fin tubes after expansion is decreased because of the crush of fins and enlargement of inner diameter compared to that before expansion. Convective boiling effect decreased remarkably at higher quality range in the micro-fin tube after expansion, and the difference of the heat transfer coefficient in micro-fin tubes before and after expansion was greater for higher quality region. The evaporative heat transfer coefficient of the micro-fin tube after expansion was 19.9% smaller on the average than that before expansion.

  • PDF

Heat Transfer Characteristics of the Non-Uniform Grooved Tube Considering Tube Expansion (확관을 고려한 불균일 내면가공관의 전열특성)

  • Lee, Sang-Mu;Park, Byung-Duck
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.7
    • /
    • pp.553-559
    • /
    • 2012
  • A plate-fin heat exchanger is a type of heat exchanger widely used in air conditioners, and tubes and fins are tightly assembled by the mechanical expansion process of tubes. The tube expansion process deforms the grooves inside the tube, and the groove shapes also affect the adhesion between tubes and fins. In this study, the adhesion and heat transfer performance affected by the tube expansion of the non-uniform groove shape tube with different heights are investigated by both analysis and experiments. From the analysis method, it was shown that the contact pressure of non-uniform groove tube is higher than that of the uniform groove tube, and the most appropriate high groove number of the non-uniform groove tube is designed for the maximum contact pressure. From the experimental results, the decreasing rate of the condensation heat transfer coefficient is smaller in the non-uniform groove tube with different heights, compared to the conventional uniform groove tube. Also, the air-side heat transfer coefficient of the non-uniform groove tube with different heights is higher than that of the uniform groove tubes.

The Evaluation of Tube to Tubesheet Joint Part on Nuclear S/G (원자력 증기발생기 튜브/튜브시트 확관방법별 특성평가)

  • 심상한;배강국;김인수
    • Proceedings of the KWS Conference
    • /
    • 1996.05a
    • /
    • pp.34-37
    • /
    • 1996
  • The expanding method of tube to tubesheet joint part on neclear steam generators are classified into three classes of roller expanding, explosive expanding and hydraulic expanding. After the expanded Mock-Up specimen are made by the three expanding method. The general properties, microstructure/microvickers hardness, pull-out strength, hydraulic leak pressure, of tube to tubesheet joint part were inspected. and We evaluated the operation efficiency of expansion, reproduction of expanded joint about three expanding method. Through the overall evaluation of tube to tubesheet joint part, The hydraukic expanding and explosive expanding could be certificated more useful expanding method.

  • PDF

Residual Stress in U-Bending Deformations and Expansion Joints of Heat Exchanger Tubes (전열관의 굽힘 및 확관접합 잔류응력)

  • Jang, Jin-Seong;Bae, Gang-Guk;Kim, U-Gon;Kim, Seon-Jae;Guk, Il-Hyeon;Kim, Seong-Cheong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.2 s.173
    • /
    • pp.279-289
    • /
    • 2000
  • Residual stress induced in U-bending and tube-to-tubesheet joint processes of PWR's row-1 heat exchanger tube was measured by X-ray method and Hole-Drilling Method(HDM). Compressive residual stresses(-) at the extrados surface were induced in U-bending, and its maximum value reached -319 MPa in axial direction at the position of $\psi$ = $0^{\circ}$. Tensile residual stresses(+) of $\sigma_{zz}$ = 45 MPa and $\sigma_{\theta\theta}$ = 25 MPa were introduced in the intrados surface at the position of $\psi$ = $0^{\circ}$. Maximum tensile residual stress of 170 MPa was measured at the flank side at the position of $\psi$ = $90^{\circ}$, i.e., at apex region. It was observed that higher stress gradient was generated at the irregular transition regions (ITR). The trend of residual stress induced by U bending process of the tubes was found to be related with the change of ovality. The residual stress induced by the explosive joint method was found to be lower than that by the mechanical roll method. The gradient of residual stress along the expanded tube was highest at the transition region (TR), and the residual stress in circumferential direction was found to be higher than the residual stress in axial direction.

Development of Steam-Generator UT System and Experimental Verification (증기발생기 전열관 확관부의 초음파 검사장치 및 적용기술개발)

  • Park, Jae-Seok;Hong, Soon-Sin;Park, Chi-Seung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.5
    • /
    • pp.442-448
    • /
    • 2007
  • The ultrasonic inspection system for the expansion/transition area of steam generator tube was successfully developed. Variety of artificial flaw and real track specimen was tested using the UT system to verify the performance of the system. All artificial flaws of which through-wall depth larger than 10% was clearly detected by UT system. Measurement results of through-wall depth of flaws larger than 20% had good linearity and reproducibility with 3.27 of standard deviation. Results of real crack specimen test suggested that the detection limit of real crack strongly depends on the track morphology. A potential for measurement of PRL(percentage of remaining ligament) was recognized by the real crack specimen test.

A Study on the Exhaust Gas Recirculation in a MILD Combustion Furnace by Using the Coanda Nozzle Effect (MILD 연소로에서 Coanda 노즐 효과를 이용한 배기가스 재순환에 관한 연구)

  • Ha, Ji Soo;Shim, Sung Hoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.967-972
    • /
    • 2013
  • A MILD (Moderate and Intense Low oxygen Dilution) combustion, which is effective in the reduction of NOx, is considerably affected by the recirculation flow rate of hot exhaust gas to the combustion furnace. The present study used the MILD combustor, which has coaxial cylindrical tube. The outside tube of the MILD combustor corresponds to the exhaust gas passage and the inner side tube is the furnace passage. A numerical analysis was accomplished to elucidate the characteristics of exhaust gas entrainment toward the inner furnace with the changes of coanda nozzle geometrical parameters, nozzle passage gap length, nozzle passage length, nozzle angle and expansion length. The optimal configuration of coanda nozzle for the best entrainment flow rate was gap length, 0.5 mm, expansion angle, 4o and expansion length, 146 mm. The nozzle passage length was irrelevant to the exhaust gas entrainement.

Experimental investigation of friction in expansion zone of tube hydroforming with material and lubricant (튜브 액압성형 공정의 확관영역에서 소재 및 윤활에 따른 마찰 특성의 실험적 연구)

  • Lee, G.Y.;Yim, H.S.;Lee, S.M.;Yi, H.K.;Chung, G.S.;Moon, Y.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.359-362
    • /
    • 2008
  • In this study, friction test was proposed to obtain coefficient of friction between tube and die in expansion zone of tube hydroforming and friction coefficients were evaluated at different materials, viscosity of lubricants and internal pressures. For this study, STKM11A and SUS tubes were prepared. The tube was expanded by an internal pressure against the tool wall. The tube was expanded by an internal pressure against the tool wall. By pushing the tube through the tool, a friction force at the contact surface between the tube and the tool occurs. From the measured geometries and FE analysis, the friction coefficients between tube and die at the expansion zone in tubular hydroforming can be estimated. The effects of the various internal pressures, viscosity of lubricants, tube materials and tube thickness on friction coefficients are discussed.

  • PDF

Sensitivity Analysis on Hydraulic Expanded Tube-to-Tubesheet Joints for Tube Layout Patterns (튜브 배열에 따른 튜브/튜브시트 수압 확관 접합의 민감도 해석)

  • Kim, Dong-Yeong;Kim, Tae-Wan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.11 s.170
    • /
    • pp.1896-1903
    • /
    • 1999
  • The basic requirements to improve the joints quality of tube-to-tubesheet for heat exchangers are to obtain high residual contact pressures between the tubes and the tubesheet as well as low residual stresses in the transition zone of the tubes. The residual contact pressures and residual stresses which govern the joint quality are influenced by parameters such as material properties, geometric dimension of tube and tubesheet and expansion pressures. There are two types of tube layout patterns, triangular and square, which are frequently used for heat exchangers. The purpose of the present work is to examine the superior tube layout patterns considering the joints quality by comparing numerical results from sensitivity analyses which were performed for both of tube layout patterns.

반경 방향 집합조직을 가진 압력관에서의 $K_{IH}$

  • 김성수;주기남;안상복;권상철;김영석;국일현
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.93-98
    • /
    • 1998
  • CANDU 압력관의 집합조직을 원주 방향 집합조직에서 반경 방향 집합조직으로 변화시켜 $K_{IH}$ 를 평가하였다. 집합조직은 평면 변형에 의한 25% 확관 방법으로 번화시켰고 (0002) direct pole figure와 basal pole component (기저면 성분, Kearns number)로 분석하였다. 반경 방향집합조직의 압력관의 $K_{IH}$ 는 2$50^{\circ}C$에서 17MPa√m 이상으로 나타났으며, 이것은 상용 압력관의 $K_{IH}$ =8-10 MPa√m보다 70% 이상 높은 값이다. 반경 방향 집합조직의 압력관에서 나타나는 $K_{IH}$ 거동을 균열 진전면에서의 기저면 성분과 연계하여 분석하였으며, 평면 면형에 따른 집합조직의 변화는 슬립과 쌍정 기구의 작용으로 설명하였다. 본 연구의 결과는 CANDU 압책관의 delayed hydride cracking (DHC) 저항성 관점에서 반경 방향으로 집합조직을 제어하면 매우 효율적이라는 것을 보여 준다.

  • PDF

A Comparative Study of Heat Pipes with Enlarged Condenser Section for Evacuated Solar Collectors (확관 응축부를 갖는 진공관형 태양열 집열기용 히트파이프 성능 비교 연구)

  • Boo, Joon-Hong;Chung, Won-Bok;Kwak, Hee-You
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.4
    • /
    • pp.18-25
    • /
    • 2002
  • For application to medium temperature solar collerctors $(80\sim120^{\circ}C)$, a heat pipe should be designed properly to efficiently transfer heat to a hotter condenser than common applications. Among many wick structure candidates for heat pipes of this type, a slab wick was selected based on promising performance data reported previously. The thermal performance of slab wick heat pipes, screen wick heat pipes and thermosyphons with enlarged condenser section were experimentally investigated for comparison purpose. The heat pipes were 8.0 mm O.D. (evaporator section) and 25.4 mm O.D. (condenser section) made of copper. The experimental data of the heat pipes were analysed in terms of thermal resistance against thermal load and coolant temperature.