• Title/Summary/Keyword: 화학공장

Search Result 514, Processing Time 0.034 seconds

Changes of Chemical Composition and Microflora in Commercial Kimchi (시판 김치의 발효 온도별 성분과 미생물 변화)

  • Shin, Dong-Hwa;Kim, Moon-Sook;Han, Ji-Sook;Lim, Dae-Kwan;Bak, Wan-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.137-145
    • /
    • 1996
  • Chemical changes, lactic acid bacteria and yeast counts in kimchi prepared by a commercial manufacturer in large scale were monitored at different fermentation temperature. The optimum pH of kimchi, around pH 4.2, reached within 2 days at $25^{\circ}C$, 3 days at $15^{\circ}C$ and 23 days at $5^{\circ}C$ fermentation, respectively. The optimum acidity calculated as lactic acid was not exactly coincident with pH. The total viable count reached at maximum within 2 days at $25^{\circ}C$, 6 days at $15^{\circ}C$ and 12 days at $5^{\circ}C$ fermentation, respectively. The identified strains of Lactobacilli during kimchi fermentation were L. brevis, L. plantarum and L. acidophilus with 3 unidentified strains. L. brevis, L. plantarum appeared from the first stage of fermentation to the terminal at $15^{\circ}C$ and $25^{\circ}C$ with keeping a constant level of viable number. In case of Leuconostoc species, L. mesenteroides subsp. mesenteroides was identified. This strain increased in viable number at the beginning of fermentation and dropped sharply at all fermentation temperatures. Pediococcus species including P. pentosaceus and one unidentified strain increased at the first stage of fermentation and decreased after on. Streptococcus faecium subsp. casseliflavus which appeared at the middle stage and Aerococcus viridans which was sole strain were also confirmed during kimchi fermentation. Cryptococcus laurenti was identified at all fermentation temperature and disappeared at the first stage of fermentation. It was reappeared 10 days only after fermentation at $25^{\circ}C$.

  • PDF

The Recycling of Sludge from Granite Stone Cutting and Polishing (화강암 석재 가공 슬러지의 재활용)

  • 이성오;국남표;임영빈;신방섭
    • Resources Recycling
    • /
    • v.4 no.1
    • /
    • pp.12-19
    • /
    • 1995
  • This study was carried out to remove the iron and impurities usmg hydrocyclone and HGMS for recycling of sludge from the granite stone cutting and polishing industrγ in the basic of chemi떠1 analysis and minerallogical investigation. This sludge consist of 70.9% $SiO_2$ 13.6% $Al_2O_3$ and It also contained 2.52% of $Fe_2O_7$ and 0.29% of $TiO_2$, as a main impurities to decrease the whiteness. As the result of hydrocyclone experiment, It was very good condition that are 100~150 g/l of sludge amount, 2.0~ 2.5 mm of underflow nozzle size, and 1.2~1.6 kg/$\textrm{cm}^2$ of pressure for 85% sludge product with the $-37{\mu}\textrm{m}$ size. $Fe_2O_3$ and $TiO_2$, contents by treatment of HGMS were decreased with 0.65% and 0.07% each at 10,000 gauss of magnetic field strength, and addih$\upsilon$n of Sodium tripolyphosphate as a dispersant was effected to get low grade F Fe,Ol and TiO, concentrate. PhYSIcal properties of this stone sludge product were showed 58.5% of whiteness, 1 13.4% of firing shrinkage and 3.0812 $\textrm{m}^2$/g of specific surface area.

  • PDF

Eco-Industrial Park (EIP) Development and Key Technologies for Clean Production (청정 생산을 위한 생태산업단지 구축과 주요기술)

  • Yoo, ChangKyoo;Heo, Soon-Ki;Yoo, Dong Joon;Lee, SeungJun;Shin, Ji Na;Park, Yong Joon;Yoon, Hack Mo;Chun, Hee Dong;Moon, Jeong Ki;Lee, In-Beum
    • Korean Chemical Engineering Research
    • /
    • v.43 no.5
    • /
    • pp.549-559
    • /
    • 2005
  • Sustainable industrial development which can minimize an ecological effect by the mankind exertion is recently interested due to an environmental contamination and a resource exhaustion problem. An eco-industrial park (EIP) is a community of manufacturing and service businesses seeking enhanced environmental and economic performance through collaboration in managing environmental and resource issues, including energy, water, and materials. EIP developments which improve a production plant within an eco-friendly greenfield and design a new industrial ecosystem are accomplished recently, which can efficiently re-use the waste and resources from each company within EIP. In this review, the outside and domestic case studies of EIP and cornerstone technologies to develop the EIP, such as energy integration, waste reuse, mass flow analysis, water pinch, and life cycle assessment, are summarized.

Prediction of Lifetime of Steel Bridge Coating on Highway for Effective Maintenance (고속도로 강구조물의 효율적 유지관리를 위한 도막수명예측)

  • Lee, Chan-Young;Cheong, Haimoon;Park, Jin-Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3A
    • /
    • pp.341-347
    • /
    • 2008
  • Among coating systems used for steel bridge coatings on highway such as red lead-pigmented alkyd, chlorinated rubber, waterborne inorganic zinc, inorganic zinc/epoxy/urethane and inorganic zinc/epoxy/fluororesin, evaluation of deterioration degree and prediction of lifetime through regression analysis were carried out for coating systems widely used and grossly degraded. For evaluation of deterioration degree, 75 bridges on highway were selected, and evaluations were carried out according to point offering method regulated by Guideline of maintenance coating for steel bridges used in Korea Expressway Corporation. Lifetime prediction results showed 13.0~13.3 years for the whole nation, 11.8 years for urban and industrial region in the metropolitan area, 13.2 years for rural region except the metropolitan area, 13.5~13.7 years for chlorinated rubber coating systems, and 12.86 years for red lead-pigmented alkyd systems. For prediction of the rest life of coating, we tried to execute parallel translations of standard deterioration curve to current life and deterioration degree for both x and y axes, and it was thought that parallel translation for x axis corresponded to deterioration aspects in actual environment. Maximum and minimum equations were derived from standard deterioration equation by adding and subtracting error values deduced in regression analysis to/from each coefficient in order to establish maintenance coating criteria for overall steel bridges on highway. Whole domain was divided into 8 parts in order to predict the rest life of coating and optimum time of maintenance coating, and maintenance coating criteria for each 8 domains were presented.

Dynamic Shear Behavior Characteristics of PHC Pile-cohesive Soil Ground Contact Interface Considering Various Environmental Factors (다양한 환경인자를 고려한 PHC 말뚝-사질토 지반 접촉면의 동적 전단거동 특성)

  • Kim, Young-Jun;Kwak, Chang-Won;Park, Inn-Joon
    • Journal of the Korean Geotechnical Society
    • /
    • v.40 no.1
    • /
    • pp.5-14
    • /
    • 2024
  • PHC piles demonstrate superior resistance to compression and bending moments, and their factory-based production enhances quality assurance and management processes. Despite these advantages that have resulted in widespread use in civil engineering and construction projects, the design process frequently relies on empirical formulas or N-values to estimate the soil-pile friction, which is crucial for bearing capacity, and this reliance underscores a significant lack of experimental validation. In addition, environmental factors, e.g., the pH levels in groundwater and the effects of seawater, are commonly not considered. Thus, this study investigates the influence of vibrating machine foundations on PHC pile models in consideration of the effects of varying pH conditions. Concrete model piles were subjected to a one-month conditioning period in different pH environments (acidic, neutral, and alkaline) and under the influence of seawater. Subsequent repeated direct shear tests were performed on the pile-soil interface, and the disturbed state concept was employed to derive parameters that effectively quantify the dynamic behavior of this interface. The results revealed a descending order of shear stress in neutral, acidic, and alkaline conditions, with the pH-influenced samples exhibiting a more pronounced reduction in shear stress than those affected by seawater.

A study on damage prediction analysis for styrene monomer fire explosion accidents (스티렌 모노머 화재폭발사고 피해예측 분석에 관한 연구)

  • Hyung-Su Choi;Min-Je Choi;Guy-Sun Cho
    • Industry Promotion Research
    • /
    • v.9 no.2
    • /
    • pp.37-44
    • /
    • 2024
  • This study selected the worst-case scenario for fireball and vapor cloud explosion (VCE) of a styrene monomer storage tank installed in a petrochemical production plant and performed damage prediction and accident impact analysis. The range of influence of radiant heat and overpressure due to fireball and vapor VCE during the abnormal polymerization reaction of styrene monomer, the main component of the mixed residue oil storage tank, was quantitatively analyzed by applying the e-CA accident damage prediction program. The damage impact areas of radiant heat and explosion overpressure are analyzed to have a maximum radius of 1,150m and 626m, respectively. People within 1,150m of radiant heat of 4kW/m2 may have their skin swell when exposed to it for 20 seconds. In buildings within 626m, where an explosion overpressure of 21kPa is applied, steel structures may be damaged and separated from the foundation, and people may suffer physical injuries. In the event of a fire, explosion or leak, determine the risk standards such as the degree of risk and acceptability to workers in the work place, nearby residents, or surrounding facilities due to radiant heat or overpressure, identify the hazards and risks of the materials handled, and establish an emergency response system. It is expected that it will be helpful in establishing measures to minimize damage to workplaces through improvement and investment activities.

Development of Algorithm for Vibration Analysis Automation of Rotating Equipments Based on ISO 20816 (ISO 20816 기반 회전기기 진동분석 자동화 알고리즘 개발)

  • JaeWoong Lee;Ugiyeon Lee;Jeongseok Oh
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.2
    • /
    • pp.93-104
    • /
    • 2024
  • Facility diagnosis is essential for the smooth operation and life extension of rotating equipment used in industrial sites. Compared to other diagnostic methods, vibration diagnosis can find most of the initial defects, such as unbalance, alignment failure, bearing defects and resonance, compared to other diagnostic methods. Therefore, vibration analysis is the most commonly used facility diagnosis method in industrial sites, and is usefully used as a predictive preservation (PdM) technology to manage the condition of the facility. However, since the vibration diagnosis method is performed based on experience based on the standard, it is carried out by experts. Therefore, it is intended to contribute to the reliability of the facility by establishing a system that anyone can easily judge defects by establishing a vibration diagnosis method performed based on experience as a knowledgeable code system. An algorithm was developed based on the ISO-20816 standard for vibration measurement, and the reliability was verified by comparing the results of vibration measurement at various demonstration sites such as petrochemical plant compressors, hydrogen charging stations, and industrial machinery with the results of analysis using a development system. The developed algorithm can contribute to predictive maintenance (PdM) technology that anyone can diagnose the condition of the rotating machine at industrial sites and identify defects early to replace parts at the exact time of replacement. Furthermore, it is expected that it will contribute to reducing maintenance costs and downtime due to the failure of rotating machines when applied to various industrial sites such as oil refining facilities, transportation, production facilities, and aviation facilities.

The Signal Transduction Mechanisms on the Intestinal Mucosa of Rat Following Irradiation (방사선조사후 백서소장점막에서 발생하는 신호전달체계에 관한 연구)

  • Yoo Jeong Hyun;Kim Sung Sook;Lee Kyung Ja;Rhee Chung Sik
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.79-95
    • /
    • 1997
  • Purpose : Phospholipase C(PLC) isozymes play significant roles in signal transduction mechanism. $PLC-\gamma$ 1 is one of the key regulatory enzymes in signal transduction for cellular proliferation and differentiation. Ras oncoprotein, EGFR, and PKC are also known to be involved in cell growth. The exact mechanisms of these signal transduction following irradiation, however, were not clearly documented Thus, this study was Planned to determine the biological significance of PLC, ras oncoprotein, EGFR, and PKC in damage and regeneration of rat intestinal mucosa following irradiation. Material and Method : Sixty Sprague-Dawley rats were irradiated to entire body with a single dose of 8Gy. The rats were divided into S groups according to the sacrifice days after irradiation. The expression of PLC, ras oncoprotein, EGFR and PKC in each group were examined by the immunoblotting and immunohistochemistry. The histopathologic findings were observed using H&I stain, and the mitoses for the evidence of regeneration were counted using the light microscopy & PCNA kit. The Phosphoinositide(PI) hydrolyzing activity assay was also done for the indirect evaluation of $PLC-\gamma$ 1 activity. Results: In the immunohistochemistry , the expression of $PLC-{\beta}$ was negative for all grøups. The expression of $PLC-{\gamma}1$ was highest in the group III followed by group II in the proliferative zone of mucosa. The expression of $PKC-{\delta}1$ was strongly positive in group 1 followed by group II in the damaged surface epithelium. The above findings were also confirttled in the immunoblotting study. In the immunoblotting study, the expressions of $PLC-{\beta}$, $PLC-{\gamma}1$, and $PKC-{\delta}1$ were the same as the results of immunohis-tochemistry. The expression of ras oncoprctein was weakly positive in groups II, III and IV. The of EGFR was the highest in the group II, III, follwed by group IV and the expression of PKC was weakly positive in the group II and III. Conclusion: $PLC-{\gamma}1$ mediated signal transduction including ras oncoprotein, EGFR, and PKC play a significant role in mucosal regeneration after irradiation. $PLC-{\delta}1$ mediated signal transduction might have an important role in mucosal damage after irradiation. Further studies will be necessary to confirm the signal transduction mediating the $PKC-{\delta}1$.

  • PDF

A Study on the Prevalence and Risk Factors of Liver Dysfunction among the Workers in Chemical Factories (화학공장 근로자들의 간기능 이상 유병률 및 위험인자에 관한 연구)

  • Cheong, Hae-Kwan;Kim, Joung-Soon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.1 s.56
    • /
    • pp.103-128
    • /
    • 1997
  • The object of this study is to evaluate the possibility of chemical-induced liver disorder among workers exposed to various chemicals and to classify the the liver function abnormalities by causes and to analyse the risk factors for each liver disorders. A cross-sectional study including questionnaire survey, physical examination, laboratory tests and ultrasonography of liver was conducted on 1,126 workers, 459 workers in a coal chemical plant(company A) and 667 workers in an insulation material manufacturing factory(company B). An industrial hygienist reviewed the chemicals used in both companies and evaluated the work environments to classify the workers by chemical exposure semiquantitatively. The results are as follows: 1. Of 459 workers in company A, 83 workers(18.1%) are classified as nonexposed, group 163(35,5%) as short-term exposure group, 155(33.8%) as intermediately exposed group and 58(12.6%) as long-term exposed group bared on the mean daily exposure to hepatotoxic chemicals evaluated by an industrial hygienist. Of 667 workers in company B, 484(72.6%) workers were classified as nonexposed and 183(35.5%) as exposed group. 2. Workers with SGOT level higher than 40 IU/l were (10.0%) in company A and 77(11.5%) in company 3, and those with SGPT level higher than 35 IU/l were 118(25.7%) in company A and 198(29.7%) in company B. The differences were not significant between companies and between exposure groups(p>0.05). Workers with $\gamma-GT$ level higher than 62 IU/l were 29(6.3%) in company A and 77(11.5%) in company B (p<0.01). The difference between exposure groups was not significant(p>0.05) within companies. Workers with liver function abnormalities(defined as SGOT higher than 40 IU/l or SGPT higher than 35 IU/l) were 338(30.0%) among 1,126 workers. Of 338 workers with live. function abnormalities 139(12.3%) had fatty liver by ultrasonography, 79(7.0%) had alcoholic liver(defined as workers with liver function abnormalities with weekly alcohol consumption greater than 280 g for more than 5 years), 54(4.8%) had hepatitis B, 12(1.1%) had hepatitis C and the other 114(33.7%) was not otherwise classified. Prevalences of alcoholic liver and fatty liver were significantly lower in company A(prevalence ratio 0.24 for alcoholic liver, p<0.001, prevalence ratio 0.76 for fatty liver, p<0.05) but prevalences of liver disorders between exposure groups within companies were not significant(p>0.05). 3. Summary prevalence ratios(SPR) of live. function abnormalities, fatty live. and other liver disorders, adjusted by age and company were not significantly higher in exposed group in any chemicals(p>0.05) but in some chemicals, SPRs were significantly lower. 4. On simple analysis of risk factors for liver function abnormalities, prevalence odds ratio(POR) of those with age between 30 and 39 was 1.54(p<0.01) and those with age ever 40 was 1.51(p<0.01). POR of those with histories of liver disorders and general anesthesia was 1.77(p<0.001) and 4.02 for those with overweight and 6.23 for those with obesity, defined by body mass index(p<0.001). 5. On logistic regression analysis, risk factors of liver function abnormality were fatty liver(POR 2.92 for grade 1, 12.15 for grade 2), presence of hepatitis B surface antigen(POR 3.62) and obesity(POR 5.38 for overweight and 16.52 for obesity). Presence of hepatitis B surface antigen(POR 0.18) was the only preventive facto. of fatty live. Company(POR 0.30) and obesity(POR 2.49 for overweight, 4.52 for obesity) were related to the alcoholic live. Obesity(POR 2.94 for overweight) was the only significant risk factor of hepatitis B and there was no significant risk factor for liver function abnormality not otherwise classified. It is concluded that the evidence of liver disorder related with chemical exposure is not evident in these factories. It is also postulated that fatty liver and alcoholic liver is most common causes of liver function abnormalities among workers and effort for weight control and improvement of life style should be done.

  • PDF

Quantitative Analysis of Magnetization Transfer by Phase Sensitive Method in Knee Disorder (무릎 이상에 대한 자화전이 위상감각에 의한 정량분석법)

  • Yoon, Moon-Hyun;Sung, Mi-Sook;Yin, Chang-Sik;Lee, Heung-Kyu;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.98-107
    • /
    • 2006
  • Magnetization Transfer (MT) imaging generates contrast dependent on the phenomenon of magnetization exchange between free water proton and restricted proton in macromolecules. In biological materials in knee, MT or cross-relaxation is commonly modeled using two spin pools identified by their different T2 relaxation times. Two models for cross-relaxation emphasize the role of proton chemical exchange between protons of water and exchangeable protons on macromolecules, as well as through dipole-dipole interaction between the water and macromolecule protons. The most essential tool in medical image manipulation is the ability to adjust the contrast and intensity. Thus, it is desirable to adjust the contrast and intensity of an image interactively in the real time. The proton density (PD) and T2-weighted SE MR images allow the depiction of knee structures and can demonstrate defects and gross morphologic changes. The PD- and T2-weighted images also show the cartilage internal pathology due to the more intermediate signal of the knee joint in these sequences. Suppression of fat extends the dynamic range of tissue contrast, removes chemical shift artifacts, and decreases motion-related ghost artifacts. Like fat saturation, phase sensitive methods are also based on the difference in precession frequencies of water and fat. In this study, phase sensitive methods look at the phase difference that is accumulated in time as a result of Larmor frequency differences rather than using this difference directly. Although how MT work was given with clinical evidence that leads to quantitative model for MT in tissues, the mathematical formalism used to describe the MT effect applies to explaining to evaluate knee disorder, such as anterior cruciate ligament (ACL) tear and meniscal tear. Calculation of the effect of the effect of the MT saturation is given in the magnetization transfer ratio (MTR) which is a quantitative measure of the relative decrease in signal intensity due to the MT pulse.

  • PDF