• Title/Summary/Keyword: 화질 평가

Search Result 614, Processing Time 0.043 seconds

Optimization of Image Quality according to Sensitivity and Tube Voltage in Chest Digital Tomosynthesis (디지털 흉부단층합성검사에서 감도와 관전압 변화에 따른 영상 최적화)

  • Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.541-547
    • /
    • 2018
  • To evaluate the effect of dose and image quality for Chest Digital Tomosynthesis(CDT) using sensitivity and tube voltage(kV). CDT images of the phantom were acquired varying sensitivity 200, 320, 400 according to set tube voltage of 125 kV and 135 kV. The dose and Dose Area Product(DAP) according to change of sensitivity and kV were evaluated and Image quality was evaluated by PSNR, CNR, SNR using Image J. Dose were lowered 14~23% less than sensitivity 200, 125 kV and DAP were lowered 13~26% less than sensitivity 200, 125 kV. PSNR were over 27 dB, which were significant value and CNR, SNR were better as sensitivity value was lower. But there were different statistical significant to each item. CNR and SNR were not statistically significant at sensitivity 320, 135 kV(P>0.05). CDT can improve image quality with lower radiation dose using better than quality and correction power at digital radiography system.

Subjective Evaluation of Image Quality on Digital Image Processing of Chest CR Image (CR 영상의 디지털 영상처리에 관한 주관적 화질 평가)

  • Lee, Yong-Gu;Lee, Won-Seok
    • 전자공학회논문지 IE
    • /
    • v.48 no.1
    • /
    • pp.51-56
    • /
    • 2011
  • In this paper, a variety of digital image processing technique was applied to improve the quality of medical images which is a chest CR image. And the image quality was performed. On the other hand, the high-frequency emphasis filtering and the histogram equalization were realized by MATLAB programs to better the contrast of the chest CR image. As a result of simulation, the sharpness of the original image was elevated by the high-frequency emphasis filtering and the histogram equalization. To evaluate the degree which is improved the image quality by the digital image processing, the subjective evaluation is used by the observation of the image. The sensitivity which is the probability to find a signal or a lesion is calculated. The sensitivity of the image performed the high-frequency emphasis filtering and the histogram equalization became more improved than that of the original and the digital image processing performed in the medical image improved the quality of the image.

The Evaluation of Eye Dose and Image Quality According to The New Tube Current Modulation and Shielding Techniques in Brain CT (두부 CT에서 차폐기법과 새로운 관전류변조기법에 따른 눈의 선량과 화질평가)

  • Kwon, Soonmu;Kim, Jungsu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.279-285
    • /
    • 2015
  • The eye of human is a radiation sensitive organ and this organ should be shielded from radiation exposure during brain CT procedures. In the brain CT procedures, bismuth protector using to reduce the radiation exposure dose for eye. But protecting the bismuth always accompanies problem of the image quality reduction including artifact. This study aim is the eye radiation exposure dose and image quality evaluation of the new tube current modulation such as new organ based-tube current modulation, longitudinal-TCM, angular-TCM between shielding scan technique using bismuth and lead glasses. As a result, radiation dose of eye is reduced 25.88% in new OB TCM technique then reference scan technique and SNR new OB TCM is 6.05 higher than bismuth shielding scan technique and lower than reference scan technique. In clinical brain CT, new OB TCM technique will contribute to reduction of radiation dose for eye without decrease of image quality.

The Additional Filter and Ion Chamber Sensor Combination for Reducing Patient Dose in Digital Chest X-ray Projection (디지털 흉부엑스선 검사에서 환자선량 감소를 위한 부가필터와 Ion chamber 센서 조합)

  • Lee, Jinsoo;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.3
    • /
    • pp.175-181
    • /
    • 2015
  • In this paper, we studied additional filter and Ion chamber combinations to reduce patient dose without decreasing image quality in digital chest x-ray projection. The experiment set 125 kVp, 320 mA, AEC mode. Ion chamber sensors was divided by 4 cases of combinations, then, we measured patient dose and calculated organ dose using PCXMC. Also, physical image assessment using MTF was performed. As a results, The surface entrance dose and organ dose were the lowest when selecting both left and right Ion chamber sensors under the same conditions of additional filter. In image quality assessment, The spatial frequency scored 2.494 lp/mm which was highest when selecting both right and left Ion-chambers and 0.1 mmCu filter. And to conclude, to select both right and left Ion chamber sensors and 0.1 mmCu filter will help for acquiring good quality image as well as reducing patient dose.

Adaptive Video Enhancement Algorithm for Military Surveillance Camera Systems (국방용 감시카메라를 위한 적응적 영상화질 개선 알고리즘)

  • Shin, Seung-Ho;Park, Youn-Sun;Kim, Yong-Sung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.1
    • /
    • pp.28-35
    • /
    • 2014
  • Surveillance cameras in national border and coastline area often occur the video distortion because of rapidly changing weather and light environments. It is positively necessary to enhance the distorted video quality for keeping surveillance. In this paper, we propose an adaptive video enhancement algorithm in the various environment changes. To solve an unstable performance problem of the existing method, the proposed method is based on Retinex algorithm and uses enhanced curves which is adapted in foggy and low-light conditions. In addition, we mixture the weighted HSV color model to keep color constancy and reduce noise to obtain clear images. As a results, the proposed algorithm improves the performance of well-balanced contrast enhancement and effective color restoration without any quality loss compared with the existing algorithm. We expect that this method will be used in surveillance camera systems and offer help of national defence with reliability.

Development of a Method for Measuring Image Quality of Intra Vascular Ultrasound Images using Image Analysis Program (영상 분석 프로그램을 이용한 혈관 내 초음파 영상의 화질 측정 방법 고안)

  • Seo, Young-Hyun;Han, Jae-Bok;Song, Jong-Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.621-628
    • /
    • 2021
  • Prior studies on frequency-related image quality analysis of intravascular ultrasound catheters are lacking both in Korea and abroad. Therefore, this study was conducted to prepare a standard for measuring the image quality using the program and to suggest a measuring method to researchers related to the quality analysis of intravascular ultrasound images. For the target, the vessel lumen size is 3.0 - 4.0 mm. Before using intravascular ultrasound, thoroughly clean the ultrasound catheter so that no air or foreign substances enter it. Normal vascular images and lesion vascular images of sufficiently dilated images were used. As a standard image acquisition method, the image of the end-systolic section, which has the best evaluation of vascular lesions when using intravascular ultrasound, was acquired retrospectively through the DCAS PACS program to set the standard. When setting the measurement method criteria, we proposed a standard setting method that corresponds to the concentric and eccentric circles of normal and lesion vessels. By applying this criterion, we proposed a method for measuring the lumen and lateral cavities of normal and lesion vessels of interest and background area. In conclusion, if the image quality of intravascular ultrasonography is measured through the method devised by these researchers, consistent quality measurement is possible regardless of the type of intravascular ultrasound catheter. Therefore, it is thought that it can be applied as a guideline for the actual image quality measurement method in the study related to intravascular ultrasound image quality.

Clinical Utility of Turbo Contrase-Enhanced MR Angiography for the Major Branches of the Aortic Arch (대동맥궁 주요 분지들의 고속 조영증강 자기공명혈관조영술의 임상적 유용성)

  • Su Ok Seong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.96-103
    • /
    • 1998
  • Purpose : To assess the clinical utility of turbo contrast-enhanced magnetic resonance angiography(CE MRA) in the evaluation of the aortic arch and its major branches and to compare the image quality of CE MRA among different coils used. Materials and Methods : Turbo three-phase dynamic CE MRA encompassing aortic arch and its major branches was prospectively performed after manual bolus IV injection of contrast material in 29 patients with suspected cerebrovascular diseases at 1.0T MR unit. the raw data were obtained with 3-D FISH sequence (TR 5.4ms, TE 2.3ms, flip angle 30, slab thickness 80nm, effective slice thickness 4.0mm, matrix size $100{\times}256$, FOV 280mm). Total data acquisition time was 4. to 60 seconds. We subjectively evaluated the imge quality with three-rating scheme : "good" for unequivocal normal finding, "fair" for relatively satisfactory quality to diagnose 'normal' despite intravascular low signal, and "poor" for equivocal diagnosis or non-visualization of the origin or segment of the vessels due to low signal or artifacts which needs catheter angiography. At the level of the carotid bifurcation, it was compared with conventional 2D-TOF MRA image. Overall image quality was also compared visually and quantitatively by measuring signal-to-noise ratios (SNRs) of the ascending aorta, the innominate artery and both common carotid arteries among the three different coils used(CP body array(n=12), CP neck array(n=9), and head-and-neck(n=8). Results : Demonstration of the aortic arch and its major branches was rated as "good" in 55% (16/29) and "fair" in 34%(10/29). At the level of the carotid bifurcation, image quality of turbo CE MRA was same as or better than conventional 2D-TOF MRA in 65% (17/26). Overall image quality and SNR were significantlygreater with CP body array coil than with CP neck array or head-and-neck coil. Conclusions : Turbo CE MRA can be used as a screening exam in the evaluation of the major branches of the aortic arch from their origin to the skull base. Overall imagequality appears to be better with CP body array coil than with CP neck array coil or head-and-neck coil.

  • PDF

Comparison of Image Quality and Effective Dose by Additional Filtration on Digital Chest Tomosynthesis (Digital Chest Tomosynthesis에서 부가필터에 따른 화질 및 유효선량)

  • Kim, Kye-Sun;Kim, Sungchul
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.347-353
    • /
    • 2015
  • The purpose of this study is to suggest proper additional filtration by comparisons patient dose and image quality among additional filters in digital chest tomosynthesis (DTS). We measured the effective dose, dose area product (DAP) by changing thickness of Cu, Al and Ni filter to compare image quality by CD curve and SNR, CNR. Cu, Al and Ni exposure dose were similar thickness 0.3 mm, 3 mm and 0.3 mm respectively. The exposure dose using filter was decreased average about 33.1% than non filter. The DAP value of 0.3 mm Ni were decreased 72.9% compared to non filter and the lowest dose among 3 filter. The effective dose of 0.3 mm Ni were decreased 48% compared to 0.102 mSv effective dose of non filter. At the result of comparison of image quality through CD curve there were similar aspect graph among Cu, Al and Ni. SNR was decreased average 19.07%, CNR was average decreased 18.17% using 3 filters. In conclusion, Ni filtration was considered to be most suitable when considered comprehensive thickness, character, sort of filter, dose reduction and image quality evaluation in DTS.

Video Quality Evaluation Method based on visual attention (시선인식 집중도 기반의 영상 품질 측정 방법)

  • Ko, Junggon;Seok, Jumyung;Suh, Doug Young
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2011.07a
    • /
    • pp.410-412
    • /
    • 2011
  • 영상 서비스에서 사용자가 시청하는 비디오 화질을 측정하는 것은 사용자의 QoE(Quality of Experience)를 추정할 수 있는 중요한 작업 중 하나이다. 이를 위해 가장 널리 쓰이는 측정 방법 중 PSNR이 있다. PSNR은 원본영상과 시청영상간의 각 픽셀 값의 차이를 계산하여 화질을 측정하는 객관적인 평가 방법이다. 본 논문에서는 객관적 평가 방법인 PSNR에 시청자가 영상 측정 시 느낄 수 있는 시선 인식 집중도를 접목시킨 품질 측정방법을 제안한다. 이는 사용자의 시각적 특성이 고려되기 때문에 보다 사용자에게 맞는 영상 품질을 측정할 수 있게 된다.

  • PDF