• Title/Summary/Keyword: 화재 크기

Search Result 325, Processing Time 0.026 seconds

Use of By-product Hydrated Lime as Alkali Activator of Blast Furnace Slag Blended Cement (고로수쇄(高爐水碎)슬래그 혼합(混合)시멘트의 알칼리 자극제(刺戟劑)로 부산소석회(副産消石灰)의 활용(活用))

  • Cho, Jin-Sang;Yu, Young-Hwan;Choi, Moon-Kwan;Cho, Kye-Hong;Kim, Hwan;Yeon, Kyu-Seok
    • Resources Recycling
    • /
    • v.19 no.3
    • /
    • pp.33-44
    • /
    • 2010
  • In this study, the possibility of utilizing carbide lime waste, obtained from the generation of acetylene process, as a alkali activator of blast furnace slag cement was investigated. The physical and chemical analysis of the carbide lime waste was studied and three types lime waste in order to investigate behaviour as alkali activator were used. Lime wastes were added 0, 10, 20 and 30 wt.% in blast furnace slag and blast furnace slag containing lime waste were added 0, 10, 30 and 50 wt.% in OPC. As a result of analysis of hydration properties, in the case of calcium hydroxide rehydrated after heat treatment at $800^{\circ}C$, it was higher hydration rate than other specimens. For the results of compressive strength test, when lime waste passed 325 mesh sieve and rehydrated calcium hydroxide were used, it was higher compressive strength than OPC from hydration 7days. At OPC50 wt.%-BFS45 wt.%-AA5 wt.% system using lime waste of 325 mesh under, the highest compressive strength appeared.

Thermal Characteristics of Living Leaves in Pinus Densiflora with Heat Flux (복사열 증가에 따른 소나무 생엽의 열적특성 분석)

  • Park, Young-Ju;Lee, Hae-Pyeong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.5
    • /
    • pp.75-82
    • /
    • 2010
  • To study the combustion characteristics of forest fuel by fire intensity, the experiment of combustion characteristics on Pinus Densiflora living leaves, which is the weakest species to the forest fire, was delivered, using variables of heat flux(25 kW/$m^2$, 50 kW/$m^2$, 75 kW/$m^2$). With the equipment of Cone calorimeter, the characteristics of ignition, heat, smoke release, CO and $CO_2$ release, and mass loss were analyzed. Pinus Densiflora living leaves containing moisture of 60.66% were not ignited at the heat flux of variables 25 kW/$m^2$, 50 kW/$m^2$, 75 kW/$m^2$. In proportion to the heat flux value, heat release amount and heat release rate reached maximum value rapidly: higher variables came to the maximum by the half rapidity and the maximum value were twice higher than the former lower variables respectively. As for the smoke release, the less heat flux the variable had, the more smoke release it had, due to incomplete combustion. The release amount of CO and $CO_2$ had more maximum value as the heat flux increased and more radiant heat meaned more carbon oxide. When the forest fire breaks out, therefore, a great amount of CO and $CO_2$ will be released by Pinus Densiflora.

A Study on the Effect of Surfactants in Acrylic Emulsion Polymerization (아크릴 에멀젼 중합에서의 계면활성제 영향에 관한 연구)

  • Song, Ju-Ho;Park, Sang-Joon;Park, Sang-Kwon;Lee, Myung-Cheon;Lim, Jong-Choo
    • Applied Chemistry for Engineering
    • /
    • v.10 no.4
    • /
    • pp.523-530
    • /
    • 1999
  • Acrylic pressure-sensitive adhesive has been made utilizing organic solvents, but nowadays it is made by solvent-free system due to environmental problems. In this study, emulsion polymerization were carried out at $40^{\circ}C$ with methacrylic acid(MAA), n-butyl acrylate(n-BA) and 2-ethylhexyl acrylate(2-EHA) as monomers in the presence of anionic(sodium dodecyl sulfate, SDS) and nonionic(ethylene oxide types) surfactant mixtures. The overall conversion of the polymerization reaction in a mixed surfactant system was found to be higher than that in a single surfactant system. Emulsion stability in mixed or anionic surfactant systems was found to be over 12 week, which was better than that in nonionic surfactant system. Emulsion particle size decreased as surfactant content increased. The Tg and molecular weight of emulsion polymer were inependent of the type, the amount and the mixing ratio of surfactant. Based on the results of stability and peel strength, the optimum nonionic surfactant ratio in total 4 g of surfactant mixture systems is found to be 40~60% by weight where the nonionic surfactant has 50 ethylene oxide groups and 16~18 carbon atoms in hydrophobic alkyl chain.

  • PDF

Numerical analysis on effect of hole size on Emergency Evacuation Support System (수치해석을 통한 비상피난지원 시스템의 급기구 크기에 따른 유동분석)

  • Kim, Ji Tae;Park, Won Hee;Lee, Duck Hee;Ro, Kyoung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.324-329
    • /
    • 2020
  • The emergency evacuation support system provides a safe means of evacuation by preventing the inflow of smoke through the formation of a smoke shield curtain in fire situations and pressurizing fresh air to the inside of the smoke shield curtain. In this study, numerical analysis was performed to examine the effects of the hole size on the flow inside the smoke curtain. As the air supply size decreased, the flow rate through the air supply was formed relatively uniformly from the inlet to the outlet length of the emergency support system. In addition, the size of the air supply hole was more than 20 mm, the flow rate was very low near the outlet, so the air supply hole size should be smaller than 20 mm. In addition, the minor loss of the air supply hole was calculated to be K = 1.5 from the numerical results. Therefore, the proper design of an emergency evacuation support system is possible using the flow characteristics according to the size and minor loss of the air supply hole.

A Study on Measurements of Autoignition and Activation Energy of Superabsorbent Polymers (고흡수성 중합체의 자연발화와 활성화에너지 측정에 관한 연구)

  • Jong-Man Heo;Jae-Wook Choi
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.2
    • /
    • pp.292-304
    • /
    • 2023
  • Purpose: This study was conducted to obtain experimental data for the establishment of preventive measures against fire, as large and small fire accidents occur at production and storage sites of superabsorbent polymers developed for the convenience of daily life. Method: The sample container was fixed at 0.2m in both length and width, and was shaped into a rectangular cuboid with heights of 3cm, 5cm, 7cm, and 14cm to access an infinite flat plane. The sample container was fixed in the center of a thermostatic bath that was heated to a predetermined temperature according to a preset temperature control program. If the central temperature of the sample rose more than 20℃ above the set temperature, it was determined to have 'ignited', and if it remained similar to the set temperature, it was determined to have 'unignited'. Result: The critical autoignition temperature was calculated to be 212.5℃ for a sample container with a height of 3cm, 202.5℃ for 5cm, 192.5℃ for 7cm, and 177.5℃ for 14cm. The ignition induction time to reach the highest temperature was approximately 42hours for 3cm, 91hours for 5cm, 151hours for 7cm, and 300hours for 14cm. Conclusion:① As the size of the sample container increased, the autoignition temperature decreased and the ignition induction time to reach the highest temperature increased. ② The apparent activation energy was calculated to be 39.30kcal/mol, with a correlation of 99.5%.

A Study on the Damage of Fireball by the Butane-Can Explosion (부탄 캔 파열로 인한 화구의 피해에 관한 연구)

  • Leem, Sa-Hwan;Huh, Yong-Jeong
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.4
    • /
    • pp.110-116
    • /
    • 2007
  • There have been 3E problems of energy, economy and environment since the earth has its history. Especially, as the industrial society is highly developing, human need in daily life has also changed drastically. With the introduction of 40 hour working week system, more households enjoy picnics on weekends. More gas accidents take place on Saturdays and on Sundays than any other days of week. Consequently, this study tries to find out the influence of flame caused by the explosion of butane canister on the adjacent combustibles and people by simulating relevant quantity of TNT. In addition, the damage estimation was conducted by using API regulations. If the scale of the radiation heat is known by calculating the distance of flame influence from the explosion site, the damage from the site can be easily estimated. And the accident damage was estimated by applying the influence on the adjacent structures and people into the PROBIT model. According to the pro bit analyze, the spot which is 50cm away from the flame has 97% of the damage probability by the first-degree burn, 8% of the damage probability by the second-degree burn and 4% of the death probability by the fire.

Stability Analysis of Concrete Shear Wall System with Opening (개구부를 갖는 전단벽의 안정해석)

  • Lee, Soo-Gon;Kim, Soon-Chul;Song, Chang-Young;Song, Sang-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.4
    • /
    • pp.109-118
    • /
    • 2005
  • A concrete shear wall system is commonly adopted in high-rise residential apartment buildings. In the construction stage, a rectangular opening is often made for the convenience of horizontal movement of workers, and construction materials and equipment. In the case of safety or stability assessment of a shear wall, the cutout part can be a critical factor. Finite element method is adopted to investigate the elastic stability behavior of the perforated unit shear wall. The key analysis parameters are the cutout location and its size. The effect of out-of-plane bending and horizontal shear are also examined in the stability analysis.

Synthesis and Evaluation of New Nonflammable Cleaning Agents (난연성 세정제의 합성 및 평가에 관한 연구)

  • Kim, Ah Na;Yu, Young;Kim, Seok Chan
    • Clean Technology
    • /
    • v.19 no.2
    • /
    • pp.184-188
    • /
    • 2013
  • To increase flash point which is related to flammability, seven unprecedented new cleaning agents containing fluoride atoms have been invented. These newly synthesized cleaning agents's physical properties which were conducted by Korea Institute of Petroleum Management by using a standard method showed excellent values. Particularly, flash point of newly synthetic cleaning agents is more higher than that of fluoride free compound. A specimen for cleaning ability was prepared by cutting in $60mm{\times}40mm$ size of stainless steel plate. The surface of the above specimens was applied with four kinds of contaminants, such as paraffin based drawing oil, flux abietic acid, water-insoluble cutting oil, and lubricating oil. Contaminated specimens were immersed in new compounds (1-7) for 1 to 5 minutes to dissolve oil in the cleaning agent. Although the data indicate that all compounds (1-7) exhibit lower cleaning ability toward cutting oil, it is observed that in the case of the present study more than 80% of pollutants on the surface were almost removed within 5 minutes.

Performance Analysis of Real-Time Video Management System Based on Multi-Hop Wi-Fi Direct Communication (멀티 홉 Wi-Fi Direct 통신 기반 실시간 영상관리 시스템 성능 분석)

  • Woo, Chae-yul;Jo, Mi-ran;Kwon, Soon-ryang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.11
    • /
    • pp.1472-1480
    • /
    • 2016
  • When disasters such as earthquake, flood, typhoon, fire and terrorism are occurred a video management system is required which can shoot video on the disaster site, and send it to a server located in the command center that can grasp at a glance the site conditions. In this paper, to know the performance elements information needed to construct the video management system. we presented a method of configuring an ad hoc network based on Wi-Fi direct communication. And we also evaluated the performance through built of environment for the video management system. The evaluated performance test items are 'packet flow tests according to the video compression ratios and the image sizes', 'packet flow tests according to the distance and traffic tests', 'packet flow tests according to whether LOS or not', and 'performance test of scenarios'.

A Feasibility Study on the Polymer Solidification of Evaporator Concentrated Wastes (폐액증발기 농축폐액 폴리머고화 타당성 연구)

  • Yang, Ho-Yeon;Kim, Ju-Youl
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.4
    • /
    • pp.297-308
    • /
    • 2007
  • The granulation equipment of concentrated wastes is manufactured for the polymer solidification of concentrated wastes. It uses liquid sodium silicate as a granulating agent for the granulating of dried powder containing boric acid. The granulating agent is sprayed in the form of droplet and mean size of dried granules is $2{\sim}4mm$. The new technology which has been used for the polymer solidification of spent resin in U.S. and certified by Nuclear Regulatory Commission (NRC) is successfully applied to concentrated wastes. This uses in-situ solidification process within drum without mechanical mixing. Maximum loading of waste can be achieved without increasing of waste volume. Polymer waste forms were evaluated with several test such as fire test, compressive strength test, leaching test, immersion test, irradiation test, and thermal cycling test according to standard test procedures.

  • PDF