• 제목/요약/키워드: 화재 크기

검색결과 326건 처리시간 0.816초

A Study on Charring Rate of Wood Exposed to a Constant Incident Radiation Heat Flux (일정한 복사열원에 노출된 목재의 탄화속도에 관한 연구)

  • Park Hyung-Ju;Kim Hong
    • Fire Science and Engineering
    • /
    • 제18권4호
    • /
    • pp.86-92
    • /
    • 2004
  • We tested five specimens of each species at each of five constant external heat flux levels (10, 15, 20, 25. and 35㎾/㎡). An Cone heater was used to expose the wood specimens to the heat flux. The 100-by 100-by 50-㎜ specimens were of four species: Redwood, White oak, Douglas fir, Maple. In result of test, charring of wood exposed to a constant external heat flux can be considered a linear with function of time. As compared with the charring rates Redwood is most rapidly, but on the other hand Douglas fir is most slowly. When the external heat flux is 35㎾/㎡, the charring rate is rapidly about twice then 10㎾/㎡. Using the Equation (2), the estimates for u were 1.02, 1.16, 1.23, 1.32, and 1.44 for the 10, 15, 20, 25, and 35 kw/m2 constant external exposure levels, respectively.

Experimental Study on the Fire Resistance of the iTECH Composite Beam (iTECH 합성보의 내화성능에 대한 실험연구)

  • Lee, Sueng Jae;Kang, Seong Deok;Choi, Seng Kwan;Kim, Myeong-Han;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • 제18권5호
    • /
    • pp.643-654
    • /
    • 2006
  • Thispaper presents the results of an experimental investigation into the fire performances ofsimply supported iTECH composite beams using an ISO834 standard fire. There are very few independent studies on the fire resistance of composite steel and concrete structures of various designs. The iTECH composite beam system has been used in construction, but nothing is known about its influence in a fire. To evaluate the fire resistance performanceof the iTECH beam, a test was conducted for 4.7m-span-length iTECH beams under given conditions in a laboratory. The fire resistance performance of unprotected coatings of the iTECH beam has been examined, and a longer period of fire resistance was achieved by increasing the beam coating's section size and decreasing its load ratio. Coatings for the fire protection of iTECH beams reduce the rate of temperature rise of the beam in case of fire, and the required thickness of spray-on fire protection coatings can be determined by means of tests.

A Study on Combined Processes of Sliding Arc Plasma and Corona Dielectric Barrier Discharge for Improve the Efficiency Treatment of Harmful Substance (슬라이딩아크 방전과 코로나 방전의 복합공정을 통한 유해물질 처리효율 개선에 관한 연구)

  • Kwon, Woo-Taeg;Lee, Woo-Sik
    • Fire Science and Engineering
    • /
    • 제28권6호
    • /
    • pp.108-113
    • /
    • 2014
  • The combined process of Sliding Arc Plasma and corona dielectric barrier discharge process (CDBD) was used to efficiently improve harmful substance, which convert into OH radicals which have strong oxidation potential, and so have deodorization and sterilizing effects, by generating specific radicals and anion and then reacting with the moisture contained in harmful substance. As a result of experiment, even if the size of SAP reactor is reduced from 80 A to 50 A, there is no much change and therefore it is judged the size of reactor may be minimized. And it was confirmed that after the anion and ozone generated from CDBD rector react with harmful substance, a anion was reduced from 510,000 ppb to 470 ppb and ozone from 98 ppb to 22 ppb. It was also judged the stability and durability of plasma producer are excellent. Accordingly, it is considered the harmful substances which exist in indoor air quality will be efficiently improved and removed by using further plasma combined process through this study.

Influence of Stack Effect in High-Rise Buildings on Wind Effect in Jeju (Comparative Analysis of Seoul and Jeju) (제주지역 고층건축물에서의 바람의 영향이 굴뚝효과에 미치는 영향 분석 (서울과 제주지역간의 비교 분석))

  • Lim, Chae-Hyun
    • Fire Science and Engineering
    • /
    • 제29권6호
    • /
    • pp.6-12
    • /
    • 2015
  • This study used CONTAM modeling to analyzed analyze the stack effect in high-rise buildings for the terrain and weather conditions of Seoul and Jeju. The differential pressure caused by the stack effect is a function of the indoor and outdoor temperature difference and the height of the vertical shaft. Jeju is considered more stable than Seoul, because it is warmer than Seoul in winter. The differential pressure in Jeju is about 60% that of Seoul in for the same height of buildings in winter. However, Jeju is an island and the neutral plane is raised by over 56% by strong winds, although there is less differential pressure caused by the stack effect in Jeju than in Seoul. Due to the raised neutral plane, the region and magnitude of negative pressure in the lower part is larger in Jeju than in Seoul.

An Experimental Study on The Fire Resistance Performance of High Strength Concrete Column mixed Fiber-Cocktail in Standard Fire Condition (하이브리드 섬유를 적용한 고강도 내화콘크리트의 단면크기에 따른 내화성능에 관한 실험적 연구)

  • Kim, Heung-Youl;Kim, Hyung-Jun;Cho, Bum-Yean;Min, Byung-Youl;Ahn, Chan-Sol
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 한국화재소방학회 2011년도 춘계학술논문발표회 논문집
    • /
    • pp.170-175
    • /
    • 2011
  • 최근 고강도 콘크리트의 내화성능이 사회적 이슈로 부각되고 국토해양부에서 고강도 콘크리트의 내화성능 관리기준(안)이 고시되면서 국내에서도 고강도 콘크리트의 내화성능을 향상시키기 위한 연구가 활발히 진행되고 있다. 본 연구에서는 유기질 섬유인 폴리프로필렌섬유(PP섬유)와 강섬유를 하이브리드한 Fiber Cocktail를 혼입한 고강도 내화콘크리트 개발을 위한 연구를 수행하였다. PP섬유는 $160^{\circ}C$의 온도에서 용융되어 콘크리트 내부에 미세한 통로를 형성하여 고강도 콘크리트 부재 내의 수증기압 및 공극압을 효과적으로 배출하여 고강도 콘크리트의 폭렬발생을 억제시키는 데 효과적이며, 강섬유는 PP섬유가 용융된 후의 고강도 콘크리트 부재의 균열 발생을 억제하며 외부로부터 침투하는 열기를 차단할 수 있다. 100MPa 고강도 콘크리트의 내화실험을 실시하여 최적단면 조건을 도출하기 위해 철근온도를 분석한 결과, 단면이 커질수록 철근온도는 점차 낮아지는 경향이 나타났으며 $600{\times}600mm$, $800{\times}800mm$ 단면에서 내화성능을 확보할 수 있는 것으로 나타났으며, 이중 경제성을 고려할 경우 $600{\times}600mm$ 단면이 최적단면으로 도출되었다. 또한 도출된 $600{\times}600mm$ 단면에 대해서 철근의 온도를 분석한 결과 PP섬유 $1.5kg/m^3$와 강섬유 $40kg/m^3$를 배합한 Fiber Cocktail이 최적배합비로 나타났다.

  • PDF

A Combustion Characteristics of Attached Jet Flame under the Regular Oscillation (규칙적인 진동 하에서 노즐 부착된 제트화염의 연소특성)

  • Kim, Dae-Won;Lee, Kee-Man
    • Fire Science and Engineering
    • /
    • 제23권1호
    • /
    • pp.55-62
    • /
    • 2009
  • A general combustion characteristics of forcing nonpremixed jet in laminar flow rates have been conducted experimentally to investigate the effect of forcing amplitude with the resonant frequency of fuel tube. There are two patterns of the flame lift-off feature according to the velocity increasing; one has the decreasing values of forcing amplitude on the lift-off occurrence when a fuel exit velocity is increasing, while the other has the increasing values. These mean that there are the different mechanisms in the lift-off stability of forced jet diffusion flame. Especially, the characteristics of attached jet flame regime are concentrically observed with flame lengths, shapes, flow response and velocity profiles at the nozzle exit as the central figure. The notable observations are that the flame enlogation, in-homing flame and the occurrence of a vortical motion turnabout have happened according to the increase of forcing amplitude. It is understood by the velocity measurements and visualization methods that these phenomena have been relevance to an entrainment of surrounding oxygen into the fuel nozzle as the negative part of the fluctuating velocity has begun at the inner part of the fuel nozzle.

A Combustion Characteristic Analysis of Quercus Variabilis and Pinus Densiflora Fallen Leaves Using Radiation Heat Flux (복사열을 이용한 소나무와 굴참나무 낙엽의 연소특성 분석)

  • Park, Hyung-Ju;Kim, Eung-Sik;Kim, Jang-Hwan;Kim, Dong-Hyun
    • Fire Science and Engineering
    • /
    • 제21권3호
    • /
    • pp.41-46
    • /
    • 2007
  • The combustion characteristics of surface forest fire fuels was analysed using variable external irradiation level. The characteristics such as ignition time, ignition temperature, critical heat flux and mass loss rate were measured. Fuel samples were exposed to incident heat fluxes from 8 to $50\;kW/m^2$. For the measurement of various combustion characteristics, the size of specimen holder was $100\;mm{\times}100\;mm{\times}12\;mm$ and the fuel samples grinded by electric mill were the fallen leaves of Quercus variabilis and Pinus densiflora. As results, the occurrence of ignition is possible to the heat flux more than $9\;kW/m^2$. The fuel of Pinus densiflora keeps its high temperature longer than that of Quercus variabilis during the combustion process. The results of measurement shows that the maximun and average mass loss rate of Quercus variabilis larger than that of Pinus densiflora.

Design of Fire-fighting Ambulance Interior (119 구급자동차의 내부 디자인 개발에 관한 연구)

  • Shin, Dong-Min;Park, Min-Jung;Han, Yong-Taek
    • Fire Science and Engineering
    • /
    • 제30권1호
    • /
    • pp.121-129
    • /
    • 2016
  • Ambulances are an important element of pre-hospital emergency medical services, and also an important space for improving the work efficiency of paramedics. Paramedics use the interior environment to maximize the capabilities of the space, but ambulances need to be improved to help with the responsibilities of paramedics. A Seamless space was constructed in accordance with the placement of first-aid emergency medical equipment and drugs, and a patient room was loaded in the interior space of an ambulance. This study was to improve the treatment space of an ambulance to improve the efficiency of work by paramedics The new design provides safety and efficiency for emergency medical services through planning of interior storage suitable for the duties of paramedics and through identification and analysis of the problems in the environment.

Study of the Standard Testing Specifications for a Non-loading Performance Evaluation of Coating Material-sprayed Circular Steel Structures (뿜칠 피복 원형 철골구조의 비재하 내화성능 평가용 시험체 제안을 위한 연구)

  • Ok, Chi-Yeol;Kim, Jae-Jun
    • Fire Science and Engineering
    • /
    • 제30권3호
    • /
    • pp.7-15
    • /
    • 2016
  • The cross-sectional shape factor is used worldwide to evaluate the scientific performance of fire-resistant structures. In South Korea, however, a system for applying a cross-sectional shape factor has not been arranged and circular or rectangular steel pipes are commonly used for large-scale steel frame buildings. On the other hand, coating material-spray steel beams and pillars that have received the certification of a fire-resistant structure from recognized organizations are mostly limited to a H-beam. A H-beam is granted a wide range of certifications without size limitations from a non-loading performance test with test standards based on the relevant provisions. Other types of steel pipe are to be certified for fireresistance according to shape. In this study, a cross-sectional shape factor was used to propose standard testing specifications for the application of coating material-sprayed circular and rectangular steel pipes, eventually to set the scope of certification for reasonable fire-resistant structures.

Extinguishing Characteristics of Liquid Pool Eire by Water Mist Containing Sodium Salt (나트륨 염이 첨가된 미분무수의 액체 pool fire소화특성)

  • Park Jae-Man;Shin Chang-Sub
    • Fire Science and Engineering
    • /
    • 제19권3호
    • /
    • pp.13-19
    • /
    • 2005
  • An experimental study is presented for extinguishing characteristics of liquid fuel fire by water mist containing sodium acetate trihydrate. To evaluate the extinguishing performance of water mist containing an additive, the evaporation characteristics of a water droplet on a heated surface was examined. The evaporation process was recorded by a charge-coupled-device camera. Also, small-scale extinguishing tests were conducted for n-heptane pool fire in ventilated space to measure flame temperature variation. The average evaporation rate of a water droplet containing an additive was lower than that of a pure water droplet at a given surface temperature due to the precipitation of salt in the liquid-film and change of surface tension. In case of using an additive, the flame temperature was lower than that of pure water at a given discharge pressure and it was because the momentum of a water droplet containing an additive was increased reducing flame size. And also dissociated metal atoms, sodium, were reacted as a scavenger of the major radical species OH^-,\;H^+$ which were generated for combustion process. Moreover, at a high pressure of 4MPa, the fire was extinguished through blowing effect as well as primary extinguishing mechanisms.