• Title/Summary/Keyword: 화재 사고

Search Result 1,170, Processing Time 0.034 seconds

Analysis of Internal Flow and Control Speed for NH3 (Ammonia) Leakage Scenario of ALD Facility (ALD 설비의 NH3(Ammonia)누출 시나리오에 대한 내부유동 및 제어 속도 해석)

  • Lee, Seoung-Sam;An, Hyeong-hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.5
    • /
    • pp.22-27
    • /
    • 2022
  • Atomic Layer Deposition (ALD) is a facility that deposits an atomic layer on a wafer by causing a chemical reaction after decomposition using heat or plasma by inputting two or more gases during the semiconductor process. The main gas used at this time is NH3 (Ammonia). NH3 has a relatively narrow explosive range with an upper limit (UFL) of 33.6% and a lower limit (LEL) of 15%, but it can explode if a large amount suddenly gathers in one place. It is Velocity and fatal if inhaled or in contact with the skin. NH3 (Ammonia) of ALD (Atomic Layer Deposition) facility is supplied to the chamber through the gas inlet and discharged after the reaction.

A study on the effective fault current limiting characteristics of stacked coated conductors with stainless steel stabilizer (스테인리스 스틸 안정화재를 가진 coated conductor의 적층 유무에 따른 효과적인 사고전류 제한을 위한 연구)

  • Na, J.B.;Ahn, M.C.;Kim, M.J.;Kim, Y.J.;Yang, S.E.;Park, D.K.;Kim, H.M.;Seok, B.Y.;Ko, T.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.9-13
    • /
    • 2007
  • Coated conductor(CC) is recently in actively progress for the research and development, and its can be used various stabilizer lot the specific requirements for each application. Among various superconducting applications, coated conductor applied to superconducting fault current limiters(SFCLS) bypasses fault current to its stabilizer, where the surge is abruptly reduced ; thus, stainless steel, which has large resistivity can be a suitable stabilizer for SFCLS. Despite high n-value of the YBCO, CC stabilized with stainless steel did not effectively limit the first peak fault current. In the short circuit test results of AMSC's 344S, a half period delay was observed between the fault and the generation of resistance(60Hz). In this paper, we performed short-circuit experiments with stacked and unstacked CC and compared the test results to analyze effective fault current limiting characteristics. we compared time of the generated resistance as the fault current limiting characteristics and made the samples one is the stacked CC and the other is unstacked CC. These samples were used equal numbers of pieces of CC. In addition, comparison and analysis was made for the stacked structure by measuring fault current limiting characteristics with respect to thermal insulation by impregnating with epoxy resin.

The need to introduce a Common Operating Picture(COP) for disaster response in the event of a disaster (재난발생시 재난대응을 위한 공통작전상황도(COP) 도입 필요성)

  • Cho, Jung Yun;Song, Ju Il;Jang, Cho-Rok;Jang, Mun-Yeop
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.358-358
    • /
    • 2020
  • 2016년 경주지진, 2018년 밀양 세종병원 화재사고, 2019년 강원도 동해안 산불, 2020년 코로나바이러스감염증-19 재난까지 매년 다양한 유형의 재난이 발생하면서 재난대응에 대한 관심 역시 커지고 있다. 정부는 물론 각 지자체에서 재난유형별로 재난대응 매뉴얼에 따라 체계적으로 해당 재난에 대한 대응을 실시하고 있으나 중앙 상황실과 현장 간 소통의 어려움, 의사결정의 지연 등으로 인해 신속한 대응방안 수립 및 피해상황 파악에 있어서 미흡한 대처를 보여주어 질타를 받기도 하였다. 본 연구에서는 중앙 상황실과 현장 간의 원활한 소통과 재난으로 발생한 피해현황 및 응급복구 계획 등을 신속하게 수립할 수 있도록 군부대에서 사용하고 있는 공통작전상황도(Common Operating Picture, 이하 COP)의 개념을 재난대응 체계에 도입하여 제시하고자 한다. 공통작전상황도는 미군이 군사적인 대응을 위하여 정보공유 차원에서 처음으로 사용되었으며, 미국연방재난관리청(Federal Emergency Management Agency, 이하 FEMA)이 현재 재난상활 발생 시 의사결정을 지원하기 위한 시스템으로 개발하여 활용하고 있다. 이를 구성하는 요소들은 재난발생시 가장 기초적인 정보(신고사항, 기상정보, 시민제보 등) 뿐 만 아니라 현장에 관한 정보(구체적인 대응상황, 요구사항 등)까지 다루어지고 있으며, 결국 공통작전상황도는 이를 모두 관리할 수 있는 하나의 통합플랫폼이라 할 수 있다. 따라서 본 연구에서는 재난상황에서 공통작전상황도를 활용한 해외사례 분석과 국내 도입 시각 재난유형별로 공통작전상황도에 필요한 정보요소들을 1차적으로 확인함으로써 새로운 재난대응 시스템의 필요함을 강조하고자 한다.

  • PDF

A basic study on explosion pressure of hydrogen tank for hydrogen fueled vehicles in road tunnels (도로터널에서 수소 연료차 수소탱크 폭발시 폭발압력에 대한 기초적 연구)

  • Ryu, Ji-Oh;Ahn, Sang-Ho;Lee, Hu-Yeong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.517-534
    • /
    • 2021
  • Hydrogen fuel is emerging as an new energy source to replace fossil fuels in that it can solve environmental pollution problems and reduce energy imbalance and cost. Since hydrogen is eco-friendly but highly explosive, there is a high concern about fire and explosion accidents of hydrogen fueled vehicles. In particular, in semi-enclosed spaces such as tunnels, the risk is predicted to increase. Therefore, this study was conducted on the applicability of the equivalent TNT model and the numerical analysis method to evaluate the hydrogen explosion pressure in the tunnel. In comparison and review of the explosion pressure of 6 equivalent TNT models and Weyandt's experimental results, the Henrych equation was found to be the closest with a deviation of 13.6%. As a result of examining the effect of hydrogen tank capacity (52, 72, 156 L) and tunnel cross-section (40.5, 54, 72, 95 m2) on the explosion pressure using numerical analysis, the explosion pressure wave in the tunnel initially it propagates in a hemispherical shape as in open space. Furthermore, when it passes the certain distance it is transformed a plane wave and propagates at a very gradual decay rate. The Henrych equation agrees well with the numerical analysis results in the section where the explosion pressure is rapidly decreasing, but it is significantly underestimated after the explosion pressure wave is transformed into a plane wave. In case of same hydrogen tank capacity, an explosion pressure decreases as the tunnel cross-sectional area increases, and in case of the same cross-sectional area, the explosion pressure increases by about 2.5 times if the hydrogen tank capacity increases from 52 L to 156 L. As a result of the evaluation of the limiting distance affecting the human body, when a 52 L hydrogen tank explodes, the limiting distance to death was estimated to be about 3 m, and the limiting distance to serious injury was estimated to be 28.5~35.8 m.

Preparation of EVA/Intumescent/Nano-Clay Composite with Flame Retardant Properties and Cross Laminated Timber (CLT) Application Technology (난연특성을 가지는 EVA/Intumescent/나노클레이 복합재료 제조 및 교호집성재(Cross Laminated Timber) 적용 기술)

  • Choi, Yo-Seok;Park, Ji-Won;Lee, Jung-Hun;Shin, Jae-Ho;Jang, Seong-Wook;Kim, Hyun-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.1
    • /
    • pp.73-84
    • /
    • 2018
  • Recently, the importance of flame retardation treatment technology has been emphasized due to the increase in urban fire accidents and fire damage incidents caused by building exterior materials. Particularly, in the utilization of wood-based building materials, the flame retarding treatment technology is more importantly evaluated. An Intumescent system is one of the non-halogen flame retardant treatment technologies and is a system that realizes flame retardancy through foaming and carbonization layer formation. To apply the Intumescent system, composite material was prepared by using Ethylene vinyl acetate (EVA) as a matrix. To enhance the flame retardant properties of the Intumescent system, a nano-clay was applied together. Composite materials with Intumescent system and nano - clay technology were processed into sheet - like test specimens, and then a new structure of cross laminated timber with improved flame retardant properties was fabricated. In the evaluation of combustion characteristics of composite materials using Intumescent system, it was confirmed that the maximum heat emission was reduced efficiently. Depending on the structure attached to the surface, the CLT had two stages of combustion. Also, it was confirmed that the maximum calorific value decreased significantly during the deep burning process. These characteristics are expected to have a delayed combustion diffusion effect in the combustion process of CLT. In order to improve the performance, the flame retardation treatment technique for the surface veneer and the optimization technique of the application of the composite material are required. It is expected that it will be possible to develop a CLT structure with improved fire characteristics.

Study on the Consequence Effect Analysis & Process Hazard Review at Gas Release from Hydrogen Fluoride Storage Tank (최근 불산 저장탱크에서의 가스 누출시 공정위험 및 결과영향 분석)

  • Ko, JaeSun
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.449-461
    • /
    • 2013
  • As the hydrofluoric acid leak in Gumi-si, Gyeongsangbuk-do or hydrochloric acid leak in Ulsan, Gyeongsangnam-do demonstrated, chemical related accidents are mostly caused by large amounts of volatile toxic substances leaking due to the damages of storage tank or pipe lines of transporter. Safety assessment is the most important concern because such toxic material accidents cause human and material damages to the environment and atmosphere of the surrounding area. Therefore, in this study, a hydrofluoric acid leaked from a storage tank was selected as the study example to simulate the leaked substance diffusing into the atmosphere and result analysis was performed through the numerical Analysis and diffusion simulation of ALOHA(Areal Location of Hazardous Atmospheres). the results of a qualitative evaluation of HAZOP (Hazard Operability)was looked at to find that the flange leak, operation delay due to leakage of the valve and the hose, and toxic gas leak were danger factors. Possibility of fire from temperature, pressure and corrosion, nitrogen supply overpressure and toxic leak from internal corrosion of tank or pipe joints were also found to be high. ALOHA resulting effects were a little different depending on the input data of Dense Gas Model, however, the wind direction and speed, rather than atmospheric stability, played bigger role. Higher wind speed affected the diffusion of contaminant. In term of the diffusion concentration, both liquid and gas leaks resulted in almost the same $LC_{50}$ and ALOHA AEGL-3(Acute Exposure Guidline Level) values. Each scenarios showed almost identical results in ALOHA model. Therefore, a buffer distance of toxic gas can be determined by comparing the numerical analysis and the diffusion concentration to the IDLH(Immediately Dangerous to Life and Health). Such study will help perform the risk assessment of toxic leak more efficiently and be utilized in establishing community emergency response system properly.

Selection of Retaining Wall System for Underground Parking Lots Expansion of Apartments (거주중 공동주택의 지하주차장확대를 위한 흙막이공법 선정)

  • Ro, Young-Chang;Lee, Chan-Sik
    • Korean Journal of Construction Engineering and Management
    • /
    • v.9 no.2
    • /
    • pp.99-107
    • /
    • 2008
  • Rapidly increasing automobile supply rate according to improved economic level of life makes lack of parking space of apartments. Even though the initial design of parking space compiled with old regulations, it may not observe either new laws or requirement of inhabitants. Even if old apartments have no structural durability problem, outworn facilities and insufficient parking area may be a main reason for reconstruction. It causes waste of national resources and makes recycling issues. Additionally, irregularly parked cars make traffic obstruction to a fire engine and result in many fire accident victims. Parking problems of apartments are not only inconvenience but also serious safety issues. From these points of view, remodeling only for parking area expansion is necessary to avoid overall reconstruction of apartments. The purpose of this study is to suggest a retaining wall selection method for apartments underground parking lots expansion without evacuation of resident people. Effect factors to select retaining wall system are analyzed and weight values are calculated by applying AHP. One selection method of retaining wall is proposed by evaluating applicability and its sensitivity analysis is executed. This selection method is expected to help decision-making of retaining wall system selection.

Battery Level Calculation and Failure Prediction Algorithm for ESS Optimization and Stable Operation (ESS 최적화 및 안정적인 운영을 위한 배터리 잔량 산출 및 고장 예측 알고리즘)

  • Joo, Jong-Yul;Lee, Young-Jae;Park, Kyoung-Wook;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.1
    • /
    • pp.71-78
    • /
    • 2020
  • In the case of power generation using renewable energy, power production may not be smooth due to the influence of the weather. The energy storage system (ESS) is used to increase the efficiency of solar and wind power generation. ESS has been continuously fired due to a lack of battery protection systems, operation management, and control system, or careless installation, leading to very big casualties and economic losses. ESS stability and battery protection system operation management technology is indispensable. In this paper, we present a battery level calculation algorithm and a failure prediction algorithm for ESS optimization and stable operation. The proposed algorithm calculates the correct battery level by accumulating the current amount in real-time when the battery is charged and discharged, and calculates the battery failure by using the voltage imbalance between battery cells. The proposed algorithms can predict the exact battery level and failure required to operate the ESS optimally. Therefore, accurate status information on ESS battery can be measured and reliably monitored to prevent large accidents.

A Study on Evacuation Time According to Seafarer Visibility (선원들의 가시거리별 피난시간 연구)

  • Kim, Won-Ouk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.6
    • /
    • pp.600-606
    • /
    • 2016
  • Seafarers are often placed in circumstances that require emergency evacuations due to various causes, including ship collisions, sinking, stranding, and fires. Achieving shorter evacuation time is an important factor in increasing the survival rate during these circumstances, but the narrow and complicated structure of ships is an obstacle when it comes to executing a quick evacuation. Also, unpredictable restrictions may be imposed by bad sea or weather. In this study, various experiments were conducted with sailors currently on board ships in order to examine factors that increase evacuation time. The data was then and analyzed. Evacuation time was measured by dividing crews into groups: sailors that were given an explanation of the ship's structure and those that were not. Furthermore, the visibility range was divided into 0 m, 3 m, and 5 m. The results indicated that, having an explanation of the ship structure did not have much of an effect on evacuation time but visibility conditions led to an increase in evacuation time with a maximum of 2.5 to 2.6 times longer when the visible distance was 5 m, 0 m and 3 m. Therefore, ensuring a visible distance of over 5 m was determined to be the most important factor for reducing evacuation time. In the future, effort should be made to ensure a greater visible distance to improve the survival rate of seafarers and passengers on board ships that encounter incidents.

Evacuation safety analysis depending on the type of subway platform and ticket barrier (지하철 승강장과 개찰구 유형별 대피안전성 분석)

  • Park, Byoung-Jik;Park, Il-Gyu;Yoo, Yong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.237-242
    • /
    • 2015
  • With the rapid development of modern society, subway has become one of the most typical urban transport systems. Since fire accident occurred at Daegu subway in 2003, importance of life safety and disaster prevention have been widely recognized and many studies have been carried out. As a result of these studies, fire-retardant and non-combustible interior material and platform screen door with passenger guide indication device have been developed, but studies on a subway evacuation criteria have been in a stalemate. Therefore, this study is intended to improve the subway evacuation standard. It is very difficult to take into account whole subway system, so a typological approach to a ticket was carried out referring to previous studies focused on a subway platform. this paper selected the most common subway platforms and estimated evacuation time among 10 platforms from previous studies and 8 from this study. As a result, evacuation time exceeded 6 minutes which is the guideline of existing standard. Therefore, it is necessary to update the standard for evacuation time and add supplementary conditions which can help establishing the measures for safety facilities and prevention measures.